Passenger Barge (Inspected) · Barge class · Built 1950s · USCG Heartland District (CGD-H) · Other hulls named PRINCESS
PRINCESS is a 1952 passenger barge (inspected). The Coast Guard has recorded 69 inspections since 1985, most recently in March 2021, along with 118 deficiencies.
Records from 1985 to 2021. Most recent: inspection, 1 March 2021.
- Built
- 1952
- Last inspected
- 1 March 2021
- Documentation
- No Operation - PM · documentation file of 10 September 2026
- Deficiencies
- 118 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
264372
42790
Flag
UNITED STATES
—
Maury page id
psix-42790
Inspections, by type
…with no type recorded6
Years with a record
34 calendar years (1985–2021)
The 69 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)70.0 ft × 22.0 ft × 4.4 ft
Registered tonnagegross 61 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFRANK H. JOHNSTON · CINCINNATI, OH, UNITED STATES · built 1952
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDAYTON, KY
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger Barge (Inspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 69
1 March 2021
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7148115
12 May 2020
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6952435
23 May 2019
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6696294
27 March 2018
COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6381066
7 June 2017
DAPI Audit · Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6173296
14 June 2016
Annual Inspection · MTSA/ISPS Verification · Internal Structural Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5945126
26 May 2016
Spot Check · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5909524
4 January 2016
Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5793683
22 May 2015
MTSA Verification · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5131846
23 May 2014
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4857170
20 April 2012
Annual Inspection · DAPI Audit · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4285821
3 November 2011
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4181618
18 February 2011
Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3947779
1 April 2010
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3710163
26 March 2009
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3448009
17 October 2008
MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3348368
4 September 2008
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3318494
30 April 2008
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3195790
9 April 2008
DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3181100
26 September 2007
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3071381
18 September 2007
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3060645
2 July 2007
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2980890
29 March 2007
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2889157
29 March 2007
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2898181
30 August 2006
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2763318
9 August 2006
COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2741624
9 August 2006
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2764087
8 November 2005
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2530559
27 April 2005
MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2347494
14 October 2004
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2220635
13 April 2004
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2033836
27 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995458
28 October 2003
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1937415
16 September 2002
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1676844
27 August 2002
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1667869
3 October 2001
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1074132
27 August 2001
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1469707
19 October 2000
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1408632
27 October 1999
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1372800
14 April 1999
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1125071
3 September 1998
COI Inspection · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1375563
11 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1193744
27 May 1994
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 861676
28 April 1994
COI Inspection · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 860265
15 October 1993
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1146660
28 July 1993
Plan Review "T" Boat
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1442036
23 April 1993
COI Inspection · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1358098
21 April 1993
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1148956
20 April 1993
Deficiency Check · Examination of Repairs
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 838336
13 March 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 952500
20 February 1992
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 959245
14 May 1991
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 909616
4 April 1991
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1235388
5 April 1990
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1218100
14 June 1989
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1040281
13 April 1989
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1039795
29 April 1988
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1347343
10 February 1988
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1020182
1 May 1987
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1336221
29 April 1987
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1020317
23 April 1987
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1008384
1 October 1986
Deficiency Check
Physical examination · MSO CINCINNATI · Activity 1314552
28 July 1986
Deficiency Check
Physical examination · MSO CINCINNATI · Activity 1301736
14 July 1986
Deficiency Check
Physical examination · MSO CINCINNATI · Activity 992847
13 June 1986
Type not recorded
No type recorded · MSO CINCINNATI · Activity 992961
9 May 1986
COI Inspection
Physical examination · MSO CINCINNATI · Activity 993975
26 August 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 1294828
18 June 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 979570
15 May 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 1287747
Deficiency record · 118
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 March 2021
Resolved
Vessel drydock examination date is 31 JAN 2021. Owner failed to schedule drydock examination. A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and internal structure examination at least every five years. Vessel shall receive drydock examination by a Coast Guard marine inspector prior to departure to the satisfaction of the attending Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 May 2019
Resolved
Repair cracked weld located beneath life jacket storage where the stanchion connects to the 2nd deck.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 23 May 2019
Resolved
The base of the stanchions that support the 2nd deck canopy show signs of deterioration. Determine the extent of deterioration and devise a repair proposal to the satisfaction of a USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019
Resolved
The aft stairway to the 2nd deck's railing shows signs of deterioration. Devise a repair proposal to the satisfaction of a USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019
Resolved
Remove water in aft compartment for inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2019
Resolved
Each life jacket kept in a storage container must be readily available. Replace rusted latch on the aft storage container, 2nd deck.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 May 2019
Resolved
All cables and wiring must be protected from weather. Shore tie shows signs of chaffing. Repair or replace to the satisfaction of USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2019
Resolved
At least one ring buoy must be fitted with a floating waterlight, unless the vessel is limited to daytime operation, in that case no floating waterlight is required. Waterlight is not functioning.
