Records from 1985 to 1997. Most recent: inspection, 16 June 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
16 June 1997
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 775262
26 April 1996
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1470915
24 May 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1400241
12 May 1995
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1431534
10 May 1994
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1025316
10 May 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1334368
18 May 1993
Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1133487
14 May 1992
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1264537
26 June 1991
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 909388
23 May 1991
Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1194119
16 April 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 904412
5 April 1990
Re-Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 909363
16 May 1989
COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1202092
10 June 1988
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1044972
7 March 1988
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1335030
2 June 1987
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1337021
27 May 1986
Credit Drydock · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1302176
13 June 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 983141
Lifesaving
Issued 26 April 1996
Resolved
Ring buoy needed new lifeline and retroflective tape. Cleared 3 May 1996.
Condition: Unknown
Due 22 May 1996
Resolved 22 May 1996
Lifesaving
Issued 26 April 1996
Resolved
Vessel was missing the Emergency checkoff procedures. Cleared 3 May 1996.
Condition: Unknown
Due 22 May 1996
Resolved 22 May 1996
Lifesaving
Issued 26 April 1996
Resolved
Weaklink missing tag. Cleared 29 May 1996.
Condition: Unknown
Due 6 July 1996
Resolved 6 July 1996
Navigation
Issued 26 April 1996
Resolved
Owner had outdated copies of Sub-chapter "T" regs and Rules of the Road. Cleared 29 May 1996.
Condition: Unknown
Due 6 July 1996
Resolved 6 July 1996
Lifesaving
Issued 26 April 1996
Resolved
3 Orange Smoke expired. Cleared 3 May 96
Condition: Unknown
Due 22 May 1996
Resolved 22 May 1996
Navigation
Issued 24 May 1995
Resolved
Tide table for 1995 not onboard. Obtain 1995 tide table._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 1995
Resolved 16 October 1995
Navigation
Issued 24 May 1995
Resolved
Replace bracket or renew mounting bolts(larger diameter) for upper rudder post bracket. Mounting bolt holes enlarged allowing for slop/movement of bracket._x001C_ _x001C_
Condition: Unknown
Due 7 June 1995
Resolved 16 October 1995
Construction/Loadline
Issued 24 May 1995
Resolved
Underdeck longitudnal aft wasted. Renew in like kind._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 1995
Resolved 16 October 1995
Accommodation/Occupational Safety
Issued 24 May 1995
Resolved
Remount pump for MSD. Pump not secured from shifting._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 1995
Resolved 16 October 1995
Electrical
Issued 24 May 1995
Resolved
Remove discontinued dead end wires in wheelhouse._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 1995
Resolved 16 October 1995
Documentation
Issued 23 May 1991
Resolved
PROVIDE CURRENT FCC SAFETY CERTIFICATE
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Fire Fighting
Issued 23 May 1991
Resolved
PROVIDE APPROPIRATE BRACKET FOR 2ND B-II FIRE EXTINGUISHER
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Lifesaving
Issued 23 May 1991
Resolved
MAKE UP BA SEA PAINTER AND GRAB LINES PROPERLY
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Electrical
Issued 23 May 1991
Resolved
REFASTEN ELECTRIC WIRE RUN FWD OF ENGINE STBD SIDE
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Lifesaving
Issued 23 May 1991
Resolved
REPLACE FLOATS IN LIFELINE OF BA OR INSTALL BUOYANT LINE
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Fire Fighting
Issued 23 May 1991
Resolved
MOUNT B-I FIRE EXTINGUISHER PROPERLY
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Construction/Loadline
Issued 23 May 1991
Resolved
REPLACE ROTTEN PLANKS STBD SIDE, 1ST PLANK ABOVE CHINE, 1/3 TO 1/2 LENGTH OF VESSEL FROM BOW AS APPROPRIATE AND AT LEAST 5' INSERTS
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Construction/Loadline
