MALIHINI

MALIHINI is a 1945 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in May 2025, along with 79 deficiencies and 4 casualty investigations between 2004 and 2017.

Records from 2004 to 2025. Most recent: inspection, 21 May 2025.

Built
1945
Last inspected
21 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 May 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK6995
Flag
UNITED STATES
Maury page id
psix-42833

Documentation record

Registered dimensions (L × B × D)72.5 ft × 19.5 ft × 8.9 ft
Registered tonnagegross 94 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHIGGINS INDUSTRIES INC · NEW ORLEANS, LA, UNITED STATES · built 1945
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PUBLIC VESSEL - MEXICAN NAVY Unknown · MISLE 1856445 · 8 February 2025 · activity 8078532

Inspection history · 24

21 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8140203
26 February 2025 Deficiency Check · Damage Survey · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8071011
21 February 2025 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8082553
8 February 2025 Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8077611
8 February 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8078532
15 April 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7895700
13 June 2023 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7710944
4 May 2023 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7677564
17 January 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7624470
26 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7459624
7 December 2021 Drydock Exam · In-Service Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7327362
23 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7233703
10 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6973350
17 December 2019 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6874828
14 August 2019 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6774781
11 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6537843
7 June 2018 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6427781
15 November 2017 Damage Survey · Hull Examination · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6304420
16 May 2017 Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6149116
16 May 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6156445
29 March 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6113620
25 October 2016 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6029637
24 October 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6029735
10 March 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5830680

