Records from 1985 to 2007. Most recent: inspection, 3 December 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 62
3 December 2007
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3108537
6 June 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2671827
29 November 2004
Administrative Inspection
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2249788
25 February 2004
Damage Survey
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2013507
11 February 2004
Administrative Inspection
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2016586
14 November 2002
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1705583
20 November 2001
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1076747
16 November 2001
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1426693
17 July 2001
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1068592
2 October 2000
Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1054647
14 April 2000
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1048482
10 November 1999
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1404870
20 January 1999
Hull Examination · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1464818
19 November 1998
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1421592
16 July 1998
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1464798
2 July 1998
Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1127235
29 December 1997
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1118531
24 November 1997
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1430480
28 March 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1097349
22 January 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1099862
20 December 1996
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1093606
20 December 1996
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1094351
22 November 1996
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1179970
5 December 1995
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1079963
27 November 1995
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1079344
1 October 1995
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 10056
3 March 1995
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1165823
31 January 1995
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1403896
30 November 1994
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 834089
4 January 1994
Deficiency Check · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 850604
12 January 1993
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 827577
26 October 1992
Examination of Repairs
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 956303
13 January 1992
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1269240
28 February 1991
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1304713
20 February 1991
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 912678
14 February 1991
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1219815
22 January 1991
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1220059
16 January 1991
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 902643
30 April 1990
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1235728
18 April 1990
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 930251
19 March 1990
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 926067
11 March 1990
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1218189
7 February 1990
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 908669
16 January 1990
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1242181
5 April 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 890073
21 March 1989
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 896184
7 February 1989
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 896399
4 April 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1301767
10 February 1988
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1021100
9 July 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1028901
1 April 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1329234
4 March 1987
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1314453
3 November 1986
Damage Survey · Examination of Repairs
Physical examination · MSO CINCINNATI · Activity 1320238
29 July 1986
Type not recorded
No type recorded · MSO CINCINNATI · Activity 996571
11 April 1986
Type not recorded
No type recorded · MSO CINCINNATI · Activity 999597
9 April 1986
Deficiency Check
Physical examination · MSO CINCINNATI · Activity 998458
7 March 1986
COI Inspection
Physical examination · MSO CINCINNATI · Activity 992772
6 February 1986
Credit Drydock
Administrative · MSO CINCINNATI · Activity 1296731
4 June 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 1288346
29 April 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 980349
10 April 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 981242
2 April 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 980268
Construction/Loadline › Hull › Side Shell
Issued 2 March 2004
Resolved
Prior to towing the vessel without passengers to Greenville, MS for dry-docking, provide on board two salvage pumps and sufficient fuel for the pumps and make frequent rounds of all spaces to check for flooding. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Due 3 March 2004
Resolved 2 March 2004
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 2 March 2004
Resolved
Prior to operating with pasengers, provide a determination from a naval architect with the max wind speed that the vsl can safely maneuver in based on the known sail area and the horsepower available to the dedicated towing vessel. River current speeds should also be taken into account.
Due 3 March 2004
Resolved 2 March 2004
Fire Fighting › Fire Hoses
Issued 14 November 2002
Resolved
Provide six fire hoses that comply with Underwriters Labratory 19 in accordance with 46 CFR 118.320. LEGACY COMPONENT DESC: Material
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2002
Fire Fighting › Nozzles
Issued 14 November 2002
Resolved
Provide nozzles, that meet the requirements of ASTM F 1546 in accordance with 46 CFR 162.027-2. LEGACY COMPONENT DESC: Type
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2002
Resolved 20 November 2002
Fire Fighting › Miscellaneous Items
Issued 14 November 2002
Resolved
Provide one compatable spanner wrench for each fire hose station.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2002
Fire Fighting › Fire Pumps
Issued 14 November 2002
Resolved
Prove proper operation of second fire pump as required by Certificate of Inspection LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 14 November 2002
Resolved
Provide two portable fire extingishers to comply with the total required on Certificate of Inspection. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 November 2002
Resolved
Provide onboard the required amount of adult size personal floatation devices in accordance with 46 CFR 117.71. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 November 2002
Resolved
Segregate child size PFDs from adult size PFDs in accordance with 46 CFR 121.710 LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 November 2002
Resolved
Provide onboard a first aid kit in accordance with 46 CFR 160.041 and 46 CFR 121.710 LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2002
Operations/Management › Drills/Instruction › Fire
Issued 14 November 2002
Resolved
Commence logging of training and drills in accordance with 46 CFR 122.420
Action required: 705 - Other - as specified
Resolved 27 November 2007
Electrical › Lighting (emergency)
Issued 14 November 2002
Resolved
Prove proper operation of emergency lighting on main deck, port side, aft in accordance with 46 CFR 120.432. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2002
Construction/Loadline › Markings › Load Line Mark
Issued 14 November 2002
Resolved
Paint draft marks in a contrasting color to hull in accordance with 46 CFR 122.602 LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Due 14 December 2002
Resolved 27 November 2007
Construction/Loadline › Hull
Issued 14 November 2002
Resolved
Make permanent repairs in way of broken and laid over vent pipe on port side. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 14 December 2002
Resolved 19 November 2002
Electrical › Electrical Distribution System (service) › Cable
Issued 14 November 2002
Resolved
Properly support and install all cable and wiring in accordance with 46 CFR 120.340. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 14 December 2002
Resolved 27 November 2007
Electrical › Lighting (service)
Issued 14 November 2002
Resolved
Properly secure light fixture in bow bilge compartment iaw 46 CFR 120.410 LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 14 December 2002
Resolved 19 November 2002
Construction/Loadline › Structures › Deck Plating
Issued 14 November 2002
Resolved
Crop and renew as original to good metal main deck portside in way of switch room.