Fire Fighting › Fire Main › Pressure
Issued 7 June 2017
Resolved
The minimum capacity of the power fire pump shall be 50 gpm at a pressure of not less than 60 psi at the pump outlet. The pump outlet shall be fitted with a pressure gauge. During this period, you may continue to carry passengers, provided that you utilize the fire pump on the towing vessel and a portable pump. As discussed, both pumps must be outfitted and readily available in the event of an eme
Engineering › Bilge Water Management System › Valve
Issued 14 June 2016
Resolved
Repair or replace to original the bilge system valve in the bow
compartment and its corresponding reach rod above deck IAW 46 CFR 56.50(c)(1)
Engineering › Bilge Water Management System › Strainer
Issued 14 June 2016
Resolved
Each individual bilge suction shall be fitted with a suitable bilge
strainer. Remove excessive scaling on all bilge strainers and
suction lines to allow for proper function. If it is determined
that oxidation has deteriorated the bilge suction beyond repair,
replace in kind. Be prepared to test the function of any and all
of the vessels bilge suction lines IAW 46 CFR 56.50 (g).
Construction/Loadline › Hull › Hull Plating
Issued 14 June 2016
Resolved
Submit repair proposal/plan for wastage and pin holes identified
in overhead/ceiling at aft bulkhead and turn in the bilge in void
#7(sewage tank compartment) and in way of decking under the
starboard stairway to upper deck for review/satisfaction to
USCG marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2016
Resolved
Repair exposed wiring on lighting indicated on top deck.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 June 2016
Resolved
Ring buoy line damaged from UV exposure. Replace.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 June 2016
Resolved
Remove expired first aide equipment from vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2016
Resolved
Each flexible cord and cable must be without splices or taps.
Remove and replace spliced wire on kitchen equipment
indicated.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 May 2015
Resolved
Life ring grabline around the life ring worn. Replace line
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 22 May 2015
Resolved
Pinholes noted in bulkhead between the A/B void. Bulkhead to be repaired during drydock in FEB16.
Stability › Weathertight Integrity › General
Issued 20 April 2012
Resolved
Replace broken glass on the entrance door to the main deck passenger accommodation on the port side and one broken window on the main deck port side.
Fire Fighting › Fire Hoses › Material
Issued 20 April 2012
Resolved
Provide a commercially lined fire hose at fire station #1 on the main deck that conforms to UL standard 19 or a hose that is listed and labeled by an independent laboratory recognized by the Commandant to replace the unlined hose currently on the station and demonstrate proper operation of the fire main system prior to carrying passengers.
Fire Fighting › Fire Hydrants › Condition
Issued 20 April 2012
Resolved
Make repairs to the seized valve at the hydrant at fire station #2 on the upper deck, port side and demonstrate proper operation of the same prior to carrying passengers.
Engineering › Bilge Water Management System › Pump
Issued 20 April 2012
Resolved
Demonstrate proper operation of the bilge dewatering system prior to carrying passengers.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 April 2012
Resolved
Properly stuff exposed wiring into the light fixture located on the port side, upper deck and properly secure two light fixtures located on the upper deck and as discussed with the vessel representative.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 April 2012
Resolved
Crop and renew wasted sections of the passenger rails located on the upper deck as identified and discussed with the vessel representative.
Construction/Loadline › Structures › Deck Plating
Issued 20 April 2012
Resolved
Crop and renew wasted section of deck plating underneath the bilge manifold in the port side, aft compartment to the satisfaction of an attending Coast Guard Marine Inspector.
Stability › Incline Test › General
Issued 2 November 2011
Resolved
Provide proof that the vessel is in compliance with the new AAWPP as required in the guidance in CG-543 Policy Letter 11-03 dated April 8, 2011. If the operator is unable to certify compliance through one of the methods outlined in enclosure 1 of the Policy Letter, the total passengers will be reduced to 174 with total persons onboard reduced to 177.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 1 April 2010
Resolved
Make repairs to emergency lighting prior to caring passengers.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 April 2010
Resolved
Place donning instructions and check all locks at all lifejacket stations prior to carrying passengers.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 1 April 2010
Resolved
Install bilge and test bilge alarm prior to carrying passengers.
