MAURY USCG vessel records Sign in
← All vessels

SPIRIT OF PALM BEACH

SPIRIT OF PALM BEACH is a 1995 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 1996, most recently in August 2016, along with 76 deficiencies — 1 with no resolution recorded —.

Records from 1996 to 2016. Most recent: inspection, 3 August 2016.

Built
1995
Last inspected
3 August 2016
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE2030
427407
Flag
UNITED STATES
367319420 (licence lapsed)
Maury page id
psix-427407

Inspections, by type

…with no type recorded8
Years with a record 15 calendar years (1996–2016)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.9 ft × 22.0 ft × 5.7 ft
Registered tonnagegross 54 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLADY M CHARTERS INC · FT LAUDERDALE, FL, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPALM BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Simplified, Gross Ton
43 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE2030MMSI 367319420 · expired · compulsorily equipped · granted 24 October 2007, cancelled 30 December 2017
WCW7730MMSI not assigned · expired · compulsorily equipped · granted 30 July 1996, cancelled 30 September 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 37

3 August 2016 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5961223
30 August 2011 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4130870
2 December 2009 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3644572
27 April 2009 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3462304
1 May 2008 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3196258
8 January 2008 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3126560
19 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3118103
14 December 2007 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3115476
29 September 2006 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2789784
19 January 2006 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2569319
25 April 2005 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2342001
28 April 2004 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2053938
5 March 2004 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1932757
23 October 2003 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1943233
3 October 2003 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1920498
10 April 2003 COI Inspection · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1771343
10 September 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1373610
8 May 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 817873
22 September 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1193930
1 July 1999 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1423213
9 April 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1126827
25 February 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1429088
11 December 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1409993
30 July 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 205047
30 July 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 763853
15 July 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1368806
10 March 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 788026
20 February 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 778657
9 January 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 785627
29 December 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 785234
23 October 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 784223
9 September 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1121851
29 November 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 873663
18 September 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 840259
24 June 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1089865
24 May 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 840256
12 March 1996 Inclining Experiment
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 840258