Condition: Improper/Lack of Maintenance
Due 10 February 2003
Resolved 27 November 2007
Electrical
Issued 16 November 2001
Resolved
Prior to operating with passengers, prove the proper operation of the vessel's emergency lighting.
Condition: Unknown
Due 16 November 2001
Resolved 16 November 2001
Electrical
Issued 16 November 2001
Resolved
Prior to operating with passengers, prove the proper operation of the vessel's generator under load.
Condition: Unknown
Due 16 November 2001
Resolved 16 November 2001
Construction/Loadline
Issued 16 November 2001
Resolved
Prior to 16 December 2001, provide and install a high level bilge alarm in compartment number 5 in accordance with 46 Code of Federal Regulations Part119.530(a)(3).
Condition: Unknown
Due 16 December 2001
Resolved 14 November 2002
Resolution: CONDUCTED SATISFACTORY OPERATIONAL TEST
Construction/Loadline
Issued 16 November 2001
Resolved
Prior to operating with passengers, reconnect the reach rod on the bilge suction valve in the bow void.
Condition: Unknown
Due 16 November 2001
Resolved 16 November 2001
Lifesaving
Issued 16 November 2001
Resolved
Prior to operating with passengers, either properly secure or remove the helium compressed gas cylinder.
Condition: Unknown
Due 16 November 2001
Resolved 16 November 2001
Lifesaving
Issued 10 November 1999
Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS PRIOR TO CARRIAGE OF PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 November 1999
Resolved 16 November 1999
Construction/Loadline
Issued 10 November 1999
Resolved
PROVIDE AUDIO FOR #5 COMPT BILGE HIGH LEVEL ALARM.
Condition: Unknown
Due 30 November 1999
Resolved 16 November 1999
Construction/Loadline
Issued 16 July 1998
Resolved
MAKE PERMANENT REPAIR TO BILGE KNUCKLE PLATE IN WAY OF #5 PORT VOID.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Construction/Loadline
Issued 2 July 1998
Resolved
MAKE PERMANENT REPAIR TO SUPERSTRUCTURE, MAINDECK, PORT SIDE FORWARD.
Condition: Unknown
Due 16 July 1998
Resolved 3 September 1998
Electrical
Issued 24 November 1997
Resolved
Install proper metal cable ties on wiring in voids No. 6, 4 and 1.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Construction/Loadline
Issued 24 November 1997
Resolved
Seal drilled holes in main deck exposed to weather and leading to No. 2 void.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Electrical
Issued 24 November 1997
Resolved
Provide lens cover for emergency light located on second deck starboard by stairway.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Lifesaving
Issued 24 November 1997
Resolved
Stencil ring buoy on bow with vessel name.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Construction/Loadline
Issued 24 November 1997
Resolved
Dewater bilges of No. 6 void after repairing gray water drain from galley sinks.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Lifesaving
Issued 24 November 1997
Resolved
Provide proper stenciling for life jacket lockers on upper weather deck near stairways.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Electrical
Issued 24 November 1997
Resolved
Demonstrate proper operation of the emergency generator located on the upper deck.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Accommodation/Occupational Safety
Issued 24 November 1997
Resolved
Install proper pipe supports to pipe runs in voids No. 6 and 1.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Construction/Loadline
Issued 22 November 1996
Resolved
MAKE WATERTIGHT THE THE PORTSIDE FORWARD VENT TO THE NUMBER 5 COMPARTMENT.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Construction/Loadline
Issued 22 November 1996
Resolved
MAKE WATERTIGHT THE BULKHEAD PENETRATION - APPROXIMATELY CENTERLINE - BETWEEN COMPARTMENTS #5 AND #6 - LOCATED APPROXIMATELY 3 FT ABOVE THE DECK.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Construction/Loadline
Issued 22 November 1996
Resolved
