Records from 2016 to 2025. Most recent: inspection, 15 July 2025.
Inspection history · 19
15 July 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8174003
24 July 2024
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7964631
30 August 2023
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7781144
19 July 2023
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7741535
14 July 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7497456
5 August 2021
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7276681
21 July 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7263414
7 August 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7026807
1 May 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6674377
15 March 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6643348
1 February 2019
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6618839
8 May 2018
DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6405305
12 May 2017
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6138382
2 March 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6097710
28 July 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5956269
25 May 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5886533
15 March 2016
COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5833493
8 January 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5886455
5 January 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5793911
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 July 2023
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and
lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges
must be readily visible at the operating station. No gauges for lube oil pressure or jacket water temperature were visible from the operating station.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2023
Resolved 30 August 2023
Resolution: Received email with pictures of installed gauges.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2023
Resolved
Each life jacket kept in a stowage container must be readily available. Stowage container near galley is difficult to open.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 25 July 2023
Resolution: Received pictures of handles installed on front of seats to aid in removing cover.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 August 2021
Resolved
Vessel unable to conduct drtills due to drydock status.
46CFR185.420(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2021
Resolved
Vessel unable to test machinery equipment due to vessels drydock status.
46CFR176.804
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 August 2021
Resolved
Vessel had dead end/ loose wires under bridge console.
46CFR183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2021
Resolved 12 August 2021
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 August 2021
Resolved
FCC Safety Radiotelephony Certificate not present onboard vessel.
47CFR47-80.59(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2021
Resolved 12 August 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 August 2020
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent should the local manual release or stop valve controls fail to operate. Each control valve to a distribution line.Required to replace current instruction with step by step instructions to deploy the system and the authority needed to deploy the system.
Also, required a schematic diagram at cylinder location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 2 September 2020
Resolution: Provided updated instructions and posted them.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 August 2020
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. After speaking with Captain, determined that they will have laminated checklists on
the bridge to cover these events. The checklists will better mimic what the students will see in the field.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 2 September 2020
Resolution: The checklists have been updated and are at the operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 August 2020
Resolved
Sight-flow glasses may be used in lubricating-oil systems provided it has been demonstrated, to the satisfaction of the Commanding Officer, Marine Safety Center, that they can withstand exposure to a flame at a temperature of 927 °C (1700 °F) for one hour, without failure or appreciable leakage. The lube oil sight-flow glass is plastic. Required to replace with a heat resistant material.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 2 September 2020
Resolution: Removed sight glass and the container it was attached to from vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 August 2020
Resolved
Ring life buoys shall be of first class workmanship and free from any defects materially affecting their appearance or serviceability. The plug on one of the ring life buoys is cracked. This is an extra ring life buoy; therefore giving a year to replace. Can also just remove the ring life buoy.
Action required: 705 - Other - as specified
Due 7 August 2021
Resolved 2 September 2020
Resolution: Removed ring buoy from vessel.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 7 August 2020
Resolved
General alarm bells shall be marked in not less than 1/2-inch red letters: “General Alarm - When Bell Rings Go to Your Station.” Ensure all general alarms are labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 2 September 2020
Resolution: Provided photo evidence of all alarms properly labeled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 August 2020
Resolved
An alarm for a fixed gas fire extinguishing system must be clearly and conspicuously marked “WHEN ALARM SOUNDS-VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED”. Where a different extinguishing agent is installed, that agent shall be marked in place of “carbon dioxide.” Required to label the time delay alarm in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 2 September 2020
Resolution: Provided photo evidence of compliance.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 February 2019
Resolved
Multiple areas of wasted were found in the fuel tank, hull, and bulkhead frames. Repair wasted area to the satification of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2019
Resolved 12 February 2019
Resolution: Completed repairs
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 8 May 2018
Resolved
Child PFD placard not posted. 46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2018
Resolution: New placard posted.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 8 May 2018
Resolved
Demonstrate MDE shutdowns for low lube oil and engine speed.
46 CFR 58.05-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2018
Resolved 13 June 2018
Fire Fighting › Fire Hoses › Condition
Issued 12 May 2017
Resolved
01 fire hose damaged/leaking and 01 fire hose not on board. As per 46 CFR 181.15-10, one length of fire hose shall be provided for each fire hydrant. Replace 02 fire hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2017
Resolution: Replaced 02 new fire hoses.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 May 2017
Resolved
01 ring buoy waterlight battery dead, rendering waterlight ineffective. As per 46 CFR 180.30-1(b), replace waterlight battery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2017
Resolution: Replaced battery with new.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 May 2017
Resolved
Port and starboard exhaust hose missing 2nd hose clamp. As per 46 CFR 182.15-20(c), install hose clamps as necessary.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 8 June 2017
Resolution: Additional clamps installed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 May 2017
Resolved
Ring buoy retro-reflective tape going worn away. As per 46 CFR 160.050-4(f), ring life buoys shall be free from any defects materially affecting their appearance. 46 CFR 180.30-1(a)
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 8 June 2017
Resolution: Retro-reflective tape renewed.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 12 May 2017
Resolved
Fuel vent, discharge end missing flame screen. As per 46 CFR 182.20-35(d), the discharge end of vent pipes shall be fitted with removable flame screens or flame arrestors. Install flame screen at discharge end.
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 8 June 2017
Resolution: Vent in question not a fuel tank vent. Vent for galley drain, deficiency issued in error.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 May 2017
Resolved
02 dead end wires and 01 junction box missing cap in forward passenger compartment. As per 46 CFR 183.01-15(a), all electrical installations shall be to the satisfaction of the [name withheld] cap on junction box and place dead end wires into junction box.
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 8 June 2017
Resolution: Dead end wiring properly terminated, junction box renewed.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 12 May 2017
Resolved
Adult and child lifejackets not stored separately. 46 CFR 180.25-10(c) says life preservers for children, when provided, shall be stowed separately. Stow separatly.
Action required: 705 - Other - as specified
Resolved 12 May 2017
Resolution: Corrected on the spot.
Stability › Watertight Integrity › General
Issued 12 May 2017
Resolved
Aft light penetrating hull transom above waterline not watertighet. As per 46 CFR 176.25-5 hull penetrations must be made watertight. Make aft light penetration watertight.
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 8 June 2017
Resolution: Light fixture made tight.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 March 2016
Resolved
COI expired 07JAN16. Vessel opperated approximately 17 times since expiration. New COI will be issued when No Sail 835 for the Bilge system is cleared. Vessel is restricted to the pier, Investigators have been notified.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2016
Resolved
Fresh Water Pump was found to be wired with no tuffing tube and to be grounded to the bulkhead of the E/R. This is unlike any other pump in the E/R. Vessel must prove that this is proper installation to attending Marine Inspector. 46CFR183.200
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 25 March 2016
Resolution: Pump rewired to manfacturers instruction.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 March 2016
Resolved
On aft E/R bulkhead there is wiring connections in between battery banks, terminals for these connection were found to be freyed and need to be renewed. 46CFR183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 25 March 2016
Resolution: Wireing connections renwed to the satifaction of attending Marine Inspector.
Engineering › Bilge Water Management System › Piping
Issued 15 March 2016
Resolved
Bilge Forward of E/R could not take suction fom spaces.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2016
Resolution: The leak was the result of a leaking fitting. All parts were removed and reinstalled. Bilge system FWD of E/R was able to take suction.