Deficiency record · 79

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2025 Resolved
Electrical equipment must be installed to protect from electrical hazards. Electrical wiring underneath operating station had 2 electrical sockets missing face plates and one breaker box missing its cover. Also, one electrical socket on the starboard side E/R was missing its face place. Properly cover to prevent potential shock or fire hazards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 27 May 2025
Resolution: Received photo of corrected def. ALl SAT.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 21 May 2025 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing MMSI and LAT/LONG for DSC operation. Update radio to include MMSI,LAT,LONG and notify local OCMI. 47 CFR 80.905
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2025
Resolution: Received photo of corrected def. ALl SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 May 2025 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Light in Laz was missing light cover. Replace and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 27 May 2025
Resolution: Received photo of corrected def. ALl SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in engine compartment that are going to be used for an additional camera. Install camera or remove dead end wires and notify local OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2025
Resolved 27 May 2025
Resolution: Received photo of corrected def. ALl SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2025 Resolved
Vessel required to have one, 24" ring lifebuoy fitted with 60' lifeline and floating water light attached with a corrosion resistant clip to allow quick disconnect. Vessel did not have lifeline onboard. Provide proper arrangement of ring lifebuoy, lifeline, and waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 2 June 2025
Resolution: Received photo of attached lifeline and light. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 21 May 2025 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: (1) Spaces storing carbon dioxide— ‘‘CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.’’. (2) Spaces protected by carbon dioxide—‘‘ CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.’’ (3) Spaces into which carbon dioxide might migrate— ‘‘CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. DISCHARGE INTO NEARBY SPACE CAN COLLECT HERE. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED VACATE IMMEDIATELY.’’ Vessel spaces were not marked. Mark spaces appropriately and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 18 June 2025
Resolution: Received photos of posted placards. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 February 2025 Resolved
Vessel has damage to hull port side, amidships, approximately 4' above waterline cause by a vessel collision and enacted temporary repairs. Vessel is permitted one time transit to South Coast Shipyard in Newport Beach to conduct permanent repairs. Vessel is permitted to transit without passengers, in fair weather only. Notify local [name withheld]/LB once vessel arrives and submit a repair proposal to Sector LA/LB for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2025
Resolution: Repairs to vessel were conducted satisfactory IAW repair proposal.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 8 February 2025 Resolved
Vessel reported damage to hull portside, amidships, approximately 4' above waterline cause by vessel collision. Make vessel available for damage survey by USCG marine inspectors and submit a repair proposal for OCMI approval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2025
Resolution: Issued new 835 so the vessel can transit to LA/LB for permanent repairs. See MISLE activity #8082553
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 April 2024 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry 12 flares. Vessel is short two flares. Acquire two (02) additional flares.
Action required: 10 - Deficiency Rectified
Resolved 15 April 2024
Resolution: Vessel got 2 addditional flares.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 April 2024 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The marking is not required on a life jacket carried to meet a temporary need for additional life jackets, if the life jacket has the name of another vessel or company marked on it. For an immersion suit, the name of the person to whom the immersion suit is assigned is an acceptable alternative to the name of the vessel. 01 of the vessels required ring life buoy did not have the vessel's name on it. Write the vessel name on ring life buoy.
Action required: 10 - Deficiency Rectified
Resolved 15 April 2024
Resolution: Crewmember wrote name of vessel on life ring buoy in front of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 April 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel had 02 dead-end wires in the engine room and 01 in the midship void. Properly repair or remove dead-end wires.
Action required: 10 - Deficiency Rectified
Resolved 15 April 2024
Resolution: Received photo's of removed wires.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 June 2023 Resolved
The painter must: Be of at least 100 feet, Have a breaking strength of at least 680 kilograms (1,500 lbs.),(3000 lbs.) if 50 or more persons, Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light; Be stowed in such a way that it runs out freely. Replace deteriorated life float painter lines with appropriate. Ensure that no stowage is in and around life floats so lines and floats can float free.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2023
Resolution: reattached and organized painter allowing float free.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 June 2023 Resolved
The floating water light must be attached around the body of the life float or buoyant apparatus by a (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least (18 feet) in length. Attach water lights to floats and ensure they are float free.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2023
Resolution: Attached water lights to floats and ensured they are float free.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 June 2023 Resolved
The pump outlet must be fitted with a pressure gauge. Replace fire pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2023
Resolution: Replaced fire pressure gauge
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 June 2023 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Replace wasted retroreflective tape on life rings.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2023
Resolution: Replaced wasted retroreflective tape on life rings.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2023 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Purchase new approved First Aid kit, with ammonia inhalants and aspirin
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2023
Resolution: Purchased new approved First Aid kit, with ammonia inhalants and aspirin
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 May 2022 Resolved
The painter must:Be of at least 100 feet, Have a breaking strength of at least 680 kilograms (1,500 lbs),(3000 lbs) if 50 or more persons, Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light; Be stowed in such a way that it runs out freely. Replace deteriorated life float painter lines with appropriate. Ensure that no stowage is in and around life floats so lines and floats can float free.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2022
Resolution: Replaced painter line and cleared area of obstruction.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 May 2022 Resolved
The floating waterlight must be attached around the body of the life float or buoyant apparatus by a (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least (18 feet) in length. Attach waterlights to floats and ensure they are float free.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2022
Resolution: Attached water lights to life floats with approved lanyard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 May 2022 Resolved