CROP OUT TO GOOD STEEL AND INSERT MAIN DECK AFT AT TRANSOM APPROXIMATELY 7 FT INBOARD FROM PORT SIDE - INSERT SHOULD BE AT LEAST 18"X18" - INSPECTOR MUST BE CALLED TO WITNESS/INSPECT FIT UP OF REPLACEMENT STEEL.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Electrical
Issued 22 November 1996
Resolved
REPLACE THE THREE BROKEN 4-GANG OUTLET COVERS LOCATED AT STARBOARD MAIN DECK BAR, AFT.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Electrical
Issued 22 November 1996
Resolved
REPLACE 2 GANG OUTLET COVERS UPPER DECK BAR, PORTSIDE.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Navigation
Issued 27 November 1995
Resolved
PROVIDE VERTICAL FILAMENT BULBS AND/OR NAVIGATION LIGHT FIXTURES THAT MEET THE HORIZONTAL AND VERTICAL SECTOR REQUIREMENTS OF ANNEX I TO THE 72 COLREGS/INLAND NAV RULES. THIS MUST BE SATISFACTORILY COMPLETED PRIOR TO OPERATING AT NIGHT OR DURING PERIODS OF RESTRICTED VISIBILITY.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Lifesaving
Issued 27 November 1995
Resolved
UNABLE TO CONDUCT UNDERWAY MAN OVERBOARD DRILLS DUE TO LACK OF REQUIRED CREW. DRILLS TO BE CONDUCTED NLT 12/15/95.
Condition: Unknown
Due 12 December 1995
Resolved 11 December 1995
Electrical
Issued 27 November 1995
Resolved
TWO BLANK INSERTS IN CIRCUIT BREAKER BOX MISSING. CORRECTED DURING INSPECTION.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Electrical
Issued 27 November 1995
Resolved
ELECTRICAL OUTLET BOX FACE PLATE NOT PROPERLY ATTACHED. CORRECTED DURING INSPECTION.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Accommodation/Occupational Safety
Issued 27 November 1995
Resolved
GALLEY REEFER DOOR SECURED BY PADLOCK AND CHAIN PREVENTING EMERGENCY EXIT OF TRAPPED PERSONNEL. CORRECTED DURING INSPECTION.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Fire Fighting
Issued 30 November 1994
Resolved
PROVIDE SERVICING CERTIFICATE FOR ALL PORTABLE FIRE EXTINGUISHERS AND THE FIXED CO2 SYSTEM ABOARD THE M/V [name withheld].
Condition: Unknown
Due 30 November 1994
Resolved 30 November 1994
Electrical
Issued 4 January 1994
Resolved
RENEW INOPERABLE BULBS IN BOTH FORWARD EMERGENCY LIGHT FIXTURES LOCATED ON SECOND DECK, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 4 January 1994
Resolved 4 January 1994
Electrical
Issued 4 January 1994
Resolved
ON PUSHBOAT [name withheld], INSTALL RUBBER DECK MATTING IN FRONT OF MAIN ELECTRICAL DISTRIBUTION PANELS NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 4 January 1994
Resolved 4 January 1994
Documentation
Issued 4 January 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 January 1994
Resolved 4 January 1994
Documentation
Issued 4 January 1994
Resolved
PROVIDE MASTER'S STATEMENT OF DESIGNATED SENIOR DECKHAND, PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 4 January 1994
Resolved 4 January 1994
Documentation
Issued 4 January 1994
Resolved
POST BOTH PAGES OF VESSEL'S CERTIFICATE OF INSPECTION PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 4 January 1994
Resolved 4 January 1994
Fire Fighting
Issued 4 January 1994
Resolved
ON PUSHBOAT [name withheld], INSTALL NO. 7 PORTABLE FIRE EXTINGUISHER ON PROPER BRACKET, LOCATED IN GALLEY, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 4 January 1994
Resolved 4 January 1994
Fire Fighting
Issued 4 January 1994
Resolved
ON PUSHBOAT [name withheld], PROVIDE PROOF OF ANNUAL SERVICE TO GALLEY FIXED FIRE EXTINGUISHER, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 4 January 1994
Resolved 4 January 1994
Lifesaving
Issued 4 January 1994
Resolved
ON PUSHBOAT, ENSURE ALL LIFE PRESERVERS ARE MARKED WITH THE VESSEL'S NAME "[name withheld]", NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 4 January 1994
Resolved 4 January 1994
Electrical
Issued 12 January 1993
Resolved
REPLACE EXTINGUISHED LIGHT BULB IN EMERGENCY LIGHT FIXTURE LOCATED ON 2ND DECK, STARBOARD SIDE, PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 12 February 1993
Resolved 2 February 1993
Electrical
Issued 12 January 1993
Resolved
