← All vessels
PRONTO
Passenger (Inspected) · Passenger Ship class · Built 1950s · USCG Southwest District (CGD-SW) · Other hulls named PRONTO
PRONTO is a 1953 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1985, most recently in December 2025, along with 81 deficiencies and 1 operational control.
Records from 1985 to 2025. Most recent: inspection, 3 December 2025.
- Built
- 1953
- Last inspected
- 3 December 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 81 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
265231
WDL6930
42834
Flag
UNITED STATES
368155450
Maury page id
psix-42834
Inspections, by type
…with no type recorded6
Years with a record
39 calendar years (1985–2025)
The 81 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)42.8 ft × 14.7 ft × 4.5 ft
Registered tonnagegross 22 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHORNER & CUMMINGS · SANTA MONICA, CA, UNITED STATES · built 1953
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 9 July 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
17 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL6930MMSI 368155450 · active · compulsorily equipped · granted 23 July 2020, expires 23 July 2030
WDE4462MMSI 367353520 · expired · compulsorily equipped · granted 1 May 2008, cancelled 7 July 2018
WE7236MMSI not assigned · expired · compulsorily equipped · granted 13 April 1998, cancelled 20 September 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 81
3 December 2025
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8286922
22 October 2025
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8257103
11 March 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8092088
22 October 2024
Internal Structural Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8023731
22 February 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7868937
30 November 2023
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7847893
9 March 2023
Annual Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7648246
13 December 2022
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7609324
9 March 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7425162
6 December 2021
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7363433
22 July 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7264722
14 December 2020
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7108551
17 March 2020
Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6927967
10 December 2019
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6870928
25 September 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6821237
28 May 2019
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6697209
15 March 2018
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6372573
22 February 2018
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6359495
28 March 2017
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6113658
12 April 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5852433
7 December 2015
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5776627
14 May 2014
Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4857532
27 March 2014
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4823490
29 June 2012
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4357229
26 June 2012
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4345181
9 December 2011
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4204960
16 February 2011
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3938702
23 March 2010
Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3701556
11 February 2010
Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3660520
20 April 2009
Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3439441
4 June 2008
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3227215
31 January 2008
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3139649
24 April 2007
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2908790
21 February 2006
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2589151
16 February 2006
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2583250
12 May 2005
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2347401
3 May 2004
Deficiency Check · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2051175
12 January 2004
Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1982532
9 May 2002
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1601671
9 April 2002
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1601711
7 February 2002
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1484945
16 March 2001
Damage Survey · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1373605
2 March 2001
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1418853
6 February 2001
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1403298
31 March 2000
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1384405
6 March 2000
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1466106
15 April 1999
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1369124
26 January 1999
Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 789901
5 August 1998
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 796637
20 April 1998
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1471515
3 March 1998
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1406268
25 February 1997
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1406054
20 February 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 214461
5 February 1997
Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1354091
28 January 1997
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1377929
16 July 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1095432
6 February 1996
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1383164
29 December 1995
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1363445
26 January 1995
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1471956
9 December 1994
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1432878
29 March 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 648777
19 March 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 228964
5 January 1994
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1163217
20 December 1993
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 853905
27 January 1993
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 826654
15 December 1992
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1140397
16 December 1991
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1262352
7 November 1991
Hull Examination · Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1252592
16 January 1991
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 900394
27 December 1990
