MAURY USCG vessel records Sign in
← All vessels

MUKARNAS

MUKARNAS is a 1995 freight ship. The Coast Guard has recorded 20 inspections since 1995, most recently in September 2010, along with 16 deficiencies and 2 operational controls.

Records from 1995 to 2010. Most recent: inspection, 14 September 2010.

Built
1995
Last inspected
14 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9113874 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
426555
Flag
PANAMA
—
Maury page id
psix-426555

Inspections, by type

…with no type recorded12
Years with a record 10 calendar years (1995–2010)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it14430 - Regulatory (Subpart C or D), Gross Ton
8741 - Regulatory (Subpart C or D), Net Ton
28732 - Displacement, Ton
23712 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

14 September 2010 Ballast Water Examination · ISPS III Exam · Deficiency Check · PII Safety Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3845187
21 January 2010 Ballast Water Examination · PI Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3661367
8 January 2010 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3661294
18 March 2005 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2311155
16 March 2005 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2312137
28 January 2005 ISPS III Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2280378
15 November 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2261317
7 July 2004 ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2116224
24 June 2003 Deficiency Check
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1826683
22 June 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1841271
15 May 2003 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1794128
13 May 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1874154
29 May 2002 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1628372
4 February 2002 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1481912
11 December 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 435524
7 November 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 422272
3 October 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 408515
9 September 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 394965
4 February 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 387310
6 July 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 380080

Deficiency record · 16

Engineering › Fuel Oil Service System › Settler Tank
Issued 8 September 2010 Resolved
Fuel Oil Setting Tank - Fuel shut-off valve was fitted with a nut and bolt, keeping it from closing in the event of fire in the space.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2010
Resolution: Received class report clearing above deficiency.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 September 2010 Resolved
All doors leading to galley space are Class B doors not providing an equivalent level of protection against fire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 September 2010
Resolved 22 September 2010
Resolution: Received class report clearing above deficiency.
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 8 September 2010 Resolved
Main cable way Class A boundary cables were not maintained.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2010
Resolved 20 September 2010
Resolution: Received class report clearing above deficiency.
Lifesaving › Launching Appliances › Davit
Issued 8 September 2010 Resolved
Limit switch on the davit arms do not cut off power before the davit arms reach the stops.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 September 2010
Resolved 20 September 2010
Resolution: Received class report clearing above deficiency.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 September 2010 Resolved
Class A self closing doors in stairway would not fully close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 September 2010
Resolution: Doors were adjusted to close properly.
Engineering › Pressure Vessel › Pressure Gauge
Issued 28 January 2005 Resolved
Repair or renew secondary oil pressure gauge to incinerator. SOLAS 74amd I/II. 70A
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 March 2005
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 January 2005 Resolved
Prove proper operation of the oily water separator where the stage bone waste oil solinoid is hot due to fouled sensor. MARPOL 73/78 I and SOLAS 74 amd I/II. 70A.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 March 2005
Documentation › Certificates/Documents › IOPP Certificate
Issued 28 January 2005 Resolved
Amend block 3.1 of IOPP to reflect actual volume of B.S.O.T. is 8.64 m3 vice 7.0 m3 MARPOL 73/78 I. 70A.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 March 2005
Documentation › Logs/Records
Issued 15 May 2003 Resolved
Commence recording soundings on all waste oil tanks as per the instructions found in Appendix III of Annex. I of MARPOL 73/78. LEGACY COMPONENT DESC: Oil Record Book
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2003
Documentation › Certificates/Documents
Issued 15 May 2003 Resolved
Include the waste oil incinerator tank in block 3.1 of the IOPP Certificate. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2003
Documentation › Logs/Records
Issued 15 May 2003 Resolved
Commence recording all petroleum transfers in the oil record book where the period from 6 DEC 2000 through 12 MAY 2003 is recorded in only 45 pages (less than 1/2 of one book). LEGACY COMPONENT DESC: Oil Record Book
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2003
Personnel › Training
Issued 15 May 2003 Resolved
Update the new crew familiarization training check list to include the elements found in STCW A-VI/1 LEGACY COMPONENT DESC: Familiarization Training
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2003
Fire Fighting › Structural - A Class Divisions
Issued 15 May 2003 Resolved
Repair as original the door at main stair tower "A" deck and at upper entrance to steering room where the doors are blocked by the frame on the latch side due to bent hinges. LEGACY COMPONENT DESC: Openings - Doors
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 15 May 2003 Resolved
Perform maintenance on the semi - portable foam extinguisher near door to steering room in engine room where nozzle and hose has been plugged with dry foam. LEGACY COMPONENT DESC: Condition
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2003
Lifesaving › Inflatable Liferafts
Issued 15 May 2003 Resolved
Provide instructions for type of life raft on board vessel. This vessel has the one lanyard style rafts. LEGACY COMPONENT DESC: Instuction
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 June 2003
Construction/Loadline
Issued 11 December 1999 Resolved
REPAIR FRACTURES ON MAIN DECK ADJACENT TO HOLDS 2 AND 3 (#3 AND #4 PORT ANDSTARBOARD TOPSIDE WINGTANK MAN HOLE COVERS) AND PROVIDE CLASS REPORT ACCEPTING REPAIRS OR PROVIDE CLASS REPORT ACCEPTING FRACTURES IN MAIN DECK.CORRECT PRIOR TO DEPARTURE FROM THIS PORT.
Condition: Unknown
Due 14 December 1999
Resolved 21 December 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.