MAKE OPERABLE OR REMOVE BROKEN UNUSED LIGHT FIXTURES WITH ASSOCIATED WIRINGLOCATED IN THE NUMBERS 3 AND 5 VOID COMPARTMENTS, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 12 February 1993
Resolved 2 February 1993
Electrical
Issued 12 January 1993
Resolved
REPAIR OR RENEW INOPERABLE FREQUENCY METER AND AMMETER, AND PROPERLY SECURELOOSE FUEL LINE TO GENERATOR PRIME MOVER, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Fire Fighting
Issued 12 January 1993
Resolved
REPLACE ALL PORTABLE FIRE EXTINGUISHERS, WHICH WERE TEMPORARILY REMOVED FORHYDRO SERVICING, PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 12 February 1993
Resolved 2 February 1993
Electrical
Issued 12 January 1993
Resolved
REPLACE COVER ON TELEPHONE DISTRIBUTION PANEL IN VIP ROOM PRIOR TO CARRYINGPASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 12 February 1993
Resolved 2 February 1993
Electrical
Issued 12 January 1993
Resolved
SECURE LOOSE ELECTRICAL WIRING HANGING DOWN FROM NUMBER 3 VOID COMPARTMENT OVERHEAD NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 12 February 1993
Resolved 2 February 1993
Electrical
Issued 12 January 1993
Resolved
MAKE OPERABLE AND DEMONSTRATE SATISFACTORY OPERATION OF EMERGENCY GENERATORPRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 12 February 1993
Resolved 2 February 1993
Lifesaving
Issued 12 January 1993
Resolved
DEMONSTRATE SATISFACTORY UNDERWAY FIRE, DEWATERING, AND MAN-OVER-BOARD DRILLS WITH FULL CREW COMPLIMENT ON BOARD PRIOR TO CARRYING PASSENGERS, BUTNOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 12 February 1993
Resolved 2 February 1993
Lifesaving
Issued 12 January 1993
Resolved
MARK LIFE PRESERVER STOWAGE LOCATIONS ON UPPER DECK PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 12 February 1993
Resolved 2 February 1993
Lifesaving
Issued 13 January 1992
Resolved
DEMONSTRATE SATISFACTORY UNDERWAY FIRE AND MAN-OVER-BOARD DRILLS WITH FULL CREW COMPLIMENT ON BOARD PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 13 February 1992
Resolved 29 January 1992
Lifesaving
Issued 13 January 1992
Resolved
RENEW ROTTED RING LIFE BUOY GRAB LINES LOCATED ON UPPER DECK OF FUNLINER AND OUTSIDE PILOT HOUSE ON M/V [name withheld], NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 February 1992
Resolved 29 January 1992
Lifesaving
Issued 13 January 1992
Resolved
MARK PROPER STOWAGE LOCATION FOR LIFE PRESERVERS, STARBOARD SIDE, MAIN DECKNOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 February 1992
Resolved 29 January 1992
Lifesaving
Issued 13 January 1992
Resolved
ADD HIGHER LIFE PRESERVER LOCATION NOTICE ABOVE BOTH PFD STORAGE COMPARTMENTS LOCATED AT FORWARD END OF DANCE FLOOR, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 February 1992
Resolved 29 January 1992
Construction/Loadline
Issued 13 January 1992
Resolved
REMOVE DEBRIS AND EXTRANEOUS MATERIALS FROM NOS. 2 THROUGH 6 VOID COMPARTMENT BILGES NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 February 1992
Resolved 29 January 1992
Electrical
Issued 13 January 1992
Resolved
REMOVE OR TERMINATE IN JUNCTION BOX, UNUSED ELECTRICAL WIRE IN ELECTRICAL DISTRIBUTION PANEL ROOM OVERHEAD, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 February 1992
Resolved 29 January 1992
Electrical
Issued 13 January 1992
Resolved
REPAIR OR REPLACE INOPERABLE FREQUENCY METER AND VOLTMETER ON EMERGENCY GENERATOR NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 January 1992
Resolved 13 January 1992
Deck/Cargo
Issued 13 January 1992
Resolved
PROVIDE SHACKLE TO CONNECT ANCHOR TO ANCHOR LINE NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 February 1992
Resolved 29 January 1992
Electrical
Issued 13 January 1992
Resolved
INSTALL BELT GUARDS ON MAIN AND AUXILIARY GENERATORS LOCATED ON M/V [name withheld] NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 January 1992
Resolved 13 January 1992
Construction/Loadline
Issued 13 January 1992
Resolved
MAKE PERMANENT REPAIRS TO WASTED DECK PLATE ADJACENT TO OUTBOARD BULKHEAD IN ELECTRICAL DISTRIBUTION PANEL ROOM NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 January 1992