Deficiency record · 76

Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 30 August 2011 No resolution recorded
Vessel operating with expired Certificate of Documentation IAW 46 CFR 67.317.
Action required: 705 - Other - as specified
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 2 December 2009 Resolved
Make vessel available for sea trials with Coast guard inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2010
Engineering › Bilge Water Management System › Hose
Issued 27 April 2009 Resolved
Remove disconnected overboard discharge hose and mechanically secure overboard fitting on starboard side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2009
Resolved 27 April 2009
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 April 2009 Resolved
Provide additional fifteen adult lifejackets onboard. Personnel onboard are limited to one hundred forty three (143) until provided.
Action required: 705 - Other - as specified
Resolved 30 April 2009
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 27 April 2009 Resolved
Remove all flammables and combustables from stowage area.
Action required: 705 - Other - as specified
Due 11 May 2009
Resolved 26 January 2010
Construction/Loadline › Structures › Superstructure
Issued 27 April 2009 Resolved
Remove carpet and provide repair proposal for main deck and area of wasted house in way of starboard side engineroom vent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2009
Resolved 26 January 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 December 2007 Resolved
Vessel operated four times after the required deadline of a required annual inspection. Vessel should have completed a annual inspection no later than 17 July 2007.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 December 2007
Resolved 28 May 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 December 2007 Resolved
Renew port and starboard exhaust pipes from exhaust collection boxes on both main engines and benerators, continuing aft through lazerette to transom plate; additionally the pipe from the main generator to the collection box shall be renewed. All pipes shall be schedule 80. Full penetration welds shall be utilized. CG inspector shall witnes fit-up.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2007
Resolved 28 May 2008
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 14 December 2007 Resolved
Provide and install non conductive matting in front of generator panel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 December 2007
Resolved 28 May 2008
Electrical › Electrical Distribution System (service) › Switchboard
Issued 14 December 2007 Resolved
Provide and install drip shield on generator panel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 December 2007
Resolved 28 May 2008
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 14 December 2007 Resolved
Generator rated for 40 degree Celsius ambient temperature. Generator must be derated at main circuit breaker to 80% capacity.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 December 2007
Resolved 28 May 2008
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 December 2007 Resolved
Provide and install a main breaker interlock to prevent two breakers from being closed simultaneously.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 December 2007
Resolved 28 May 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 December 2007 Resolved
Properly blank off and close all openings in generator panel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 December 2007
Resolved 28 May 2008
Communications › Public Address System › Broadcast Location
Issued 14 December 2007 Resolved
Provide public address system operable from control station.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 December 2007
Resolved 8 January 2008
Documentation › Markings/Placards › Capacity Marking
Issued 14 December 2007 Resolved
Label upper deck capacity in a conspicuous location.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 December 2007
Resolved 8 January 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 September 2006 Resolved
Properly repair bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2006
Resolved 2 November 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 29 September 2006 Resolved
Crop out and renew wasted exhaust pipe from generator located in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 28 May 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 29 September 2006 Resolved
Proerly blank off two holes in aft bulkhead of eingine room on port side at bottom near hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 2 November 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 September 2006 Resolved
Install guards over rotating machinery in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 2 November 2006
Construction/Loadline › Structures › Ventilators
Issued 29 September 2006 Resolved
Properly repair ventilation fan in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 2 November 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 September 2006 Resolved
Properly mount and install wiring to and for vent fan in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 2 November 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 September 2006 Resolved
