Inspections, by type

…with no type recorded3
Years with a record 22 calendar years (1995–2025)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it272 - Convention (Subpart B), Gross Ton
71 - Regulatory (Subpart C or D), Gross Ton
81 - Convention (Subpart B), Net Ton
48 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCU2309MMSI 366693520 · expired · compulsorily equipped · granted 18 July 2015, cancelled 20 September 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 36

6 August 2025 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8203637
15 October 2020 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7077728
16 December 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6875353
18 November 2019 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6863642
11 September 2018 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6539417
21 August 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6518171
18 October 2017 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6289989
12 August 2017 Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6243186
10 August 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6235557
8 November 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6037730
30 November 2015 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5772063
5 October 2015 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5735482
20 September 2011 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4149367
9 December 2010 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3907662
4 December 2008 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3364674
7 November 2007 Administrative Inspection · Plan Review "T" Boat · In-Service Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3138902
11 September 2007 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3078497
2 September 2005 Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2481642
29 September 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2208406
22 June 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2106601
6 October 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1923739
9 September 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1901601
4 September 2003 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1896503
1 August 2002 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1653727
4 September 2001 Re-Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1465687
18 October 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 823933
3 October 2000 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1469640
3 September 1999 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1442953
5 August 1999 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1471204
13 November 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 767961
26 October 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 197006
6 October 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465997
8 September 1997 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1368382
7 August 1996 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1411351
8 August 1995 COI Inspection · Initial Construction-Excluding Oversight · Hull Examination · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1443617
12 June 1995 Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1424119

Deficiency record · 10

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2018 Resolved
Man overboard Port Side. Crew demonstrated insufficient training and knowledge of the emergency procedures and equipment. Extended due to Sector NOLA availability due to Tropical Storm Gordon.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2018
Resolved 11 September 2018
Resolution: Got underway to conduc MOB drill. All sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 August 2018 Resolved
Generator room bulkhead lacked watertight integrity leading to engine room through hull penetration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2018
Resolved 27 August 2018
Resolution: Vessel rep provided photographic evidence of proper seal with new block and approved sealant for watertight penetration.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 2 September 2005 Resolved
Make repairs to visual indication on bridge for high level water alarms. All audible alarms - SAT. 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 21 September 2005
Construction/Loadline › Hull
Issued 4 September 2003 Resolved
Repair overhead swash bulkhead weld fracture, stbd water tank #2 LEGACY COMPONENT DESC: Weld
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 9 September 2003
Resolution: Owner repaired swash bulkhead weld fracture.
Lifesaving
Issued 3 October 2000 Resolved
Replace battery in waterlight attached to type I pfd.
Condition: Unknown
Due 3 October 2000
Resolved 17 October 2000
Accommodation/Occupational Safety
Issued 3 October 2000 Resolved
Label/stencil lifefloat paddles and ring lifebouys with name of vessel and label/stencil emergency exits and remote fuel/oil shutoffs. Label and stenciling weathered/worn.
Condition: Unknown
Due 3 October 2000
Resolved 17 October 2000
Electrical
Issued 3 October 2000 Resolved
Repair, test and place port generator on line.
Condition: Unknown
Due 3 October 2000
Resolved 17 October 2000
Accommodation/Occupational Safety
Issued 3 October 2000 Resolved
Ensure proper operation of forward emergency exit escape hatch. Hatch difficult to open.
Condition: Unknown
Due 3 October 2000
Resolved 17 October 2000
Navigation
Issued 3 October 2000 Resolved
Replace/update navigation rule book.
Condition: Unknown
Due 3 October 2000
Resolved 17 October 2000
Navigation
Issued 3 October 2000 Resolved
Permanently mount suitable magnetic compass designed for marine use at the primary operating station. Magnetic compass not mounted.
Condition: Unknown
Due 3 October 2000
Resolved 3 October 2000

Ownership record