Resolved 13 January 1992
Electrical
Issued 13 January 1992
Resolved
REPLACE EXTINGUISHED LIGHT BULB IN EMERGENCY LIGHT FIXTURE LOCATED PORT SIDE, SECOND DECK, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 February 1992
Resolved 29 January 1992
Electrical
Issued 13 January 1992
Resolved
INSTALL INSULATION ON BOTH MAIN AND AUXILIARY GENERATOR EXHAUST PIPES, LOCATED ON M/V [name withheld], NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 January 1992
Resolved 13 January 1992
Electrical
Issued 13 January 1992
Resolved
INSTALL GROMMET TO PREVENT FUEL LINE CHAFING AT DECK PENETRATION BENEATH MAIN GENERATOR, LOCATED ON M/V [name withheld], NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 13 January 1992
Resolved 13 January 1992
Fire Fighting
Issued 16 January 1991
Resolved
MARK LOCATION OF FIRE DAMPER CONTROLS NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Electrical
Issued 16 January 1991
Resolved
REPLACE EXTINGUISHED BULB IN 2ND DECK, PORTSIDE, EMERGENCY LIGHT FIXTURE NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Electrical
Issued 16 January 1991
Resolved
MAKE WATERTIGHT ALL ELECTRIC WIRE PENETRATIONS IN VOID COMPARTMENT WATERTIGHT BULKHEADS NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Deck/Cargo
Issued 16 January 1991
Resolved
REPLACE ALL MISSING BILGE SUCTION STRAINER SCREENS NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Electrical
Issued 16 January 1991
Resolved
REPLACE MISSING AND BROKEN LIGHT FIXTURE GLOBES IN VOID COMPARTMENTS #1, #5, AND #6 NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Construction/Loadline
Issued 16 January 1991
Resolved
INSTALL GASKET FOR FOREPEAK HATCH COVER NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Construction/Loadline
Issued 16 January 1991
Resolved
CROP TO GOOD METAL (75% REQUIRED SCANTLING) ALL WASTED DECK, PORT SIDE, OVER NO. 5 COMPARTMENT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Construction/Loadline
Issued 16 January 1991
Resolved
MAKE PERMANENT REPAIRS TO PIN-HOLES IN UPPER SIDE PLATE, PORT SIDE #1 AND #2 COMPARTMENTS, AND STARBOARD SIDE #5 COMPARTMENT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Electrical
Issued 16 January 1991
Resolved
COVER BREAKER SWITCH PUNCH-OUT HOLE IN #5 COMPARTMENT ELECTRIC DISTRIBUTIONBOX NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Fire Fighting
Issued 16 January 1991
Resolved
REPLACE ALL NON-APPROVED (INTERIOR) FIRE HOSES WITH UNDERWRITERS LABORATORYLISTED NO. 19 LINED TYPE HOSES NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Construction/Loadline
Issued 11 March 1990
Resolved
PER OWNER PROPOSAL CROP AND RENEW TO PROVIDE A MIN. THICKNESS OF .258 INCH ALL BOTTOM PLATING IN WAY OF AREAS LESS THAN .190 INCH. THIS REQUIREMENT SHALL BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] PASSENGERS FOR HIRE BUT IN NO CASE LATER THAN 28 APRIL 1990.
Condition: Unknown
Due 11 March 1990
Resolved 11 March 1990
Construction/Loadline
Issued 11 March 1990
Resolved
PENDING BOTTOM PLATE RENEWAL IWO AREAS LESS THAN .206" INSTALL BILGE ALARM SYS. WITH PILOT HOUSE MONITORING DEVICE IWO VOID SPACES HAVING BOTTOM PLATETHICKNESS OF LESS THAN .206". THIS REQ. SHALL BE COMPLETED TO THE SAT. OF THE COGNIZANT [name withheld] PASSENGERS FOR HIRE BUT NLT 28 APR 90.
Condition: Unknown
Due 11 March 1990
Resolved 11 March 1990
Construction/Loadline
Issued 11 March 1990
Resolved
CROP AND RENEW TO PROVIDE A MIN. THICKNESS OF .248 INCH ALL SIDE SHELL PLATING IN WAY OF AREAS LESS THAN .186 INCH. THIS REQUIREMENT SHALL BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 11 March 1990
Resolved 11 March 1990
Construction/Loadline
Issued 11 March 1990
Resolved
CROP AND RENEW ALL WASTED AND DISTORTED FRAMES IN WAY OF NO. ONE(1) AND NO.TWO(2) COMPARTMENT. THIS REQUIREMENT SHALL BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] PASSENGERS FOR HIRE BUT IN NO CASE LATER THAN 28 APRIL 1990.