Construction/Loadline › Hull › Hull Plating
Issued 4 September 2008
Resolved
Repair cracks in stern above the water line starboard side in area where tug mates with barge.
Construction/Loadline › Hull › Stiffener
Issued 4 September 2008
Resolved
Repair cracked horizontal stiffener located in aft compartment on starboard stern area where tug mates with barge.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 April 2008
Resolved
Replace broken light fixture aft port side step area.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 April 2008
Resolved
Replacce cable clamps on lights located on upper deck.
Documentation › Logs/Records › MIS Form
Issued 9 April 2008
Resolved
Show proof of MIS submission.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 April 2008
Resolved
Replinish First Aid Kit
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 29 March 2007
Resolved
Place four adult life jackets onboard to comply with required number on certificate of inspection.
Documentation › Logs/Records › MIS Form
Issued 29 March 2007
Resolved
Provide copy of annual MIS report or letter from consortium that report has been sent to USCG HQ.
Documentation › Logs/Records › Drug Test Records
Issued 29 March 2007
Resolved
Contact consortium/ MRO to ensure compliance with regulations on negative diluted sample.
Lifesaving › Lifebuoys › Serviceable
Issued 9 August 2006
Resolved
Repalce two worn life bouys.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 August 2006
Resolved
Prove proper operation of bilge high level alarm.
Electrical › Electric Supply System (service) › Cable
Issued 9 August 2006
Resolved
Properly hard wire boarding light.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 August 2006
Resolved
Replace starboard running light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 August 2006
Resolved
Replace expired aspirin and eye wash in first aid kit.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 August 2006
Resolved
Repair/ replace light fixture full of water on upper deck.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 9 August 2006
Resolved
Repalce broken window lower deck forward.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 August 2006
Resolved
Vessel representative requested we require all kapak life jackets be repalced by March 31, 2007.
Personnel › Training › First Aid/CPR
Issued 9 August 2006
Resolved
Provide proof that atleast half of the vessel crew has first aid and CPR training.
Lifesaving › Hand Flares › Storage
Issued 9 August 2006
Resolved
Place hand held flares in water proof container and properly mark.
Lifesaving › Hand Flares › Not on Board
Issued 8 November 2005
Resolved
Place on board three additional flares, for a total of six.
Lifesaving › Hand Flares › Storage
Issued 8 November 2005
Resolved
Place all flares in bright colored watertight container, marked DISTRESS SIGNALS.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 8 November 2005
Resolved
Place donning instruction in all life jacket lockers.
Operations/Management › Equipment Service/Testing
Issued 28 October 2003
Resolved
Vessel is not to engage in passengers for hire until a credit dry-dock is completed to the satisfaction of the attending Marine Inspector.
Construction/Loadline › Hull
Issued 28 October 2003
Resolved
Back gouge or grind crack in stem and re-weld. LEGACY COMPONENT DESC: Bottom Plating
Construction/Loadline › Hull
Issued 28 October 2003
Resolved
Re-weld three washed out welds on bow as marked by CG. LEGACY COMPONENT DESC: Weld
Construction/Loadline › Hull
Issued 28 October 2003
Resolved
Drill stop or gouge out cracks in transome port side and re-weld. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 28 October 2003
Resolved
Remove dirt, water, mud and muck from #1, 5, 6, 7 voids to allow CG inspector to see bottom plating and condition of welds and palting.
Electrical › Electric Supply System (service)
Issued 27 August 2002
Resolved
Remove electrical extension cords behind beverage bar on main deck.. LEGACY COMPONENT DESC: Cable
Accommodation/Occupational Safety › Medical/First Aid
Issued 27 August 2002
Resolved
Provide Coast guard approved first aid kit to be stored on barge. LEGACY COMPONENT DESC: Medicine Chest
Lifesaving › Lifejacket/PFD (General)
Issued 27 August 2002
Resolved
Supply three (03) adult size life jackets and one (01) child size life jacket to meet required count as per COI. Max passengers allowed is 221 due to number of jackets onboard. LEGACY COMPONENT DESC: Condition
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 27 August 2002
Resolved
Provide proper mounting bracket for B-II dry-chem extingisher located in supply room. LEGACY COMPONENT DESC: Mounting Bracket
Electrical › Electric Supply System (service)
Issued 27 August 2002
Resolved
Remove dead end electrical cable from old air conditioning units on second deck. LEGACY COMPONENT DESC: Cable
Electrical
Issued 27 August 2001
Resolved
REMOVE OR PROVE PROPER OPERATION OF EMERGENCY GENERATOR.
