BEAVER

BEAVER is a 1952 unclassified. The Coast Guard has recorded 38 inspections since 1987, most recently in June 2014, along with 66 deficiencies.

Records from 1987 to 2014. Most recent: inspection, 2 June 2014.

Built
1952
Last inspected
2 June 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCJ7727
Flag
UNITED STATES
—
Maury page id
psix-42782

Inspections, by type

…with no type recorded5
Years with a record 25 calendar years (1987–2014)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it67 - Simplified, Net Ton
84 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 38

2 June 2014 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4877109
27 June 2012 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4357549
15 August 2011 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4117389
13 July 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4089442
17 July 2009 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3540227
13 September 2007 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3056777
3 May 2007 Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2974800
21 September 2006 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2800927
22 August 2005 Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2471436
22 September 2004 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2202317
18 September 2003 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1910806
3 October 2002 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1683987
16 September 2002 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1683958
16 August 2001 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1435268
20 February 2001 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1058494
3 October 2000 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1443082
12 October 1999 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1442894
19 August 1998 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1461068
16 September 1997 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1392772
12 August 1997 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 782857
18 July 1997 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 780584
12 June 1997 Administrative
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1113593
3 September 1996 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 938556
5 October 1995 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1190409
7 September 1994 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1174591
7 September 1993 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1135590
30 June 1993 Administrative
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1156011
13 October 1992 Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1258673
21 September 1992 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 34399
4 September 1992 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 934069
13 June 1992 Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 950456
30 August 1991 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 933215
6 September 1990 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1235104
4 May 1989 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1205084
12 October 1988 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1196401
30 April 1988 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1346606
25 April 1988 COI Inspection · Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 892182
31 August 1987 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1020604