A vessel on an oceans, coastwise, limited coastwise, Six hand red flare distress signals and Six hand orange smoke distress signals or 12 hand red flare distress signals. Replace outdated flares.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 May 2022 Resolved
Each ring life buoy on a vessel must: Be readily accessible, Be stowed in a way that it can be rapidly cast loose. Locate ring bouys around vessel making them accessible be deployed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2022
Resolution: Relocated ring buoy to lower deck.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 May 2022 Resolved
Life floats must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. Place spacers between each float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 16 June 2022
Resolution: Installed wooden spacers between life floats
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 May 2022 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Replace wasted retroreflective tape on life rings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 16 June 2022
Resolution: Installed reflective tape on ring buoys
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 May 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Purchase new approved First Aid kit
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 16 June 2022
Resolution: Purchased new first aid kit.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 26 May 2022 Resolved
Each EPIRB, must be tested monthly, and shall be logged or otherwise documented, as applicable. Test and log EPIRB monthly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2022
Resolved 16 June 2022
Resolution: Tested EPIRB and logged
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 26 May 2022 Resolved
Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Have FCC-licensed technician issue a new Safety Radiotelephony Certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 16 June 2022
Resolution: Provided new FCC Radiotelephony safety certificate.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 May 2022 Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. Replace broken Nozzle on port fire hose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2022
Resolved 16 June 2022
Resolution: Replaced hose nozzle
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 26 May 2022 Resolved
Vessel port side rudder post found to have excessive leaking. Adjust packing to prevent leakage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2022
Resolved 16 June 2022
Resolution: Tightened packing to reduce leaking.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 May 2022 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Junction box identified on stbd side of amidships accommodation space found to be not secured. Secure to prevent movement while underway.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2022
Resolved 27 May 2022
Resolution: Secured Junction box to bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 26 May 2022 Resolved
Center Main diesel engine belt drive unit missing guard. Install machinery guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2022
Resolved 16 June 2022
Resolution: Provided protective guard for all engines.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 May 2022 Resolved
Vessel found to lack efficient means of shutting down ventilation to CO2 protected engine space. Provide means of shutting down ventillation to engine space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2022
Resolved 16 June 2022
Resolution: Installed doors for shutting down ventillation to space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 May 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Wire identified on stbd side of amidships accommodation space found to have outer protective covering wasted away. Repair, remove, or replace damaged wire.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2022
Resolved 27 May 2022
Resolution: Removed damaged wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2022 Resolved
Wet exhaust on center aft main propulsion engine found to be leaking at flex hose, and at the aft bulkhead. Repair wet exhaust to prevent leakage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2022
Resolved 16 June 2022
Resolution: Tightened clamp to prevent leak.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 June 2021 Resolved
Vessel's EPRIB battery was found to be expired as of 01/2021. Provide EPIRB with valid battery. Vessel is restricted to less than 3 miles from shore until corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 24 June 2021
Resolution: Vessel rep provided photo of new battery installed and certificate of replacement.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 June 2021 Resolved
The aft stbd fire hydrant was found with a broken handle on the cut-off valve. Replace valve handle and prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2021
Resolved 16 July 2021
Resolution: Vessel rep provided photo of new valve handle installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 23 June 2021 Resolved
02 life floats located on the wheel house cabin top were found heavily coated in bird feces. Clean life floats to restore bright orange color.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 24 June 2021
Resolution: Vessel rep provided photo of cleaned up life floats.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 June 2021 Resolved
Provide all deck hatches with adequate securing devices.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2021
Resolved 16 July 2021
Resolution: Received photo of corrected def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2021 Resolved
Provide bilge suction piping/flexible hose with double hose clamps. Hose clamps were found missing from flexible hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 24 June 2021
Resolution: Vessel rep provided photo's of installed hose clamps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2021 Resolved
Provide all three main engine #6 injector fuel piping with chafe protection. Replace the stbd engine #6 injector fuel line with factory replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2021
Resolved 16 July 2021
Resolution: Received photo of corrected def.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 June 2021 Resolved
Repair or replace fire main pressure gauge. PSI gauge was found inoperable at time of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2021
Resolved 16 July 2021
Resolution: Received photo of corrected def.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 June 2021 Resolved
Clean and degrease griddle ventilation hood and ducting. Excess grease buildup was found at time of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2021
Resolved 24 June 2021
Resolution: Vessel rep provided photo of griddle hood all cleaned up.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 June 2020 Resolved
VESSEL IS REQUIRED TO HAVE 6 RED HAND FLARES BUT ONLY HAD 4 ONBOARD. VESSEL IS RESTRICTED TO LAKES, BAYS AND SOUNDS ROUTE UNTIL 6 RED HAND FLARES AS REQUIRED FOR OCEANS ROUTE IS ONBOARD AND VERIFIED.
Action required: 705 - Other - as specified
Due 10 June 2020
Resolved 16 June 2020
Resolution: new flares purchased
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 June 2020 Resolved
FORWARD BLKHD IN ENGINE ROOM HAD A RAG STUFFED INTO A PIPING PENETRATION. MAKE PIPING PENETRATIONS WATERTIGHT.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: Rag removed and proper sealant added
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 June 2020 Resolved
VESSELS FIRE PUMP OUTLET PRESSURE GAUGE IS INOPERABLE. REPLACE GAUGE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 10 July 2020
Resolution: gauge replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2020 Resolved
SWITCH BOX IN ENGINE ROOM WAS FOUND WITH 2 SEVERED GROUND WIRES OUTSIDE OF ENCLOSURE. ENSURE WIRES ARE CONNECTED PROPERLY AND CLAMPING IS AROUND THE INSULATION PART OF THE CABLE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: rewired j box
