← All vessels
WEEKS 227
Tank Barge · Barge class · Built 1950s · USCG Southeast District (CGD-SE) · Other hulls named WEEKS 227
WEEKS 227 is a 1952 tank barge. The Coast Guard has recorded 22 inspections since 1984, most recently in March 1994, along with 16 deficiencies.
Records from 1984 to 1994. Most recent: inspection, 3 March 1994.
- Built
- 1952
- Last inspected
- 3 March 1994
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
263371
42728
Flag
UNITED STATES
—
Maury page id
psix-42728
Inspections, by type
…with no type recorded4
Years with a record
10 calendar years (1984–1994)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it77 - Regulatory (Subpart C or D), Net Ton
77 - Regulatory (Subpart C or D), Gross Ton
77 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
3 March 1994
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1163482
6 August 1992
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1259057
1 May 1992
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 960843
8 July 1991
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1243915
19 June 1991
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 891556
2 May 1990
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1213228
27 March 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 896567
9 September 1988
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 890557
23 March 1988
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296509
3 March 1988
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1339155
1 July 1987
Drydock Extension
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1317864
18 May 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1331824
30 March 1987
MARPOL Annex II Examination · Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1004635
6 May 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 988009
7 March 1986
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 988629
8 November 1985
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1293099
10 October 1985
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1295185
16 August 1985
Credit Drydock
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1293090
10 June 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1286480
24 April 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1289223
5 March 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982451
8 March 1984
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 977742
Deficiency record · 16
Deck/Cargo
Issued 1 May 1992
Resolved
INSTALL EMERGENCY SHUTDOWN ON PUMP ENGINE._x001C_ NO CARGO OPERATIONS ALLOWED UNTIL COMPLETED.
Navigation
Issued 1 May 1992
Resolved
REMOUNT PORT RUNNING LIGHT STANCHION.
Deck/Cargo
Issued 1 May 1992
Resolved
INSTALL SPARK ARRESTOR ON PUMP ENGINE EXHAUST._x001C_ NO CARGO OPERATIONS ALLOWED UNTIL COMPLETED.
Deck/Cargo
Issued 19 June 1991
Resolved
HYDROSTATICALLY TEST AND STENCIL THE CARGO PIPING AND TRANSFER HOSES AT MAXWORKING PRESSURE._x001C_ _x001C_ _x001C_
Documentation
Issued 3 March 1988
Resolved
REPAINT VESSEL NAME AND HOMEPORT ON STERN PRIOR TO GETTING UNDERWAY.
Deck/Cargo
Issued 3 March 1988
Resolved
STENCIL CARGO HOSE WITH DATE AND TEST PRESSURE PRIOR TO CONDUCTING CARGO OPERATIONS.
Fire Fighting
Issued 3 March 1988
Resolved
PROVIDE 2 B-II CG APPROVED MARINE TYPE FIRE EXTINGUISHERS ON BOARD PRIOR TOCONDUCTING CARGO OPERATIONS.
Electrical
Issued 3 March 1988
Resolved
SECURE CARGO PUMP BATTERY.
Electrical
Issued 3 March 1988
Resolved
RENEW NEGATIVE BATTERY CABLE CONNECTION AT ENGINE.
Documentation
Issued 3 March 1988
Resolved
PLACE ORIGINAL FMC CERTIFICATE ONBOARD PRIOR TO CONDUCTING CARGO OPERATIONS.
Construction/Loadline
Issued 3 March 1988
Resolved
MAKE RAKES AND CENTER VOID AVAILABLE FOR INSPECTION.
Deck/Cargo
Issued 30 March 1987
Resolved
CONDUCT TEST ON CARGO PIPING AS REQUIRED BY 33 CFR 156.170.
Deck/Cargo
Issued 7 March 1986
Resolved
INSTALL SECTION OF CARGO SUCTION PIPE LOCATED AT FIRST STRAIGHT SECTION OFFPUMP TO COMPLY WITH 46 CFR 32.50-15(A)(2). SECTION OF PIPE TO BE REPLACED IS APPROXIMATELY 2' LONG. VESSEL NOT TO BE PLACED IN SERVICE UNTIL THIS REQUIREMENT IS COMPLETED.
Construction/Loadline
Issued 16 August 1985
Resolved
INSERTED NEW PLATE 1' X 15' IN WAY OF FORWARD RAKE KNUCKLE WHERE ULTRASONICGAGING SHOWED PLATE THICKNESS BELOW MINIMUM REQUIRED.
Deck/Cargo
Issued 24 April 1985
Resolved
HAVE CARGO PIPING MODIFICATIONS SHOWN ON DWG 704100 ALT 1 APPROVED BY CCGD3 (MMT) ON 18 APR 1985 INSPECTED BY A COAST GUARD MARINE INSPECTOR PRIOR TO PLACING INTO SERVICE.
Construction/Loadline
Issued 5 March 1985
Resolved
MARK DRAFT MARKS AS REQUIRED BY 46 CFR 32.05-1 AT NEXT DRYDOCKING.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National