Condition: Unknown
Due 11 March 1990
Resolved 11 March 1990
Construction/Loadline
Issued 11 March 1990
Resolved
REMOVE WATER FROM NO. THREE(3) COMPARTMENT, DETERMINE SOURCE OF LEAKAGE ANDPRESENT FOR COAST GUARD INTERNAL EXAMINATION. THIS REQUIREMENT SHALL BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] PASSENGERS FOR HIRE BUT IN NO CASE LATER THAN 28 APRIL 1990.
Condition: Unknown
Due 11 March 1990
Resolved 11 March 1990
Documentation
Issued 11 March 1990
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, VESSEL SHALL COMPLY WITH CURRENT STABILITY LETTER DATED 31 JULY 1986. THIS REQUIREMENT SHALL BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] BUT IN NO CASE LATER THAN 28 APRIL 1990.
Condition: Unknown
Due 11 March 1990
Resolved 11 March 1990
Construction/Loadline
Issued 11 March 1990
Resolved
MAKE VESSEL'S SIDE SHELL AREA WATERTIGHT IN WAY OF SEVERAL LOOSE SIDE SHELLRIVETS. THIS REQUIREMENT SHALL BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] PASSENGERS FOR HIRE BUT IN NO CASE LATER THAN 28 APRIL 1990.
Condition: Unknown
Due 11 March 1990
Resolved 11 March 1990
Construction/Loadline
Issued 11 March 1990
Resolved
PRESENT VESSEL'S SEA SUCTION VALVE FOR INTERNAL EXAMINATION. THIS REQUIREMENT SHALL BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] PASSENGERS FOR HIRE BUT IN NO CASE LATER THAN 28 APRIL 1990.
Condition: Unknown
Due 11 March 1990
Resolved 11 March 1990
Construction/Loadline
Issued 11 March 1990
Resolved
CROP AND RENEW TO PROVIDE A MIN. THICKNESS OF .258 INCH ALL BOTTOM PLATING IN WAY OF AREAS LESS THAN .206 INCH. THIS REQUIREMENT SHALL BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 11 March 1990
Resolved 11 March 1990
Construction/Loadline
Issued 16 January 1990
Resolved
MAKE PERMANENT REPAIRS TO THE TRIPPED AND WASTED TRANSVERSE FRAMES AT THE MIDSHIPS SECTION OF THE #2 COMPARTMENT (UNDER THE OLD BOILER SPACE, NOW THEDANCE FLOOR) TO THE SATISFACTION OF THE COGNIZANT [name withheld] PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Lifesaving
Issued 16 January 1990
Resolved
PROVIDE 28 APPROVED ADULT LIFE PRESERVERS PRIOR TO THE COMPLIANCE DATE. TOTAL PERSONS ABOARD IS RESTRICTED TO 589 UNTIL LIFE PRESERVERS HAVE BEEN PLACED ON BOARD AND HAVE BEEN INSPECTED BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Lifesaving
Issued 7 February 1989
Resolved
REPAIR BROKEN RIB IN RESCUE BOAT AT TRANSOM, PORTSIDE.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Fire Fighting
Issued 7 February 1989
Resolved
PROVIDE CLEARLY MARKED ACCESS TO FIRE DAMPER OPERATIONAL HANDLE AND PROVE OPERATION.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Accommodation/Occupational Safety
Issued 7 February 1989
Resolved
INSTALL PERAMANENT WIRING CONNECTIONS WITH A SWITCH FOR THE 110V SANITARY PUMP IN NO. 6 HOLD.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Lifesaving
Issued 7 February 1989
Resolved
PROVIDE 11 ADULT PFD'S OF APPROVED TYPE.
Condition: Unknown
Due 7 February 1989
Resolved 7 February 1989
Lifesaving
Issued 10 February 1988
Resolved
REPLACE THE RESCUE BOAT WITH ONE MEETING THE REQUIREMENTS OF 46 CFR 160.056
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Electrical
Issued 10 February 1988
Resolved
COMPLETE THE INSTALLATION OF THE WIRING SYSTEM FOR THE SECOND BILGE PUMP'S SEPERATE POWER SUPPLY.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Electrical
Issued 4 March 1987
Resolved
INSTALL IN THE ELECTRICAL SWITCHING AREA A MEANS OF INDICATING WHETHER SHORE POWER, EMG GEN POWER OR NORMAL SYSTEMS ARE BEING FED TO THE MAIN BREAKERS AND WHICH SYSTEM IS CURRENTLY "ON LINE".