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 June 2020 Resolved
ENSURE FCC STATION RADIO AUTHORIZATION CERTIFICATE IS VALID AND ONBOARD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: updated doc
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 June 2020 Resolved
ENSURE LIFE FLOATS ARE STOWED WITH SPACERS TO SEPARATE EACH FLOAT.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: installed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 June 2020 Resolved
CLEAN AND PAINT LIFE FLOATS STOWED ON WHEEL HOUSE NOT IN SERVICABLE CONDITION
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2020
Resolved 16 June 2020
Resolution: Cleaned sat
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 June 2020 Resolved
INSTALL NEW TYPE 2 RETRO REFLECTIVE TAPE ON LIFE FLOATS NOT IN SERVICEABLE CONDITION
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2020
Resolution: renewed as required
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 June 2020 Resolved
LABEL LIFE FLOAT PADDLES WITH VESSEL'S NAME
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: labeled
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2020 Resolved
RENEW FADED LIFE RING ON PORT SIDE WHEEL HOUSE
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2020 Resolved
LABEL LIFE RING ON AFT WHEEL HOUSE WITH VESSEL'S NAME
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 16 June 2020
Resolution: labeled
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 August 2019 Resolved
Replace port side life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 21 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 August 2019 Resolved
Reapply retro-reflective tape on center life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 21 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 August 2019 Resolved
Clean life floats on top of pilote house.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 21 January 2020
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018 Resolved
MMSI: Vsl is broadcasting invalid MMSI, CLSN: Vsl is broadcasting Invalid Call Sign, NAME: Vsl is broadcasting incorrect Name, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 August 2019
Lifesaving › Hand Flares › Quantity
Issued 7 June 2018 Resolved
Provide 02 red hand or smoke flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2018
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 June 2018 Resolved
Repair or replace nav lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2018
Lifesaving › Lifebuoys › Serviceable
Issued 7 June 2018 Resolved
Replace damaged/worn lifering.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2018
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 7 June 2018 Resolved
Repair/replace faulty buoyant light on buoyant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 June 2018 Resolved
Provide proof of engine shutdown/override for fixed firefighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2018
Lifesaving › Buoyant Apparatus › Lifeline
Issued 7 June 2018 Resolved
Replace grab lines on the identified 02 buoyant apparatus.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2018
Resolved 28 June 2018
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 June 2018 Resolved
Replace grab line on identified life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2018
Resolved 28 June 2018
Navigation › Piloting/Steering › Marine Charts
Issued 7 June 2018 Resolved
Provide valid nav charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2018
Resolved 28 June 2018
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 7 June 2018 Resolved
Replace lights on the identified 03 lifejackets. Total person count reduced by 03 people until rectified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2018
Resolved 28 June 2018
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 June 2018 Resolved
Replace the missing 02 adult lifejackets. Total person count reduced by 02 until rectified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2018
Resolved 28 June 2018
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 June 2018 Resolved
Provide vsl specific emergency instruction list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2018
Resolved 28 June 2018
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 7 June 2018 Resolved
Provide waste management plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2018
Resolved 28 June 2018
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 June 2018 Resolved
Repair/replace bilge alarm in aft bunk room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2018
Resolved 28 June 2018
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2018 Resolved
Remove fastners as indicated by Marine Inspector prior to receiving credit for drydock.
Action required: 705 - Other - as specified
Resolved 14 March 2018
Resolution: Fasteners removed/replaced to the satisfaction of the LMI. See Fastener Inspection Record for more details.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 February 2018 Resolved
Make permanent repairs to all frames and floors called out by MI for credit dry dock.
Action required: 705 - Other - as specified
Resolved 5 June 2018
Resolution: Proper repairs made and vessel conducted satisfactory sea trial.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 February 2018 Resolved
Repair/replace damaged planking and chine log in order to receive credit for drydock.
Action required: 705 - Other - as specified
Resolved 5 June 2018
Resolution: Proper repairs made and vessel conducted satisfactory sea trial.
Construction/Loadline › Hull › Bottom Plating
Issued 18 May 2017 Resolved
Vessel taking on water IVO starboard side chine forward; determine the extent of the damage and submit repair plan for approval.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2017
Resolution: Plan reviewed and approved.
Construction/Loadline › Hull › Bottom Plating
Issued 16 May 2017 Resolved
Crop and renew the wood damage to the satisfaction of the attending Marine inspector> prove Sea Trials after the vessel is repaired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2017
Resolution: Sea trials witnessed and repairs complted IAW approved repair plan.
Construction/Loadline › Hull › Bottom Plating
Issued 16 May 2017 Resolved
Removed G-10 material at fwd staboard side and remove splash zone on starboard side forward bilge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 May 2017
Engineering › Fuel Oil Service System › Piping
Issued 25 October 2016 Resolved
High pressure fuel line on starboard engine from filter to main has leak. Needs replaced. Make repair and demonstrate proper operation of the vessel to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2016
Resolution: High pressure fuel line replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 October 2016 Resolved
Provide cover or guard on all four engines.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 1 November 2016
Resolution: Guards provided on equipment.
Fire Fighting › Fire Main › Pressure
Issued 10 March 2016 Resolved
Renew firepump gauge and prove proper operation.
Condition: Improper/Lack of Maintenance
Due 18 March 2016
Resolved 14 March 2016
Resolution: Renewed gauged and tested
Fire Fighting › Fire Main › Condition
Issued 10 March 2016 Resolved
Make proper repairs to the firemain piping and prove proper operation
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 14 March 2016
Resolution: Firemain piping was repaired and tested
Lifesaving › Lifebuoys › Serviceable
Issued 10 March 2016 Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Upper life ring renewed.

Casualty record · 4

1 April 2004Routine · role: Involved in a Marine Casualty · activity 2035403
17 July 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3001579
24 October 2016Routine · role: Involved in a Marine Casualty · activity 6029735
16 May 2017Routine · role: Subject of Search and Rescue · activity 6156445
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.