Accommodation/Occupational Safety
Issued 27 August 2001
Resolved
REPAIR/REPLACE METAL WASTEAGE IN BOTH HEADS WHERE BULKHEAD MEETS MAIN DECK.
Navigation
Issued 27 August 2001
Resolved
INSTALL PUBLIC ADDRESS SYSTEM AS REQUIRED BY 46CFR 184.610.
Lifesaving
Issued 27 August 2001
Resolved
MAKE REPAIR TO AFT STBD STAIRWAY IN WAY OF METAL WASTEAGE.
Lifesaving
Issued 3 September 1998
Resolved
UNTIL 28 ADDITIONAL ADULT SIZE LIFE PRESERVERS ARE PLACED ONBOARD, THE MAXIMUM NUMBER OF ADULT PASSENGERS ALLOWED ONBOARD IS LIMITED TO 196.
Construction/Loadline
Issued 28 April 1994
Resolved
REMOVE ALL DEBRIS FROM COMPARTMENT/VOID SPACES.
Lifesaving
Issued 28 April 1994
Resolved
CONDUCT UNDERWAY DRILLS PRIOR TO GETTING UNDERWAY WITH THE M/V [name withheld] DAVE IS AWAITING REPAIR OF THE STBD. PADDLE WHEEL SHAFT.
Fire Fighting
Issued 28 April 1994
Resolved
REMOVE THE INOPERABLE FIRE AND BILGE PUMP. PUMP IS IN EXCESS OF NUMBER REQUIRED.
Lifesaving
Issued 28 April 1994
Resolved
PROPERLY STENCIL NAME OF VESSEL ON RESCUE BOAT.
Navigation
Issued 23 April 1993
Resolved
INSTALL PROPER NAVIGATION LIGHTS COMPLYING WITH THE 1972 COLREGS FOR FLASHING AMBER, AND PORT AND STARBOARD RUNNING LIGHTS. (INCLUDING FLAT BLACK SHIELDS AND APPROVED FIXTURES). DEFICIENCY IS TO BE COMPLETED PRIOR TO COMPLIANCE DATE.
Construction/Loadline
Issued 23 April 1993
Resolved
DEMONSTRATE PROPER OPERATION OF AUXILIARY GASOLINE POWERED BILGE PUMP PRIORTO COMPLIANCE DATE.
Construction/Loadline
Issued 23 April 1993
Resolved
PROPERLY DISPLAY NAME AND HAILING PORT AS WELL AS DRAFT MARKS PRIOR TO COMPLIANCE DATE. _x001C_
Lifesaving
Issued 23 April 1993
Resolved
PROPERLY LABEL CHILD SIZE LIFE PRESERVER STOWAGE COMPARTMENT FROM A "29" COUNT TO A "27" COUNT PRIOR TO COMPLIANCE DATE. _x001C_
Construction/Loadline
Issued 23 April 1993
Resolved
PRIOR TO COMPLIANCE DATE OR NEXT CHANGE OF CARPET, PROPERLY WELD ALL VOID COMPARTMENT BULKHEADS TO MAIN DECK WITH CONTINUOUS WELD.
Lifesaving
Issued 23 April 1993
Resolved
PROPERLY REPAIR OR REPLACE RESCUE BOAT NO LATER THAN COMPLIANCE DATE. _x001C_ BOW KEEL PIECE HAS APPROXIMATELY 8"x13" FIBERGLASS REPAIR OVER ALUMINUM.
Engineering
Issued 20 February 1992
Resolved
REPAIR AND PROVE SATISFACTORY OPERATION OF STARBOARD PROPULSION DRIVE CHAINPRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Construction/Loadline
Issued 20 February 1992
Resolved
RAISE BILGE SUCTION STRAINER APPROXIMATELY ONE INCH OFF BILGE BOTTOM IN "F"VOID COMPARTMENT NOT LATER THAN THE COMPLIANCE DATE.
Lifesaving
Issued 20 February 1992
Resolved
REPLACE TWO REJECTED (DAMAGED) LIFE PRESERVERS WITH SERVICEABLE LIFE PRESERVERS PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Construction/Loadline
Issued 20 February 1992
Resolved
ENLARGE LIMBER HOLES IN FOREPEAK FRAMES TO PERMIT WATER TO FLOW TO BILGE SUCTION STRAINER AREA, NOT LATER THAN THE COMPLIANCE DATE.