Issued 23 May 1991
Resolved
DOUBLE CLAMP OR PLUG THROUGH HULL VALVE PORT SIDE OF ENGINE
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Engineering
Issued 23 May 1991
Resolved
CONDUCT THOROUGH UNDERWAY TEST SHOWING OPEATION OF MACHINERY INSTALLATION AND ALL ASSOCIATED SYSTEMS
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Navigation
Issued 23 May 1991
Resolved
RE-BUSH RUDDER POST
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Navigation
Issued 23 May 1991
Resolved
SHOW/CONDUCT SUCCESSFUL RADIO OPERATION
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Construction/Loadline
Issued 16 May 1989
Resolved
CROP & RENEW IN FULL THE FIRST 4 PLANKS PORT & STBD
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Construction/Loadline
Issued 16 May 1989
Resolved
PROVIDE CAPTIVE CHAINS FOR ALL DECK HATCHES EXPOSED TO THE WEATHER
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Lifesaving
Issued 16 May 1989
Resolved
PROVIDE GRAB LINES FOR BOUYANT APPARATUS. LINE SHALL BE 12' SECURED IN THECENTER, BLACK 3/8" LINE
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Engineering
Issued 16 May 1989
Resolved
MAKE BOAT AVAILABLE FOR UNDERWAY EXAM
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Navigation
Issued 16 May 1989
Resolved
PROVIDE CURRENT FCC STATION LICENSE
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Construction/Loadline
Issued 16 May 1989
Resolved
DOUBLE CLAMP HEAD INTAKE SAE VALVE
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Navigation
Issued 10 June 1988
Resolved
PROVIDE CHARTS FOR AREA OF OPERATION, TIDE TABLES, COAST PILOT SMALL PASSENGER REGULATIONS AND NAVIGATION REGULATIONS/RULES
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Engineering
Issued 10 June 1988
Resolved
RENEW COUPLING TO WET HORIZONTAL EXHAUST AFT OF EXHAUST MANIFOLD
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Construction/Loadline
Issued 10 June 1988
Resolved
PROPERLY CAP THROUGH HULL FITTING STBD SIDE JUST AFT OF COLLUSION BULKHEAD
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Construction/Loadline
Issued 10 June 1988
Resolved
HAUL VESSEL FOR EXAMINATION OF KEEL/KEELSON WHERE LEAKING FORWARD OF RUDDER
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Construction/Loadline
Issued 10 June 1988
Resolved
MINIMIZE LEAKAGE FROM PLANK IN WAY OF STERN AND STBD CHINE
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Documentation
Issued 10 June 1988
Resolved
PROVIDE VALID STICKER TO CERTIFICATE OF DOCUMENTATION
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Electrical
Issued 10 June 1988
Resolved
RENEW TERMINAL CONNECTOR TO NEGATIVE LUG ON AFT BATTERY
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Accommodation/Occupational Safety
Issued 10 June 1988
Resolved
DEMONSTRATE PROPER OPERATION OF INSTALLED MANSFIELD TYPE I MSD OR REMOVE. VSL SHALL BE PROVIDED WITH ONE MSD WHILE CARRYING PASSENGERS.
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Navigation
Issued 10 June 1988
Resolved
PROVIDE APPROVED STERNLIGHT THAT MEETS 1972 COLREGS.
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Engineering
Issued 2 June 1987
Resolved
PROVIDE SHUT-OFF VALVE ADJACENT TO FUEL FILTER.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Electrical
Issued 2 June 1987
Resolved
RENEW BATTERY BOX TO 12 VOLT BATTERY.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Navigation
Issued 2 June 1987
Resolved
RENEW PACKING TO RUDDER STOCK AND THROUGH BOLTS (FOR RUDDER) TO MINIMIZE LEAKAGE.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Engineering
Issued 2 June 1987
Resolved
RENEW NON-CG APPROVED FUEL LINE AND ELIMINATE HOSE CLAMPS.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Documentation
Issued 2 June 1987
Resolved
PLACE CERTIFICATE OF DOCUMENTATION ON BOARD VESSEL.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Fire Fighting
Issued 2 June 1987
Resolved
PROVIDE ADDITIONAL B-II FIRE EXTENGUISHERS IN LIEU OF B-III 20 POUNT DRY CHEMICAL.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Construction/Loadline
Issued 2 June 1987
Resolved
PROVIDE PLUGS FOR 8 OVERBOARD SCUPPERS.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Construction/Loadline
Issued 2 June 1987
Resolved
RENEW FLEXIBLE HOSE (PLASTIC) TO TWO ELECTRIC BILGE PUMPS.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987