Deficiency record · 66

Construction/Loadline › Hull › Hull Plating
Issued 2 June 2014 Resolved
Detemine extent of wastage in hull plating and internal strucutes in way of stern compartment and complete permanent repairs to same, prior to commercial operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 29 July 2014
Resolution: Vessel COI surrendered and vessel deactivated.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 27 June 2012 Resolved
Drive belts for jacket water cooling pump and alternator were loose to point of failure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2012
Resolved 27 June 2012
Resolution: corrected during inspection
Engineering › Diesel Engine (auxiliary) › Block
Issued 27 June 2012 Resolved
Drive belt for alternaotr and cooling pump on SS generator excessively loose to point of failure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2012
Resolved 27 June 2012
Resolution: corrected during inspection
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 June 2012 Resolved
Engine starting batter terminal not of permanent type and are excessively loose, to point of failure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2012
Resolved 27 June 2012
Resolution: corrected during inspection
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 June 2012 Resolved
Life preserver stowage had been changed, but labeling was not updated, indicated PFD's in space no longer containing PFD's. Correct improper labels on life preserver stowage areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 17 August 2012
Documentation › Certificates/Documents › Stability Letter
Issued 27 June 2012 Resolved
Stability letter not posted in wheelhouse.
Condition: Improper/Lack of Maintenance
Due 27 June 2012
Resolved 27 June 2012
Resolution: corrected during inspection
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 June 2012 Resolved
COI not posted
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2012
Resolved 27 June 2012
Resolution: corrected during inspection
Documentation › Certificates/Documents › FCC SSL
Issued 27 June 2012 Resolved
FCC Station License not posted.
Condition: Improper/Lack of Maintenance
Due 27 June 2012
Resolved 27 June 2012
Resolution: Corrected during inspection
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 27 June 2012 Resolved
Provided servicing report showing all portable fire extinguishers have been serviced annually.
Condition: Improper/Lack of Maintenance
Due 27 July 2012
Resolved 17 August 2012
Resolution: Servicing tags sighted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 June 2012 Resolved
Provided correct mountings for portable dry chemical fire extinguisher in wheelhouse.
Condition: Improper Installation
Due 27 June 2012
Resolved 27 June 2012
Resolution: Corrected during inspection.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 16 August 2011 Resolved
Minor fracture in wet exhaust pipe IWO aft bulkhead to be repaired. No carrying of passengers or cargo until repaired.
Action required: 705 - Other - as specified
Due 15 September 2011
Resolved 29 August 2011
Resolution: Fracture in wet exhaust pipe welded/repaired. Vessel authorized to carry passengers.
Documentation › Certificates/Documents › FCC SSL
Issued 13 July 2011 Resolved
Provide Great Lakes Agreement as required by 47 CFR 80.950 (c).
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 15 August 2011
Resolution: Great Lakes Agreement verified on vessel.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 13 July 2011 Resolved
Provide mounting bracket for water light that is attached to ring buoy as required by 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 15 August 2011
Resolution: Mounting bracket for water light installed on vessel.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 July 2011 Resolved
Service all portable fire extinguishers as required by 46 CFR 176.810.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 15 August 2011
Resolution: Fire extinguishers serviced August 2011.
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 July 2009 Resolved
Minor fracture in wet exhaust pipe at the penetration IWO aft bulkhead to be repaired during 09-10 winter layup. Space is provided high water alarm and rounds are conducted during vessel operation.
Action required: 705 - Other - as specified
Due 15 September 2011
Resolved 15 August 2011
Resolution: Extending due date to September 15th, 2011. See new deficiency.
Electrical › Electric Supply System (service) › Cable
Issued 13 September 2007 Resolved
Install metal supports for overhead cables in engine room I.A.W. 46 CFR 183.340
Action required: 705 - Other - as specified
Due 13 October 2007
Resolved 17 July 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 September 2007 Resolved
Restore watertight integrity to watertight bulkhead between rudder and engine room compartments, including gasket materials for both watertight doors leading into the engine room I.A.W. 46 CFR 179.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2008
Resolved 17 July 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 September 2007 Resolved