Construction/Loadline
Issued 20 February 1992
Resolved
RELABEL BILGE PIPING MANIFOLD AT EACH BILGE SUCTION LINE CONTROL VALVE NOT LATER THAN THE COMPLIANCE DATE.
Documentation
Issued 20 February 1992
Resolved
POST CERTIFICATE OF INSPECTION IN A CONSPICUOUS PLACE, VISIBLE TO THE PASSENGERS, NOT LATER THAN THE COMPLIANCE DATE.
Construction/Loadline
Issued 20 February 1992
Resolved
MAKE PERMANENT REPAIRS (BY WELDING) TO WASTED HOLES IN EXTERIOR BULKHEAD INMENS HEAD NOT LATER THAN THE COMPLIANCE DATE.
Lifesaving
Issued 20 February 1992
Resolved
PROVIDE ONE ADDITIONAL RING LIFE BUOY (AT LEAST 24" IN DIAMETER) PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Lifesaving
Issued 20 February 1992
Resolved
ATTACH AT LEAST 60 FEET OF LINE TO RING LIFE BUOY PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Construction/Loadline
Issued 20 February 1992
Resolved
INSTALL SAFETY GUARDS OVER BOTH FIRE AND BILGE PUMP MOTOR DRIVE SHAFTS NOT LATER THAN THE COMPLIANCE DATE.
Construction/Loadline
Issued 20 February 1992
Resolved
WELD BOTH SIDES OF ALL VOID COMPARTMENT WATERTIGHT BULKHEADS WHERE THEY JOIN SIDESHELL PLATING AND DECK PLATING NOT LATER THAN THE COMPLIANCE DATE.
Construction/Loadline
Issued 4 April 1991
Resolved
MAKE PERMANENT PEPAIRS TO PIN HOLES AROUND THROUGH BULKHEAD PIPES LOCATED PORTSIDE FORWARD BULKHEAD IN #6 VOID COMPARTMENT NOT LATER THAN THE COMPLIANCE DATE.
Construction/Loadline
Issued 4 April 1991
Resolved
MAKE PERMANENT REPAIRS TO SMALL SIDE SHELL HOLE LOCATED PORTSIDE AT DECKLINE IN THE #4 VOID COMPARTMENT NOT LATER THAN THE COMPLIANCE DATE.
Accommodation/Occupational Safety
Issued 4 April 1991
Resolved
REPAIR LOOSE PORTSIDE BOW GUARD RAIL STANCHION NOT LATER THAN THE COMPLIANCE DATE.
Lifesaving
Issued 4 April 1991
Resolved
PROVIDE THREE APPROVED ADULT LIFE PRESERVERS NOT LATER THAN THE COMPLIANCE DATE. TOTAL PERSONS ALLOWED ON BOARD THE VESSEL IS RESTRICTED TO 231 UNTILTHREE COAST GUARD INSPECTED LIFE PRESERVERS ARE PROVIDED.
Lifesaving
Issued 4 April 1991
Resolved
PROVIDE SIX APPROVED CHILD SIZE LIFE PRESERVERS NOT LATER THAN THE COMPLIANCE DATE. AN APPROVED COAST GUARD INSPECTED CHILD SIZE LIFE PRESERVER SHALL BE PROVIDED FOR EACH CHILD BE ON BOARD.
Construction/Loadline
Issued 5 April 1990
Resolved
MAKE PERMANENT REPAIRS TO THE VESSEL'S SEA CHEST AND RECONNECT THE FIRE ANDBILGE SYSTEM AT THE NEXT DRYDOCKING BUT NO LATER THAN THE COMPLIANCE DATE. THE TEMPORARY PIPE SEA SUCTION AT THE STERN OF THE VESSEL SHALL BE MAINTAINED UNTIL PERMANENT REPAIRS ARE MADE.
Construction/Loadline
Issued 5 April 1990
Resolved
PROVIDE VENTILATION TO ALL CLOSED SPACES IN ACCORDANCE WITH 46 CFR 177.20 AT THE NEXT DRYDOCKING, BUT NOT LATER THAN THE COMPLIANCE DATE.
Lifesaving
Issued 13 April 1989
Resolved
PROVIDE TWENTY ADULT SIZE PFD'S. THE VESSEL'S CAPACITY IS REDUCED TO 208 PASSENGERS UNTIL THESE ARE ONBOARD AND INSPECTED.
Fire Fighting
Issued 13 April 1989
Resolved
REPLACE THE TWO 1-1/2 INCH FIRE HOSES WITH NEW HOSES OF APPROVED TYPE.
