This record may be incomplete: the most recent inspection recorded for this vessel was 33 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
1319 - Regulatory (Subpart C or D), Gross Ton
1319 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-42830
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 18
9 September 1993Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 841500
10 August 1993COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 830877
18 May 1992Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1134172
16 April 1991Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1232085
23 April 1990Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1222293
13 October 1989Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1212268
25 July 1989Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1341835
12 April 1989COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1210203
24 January 1989Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1205425
6 December 1988Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 897012
6 June 1988Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1033446
5 November 1987Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 501407
13 April 1987COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1319373
8 September 1986Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1321445
8 September 1986Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1322515
30 May 1986Credit Drydock · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 997787
4 June 1985Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 982190
26 March 1985Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1288864
PROVIDE GAGING REPORT AND ORIGINAL PLATE THICKNESS OR RECALCULATED PLATE THICKNESS FOR A NEW BARGE OF EQUAL DIMENSIONS USING ABS RULES.
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989
Documentation
Issued 25 July 1989Resolved
CREDIT DRYDOCK DUE 25JUL92. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 20 June 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 12 April 1989Resolved
INSTALL MISSING BOLTS IN P/R BHD PORTLIGHTS AND LIGHT FIXTURES PRIOR TO ENERGIZING.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Deck/Cargo
Issued 12 April 1989Resolved
REPAIR AND TEST LEAK AT PORT C. PUMP RELIEF VALVE PIPE WELD AND SUCTION SIDE THREADED FITTING.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Electrical
Issued 12 April 1989Resolved
PREPARE TO DEMONSTRATE GENERATOR INCLUDING GROUND DETECTION.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Construction/Loadline
Issued 12 April 1989Resolved
PERMANENTLY MARK NAME AND HOME PORT ON STERN OF VESSEL.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Construction/Loadline
Issued 12 April 1989Resolved
REPAINT DRAFT MARKS.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Construction/Loadline
Issued 12 April 1989Resolved
COMPLETE REPAIRS TO BOW ACCESS HATCHES AND AFT ACCESS HATCHES.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Deck/Cargo
Issued 24 January 1989Resolved
ARRANGE FOR DRYDOCK EXAMINATION OR OTHER ACCEPTABLE METHOD TO DETERMINE THEINTEGRITY OF THE #3 PORT AND #5 STARBOARD CARGO TANKS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 January 1989
Resolved 24 January 1989
Navigation
Issued 6 June 1988Resolved
PRIOR TO OPERATING VESSEL AT NIGHT THE NAVIGATIONAL LIGHTS ARE TO BE MADE OPERATIONAL.
Condition: Unknown
Due 6 June 1988
Resolved 6 June 1988
Electrical
Issued 6 June 1988Resolved
REPLACE MISSING LIGHT GLOBES FROM TWO (2) EXPLOSION PROOF LIGHTS IN PUMP ROOM.
Condition: Unknown
Due 6 June 1988
Resolved 6 June 1988
Deck/Cargo
Issued 30 May 1986Resolved
DISABLE FUEL LINE AND ELCTRICAL SUPPLY TO VESSELS BOILER.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Deck/Cargo
Issued 26 March 1985Resolved
PROVE OPERATION OF ALL CARGO PUMP RELIEF VALVES.
Condition: Unknown
Due 26 March 1985
Resolved 26 March 1985