Records from 2007 to 2020. Most recent: inspection, 28 May 2020.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2020
Resolved
The owner or managing operator shall make the vessel available for drydock and internal structural examinations at least once every two years. The owner failed to conduct these exams by 30APR2020. The owner is required to successfully complete a drydock and internal structural exam prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2021
Resolution: Subchapter C vessel-no passenger for hire
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 May 2019
Resolved
The vessel did not have FCC station license, FCC safety cert, or FCC bridge to bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 18 June 2019
Resolution: FCC certs onboard
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 28 May 2019
Resolved
No record of enrollment in approved drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: Received email of proof of enrollment.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 28 May 2019
Resolved
There was no means to conduct alcohol testing within two hours on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 18 June 2019
Resolution: Test strips onboard
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 May 2019
Resolved
No tides and currents on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2019
Resolved 18 June 2019
Resolution: Onboard
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 May 2019
Resolved
Vessel's horn was not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2019
Resolved 18 June 2019
Resolution: Operational
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 May 2019
Resolved
Provide Type I life jacket donning placards
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 18 June 2019
Resolution: Placard provided
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 May 2019
Resolved
Fire pump leaked excessively around shaft seal, but hose had adequate pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 18 June 2019
Resolution: Pump renewed and satisfactory tested
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 May 2019
Resolved
Fire pump gauge was not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 18 June 2019
Resolution: Gauge renewed and tested
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 November 2018
Resolved
Vessel did not receive annual inspection within 90 days of COI anniversary date.
Action required: 10 - Deficiency Rectified
Resolved 20 November 2018
Resolution: Cleared on the spot since annual inspection was started.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 November 2018
Resolved
Crack was found on port steering post adjacent to keyway. Make repair proposal to CG and make repairs according to approved plan. (46 CFR 182.30-1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2019
Resolution: Renewed
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 20 November 2018
Resolved
Vessel installed and operated new crane on the stbd bow without approval from [name withheld] installation plans and stability calcs to MSC.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2019
Resolution: Received approval from MSC
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 November 2018
Resolved
All vessels of less than 100 GRT that operate more than 12 hours in a 24 hour period, shall be provided with an alternate crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2019
Resolution: Confirmed with owner hours of operation do not require alternate crew.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 20 November 2018
Resolved
The vessel was operating outside of the issued COI by not having enough serviceable immersion suits as required on the COI. Provide sufficient quantity of immersion suits to comply with COI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2019
Resolution: Verified immersion suits.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 November 2018
Resolved
Vessel did not have enough Type-I life jackets for each adult listed on the Certificate of Inspection. Provide correct number of life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2019
Resolution: Verified number of lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 November 2018
Resolved
Liquid level indicating gauges on fuel tanks were not protected from damages, did not have automatic closure in the event of rupture, and have locks on valve handles to lock in the open position. Provide proper arrangement for liquid level indicating gauges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 23 April 2019
Resolution: Verified proper arrangements for the liquid level indicator.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 November 2018
Resolved
Emergency escape hatch from engine room to weather deck is not watertight. Make hatch watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2019
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 November 2018
Resolved
Vessel has multiple batteries placed in the engine room with no cage or similar structure over the batteries. Provide proper arrangements for batteries. (46 CFR 183.05-20)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 6 March 2019
Resolution: Owner provided proper arrangement for batteries.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 November 2018
Resolved
Batteries are unsecured and located on a frame, low in the engine room. Relocate and secure batteries that are adjacent to the generators. (46 CFR 183.05-20)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 23 April 2019
Resolution: Batteries have been reloated into a tray and are secured.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 November 2018
Resolved
Vessel marked the wrong locations for the fuel shutoff stations. Mark the correct fuel shutoff stations.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 29 May 2019
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 November 2018
Resolved
Emergency escape from engine room is not marked. Clearly mark the exit in the engine room and outside of the exit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 6 March 2019
Resolution: Clearly marked the emergency exit.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 November 2018
Resolved
Containers for life jackets and immersion suits were not identified. Mark location with size and numbers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 23 April 2019
Resolution: Storage bin has been adequately marked.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 20 November 2018
Resolved