Remove all wire nut connectors and reconnect with pressure type wire connectors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 2 November 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 September 2006 Resolved
Renew name on ring buoy at the pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 2 November 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 September 2006 Resolved
Renew 60 ft of life line on ring buoy at pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 2 November 2006
Documentation › Markings/Placards › Capacity Marking
Issued 29 September 2006 Resolved
Properly label 01 deck fwd life jacket stowage locker with quantity of jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 2 November 2006
Documentation › Markings/Placards › Lifejacket Placard
Issued 29 September 2006 Resolved
Properly mount and display life jacket donning placard near main deck life jacket stowage and 01 deck stowage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 2 November 2006
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 September 2006 Resolved
Provide proof of EAP training.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 2 November 2006
Fire Fighting › Fire Pumps › Pressure
Issued 29 September 2006 Resolved
Demonstrate fire pump will provide 50 gpm at 60 psi.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2006
Resolved 2 November 2006
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 19 January 2006 Resolved
Renew wasted generator exhaust pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 December 2006
Resolved 2 November 2006
Construction/Loadline › Hull › Bottom Plating
Issued 19 January 2006 Resolved
Provide belt gaging report from stem to stern and beam to beam starting at the waterline with ultrasonic readings taken no more than 12 inches apart.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2006
Resolved 27 March 2006
Construction/Loadline › Hull › Bottom Plating
Issued 19 January 2006 Resolved
Crop out and renew all plate area identified by marine inspector and insert new plate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 3 April 2006
Documentation › Certificates/Documents
Issued 28 April 2004 Resolved
Operating a vessel with an expired Certificate of Documentation since April 1, 2004, obtain new Certificate prior to operating vessel, IAW 46CFR67.317. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 28 April 2004
Resolved 29 April 2004
Documentation › Certificates/Documents
Issued 28 April 2004 Resolved
Post stability letter in the operating station, IAW 46CFR176.308, prior to 7May04. LEGACY COMPONENT DESC: Stability Letter
Due 7 May 2004
Resolved 27 May 2004
Personnel › Training › Fire Fighting Basic
Issued 28 April 2004 Resolved
Post emergency instruction in operating station, IAW 46CFR185.510, prior to 7May04.
Due 7 May 2004
Resolved 27 May 2004
Lifesaving › Embarkation Appliances/Stations
Issued 28 April 2004 Resolved
Install a backing plate for the bolts at the hull for the man overboard platform/ladder, IAW 46CFR182.520(7), prior to 7May04.
Due 7 May 2004
Resolved 27 May 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 April 2004 Resolved
Provide self-activating water light for ring buoy, IAW 46CFR180.70, prior to carrying passengers.
Due 28 April 2004
Resolved 29 April 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 28 April 2004 Resolved
Provide annual servicing for fixed fire extinguisher service, IAW 46CFR176.810, prior to 30April04.
Due 30 April 2004
Resolved 29 April 2004
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 28 April 2004 Resolved
Provide annual servicing for all portable fire extinguishers, IAW 46CFR176.810, prior to 30April04.
Due 30 April 2004
Resolved 29 April 2004
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 28 April 2004 Resolved
Provide up to date tide and current tables, IAW 184.420, prior to 7May04.
Due 7 May 2004
Resolved 27 May 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 April 2004 Resolved
Install not under command lights, IAW COLREGS rule 27, prior to 7May04.
Due 7 May 2004
Resolved 27 May 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 28 April 2004 Resolved
Provide emergency broadcast placard and post near the VHF radio IAW 46CFR184.506, prior to 7May04.
Due 7 May 2004
Resolved 27 May 2004
Engineering › Bilge Water Management System › Pump
Issued 28 April 2004 Resolved
Provide a portable bilge pump capable of reaching the bottom of all compartments and pumping at least 5 gallons per min., IAW 46CFR182.520, prior to 7May04.
Due 7 May 2004
Resolved 27 May 2004
Engineering › Bilge Water Management System › Valve
Issued 28 April 2004 Resolved
Install a positive shutoff valve for bilge pumps at the thru-hull fitting at the highest point, IAW 46CFR176.816, prior to 7May04.
Due 7 May 2004
Resolved 27 May 2004
Operations/Management › Passenger Operations
Issued 28 April 2004 Resolved
Mark upper deck with maximum number of passengers that may be on that deck, 95 passengers, IAW 46CFR185.602, prior to 7May04.
Due 7 May 2004
Resolved 27 May 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 28 April 2004 Resolved
Provide a bulb and cover for the ceiling light on the main deck, IAW 46CFR183.410, prior to 7may04.
Due 7 May 2004
Resolved 27 May 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 April 2004 Resolved
Replace battery in emergency lighting on main deck port side, IAW 46CFR183.432.