Restore watertight integrity of the weatherdeck above the rudder compartment I.A.W. 46 CFR 179.
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 13 July 2011
Resolution: Deficiency completed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 September 2007 Resolved
Cap off pipe penetration located centerline bottom of watertight bulkhead between foward and engine room compartment I.A.W. 46 CFR 179.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2008
Resolved 17 July 2009
Fire Fighting › Semiportable CO2 Fire Extinguishers › Pressure
Issued 13 September 2007 Resolved
Perform required hydrostatic tests for semiportable CO2 cylinders I.A.W. 46 CFR 176.810.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2008
Resolved 17 July 2009
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 21 September 2006 Resolved
Current weaklink was only rated for buoyant apparatus of 6-21. Replace current weaklink for buoyant apparatus with weaklink for a rating of 21 or more persons.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2006
Resolved 21 September 2006
Resolution: Weaklink with rating of 21 or more persons provided and installed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 August 2005 Resolved
Missing Operational instructions to be at station near tanks.
Condition: Improper/Lack of Maintenance
Due 24 September 2005
Resolved 31 August 2005
Engineering › Bilge Water Management System › Not Operational
Issued 22 August 2005 Resolved
Excessive Oil/Water waste in bilge compartment below main engines. Clean and Remove slops.
Due 24 September 2005
Resolved 31 August 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 22 August 2005 Resolved
B-1 extinguisher in pilot house laying on deck and missing proper bracket from bulkhead. Install new bracket and mount extinguisher.
Due 24 September 2005
Resolved 31 August 2005
Engineering › Fuel Oil Service System › Hose
Issued 22 August 2005 Resolved
Fuel hose on generator needs chaffing gear installed or replacement of the fuel line on the stbd side outboard.
Due 24 September 2005
Resolved 31 August 2005
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 22 August 2005 Resolved
Stern light has improper lens. Replace with proper freznel type lens.
Due 24 September 2005
Resolved 31 August 2005
Construction/Loadline › Structures › Deck Plating
Issued 22 August 2005 Resolved
Deck access cover has 1/2 inch hole that needs to be plugged or braized to ensure watertight integrity of car deck.
Due 24 September 2005
Resolved 31 August 2005
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 22 September 2004 Resolved
Repair- Fule Oil Leaks, Portside Fule Oil Tank
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2005
Resolved 1 April 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 September 2004 Resolved
Provide, Operational instructions for PKP Fixed fire fighting System.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2005
Resolved 1 April 2005
Construction/Loadline › Hull › Weld
Issued 22 September 2004 Resolved
Repair weld Fracture steering Gear Compartment.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2005
Resolved 1 April 2005
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 18 September 2003 Resolved
Repair, fix fuel oil leaks on port fuel oil tank. union and pipe to fuel tank.
Due 20 October 2003
Resolved 22 September 2004
Engineering › Fuel Oil Service System › Piping
Issued 18 September 2003 Resolved
Provide chafing gear on fuel oil return line to generator.
Due 20 October 2003
Resolved 22 September 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 September 2003 Resolved
Install reflective material on throw rings.
Due 20 October 2003
Resolved 22 September 2004
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 September 2003 Resolved
Clean oil and water from engine room & after steering bilges.
Due 20 October 2003
Resolved 22 September 2004
Construction/Loadline › Structures
Issued 3 October 2002 Resolved
Reweld fractured welds, angle brackets as marked in port & center fwd spaces and port & stbd wing tanks.
Condition: Unknown
Due 3 November 2002
Resolved 30 December 2002
Engineering › Fuel Oil Service System
Issued 3 October 2002 Resolved
Repair seeping fuel oil pipe union on fill pipe, port f/o tank. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 3 November 2002
Resolved 30 December 2002
Engineering › Fuel Oil Service System
Issued 3 October 2002 Resolved
Secure fuel oil lines to ship's service generator. Make new bracket to attach f/o hard piping. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 3 November 2002
Resolved 30 December 2002
Engineering › Fuel Oil Service System
Issued 3 October 2002 Resolved
Replace broken clamp screw on stbd fuel oil tank shut-off cable. LEGACY COMPONENT DESC: Valve, Control
Condition: Unknown
Due 3 November 2002
Resolved 30 December 2002
Lifesaving
Issued 16 August 2001 Resolved
Conduct a man-overboard and fire drill to the satisfaction of an_x001C_ attending marine inspector prior to operations.
Condition: Unknown
Due 21 August 2001
Resolved 23 August 2001
Fire Fighting
Issued 16 August 2001 Resolved