Remove excess flammable liquids from the engine room and store in a proper area.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2019
Resolution: Flammable liquids have been relocated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 November 2018
Resolved
Junction boxes in the engine room were found exposed. Ensure all junction boxes are covered. (46 CFR 183.10-20(k))
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 23 April 2019
Resolution: Junction boxes have been covered.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 November 2018
Resolved
Open areas in distribution panels must be blanked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 23 April 2019
Resolution: Open areas in panel have been blanked.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 November 2018
Resolved
All electrical equipment and circuits must be clearly marked and identified. Breakers were not labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 23 April 2019
Resolution: Breakers have been labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 November 2018
Resolved
Each generator is missing a voltmeter, an ammeter, and mean of measuring frequency. Provide the required gauges for each generator. (46 CFR 183.10-5)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 January 2019
Resolution: Owner energized existing gauges for inspector. All Sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 November 2018
Resolved
Fire axe is inoperable and needs to be renewed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 23 April 2019
Resolution: Fire axe has been replaced.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 20 November 2018
Resolved
The marine sanitation device has no label or evidence of certification. Provide evidence of MSD compliance.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 21 May 2021
Resolution: type III MSD onboard
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 November 2018
Resolved
Vessel did not have a first-aid kit that complied with 160.041 or an equivalent. Provide approved first-aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 23 April 2019
Resolution: New first aid kit had been purchased.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 November 2018
Resolved
Vessel did not have Certificate of Documentation available for inspection. Make Certificate of Documentation available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2019
Resolution: Vessel issued COD.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 November 2018
Resolved
Vessel did not have applicable up-to-date charts and nautical publications available. Make available for inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2019
Resolved 29 May 2019
Resolution: Corrected
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 November 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 January 2019
Resolution: Owner received FCC license and presented it to the inspector. All Sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 November 2018
Resolved
Vessel must complete satisfactory man overboard and fire drills as well as all operational tests require by the attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2019
Resolution: Conducted satisfactory drills.
Fire Fighting › Fire Pumps › Pressure
Issued 1 June 2017
Resolved
Replace inoperable fire pump gauge.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 29 June 2017
Resolution: new gauge installed
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 1 June 2017
Resolved
Clean out engine room bilges
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 29 June 2017
Resolution: bilges have been cleaned out
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 1 June 2017
Resolved
Provide current FCC safety radiotelephony and Bridge-to-Bridge Certificates
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 29 June 2017
Resolution: certs issued 6/22/17
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 1 June 2017
Resolved
Provide a log that contains: -crew training(185.420); -monthly epirb tests(185.728); -equipment maintenance checks(185.702)
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 29 June 2017
Resolution: Logs are not being kept properly
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 1 June 2017
Resolved
Prove proper operation on port main engine shutdown from bridge
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 29 June 2017
Resolution: Provide corrected/updated charts for areas of operation
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 19 May 2016
Resolved
Remove aerosols from beneath main engine exhaust, port side engine room.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: Aerosols removed prior to our departure.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 May 2016
Resolved
Install lagging on both generators at exhaust manifolds.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 20 June 2016
Resolution: New lagging installed.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 19 May 2016
Resolved
Install lights to lifejackets (restricted to limited coastwise route or less).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 20 June 2016
Resolution: Lights fitted to lifejackets.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 19 May 2016
Resolved
Provide tidal currents aboard vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 20 June 2016
Resolution: Vsl obtained tidal currents.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 May 2016
Resolved
Clean stbd rope locker in order to access emergency fuel shutoffs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: Stbd rope locker cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 19 May 2016
Resolved
Mark on outside of rope locker location of portable fire extinguisher within space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 20 June 2016
Resolution: Placard fitted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 19 May 2016
Resolved
Mount portable fire extinguisher in stbd rope locker in approved bracket.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 20 June 2016
Resolution: Proper bracket mounted.
Construction/Loadline › Hull › Hull Plating
Issued 21 April 2016
Resolved
Conduct belt gauging UT shots of the hull IWO #1 & #2 Fish Holds.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 19 April 2017
Resolution: Conducted UT shots that were in compliance
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 21 April 2016
Resolved
Draw Port and Starboard shafts for inspection of cutlass bearings.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 19 April 2017
Resolution: pulled shafts inspection of bearings found sat