Records from 1995 to 2025. Most recent: inspection, 2 October 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 37
2 October 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8245269
13 December 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7837598
10 October 2023
Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7805743
12 September 2022
Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7552563
6 December 2021
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7363389
19 November 2021
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7351066
17 September 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7314753
24 November 2020
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7101221
9 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6822760
9 September 2019
Drydock Exam · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6807685
26 September 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6549483
1 March 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6364133
4 October 2017
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6280204
27 July 2017
Administrative Inspection · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6222082
17 January 2017
Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 6072572
14 November 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6038349
10 August 2011
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4111169
21 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3878212
24 July 2009
Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3542747
21 August 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3296494
19 July 2007
Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2998021
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806561
12 October 2006
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2798995
27 January 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2602241
10 August 2005
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2455849
21 July 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2140380
4 August 2003
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1855268
29 July 2002
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1653657
16 August 2001
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1457004
17 August 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365919
17 August 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427701
1 February 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 182378
4 September 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396987
15 August 1997
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388341
11 September 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458347
20 November 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 23104
13 September 1995
Hull Examination · Initial Construction-Excluding Oversight · Inclining Experiment · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454259
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 December 2023
Resolved
Ring life buoy must be marked in clearly legible block capital letters with the vessel's name and must be marked with Type II retroreflective material, name and retroreflective material is faded and needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2024
Resolved 21 December 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2023
Resolved
Lifefloat must be marked in clearly legible block capital letters with the vessel's name and must be marked with Type II retroreflective material, name and retroreflective material is faded and needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2024
Resolved 14 December 2023
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 13 December 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date publications, vessel did not have a COLREGS on board. Provide a COLREGS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2024
Resolved 21 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 December 2023
No resolution recorded
Vessels operating on an Oceans Route must have an interconnected fire detection system in compliance with 46 cfr 181.450.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 October 2023
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Watertight penetrations leading from the machinery space, in the vicinity of the steering pumps to the engine room were not watertight.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2023
Resolved
The materials and construction of fuel lines, including pie, tube, and hose must comply with the requirements of this paragraph. Fuel piping was deteriorated in the vicinity of the emergency escape from the engine room.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 13 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 November 2021
Resolved
Vessels shall have a fire hose for each hydrant. Port side fire hose had several leaks throughout. Hose was condemned in front of inspectors. Hose was replaced prior the completion of the Inspection.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 November 2021
Resolution: Replaced prior to completion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 November 2021
Resolved
Vessel on an ocean service route shall have sufficient lifefloats for intended service. Lifefloats had not been properly maintained. 3 lifefloats did not have adequate retro-reflective tape and another had a broken floating waterlight. *Vessel is limited to day time operations until waterlights have been replaced. *Vessels passenger count is restricted to 49 until all reflective tape has been replaced.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 November 2021
Resolution: Replaced Prior to completing the Inspection
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 19 November 2021
Resolved
Vessels shall be fitted with ground tackle sufficient for the vessels service. Anchor and hawsers where not installed and/or ready to be released.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 November 2021
Resolution: Replaced prior to inspection completion.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 November 2021
Resolved
Vessel shall not be in a condition where the vessel is considered unsafe. Galley Distribution panel was missing a blank in the panel make the panel a potential shock hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 7 December 2021
Resolution: Covered with blank.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 November 2021
Resolved
Vessel shall not be in a condition where the vessel is considered unsafe. Electric panel in the pilot house indicated a H2S detector was off. There is not detector onboard. Installed wires need to be blanked off and housed or a blank needs to be installed in the panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2021
Resolved 7 December 2021
Resolution: Blank installed, and wire put in junction box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2021
Resolved
Vessel shall not be in a condition where the vessel is considered unsafe. Engine Exhausts were missing sufficient insulation. Install more insulation at the discharge point.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2021
Resolved 7 December 2021
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 November 2021
Resolved
Discharge ends of vent pipes shall be fitted with removable flame screens or flame arrester which shall consist of a single screen or at least 30 x 30 mesh. Install flame screen at both fuel tank vent openings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2021
Resolved 7 December 2021
Resolution: Vent/Pipes were marked correctly
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 November 2020
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weatherdeck.
