CANBY is a 1952 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 1985, most recently in December 1996, along with 9 deficiencies.

Records from 1985 to 1996. Most recent: inspection, 6 December 1996.

Built
1952
Last inspected
6 December 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-42801

Inspections, by type

…with no type recorded4
Years with a record 12 calendar years (1985–1996)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Net Ton
14 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 24

6 December 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1187545
5 April 1995 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1394302
16 September 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 224099
2 September 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 215787
24 January 1994 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1469763
4 March 1993 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1453998
5 March 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1317363
25 February 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 953972
25 February 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 954226
8 May 1991 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1222348
25 March 1991 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 997763
4 March 1991 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1218343
4 February 1991 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 901691
22 March 1990 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 903519
16 February 1990 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 910603
1 June 1989 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1043523
5 May 1989 Plan Review "T" Boat · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1208342
24 February 1989 Plan Review "T" Boat
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1198139
29 February 1988 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1336947
31 August 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1002250
6 April 1987 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1002237
30 March 1987 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1002047
8 May 1986 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1305594
13 March 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 980545

Deficiency record · 9

Lifesaving
Issued 25 February 1992 Resolved
RECOIL LINE ATTACHED TO RING BUOY SUCH THAT IT CAN BE QUICKLY UNCOILED WHILTE LAUNCHING.
Condition: Unknown
Due 25 February 1992
Resolved 25 February 1992
Lifesaving
Issued 25 February 1992 Resolved
REPAIR STRAP ON DESIGNATED ADULT LIFEJACKET. PASSENGERS LIMITED TO NUMBER OF JACKETS AVAILABLE MINUS CREW.
Condition: Unknown
Due 25 February 1992
Resolved 25 February 1992
Lifesaving
Issued 4 February 1991 Resolved
POST PLACARD FOR DONNING AND SECURING LIFE JACKETS. AS PER REF. IN 46 CFR 185.25-1(d)(1)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Electrical
Issued 4 February 1991 Resolved
REPLACE BATTERY CHARGER WITH APPROVED TYPE. MAKE PROPER ELECTRICAL CONNECTIONS. AS PER REF. IN 46 CFR 183.05-20._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Construction/Loadline
Issued 16 February 1990 Resolved
REPAIR CRACKED WELD ON STIFFENER ON THE NORTH END, DOWNSTREAM SIDE OF THE FERRY AND TIGHTEN ALL LOOSE CLEATS.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Fire Fighting
Issued 6 April 1987 Resolved
INSTALL A POWER-DRIVEN, SELF PRIMING FIRE PUMP IN ACCORDANCE WITH 46 CFR 181.10-1
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Accommodation/Occupational Safety
Issued 6 April 1987 Resolved
INSTALL A BILGE PUMP AND PIPING SYSTEM IN ACCORDANCE WITH 46 CFR 182.25.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Fire Fighting
Issued 6 April 1987 Resolved
PROVIDE A FIRE MAIN SYSTEM INCLUDING FIRE HYDRANT, HOSE AND NOZZLE IN ACCORDANCE WITH 46 CFR 181.15
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Electrical
Issued 13 March 1985 Resolved
REMOVE OR PERMANENTLY INSTALL BATTERY CHARGER FOR 12 VOLT BATTERY IN THE PILOT HOUSE IN ACCORDANCE WITH 46 CFR 183.10 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 March 1985
Resolved 13 March 1985