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Electrical
Issued 4 March 1987
Resolved
REPLACE OR REPAIR TO MAKE OPERABLE TO VOLTMETER ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Construction/Loadline
Issued 29 July 1986
Resolved
MAKE THE WELL DECK (DANCE FLOOR) AREA WATERTIGHT THROUGHOUT ITS PERIMETER AND DECK AREA.
Condition: Unknown
Due 29 July 1986
Resolved 29 July 1986
Electrical
Issued 7 March 1986
Resolved
PERMANENTLY WIRE THE ELECTRICAL CIRCUIT TO THE EMERGENCY GENERATOR BATTERY CHARGER AND PERMANENTLY MOUNT THE BATTERY CHARGER.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Construction/Loadline
Issued 7 March 1986
Resolved
COMPLETE THE WELDING OF THE NEWLY-INSTALLED THROUGH HULL FITTINGS.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Electrical
Issued 7 March 1986
Resolved
PROPERLY INSTALL THE ELECTRICAL LEAD FOR THE STAGE BOOM.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Electrical
Issued 7 March 1986
Resolved
PROPERLY REWIRE THE ELECTRICAL CIRCUIT FOR THE BATTERY CHARGER FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Lifesaving
Issued 7 March 1986
Resolved
THE VESSEL IS LIMITED TO THE CARRIAGE OF 450 PASSENGERS UNTIL SUCH TIME THAT THE NEEDED 115 ADULT AND INSPECTED AND STAMPED.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Documentation
Issued 6 February 1986
Resolved
PERFORM IN THE PRESENCE OF A COAST GUARD INSPECTOR STABILITY TESTS AS NECESSARY TO PROVE THE VESSEL'S ABILITY TO REMAIN STABLE WITH IT'S RATED PASSENGER LOAD.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Construction/Loadline
Issued 6 February 1986
Resolved
CLEAN AND MAINTAIN CLEAN THE AREA OF THE BOW COMPARTMENT TO FACILITATE INSPECTION OF THE STRENGTH MEMBERS.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Construction/Loadline
Issued 2 April 1985
Resolved
PLUG OR CAP BOTH PIPES THAT PENETRATE THE COLLISION BULKHEAD ON THE PORT SIDE. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING YOUR VESSEL IN SER- VICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Construction/Loadline
Issued 2 April 1985
Resolved
REMOVE THE PIPES PENETRATING THE COLLISION BULKHEAD ON THE PORT SIDE AND PROPERLY INSERT THE AREA IN WAY OF THE PIPES FOLLOWING THEIR REMOVAL.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Construction/Loadline
Issued 2 April 1985
Resolved
CROP AND RENEW SIDE PLATE IN WAY OF THE BOLTED IN THROUGH HULL (BLANK FLANGE) FITTING IN THE BOW ON THE STARBOARD SIDE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Construction/Loadline
Issued 2 April 1985
Resolved
CROP OUT THE TEMPORARY REPAIR IN THE SIDE PLATE IN THE VESSEL'S STERN WHERETHE PIPE WAS REMOVED ON THE STARBOARD SIDE, AND IN THE COMPARTMENT IMMED- IATELY FORWARD OF THE STERN, THE 1" PIPE THAT HAS BEEN TEMPORARILY REPAIREDIS TO REMOVED WITH PROPER PERMANENT REPAIRS TO BE MADE TO SIDE PLATE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Construction/Loadline
Issued 2 April 1985
Resolved
OPEN BOTH AMIDSHIP WING TANKS FOR INSPECTION.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Accommodation/Occupational Safety
Issued 2 April 1985
Resolved
PROVIDE PROPER RELIEF VALVES FOR THE PRESSURIZED WATER TANK AFT.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Construction/Loadline
Issued 2 April 1985
Resolved
PLACE A PLUG IN THE OPEN FITTING ON THE SEA CHEST.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Electrical
Issued 2 April 1985
Resolved
MAKE REPAIRS AS NECESSARY TO THE ELECTRICAL SYSTEM TO PREVENT VOLTAGE FLUC-TUATION ON THE VESSEL.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Fire Fighting
Issued 2 April 1985
Resolved
PROVIDE THE THREE MISSING A-II FIRE EXTINGUISHERS. KEEP TWO PORTABLE FIRE PUMPS ONBOARD UNTIL FIRE EXTINGUISHERS CAN BE PLACED ONBOARD.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Construction/Loadline
Issued 2 April 1985
Resolved
