MAURY USCG vessel records
← All vessels

PRONTO

Built
1953
Last inspected
3 December 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 December 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL6930
Flag
UNITED STATES
Maury page id
psix-42834

Documentation record

Registered dimensions (L × B × D)42.8 ft × 14.7 ft × 4.5 ft
Registered tonnagegross 22 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHORNER & CUMMINGS · SANTA MONICA, CA, UNITED STATES · built 1953
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, fi, reg
DocumentationValid · issued 9 July 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 31 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

3 December 2025 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8286922
22 October 2025 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8257103
11 March 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8092088
22 October 2024 Internal Structural Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8023731
22 February 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7868937
30 November 2023 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847893
9 March 2023 Annual Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7648246
13 December 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7609324
9 March 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7425162
6 December 2021 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7363433
22 July 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7264722
14 December 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7108551
17 March 2020 Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6927967
10 December 2019 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6870928
25 September 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6821237
28 May 2019 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6697209
15 March 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6372573
22 February 2018 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6359495
28 March 2017 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6113658
12 April 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5852433

Deficiency record · 31

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 October 2025 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] of vessels fire buckets had a capacity of 5 gallons and missing lanyard. Drill holes to 2 1/2 gallons and attach lanyard that reaches water when on bow.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2025
Resolution: Received photos of new fire buckets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 October 2025 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 A first-aid kit must be easily visible and readily available to the crew. First aid kit has several expired items. Provide USCG-approved kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2025
Resolved 21 November 2025
Resolution: Received photo of new first aid kit.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 October 2025 Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The initial inspection may include an inspection of the following items: Certificates and operating manuals, including certificates issued by the FCC. . FCC certificate was expired. Provide inspection and valid FCC certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2025
Resolved 2 December 2025
Resolution: New cert issued to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2025 Resolved
Waterlights should be serviceable and batteries replaced annually if not marked with an expiration date. 03 Waterlight were inoperable with an unmarked batter. Provide serviceable waterlight and replace battery. Vessels passenger count is reduced by 03 until proof of new waterlight has been received by the local OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2025
Resolved 10 April 2025
Resolution: Received phots of new lights. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 March 2025 Resolved
Machinery and fuel tank spaces must be separated by boundaries that prevent the passage of vapors. The lazarette has a penetration to the engine room that is not vapor tight. Provide a proper seal to prevent the passage of vapors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 10 April 2025
Resolution: Received photos of patched hole. ALL SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 March 2025 Resolved
Vessels forward removable engine room hatch was damage. Send repairs to local OCMI once completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2025
Resolved 21 April 2025
Resolution: Received photo of new engine room hatch. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 February 2024 Resolved
life raft servicing found to be overdue. Conduct servicing VIA approved third party, provide CG with servicing certificate and proof of correct installation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 22 February 2024 Resolved
Ladder configuration for Person in the water (PIW)scenario scenario found to be incapable of retrieving unconscious person in the water. Provide configuration adequate for all PIW scenarios.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: Improved ladder to be used at lowest point of vessel.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 December 2021 Resolved
Marked deck beam in Lazarette found to have wood rot on STBD side. Need to crop and renew.
Action required: 705 - Other - as specified
Resolved 20 December 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 6 December 2021 Resolved
Remove surface rot spots on port side bottom shell of engine space and re-coat.
Action required: 705 - Other - as specified
Resolved 17 December 2021
Resolution: Surface rot removed and treated.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 December 2020 Resolved
VESSEL DOES NOT HAVE THE REQUIRED SURVIVAL CRAFT ONBOARD DUE TO ANNUAL SERVICING. DUE TO BEING LOCATED IN OCEANSIDE HARBOR, VESSEL'S ROUTE IS RESTRICTED TO LAKES/BAYS/SOUNDS NOT TO EXCEED 1 NM FROM SHORE. PRIOR TO OPERATING SEAWARD OF THE BOUNDARY LINE, VESSEL MUST HAVE CRAFT ONBOARD AND STOWED PROPERLY.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 December 2020
Resolution: IBA ONBOARD
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 June 2020 Resolved
Provide vessel with valid FCC Station License.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 23 July 2020
Resolution: Received copy of valid FCC station license.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 June 2020 Resolved
Provide vessel with valid FCC safety certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 3 September 2020
Resolution: Received copy of valid safety certificate.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 June 2020 Resolved
Provide vessels DSC Radio with MMSI and Lat./Long. information.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 3 September 2020
Resolution: Received photo of VHF radio with MMSI and LAT/LONG information displayed.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 25 September 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
Action required: 10 - Deficiency Rectified
Resolved 25 September 2019
Resolution: Educated operator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 26 December 2019
Resolved 29 January 2021
Resolution: Def Rectified to satisfaction of OCMI...[name withheld]
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2019 Resolved
All escape hatches and emergency exits used as means of escape must be marked on both sides in clearly legible letters that says "EMERGENCY EXIT, KEEP CLEAR". Emergency exit hatch from accommodation space was not marked on the top side in the galley. Mark emergency escape hatch with proper marking on both sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2019
Resolved 19 March 2020
Resolution: Escape markings installed.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 25 September 2019 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from passenger and crew accomdation spaces below the main deck. Vessel did not have lighting at either port or starboard side emergency exits. Provide emergency lighting for both emergeny exits.
Action required: 705 - Other - as specified
Due 26 December 2019
Resolved 19 March 2020
Resolution: Lighting installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 September 2019 Resolved
Fire extinguishing equipment installed on a vessel must be maintained in accordance with a recognized industry standard acceptable to the Commandant. Fire extinguisher in re-charge zone. Re-charge or replace extinguisher with kextinguiser that is in the proper zone.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2019
Resolution: New fire extinguisher installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 May 2019 Resolved
Make bilge alarm operational in fore peak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2019
Resolution: Bilge alarm rewired. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 28 May 2019 Resolved
Make emergency lighting operational in accomadation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 21 June 2019
Resolution: Emergency light operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 May 2019 Resolved
Make auxiliary means of steering operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 29 May 2019
Electrical › Electrical Distribution System (service) › Conductor
Issued 21 March 2018 Resolved
Remove electrical shock danger from main panel
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2018
Resolved 20 April 2018
Resolution: Panel openings were blanked
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 21 March 2018 Resolved
Renew portside fuel tank fill hose and install bonding wire
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2018
Resolved 20 April 2018
Resolution: Hose was renewed
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 March 2018 Resolved
Install guard around bilge pump pulley
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2018
Resolved 20 April 2018
Resolution: Guard installed
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 March 2018 Resolved
Vessel is overdue for annual inspection. Complete satisfactory annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2018
Resolution: Conducted annual inspection
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 March 2018 Resolved
Properly shield both P&S emergency fuel shutoff valves
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2018
Resolved 21 March 2018
Resolution: FOS
Personnel › Certificates/Documents/Licenses › License, Master
Issued 28 March 2017 Resolved
Provide proof of proper mariner credentials.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 March 2017 Resolved
Replace worn line on ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 28 March 2017
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 28 March 2017 Resolved
Provide proof of valid FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 28 March 2017
Navigation › Piloting/Steering › Marine Charts
Issued 28 March 2017 Resolved
Update or replace navigation pubs and charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 12 April 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.