Records from 1995 to 2025. Most recent: inspection, 18 November 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 41
18 November 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8270482
16 January 2025
Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8064599
4 November 2024
Administrative Inspection · COI Inspection · Special Consideration
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8026287
4 November 2024
Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8029406
4 January 2024
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7845238
6 November 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7821265
26 January 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7627471
1 November 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7587392
9 November 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7348647
25 January 2021
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7130364
2 November 2020
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7090121
13 January 2020
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6886778
1 May 2019
Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6675523
23 January 2019
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6615119
14 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580501
25 April 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6395619
29 March 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6113759
9 January 2017
Deficiency Check · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6065934
24 February 2016
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5815257
10 January 2011
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3923891
14 January 2009
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3391503
18 August 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3297528
31 January 2007
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2864595
13 June 2006
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2678520
7 June 2005
Hull Examination · Deadweight Survey · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2382275
28 March 2005
Examination of Repairs
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2321612
19 May 2004
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2100060
16 April 2004
Drydock Extension
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2045135
7 August 2003
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1869615
24 May 2002
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1621727
6 May 2002
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1613305
25 April 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1399600
26 May 2000
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1406786
21 June 1999
Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 879966
15 April 1999
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393226
20 April 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1364699
1 April 1997
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1411452
24 January 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1101403
2 July 1996
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1451081
21 June 1996
Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1081563
12 July 1995
Hull Examination · Initial Certification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1183542
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 May 2019
Resolved
Remove dead end wiring in the operating console.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 15 May 2019
Resolution: Dead end wire removed, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 May 2019
Resolved
Provide current first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 15 May 2019
Resolution: Provided new first aid kit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 May 2019
Resolved
Provide updated Tide Tables and Light List.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 15 May 2019
Resolution: Updated 2019 tide tanle onboard.
Construction/Loadline › Hull › Transverse Frame
Issued 9 January 2017
Resolved
Seperate the deck from the Pontoons and reweld all cracked welds on transverse frames.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 23 January 2017
Resolution: Witnessed
Construction/Loadline › Hull › Transverse Frame
Issued 9 January 2017
Resolved
Renew the cross member 4" channel/transverse frame. 3rd from the stern of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 23 January 2017
Construction/Loadline › Hull › Weld
Issued 9 January 2017
Resolved
Renew multiple cracked welds.
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 23 January 2017
Resolution: Witnessed
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 February 2016
Resolved
Replace 4 condemned life Jackets.
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 7 March 2016
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 24 February 2016
Resolved
Renew the reflective material/tape on 15 Life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2016
Resolved 7 March 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 August 2008
Resolved
Provide current U.S. Coast Pilot, and Coast Guard LIght List for vessel.
Due 18 September 2008
Resolved 18 September 2008
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 18 August 2008
Resolved
Ensure proper operation of all remote cut off valves for bilge pumps.
Due 18 September 2008
Resolved 18 September 2008
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 18 August 2008
Resolved
Remove water from battery boxes, and provide covers for batteries.
Due 18 September 2008
Resolved 18 September 2008
Engineering › Bilge Water Management System › Valve
Issued 31 January 2007
Resolved
Electric submersible bilge pumps and required shut off valves are located in voids of port and starboard pontoon hulls that are not readily accessible. Provide suitable means (reach rod, hatch plate, etc) to access each electric submersible bilge pump shut off valves from the main deck. (46 CFR 176.800)(46 CFR 182.500(e)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2007
Resolved 18 September 2008
Documentation › Markings/Placards › Vessel Number (state)
Issued 7 June 2005
Resolved
Mark hull with vessel name, hailing port and state registration number (46 CFR 185.602).
Action required: 705 - Other - as specified
Due 13 June 2005
Resolved 10 June 2005
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 7 June 2005
Resolved
Provide evidence of valid state registration.
Action required: 705 - Other - as specified
Due 13 June 2005
Resolved 10 June 2005
Electrical › Electric Supply System (service) › Cable
Issued 7 June 2005
Resolved
Remove all dead-ended conductors/cables from various locations on vessel. (46 CFR 183.340).
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2005
Resolved 10 June 2005
Electrical › Electrical Distribution System (service) › Conductor
Issued 7 June 2005
Resolved
Properly support electrical conductors for all bilge pumps with metal supports every 24" and route conductors as high above bilge as practical and protect from mechanical damage. (46 CFR 183.340).
Action required: 705 - Other - as specified
Due 13 June 2005
Resolved 10 June 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 June 2005
Resolved
Install suitable junction boxes for all bilge pump butt connectors. (46 CFR 183.340)
Action required: 705 - Other - as specified
Due 13 June 2005
Resolved 10 June 2005
Construction/Loadline › Hull
Issued 16 April 2004
Resolved
Fractured welds between the deck stiffeners and the transvers cross members on the underside of the deck between hulls. Fractures noted on cross members 2, 3, 4, 8, 9, 11 and 13 starting FWD. LEGACY COMPONENT DESC: Weld
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2004
Resolution: Fratcures welded.
Construction/Loadline › Hull
Issued 16 April 2004
Resolved
Bracket between the aft portion of the deck and the port hull found to be fractured. Repair or replace. LEGACY COMPONENT DESC: Bracket
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2004
Resolution: Bracket welded.
Construction/Loadline › Hull
Issued 16 April 2004
Resolved
Found doubler plates installed on port and starboard hull. Provide repair proposal for evaluation addressing repairs to port and starboard hull prior to credit hull exam or crop and renew hull plating IAW accepted standards. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2004
Resolution: Letter from CID allows the vessel to have doublers until next DDX 6 SEP 04.
Construction/Loadline › Hull
Issued 16 April 2004
Resolved
Found pitting on port hull near engine mount. Repair pitting on port hull aft near engine mount. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2004
Resolution: Pitting welded.
Construction/Loadline › Hull
Issued 6 May 2002
Resolved
Repair electrolysis eaten weld in way of port bow 6' aft of stem. LEGACY COMPONENT DESC: Weld
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 14 May 2002
Construction/Loadline › Hull
Issued 6 May 2002
Resolved
Repair weld stbd side 4' aft of stem fracture. LEGACY COMPONENT DESC: Weld
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 14 May 2002
Engineering
Issued 12 July 1995
Resolved
MAKE REPAIRS TO PORT AND STBD ENGINES AND PROVE PROPER OPERATION PRIOR TO LOADING PASSENGERS.
Condition: Unknown
Due 12 July 1995
Resolved 12 July 1995