MAURY USCG vessel records Sign in
← All vessels

LETA J

LETA J is a 1952 commercial fishing vessel. The Coast Guard has recorded 21 inspections since 1985, most recently in June 2012, along with 15 deficiencies and 1 casualty investigation in 2010.

Records from 1985 to 2012. Most recent: inspection, 3 June 2012.

Built
1952
Last inspected
3 June 2012
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC3978
Flag
UNITED STATES
367017320 (licence lapsed)
Maury page id
psix-42745

Inspections, by type

…with no type recorded3
Years with a record 14 calendar years (1985–2012)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)35.2 ft × 11.9 ft × 4.2 ft
Registered tonnagegross 15 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARL JOHNSON · NEWPORT BEACH, CA, UNITED STATES · built 1952
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBANDON, OR
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Net Ton
15 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC3978MMSI 367017320 · expired · compulsorily equipped · granted 10 February 2005, cancelled 18 April 2015
WCQ6728MMSI not assigned · expired · compulsorily equipped · granted 6 April 1995, cancelled 11 June 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 21

3 June 2012 Type not recorded
No type recorded · USCGC FIR (WLB 213) · USCG Northwest District (CGD-NW) · Activity 4340960
15 March 2004 Type not recorded
No type recorded · USCGC STEADFAST (WMEC 623) · Activity 2051059
23 January 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1463198
17 October 1995 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1191390
2 June 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 874443
9 May 1995 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382958
19 May 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 860806
19 April 1994 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403766
6 April 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 856091
19 May 1993 Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1366847
24 March 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1148420
28 September 1992 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 952458
13 May 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1261100
22 April 1991 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 908291
25 April 1990 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 906696
30 March 1989 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1350471
14 April 1988 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1343522
26 May 1987 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1310315
16 April 1987 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1331655
16 April 1986 Re-Inspection · Credit Drydock
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1308489
19 April 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1289367

Deficiency record · 15

Construction/Loadline
Issued 23 January 1996 Resolved
Renew entire stem in like kind and quality as original (not as currently configured). Intermediate & final stages of repair are to be made available for CG inspection. Vessel may not operate until completed.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 23 January 1996 Resolved
Remove 8 floor bolts for Coast Guard inspection, 4 each from port and starboard sides, stern to bow, evenly spaced.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 23 January 1996 Resolved
Conduct seatrials/underway examinations at termination of drydock work.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 23 January 1996 Resolved
Install double hose clamps on all through hull fittings._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 9 May 1995 Resolved
PROVIDE PHOTOGRAPHIC EVIDENCE OF PROPER POSTING OF A MARPOL V - PLASTICS PLAN PLACARD. TO BE COMPLETED NLT 19MAY95 AND TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Lifesaving
Issued 9 May 1995 Resolved
PROVIDE PHOTOGRAPHIC EVIDENCE OF PROPER POSTING OF LIFERAFT LAUNCHING INSTRUCTION PLACARD. TO BE COMPLETED NLT 19MAY95 AND TO THE SATISFACTION OFTHE COGNIZANT OCMI.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Lifesaving
Issued 9 May 1995 Resolved
PROVIDE PHOTOGRAPHIC EVIDENCE OF PROPER POSTING OF PFD DONNING INSTRUCTION PLACARD. TO BE COMPLETED NLT 19MAY95 AND TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Construction/Loadline
Issued 19 April 1994 Resolved
AT NEXT DRY DOCK EXAM, PULL A PLANK AT THE WIND AND WATER AREA FOR THE INSPECTION OF THE FASTENERS.
Condition: Unknown
Due 19 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 19 April 1994 Resolved
TEST MAIN ENGINE AND PROVIDE DOCUMENTATION TO MSO PORTLAND, OREGON THAT THETEST WAS SATISFACTORILY COMPLETED.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Construction/Loadline
Issued 19 April 1994 Resolved
TEST BILGE SYSTEM AND PROVIDE DOCUMENTATION TO MSO PORTLAND, OREGON THAT THE TEST WAS SATISFACTORILY COMPLETED.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Construction/Loadline
Issued 19 April 1994 Resolved
CONDUCT UNDERWAY TEST OF VESSEL TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Navigation
Issued 19 April 1994 Resolved
TEST ELECTRONIC EQUIPMENT AND PROVIDE DOCUMENTATION TO MSO PORTLAND, OREGONTHAT THE TEST WAS SATISFACTORILY COMPLETED.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Construction/Loadline
Issued 28 September 1992 Resolved
REPAIR ROT IN CABIN SIDE NEAR TOP ON BOTH SIDES. PORT SIDE MID TO AFT._x001C_ STARBOARD SIDE IN HEAD.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Construction/Loadline
Issued 16 April 1987 Resolved
CONDUCT SEA TRAIL TO COMPLETE DRYDOCKING.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Lifesaving
Issued 16 April 1987 Resolved
REPLACE DETERIORATED LIFE RING.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987

Casualty record · 1

17 August 2010Routine · role: Involved in a Marine Casualty · activity 3827593
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.