KEEP THE PORTABLE FIRE/BILGE PUMPS ONBOARD THE VESSEL UNTIL SUCH TIME AS THE FIRE AND BILGE SYSTEM CAN BE DESIGNED AND PLACED ON THE VESSEL.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Unknown
Issued 2 April 1985
Resolved
MAINTAIN THE TEMPORARY REPAIRS ON THE HULL PENETRATIONS IN THE STERN COMPARTMENT AND THE SPACE IMMEDIATELY FORWARD, INSURING THAT THESE TWO SPACES AS WELL AS THE SPACE FORWARD OF THE COLLISION BULKHEAD ARE CHECKED FOR FLOODING EACH TIME THE VESSEL IS TO GET UNDERWAY.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Accommodation/Occupational Safety
Issued 2 April 1985
Resolved
EACH TIME THE VESSEL IS TO GET UNDERWAY, AND AT ANYTIME PERSONS ARE ABOARD THE VESSEL AND USEING THE RESTROOM FACILITIES THE MARINE SANITATION DEVICE IS TO BE KEPT IN FULL OPERATION, WITH A CHECK TO BE MADE TO ENSURE THAT THEOVERBOARD DISCHARGE VALVE IS IN THE FULLY CLOSED POSITION.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Electrical
Issued 2 April 1985
Resolved
PERMANENTLY AND PROPERLY ATTACH THE EMERGENCY GENERATOR FUEL OIL TANK TO THE UPPER DECK. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Electrical
Issued 2 April 1985
Resolved
PROVIDE A PROPER TEST OF THE NEWLY-INSTALLED FUEL OIL TANK FOR THE EMER- GENCY GENERATOR; SEE CFR 182.20-25(C).
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Electrical
Issued 2 April 1985
Resolved
PROVIDE A PROPER BATTERY BOX FOR THE EMERGENCY GENERATOR STARTING BATTERY.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Fire Fighting
Issued 2 April 1985
Resolved
PROVIDE PROPER HANGERS FOR ALL ONBOARD PORTABLE FIRE EXTINGUISHERS. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Fire Fighting
Issued 2 April 1985
Resolved
PROVIDE A HAND FIRE PUMP WITH SUCTION AND DISCHARGE HOSE. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Lifesaving
Issued 2 April 1985
Resolved
PROVIDE PROPER LIFE RINGS FOR THE VESSEL WITH LIGHT AND LINE AS REQUIRED. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Unknown
Issued 2 April 1985
Resolved
PROVIDE A PROPER EMERGENCY CHECK-OFF LIST. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Construction/Loadline
Issued 2 April 1985
Resolved
MAKE EFFECTIVE TEMPORARY REPAIRS TO THE HOLED PIPE PENETRATING THE SIDE PLATE IN THE STERN COMPARTMENT ON THE STARBOARD SIDE. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Lifesaving
Issued 2 April 1985
Resolved
PROPERLY MARK ALL LIFE JACKET STOWAGE LOCKERS. THIS ITEM IS TO BE COR- RECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Electrical
Issued 2 April 1985
Resolved
PROVIDE A PROPER FLAME SCREEN FOR THE EMERGENCY GENERATOR'S FUEL TANK. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Electrical
Issued 2 April 1985
Resolved
PROVIDE A PROPER FUSE AT THE EMERGENCY GENERATOR DISCONNECT. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Electrical
Issued 2 April 1985
Resolved
ELECTRICALLY BOND THE FUEL TANK FOR THE EMERGENCY GENERATOR TO COMMON GROUND.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Accommodation/Occupational Safety
Issued 2 April 1985
Resolved
MOVE THE LOCATION OF THE TISSUE DISPENSERS IN BOTH RESTROOMS TO PREVENT THEPINCHING OF HANDS AND FINGERS. THIS ITEM IS TO BE CORRECTED PRIOR TO PLAC-ING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Electrical
Issued 2 April 1985
Resolved
MAKE OPERABLE THE EMERGENCY LIGHT AT THE PORT STAIRWAY. THIS ITEM IS TO BECORRECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Accommodation/Occupational Safety
Issued 2 April 1985
Resolved
PROVE THE PROPER OPERATION OF THE MARINE SANITATION SYSTEM. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Accommodation/Occupational Safety
Issued 2 April 1985
Resolved
PERMANENTLY AND PROPERLY MOUNT BOTH WATER PRESSURE TANKS AND THE WATER PUMP. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985
Electrical
Issued 2 April 1985
Resolved
PROPERLY ATTACH AND SUPPORT ALL ELECTRICAL WIRES IN THE FORWARD COMPART- MENT. THIS ITM IS TO BE CORRECTED PRIOR TO PLACING YOUR VESSEL IN SERVICE.
Condition: Unknown
Due 2 April 1985
Resolved 2 April 1985