Construction/Loadline
Issued 13 April 1989
Resolved
REPLACE THE CRACKED CHECK VALVE ON THE BILGE SUCTION LINE IN THE BOW COMP- ARTMENT.
Fire Fighting
Issued 29 April 1987
Resolved
PROVIDE A FIRE & BILGE PUMPS THAT WILL OPERATE AT THE REQUIRED PRESSURE AND CAPACITY, THIS ITEM IS TO BE COMPLETED BY THE NEXT VESSEL HULL EXAM BUT NO LATER THAN 31 MARCH 1988
Lifesaving
Issued 13 June 1986
Resolved
PROVIDE STORAGE FOR THE CHILDREN'S LIFE JACKETS AND PROPERLY MARK THE STOR-AGE.
Construction/Loadline
Issued 13 June 1986
Resolved
REPAIR OR REPLACE TO MAKE OPERABLE THE HAND WHEEL ON THE DISCHARGE VALVE FROM THE AFT BILGE/FIRE PUMP.
Electrical
Issued 13 June 1986
Resolved
PROPERLY WIRE THE ELECTRICAL LEAD FOR THE VIDEO CAMERA ON THE BOW.
Electrical
Issued 9 May 1986
Resolved
PROVIDE A SEPARATE SOURCE OF POWER FOR THE BILGE PUMPS IN ACCORDANCE WITH 46 CFR 182.25-10(C).
Fire Fighting
Issued 9 May 1986
Resolved
INSTALL AND ATTACH GUARDS ON BOTH FIRE/BILGE PUMP SHAFTS.
Fire Fighting
Issued 9 May 1986
Resolved
PROVIDE PROPER BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS.
Construction/Loadline
Issued 9 May 1986
Resolved
PROVIDE CHECK VALVES ON ALL BILGE SUCTION LINES IN ACCORDANCE WITH 46 CFR 182.25-5(C).
Construction/Loadline
Issued 15 May 1985
Resolved
PROPERLY MARK THE VESSEL'S HULL IN ACCORDANCE WITH 46 CFR 67.15-3.
Electrical
Issued 15 May 1985
Resolved
REPLACE THE NEWLY-INSTALLED LIGHTS ON THE VESSEL'S STERN WITH LIGHTS AP- PROVED FOR MARINE SERVICE OR MANUFACTURED TO UL 595 STANDARD. THESE LIGHTSARE NOT TO BE CONNECTED TO A SOURCE OF POWER UNTIL REPLACED WITH PROPER FIXTURES.
Lifesaving
Issued 15 May 1985
Resolved
REPLACE THE RESCUE BOAT WITH ONE CONSTRUCTED IN ACCORDANCE WITH 46 CFR 160.056.
Fire Fighting
Issued 15 May 1985
Resolved
PROVE THE PROPER OPERATION OF THE FIRE/BILGE PUMPS.
Lifesaving
Issued 15 May 1985
Resolved
PROVIDE THE VESSEL'S THIRD LIFE RING.
Electrical
Issued 15 May 1985
Resolved
REPAIR THE COVER FOR THE SWITCH BOX FOR THE RIGHT FIRE PUMP, MAKING IT FUNCTIONAL.
Electrical
Issued 15 May 1985
Resolved
REMOVE THE DEAD ENDED ELECTRICAL LEAD FOR THE REMOVED RIVER WATER PUMP.
Fire Fighting
Issued 15 May 1985
Resolved
SERVICE ONBOARD FIRE EXTINGUISHERS AS NECESSARY.
Unknown
Issued 15 May 1985
Resolved
PROVIDE AN ADEQUATE SUPPORT BRACKET FOR THE ONBOARD HELIUM BOTTLE.
Electrical
Issued 15 May 1985
Resolved
PROVIDE A GLOVE FOR THE LIGHT ON THE BOW.
Electrical
Issued 15 May 1985
Resolved
THE NEWLY-INSTALLED WIRE LEADS FOR THE SPEAKER SYSTEM HAVE NON-ACCEPTABLE SPLICES. PLACE PROPER SPLICES IN JUNCTION BOXES OR REPLACE SPEAKER WIRE.
Electrical
Issued 15 May 1985
Resolved
PROVIDE A MORE STABLE BRACKET ASSEMBLY FOR THE AMBER LIGHT.
Fire Fighting
Issued 15 May 1985
Resolved
PROVIDE PROPER SUPPORT BRACKETS FOR ALL ONBOARD FIRE EXTINGUISHERS.