Due 7 May 2004
Resolved 27 May 2004
Electrical › Lighting (service) › Lighting Feeder
Issued 28 April 2004 Resolved
Properly splice all electrical wiring for upper deck lighting, IAW 46CFR183.340, prior to 7May04.
Due 7 May 2004
Resolved 27 May 2004
Electrical › Electric Supply System (service) › Cable
Issued 28 April 2004 Resolved
In all engineering spaces support overhead wiring with metal supports every 24 inches.
Due 7 May 2004
Resolved 27 May 2004
Documentation › Certificates/Documents
Issued 10 April 2003 Resolved
Radio Telehony Certificate LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 May 2003
Resolved 23 October 2003
Navigation › Piloting/Steering
Issued 10 April 2003 Resolved
Provide compasS deviation table. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 May 2003
Resolved 23 October 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 10 April 2003 Resolved
Provide flame bowl for geneator fuel filter.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2003
Resolved 23 October 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 10 April 2003 Resolved
Newly installed primary generator shall only be used in emergencies until leak in the exhaust is repaired.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 23 October 2003
Construction/Loadline
Issued 25 February 1999 Resolved
PROVIDE PROPER REPAIR (REMOVE DOUBLERS) IN WAY OF ALL WATERTIGHT BULKHEAD MOUSEHOLES.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Documentation
Issued 25 February 1999 Resolved
PROVIDE VALID FCC SAFETY RADIO-TELEPHONY CERTIFICATE.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Engineering
Issued 25 February 1999 Resolved
PROVIDE BONDING WIRE IN WAY OF BOTH FUEL VENTS.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Lifesaving
Issued 25 February 1999 Resolved
PROVIDE MEANS OF RECOVERING INCAPACITATED VICTIM FROM WATER IAW 46CFR180.210.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Engineering
Issued 25 February 1999 Resolved
PROVIDE PROPER FITTINGS AND ACCEPTED HOSE IN WAY OF FUEL TANK CROSS FEED ORREPLACE IN LIKE QUALITY AND KIND IAW APPROVED PLANS. REPAIR PORT FUEL SHUT OFF VALVE LEAK.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Fire Fighting
Issued 25 February 1999 Resolved
PROVIDE FIXED EXTINGUISHING SYSTEM IAW 46CFR181.400 DUE TO WOODEN OVERHEAD IN E/R.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Electrical
Issued 25 February 1999 Resolved
REMOVE WIRE NUTS AND PROVIDE PROPER CONNECTION IN WAY OF STARBOARD MDE BATTERY BOX.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Electrical
Issued 25 February 1999 Resolved
PROVE PROPER OPERATION OF MACHINERY SPACE EMERGENCY LIGHTS.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Documentation
Issued 25 February 1999 Resolved
PROVIDE PROOF OF ENROLLEMENT IN MARITIME CONSORTIUM.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Construction/Loadline
Issued 11 December 1998 Resolved
REMOVE EXISTING BOTTOM COATING SYSTEM TO WHITE METAL AND REPLACE IAW STANDARD MARINE PRACTICE PRIOR TO REFLOATING THE VSL AT PHASE IV HAUL OUT.
Condition: Unknown
Due 11 December 1998
Resolved 11 December 1998
Construction/Loadline
Issued 29 December 1997 Resolved
INSTALL HIGH BILGE ALARM IN EACH WATERTIGHT COMPARTMENT PRIOR TO SAILING.
Condition: Unknown
Due 9 January 1998
Resolved 12 January 1998
Electrical
Issued 29 December 1997 Resolved
LABEL ALL ELECTRICAL PANELS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1997
Resolved 29 December 1997
Lifesaving
Issued 29 December 1997 Resolved
PROVIDE 24 ADDITIONAL ADULT LIFE JACKETS. TOTAL PERSONS REDUCED TO 134 (1 MASTER, 2 DECKHANDS, 6 OTHER CREW, 125 PASSENGERS) UNTIL 158 ADULT LIFEJACKETS ONBOARD.
Condition: Unknown
Due 29 December 1997
Resolved 29 December 1997
Documentation
Issued 29 December 1997 Resolved
PROVIDE DOCUMENTATION OF CURRENT LICENSED CREW ENROLLMENT IN CONSORTIUM.
Condition: Unknown
Due 29 December 1997
Resolved 29 December 1997
Documentation
Issued 29 December 1997 Resolved
POST COPY OF STABILITY LETTER.
Condition: Unknown
Due 9 January 1998
Resolved 12 January 1998
Navigation
Issued 29 December 1997 Resolved
DOUBLE-NUT OR COTTER PIN STEERING GEAR BOLTS.
Condition: Unknown
Due 29 December 1997
Resolved 29 December 1997
Electrical
Issued 29 December 1997 Resolved
REMOVE GEAR STOWED AGAINST HOT WATER HEATER.
Condition: Unknown
Due 9 January 1998
Resolved 12 January 1998
Lifesaving
Issued 29 December 1997 Resolved
INSTALL RETRO TAPE AND PROPERLY MOUNT RING BUOY.
Condition: Unknown
Due 9 January 1998
Resolved 12 January 1998
Documentation
Issued 24 June 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Documentation
Issued 24 June 1996 Resolved
EXTEND ONE MACHINERY VENT TO JUST ABOVE THE BILGE.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Documentation
Issued 24 June 1996 Resolved
PERMANENTLY MOUNT VHF RADIO.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Documentation
Issued 24 June 1996 Resolved
PROVIDE PROOF OF INITIAL CONSTRUCTION AND CREDIT DRYDOCK EXAMS.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Documentation
Issued 24 June 1996 Resolved
PROVIDE VENT FOR FOREPEAK.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Documentation
Issued 24 June 1996 Resolved
POST A COPY OF THE STABILITY LTR.
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996