Clear obstruction in vicinity of semi-portable fire extinguisher on the main deck, stbd side, prior to operations.
Condition: Unknown
Due 21 August 2001
Resolved 23 August 2001
Lifesaving
Issued 16 August 2001 Resolved
Mark life ring with vessel name and install a quick-release clip for the waterlight prior to the compliance date.
Condition: Unknown
Due 21 August 2001
Resolved 23 August 2001
Construction/Loadline
Issued 16 August 2001 Resolved
Replace gaskets on all watertight doors prior to the compliance date.
Condition: Unknown
Due 21 August 2001
Resolved 23 August 2001
Construction/Loadline
Issued 16 August 2001 Resolved
Install a deck railing to emcompass vehicles as required by 46 CFR 177.900 prior to the compliance date.
Condition: Unknown
Due 21 August 2001
Resolved 23 August 2001
Documentation
Issued 16 August 2001 Resolved
Post stability letter, certificate of inspection and emergency instructionsprior to operations.
Condition: Unknown
Due 21 August 2001
Resolved 23 August 2001
Lifesaving
Issued 16 August 2001 Resolved
Log drills and training and required by 46 CFR 185.520 prior to the compliance date.
Condition: Unknown
Due 21 August 2001
Resolved 23 August 2001
Electrical
Issued 16 August 2001 Resolved
Repair or replace battery box liner with a corrosion resistance material prior to the compliance date.
Condition: Unknown
Due 16 August 2001
Resolved 16 August 2001
Fire Fighting
Issued 3 October 2000 Resolved
PORTABLE CO2 15LB FIRE EXTINGUISHER OVERDUE FOR HYDROSTATIC TESTING, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Lifesaving
Issued 3 October 2000 Resolved
LABEL LIFE PRESERVER STOWAGE IN MAIN DECK PASSENGER ACCOMODATION SPACE BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 3 October 2000
Resolved 3 October 2000
Engineering
Issued 3 October 2000 Resolved
REFIT RUBBER LININGS FOR PORT FUEL OIL TANK MOUNTINGS BEFORE THE COMPLIANCEDATE.
Condition: Unknown
Due 3 October 2000
Resolved 3 October 2000
Lifesaving
Issued 3 October 2000 Resolved
REPLACE GRABLINES AND FLOAT LIGHT LANYARD ON LIFE FLOAT BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 3 October 2000
Resolved 3 October 2000
Lifesaving
Issued 3 October 2000 Resolved
REPLACE INOPERABLE FLOAT LIGHT FOR LIFE FLOAT BEFORE THE COMPLIANCE AND PRIOR TO NIGHTTIME OPERATIONS.
Condition: Unknown
Due 17 October 2000
Resolved 6 October 2000
Fire Fighting
Issued 12 October 1999 Resolved
PROVIDE DOCUMENTATION OF CREW TRAINING AND DRILLS FOR FIRE AND MAN- OVERBOARD PRIOR TO CARRYING PASSENGERS AND BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 12 November 1999
Resolved 18 October 1999
Accommodation/Occupational Safety
Issued 12 October 1999 Resolved
LABEL MAIN DECK ENGINEROOM ESCAPE AS PER 46 CFR 185.606 BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Documentation
Issued 12 October 1999 Resolved
PROVIDE AND POST STABILITY LETTER IN WHEELHOUSE AS PER 46 CFR 176.306 BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Lifesaving
Issued 12 October 1999 Resolved
PADDLES DETERIORATED IN LIFE-FLOAT, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Engineering
Issued 12 October 1999 Resolved
REFIT PORT FUEL TANK MOUNTING SADDLE WITH RUBBER LINING PADS BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Accommodation/Occupational Safety
Issued 12 October 1999 Resolved
REMOVE EXISTING AIR RECEIVER FROM SERVICE IMMEDIATELY AND REPLACE WITH U/L OR ASME LISTED TYPE BEFORE THE COMPLIANCE DATE. MEANWHILE EXISTING AIR SYSTEM SHALL NOT BE USED.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Electrical
Issued 12 October 1999 Resolved
RE-ROUTE STARTING CABLES FOR MAIN ENGINE TO PREVENT THEM FROM LYING IN THE BILGE, BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Construction/Loadline
Issued 12 October 1999 Resolved
REPAIR AND ADJUST CLOSURE DOGS ON AFT ENGINEROOM BULHEAD WATERTIGHT DOOR BEFORE GETTING UNDERWAY AND BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Lifesaving
Issued 12 October 1999 Resolved
INSTALL MACHINERY GUARD OVER FIRE PUMP DRIVE COUPLING BEFORE THE COMPLIANCEDATE.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Lifesaving
Issued 19 August 1998 Resolved
Provide one (01) additional Child-sized PFD on board the vessel.
Condition: Unknown
Due 20 August 1998
Resolved 26 August 1998
Lifesaving
Issued 19 August 1998 Resolved
Remove old wet cell battery from engine room.
Condition: Unknown
Due 20 August 1998
Resolved 26 August 1998
Construction/Loadline
Issued 5 October 1995 Resolved
Complete all repairs on worklist dated 05OCT95 at next scheduled drydock.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Fire Fighting
Issued 4 September 1992 Resolved
Service all portable, semi protable and fixed fire extinguishing systems.
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Construction/Loadline
Issued 30 August 1991 Resolved
Repair bilge and fire systems.
Condition: Unknown
Due 30 September 1991
Resolved 4 November 1991
Lifesaving
Issued 30 August 1991 Resolved
Provide 6 red and 6 orange handheld pyrotechnic signals.
Condition: Unknown
Due 30 September 1991
Resolved 4 November 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.