Both shut off valve lines found with too much slack to effectively close from outside the space. Port valve line found with wasted away wire clamp. 2 valve wheels also found to be wasted.
Slack to be removed from lines. Port wire clamp to be replaced. 2 valve wheels to be replaced.
46 CFR 182.20-40(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2020
Resolved 28 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 November 2020
Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe.
Exhaust pipe lagging securing device found to be loose.
Lagging to be re-wired.
46 CFR 182.15-20(g)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 November 2020
Resolution: Deficiency rectified to the satisfaction of the attending Coast Guard inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 November 2020
Resolved
The material specification shall show that the rigid nonmetallic material possesses characteristics adequate for its intended service and environment and shall be approved for use by the Officer in Charge, Marine Inspection.
Flexible non-metallic joint on stbd outboard M/E found to be crushed between both connection points.
Flexible non-metallic joint to be replaced with material suitable for gap distance.
46 CFR 182.40-1(a)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2020
Resolved 21 December 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 November 2020
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.
Port M/E crankcase pressure gauge missing on cover, resulting in an electrical hazard.
Opening in panel to be covered.
46 CFR 183.01-15(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2020
Resolved 21 December 2020
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 24 November 2020
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel.
Broken/fractured welds found as follows: 02 in space fwd of collision bulkhead, 04 found in PAX compartment void, 04 found in fuel tank void.
Make satisfactory repairs to welds.
Approved extension until scheduled dry-dock.
46 CFR 177.10-1(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 September 2021
Resolved 17 September 2021
Resolution: Welds completed
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 24 November 2020
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel.
Petition bulkhead stbd side in PAX compartment void found to be excessively bulging.
Bulge to be cropped and renewed.
Approved extension until dry-dock.
46 CFR 177.10-1(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 September 2021
Resolved 17 September 2021
Resolution: Petition bulkhead fixed during drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2019
Resolved
valve located on the #3 needs to be adjusted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2019
Resolved 14 October 2019
Resolution: adjusted valve in accordance with specifications
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 October 2019
Resolved
Ring buoy needs to have new retro-reflexive tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2019
Resolved 10 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 October 2019
Resolved
Repair life-float on starboard side of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2019
Resolved 10 October 2019
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 13 September 2017
Resolved
VESSEL NAME AND HAILING PORT MISSING FROM STERN. NAME AND HAILING PORT MUST BE CLEARLY MARKED ON STERN. 46CFR185.605(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 4 October 2017
Resolution: Crew painted vessel name and hailing port on the stern of vessel.
Fire Fighting › Nozzles › Condition
Issued 13 September 2017
Resolved
MULTI-PURPOSE FOAM NOZZLE IN POOR CONDITION. REPLACE NOZZLE. 46CFR181.15-10(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 4 October 2017
Resolution: Vessel has been provided with a new multi-purpose foam nozzle.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 September 2017
Resolved
INSTALL DSC FOR 01 VHF RADIO ON NAVIGATION BRIDGE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 4 October 2017
Resolution: Third party technician installed DSC for 01 VHS radio on navigation bridge.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 October 2010
Resolved
Replace battery boxes in E/R IWO aft bulkhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 October 2010
Resolved 25 October 2010
Resolution: Replaced battery box tops
Construction/Loadline › Hull › Weld
Issued 24 July 2009
Resolved
Make repairs to the fractured welds in way of the transom's structural members in the lazerette.
Action required: 705 - Other - as specified
Resolved 11 August 2009
Resolution: Repairs were made to the welds and found in satisfactory condition.
Construction/Loadline › Structures › Deck Plating
Issued 24 July 2009
Resolved
Crop and renew the fractures in the deck just forward of the port outboard engine room soft patch.
