Records from 2016 to 2025. Most recent: inspection, 12 November 2025.
Inspection history · 22
12 November 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8267391
20 March 2025
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8096758
30 October 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8031983
26 September 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8009962
1 November 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7819242
29 June 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7727092
10 March 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7648807
9 November 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7592216
29 October 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7345199
5 April 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7169364
5 April 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7170867
28 October 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7089166
2 December 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6866041
30 October 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6853943
16 October 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6854012
2 October 2019
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6827437
4 September 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6803475
31 October 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6578180
28 May 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6426887
26 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6399909
25 October 2017
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6294312
9 November 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6039435
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 26 September 2024
Resolved
A MSD device must be designed to prevent the over-board discharge to treated or untreated sewage of any waste derived from sewage. Aft Type III MSD tank was found to be dripping sewage into the bilge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 20 March 2025
Resolution: Recieved photo evidence of completed repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 November 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. The watertight penetration between the #4 compartment and the steering gear compartment, on the port side aft, was compromised due to a deteriorated penetration for electrical wiring.
46 CFR 179.320(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 March 2023
Resolution: Vessel owner provided photographic evidence of the fixed bulkhead penetration.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 November 2022
Resolved
At each inspection for certification and at every other vessel inspection all hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The packing for the steering gear was actively leaking water into the compartment while underway.
46 CFR 176.830
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 March 2023
Resolution: The vessel owner replaced the packing on the steering gear.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 November 2022
Resolved
A hatch exposed to the weather must be watertight. The gasket for the watertight hatch on compartment #4 was deteriorated and needs to be replaced.
46 CFR 179.360(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 March 2023
Resolution: Vessel owner provided photographic evidence of a new gasket on the #4 compartment.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 November 2022
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. The rotating belt on the forward part of the engine did not have a guard.
46 CFR 177.960
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 March 2023
Resolution: Vessel owner provided photographic evidence of a guard on the forward part of the engine.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 November 2022
Resolved
If a garden hose is used it shall be of a good commercial grade constructed of an inner rubber tube, plies of braided cotton reinforcement and an outer rubber cover, or of other equivalent material, and shall be fitted with a commercial grade garden hose nozzle made of good grade bronze or equivalent metal. The vessel had a garden hose with a plastic nozzle on board.
46 CFR 181.15-10(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 March 2023
Resolution: Vessel owner provided photographic evidence of a new fire house and brass nozzle.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 October 2021
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Vessel is missing fuel shutoff at engine.
46 CFR 182.20-40(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2021
Resolved 3 October 2024
Resolution: Observed proper operation of fuel shut-off valves
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 October 2021
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Vessel remote fuel shutoff valve is held in place by zip ties and wrapped around valve body so pull cable is non operable. Install permanent means of remote pull cable operation.
46 CFR 182.455(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2021
Resolved 9 November 2022
Resolution: Pull cables were installed on the remote fuel shutoffs.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 29 October 2021
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150 degrees fahrenheit, must be suitably insulated where necessary to prevent injuries. Top 18" of dry exhaust lagging was missing.
46 CFR 177.970
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2021
Resolved 9 November 2022
Resolution: Lagging on the dry exhaust was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2021
Resolved
The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Vessel had multiple wire runs supported by plastic zip ties in entine room.
46 CFR 183.340(a)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2021
Resolved 9 November 2022
Resolution: Electrical runs in the engine room were supported by metal clips.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 October 2021
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Bypass switch and local engine solenoid on fireboy could not be reset once simulated actuation took place.
46 CFR 181.420(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2021
Resolved 31 January 2022
Resolution: see special notes
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 April 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion and machinery failure. Excessive oil observed in the bilge beneath the engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2021
Resolution: Photos of clean space below engine submitted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 October 2019
Resolved
Each fixed power bilge pump must be self-priming. It may be driven off the main engine or other source of power.
Deficiency: The bilge auto-switch for the forward compartment (#2) was inoperable during inspection.
Action required: 10 - Deficiency Rectified
Due 2 October 2019
Resolved 2 October 2019
Resolution: Corrected on the spot. Marine Inspector witnessed the proper operation of the forward compartment bilge auto-switch.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 October 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to date chart.
Deficiency: Vessel did not have an up-dated chart publication for the area of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 16 October 2019
Resolution: Vessel Owner provided proof of an up-to-date (i.e. 2019) chart publication for the area of operation.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 2 October 2019
Resolved
Vertical exhaust pipes must be suitably insulated or shielded from combustible material.
Deficiency: The heat shield for the engine exhaust pipe was not properly insulated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 16 October 2019
Resolution: Vessel Owner provided proof of satisfactory repairs to the heat shielding insulation for the engine's exhaust pipe.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical hazards, including fire caused by or originating in electrical equipment and electrical shock.
Deficiency: Excessive wiring were evident at the vsl’s switchboard located at the forward bulkhead of the engine room. Also, exposed wiring were found on the the battery terminals connected to the Main Diesel Engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 16 October 2019
Resolution: Vessel Owner provided proof of corrective actions to remove the safety issues associated with the excessive wiring; and removed the exposed wiring that was found on the battery terminals connected to the Main Diesel Engine.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 31 October 2018
Resolved
Each window and its means of attachment to the deckhouse must be capable of withstanding the maximum load from a wave and wind conditions expected due to its location on the vessel and the authorized toute of the vessel. The Portside front window in the operating station is broken/cracked and needs to be replaced. 46 CFR 177.1020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 13 November 2018
Resolution: Vessel Owner had previously provide proof of newly installed Portside window IWO the operating station, ALL SAT.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 October 2017
Resolved
Provide proof of valid First Aid Kit (discovered several expired items).
Due 31 October 2017
Resolved 8 November 2017
Resolution: Replaced expired first aid kit contents.
Documentation › Logs/Records › Logbook (official)
Issued 25 October 2017
Resolved
Provide proof of crew-related maintenance for the life-saving and fire-fighting equipment. Maintenance must be tracked and logged.
Due 31 October 2017
Resolved 8 November 2017
Resolution: Log book was purchased to begin recording crew training/maintenance.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 25 October 2017
Resolved
Provide proof of ship-specific emergency instructions.
Due 31 October 2017
Resolved 8 November 2017
Resolution: Emergency instructions were ship specific.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2017
Resolved
Repair/Remove “dead-end” wiring located in the engineroom compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2017
Resolved 25 October 2017
Resolution: “Dead-end” wiring located in the engineroom compartment was properly capped and secured to prevent hazard to personnel and equipment.
Electrical › Electrical Distribution System (emergency) › Outlet Box
Issued 25 October 2017
Resolved
Repair poorly mounted outlet bracket in the engine room compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2017
Resolved 25 October 2017
Resolution: The outlet bracket in the engine room compartment was properly remounted and secured to the bulkhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2017
Resolved
Repair or replace frayed electrical wiring in way of the main engine/s alternator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2017
Resolved 25 October 2017
Resolution: Vessel owner replaced the frayed electrical wiring in way of the main engine/s alternator.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 25 October 2017
Resolved
Provide proof of proper operation of the installed Fireboy System. (Note: The "auto" engine shutdown is currently INOP.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2017
Resolved 8 November 2017
Resolution: Demonstrated proper operation of installed Fireboy.