Action required: 705 - Other - as specified
Resolved 11 August 2009
Resolution: Engine room fractures forward of the port outboard engine soft patch were repaired and tested at 70 PSI with no apparent leaks. Repair found to be satisfactory.
Construction/Loadline › Hull › Bottom Plating
Issued 24 July 2009
Resolved
Replace all cutlass bearings in way of all propeller shafts.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Cutlass bearings were replaced and found in satisfactory conditon upon inspection. Vessel was authorized to be put back in water.
Construction/Loadline › Hull › Side Shell
Issued 24 July 2009
Resolved
Make proper repairs to cargo deck rails in way of fractured welds.
Action required: 705 - Other - as specified
Resolved 10 August 2009
Resolution: Repairs were made and found to be satisfactory.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 August 2005
Resolved
NOTED SEVERAL CRACKED WELDS IN WAY OF VERTICAL FRAMES IN AFT STEERING. REPAIR AS MARKED. INSPECTOR TO LOOK AT REPAIRS AT THE ANNUAL INSPECTION IN ABOUT 10 DAYS.
Action required: 705 - Other - as specified
Due 10 August 2005
Resolved 10 August 2005
Engineering › Fuel Oil Service System › Valve, Control
Issued 1 August 2005
Resolved
DEMONSTARTE PROPER OPERATION OF THE STARBOARD REMOTE FUEL OIL SHUT OFF VALVE.
Action required: 705 - Other - as specified
Due 10 August 2005
Resolved 1 August 2005
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 1 August 2005
Resolved
CROP AND RENEW APPROX 18IN OF #4 INBOARD FRAME PORT SIDE STEERING COMPARTMENT.
Action required: 705 - Other - as specified
Due 10 August 2005
Resolved 10 August 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 July 2004
Resolved
Properly secure guard for fire monitor coupling as required by 46 CFR 177.960.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 July 2004
Resolved 21 July 2004
Resolution: Vessel representative properly secured guard for the fire monitor coupling.
Fire Fighting › Fire Hoses › Condition
Issued 21 July 2004
Resolved
Provide a new fire hose for the port fire station located on the main deck as required by 46 CFR 181.320(b)(1).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 July 2004
Resolved 21 July 2004
Resolution: Vessel representative provide a new fire hose.
Electrical › Electric Supply System (service)
Issued 4 August 2003
Resolved
Properly secure all wiring under the pilothouse console. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 4 August 2003
Resolution: resolved
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 August 2003
Resolved
Install chafing gear on the port outboard main engine and port generator fuel supply hoses. LEGACY COMPONENT DESC: fuel piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2003
Resolved 4 August 2003
Resolution: installed.
Construction/Loadline › Structures
Issued 4 August 2003
Resolved
Properly adjust the watertight doors at the following locations: engine room forward entrance, generator compartment entrance, and rudder room entrance. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2003
Resolved 4 August 2003
Resolution: Properly adjusted and proved opeartional and watertight.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 4 August 2003
Resolved
Install a B-V type fire extinguisher to comply with carriage requirements of the portable tank endorsement on the vessels COI prior to onloading portable tanks. LEGACY COMPONENT DESC: Number
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 5 August 2003
Resolution: B-V semi-portable extinguisher installed.
Engineering › Steering Gear System
Issued 4 August 2003
Resolved
Install chafing gear on four hydraulic hoses located on the port and starboard rudder tables. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2003
Resolved 4 August 2003
Resolution: installed.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 August 2003
Resolved
Install pipe hangers on the raw water suction piping for the port inboard main engine and the fuel supply piping for the port outboard main engine. LEGACY COMPONENT DESC: Raw water suction
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2003
Resolved 4 August 2003
Resolution: installed
Electrical › Lighting (emergency)
Issued 4 August 2003
Resolved
Install new batteries in the engine room forward emergency lights. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2003
Resolved 4 August 2003
Resolution: installed
Electrical › Electric Supply System (service)
Issued 4 August 2003
Resolved
Properly splice and secure cabling for the aft deck flood light located on the pilothouse level. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 4 August 2003
Resolution: corrected