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 918604
30 January 1990
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 918542
26 January 1990
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 911519
24 January 1990
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1220252
31 March 1989
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 887413
5 April 1988
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1037345
1 April 1988
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1302457
10 June 1987
Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1336933
11 May 1987
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1019501
2 April 1986
COI Inspection · Deficiency Check · Credit Drydock
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 996866
5 June 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1287384
29 May 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 978718
Deficiency record · 81
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 October 2025
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] of vessels fire buckets had a capacity of 5 gallons and missing lanyard. Drill holes to 2 1/2 gallons and attach lanyard that reaches water when on bow.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 October 2025
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 A first-aid kit must be easily visible and readily available to the crew. First aid kit has several expired items. Provide USCG-approved kit.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 October 2025
Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The initial inspection may include an inspection of the following items: Certificates and operating manuals, including certificates issued by the FCC. . FCC certificate was expired. Provide inspection and valid FCC certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2025
Resolved
Waterlights should be serviceable and batteries replaced annually if not marked with an expiration date. 03 Waterlight were inoperable with an unmarked batter. Provide serviceable waterlight and replace battery. Vessels passenger count is reduced by 03 until proof of new waterlight has been received by the local OCMI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 March 2025
Resolved
Machinery and fuel tank spaces must be separated by boundaries that prevent the passage of vapors. The lazarette has a penetration to the engine room that is not vapor tight. Provide a proper seal to prevent the passage of vapors.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 March 2025
Resolved
Vessels forward removable engine room hatch was damage. Send repairs to local OCMI once completed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 February 2024
Resolved
life raft servicing found to be overdue. Conduct servicing VIA approved third party, provide CG with servicing certificate and proof of correct installation.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 22 February 2024
Resolved
Ladder configuration for Person in the water (PIW)scenario scenario found to be incapable of retrieving unconscious person in the water. Provide configuration adequate for all PIW scenarios.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 December 2021
Resolved
Marked deck beam in Lazarette found to have wood rot on STBD side. Need to crop and renew.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 6 December 2021
Resolved
Remove surface rot spots on port side bottom shell of engine space and re-coat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 December 2020
Resolved
VESSEL DOES NOT HAVE THE REQUIRED SURVIVAL CRAFT ONBOARD DUE TO ANNUAL SERVICING. DUE TO BEING LOCATED IN OCEANSIDE HARBOR, VESSEL'S ROUTE IS RESTRICTED TO LAKES/BAYS/SOUNDS NOT TO EXCEED 1 NM FROM SHORE. PRIOR TO OPERATING SEAWARD OF THE BOUNDARY LINE, VESSEL MUST HAVE CRAFT ONBOARD AND STOWED PROPERLY.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 June 2020
Resolved
Provide vessel with valid FCC Station License.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 June 2020
Resolved
Provide vessel with valid FCC safety certificate.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 June 2020
Resolved
Provide vessels DSC Radio with MMSI and Lat./Long. information.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 25 September 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2019
Resolved
All escape hatches and emergency exits used as means of escape must be marked on both sides in clearly legible letters that says "EMERGENCY EXIT, KEEP CLEAR". Emergency exit hatch from accommodation space was not marked on the top side in the galley. Mark emergency escape hatch with proper marking on both sides.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 25 September 2019
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from passenger and crew accomdation spaces below the main deck. Vessel did not have lighting at either port or starboard side emergency exits. Provide emergency lighting for both emergeny exits.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 September 2019
Resolved
Fire extinguishing equipment installed on a vessel must be maintained in accordance with a recognized industry standard acceptable to the Commandant. Fire extinguisher in re-charge zone. Re-charge or replace extinguisher with kextinguiser that is in the proper zone.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 May 2019
Resolved
Make bilge alarm operational in fore peak.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 28 May 2019
Resolved
Make emergency lighting operational in accomadation space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 May 2019
Resolved
Make auxiliary means of steering operational.
Electrical › Electrical Distribution System (service) › Conductor
Issued 21 March 2018
Resolved
Remove electrical shock danger from main panel
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 21 March 2018
Resolved
Renew portside fuel tank fill hose and install bonding wire
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 March 2018
Resolved
Install guard around bilge pump pulley
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 March 2018
Resolved
Vessel is overdue for annual inspection. Complete satisfactory annual inspection.
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 March 2018
Resolved
Properly shield both P&S emergency fuel shutoff valves
Personnel › Certificates/Documents/Licenses › License, Master
Issued 28 March 2017
Resolved
Provide proof of proper mariner credentials.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 March 2017
Resolved
Replace worn line on ring buoy.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 28 March 2017
Resolved
Provide proof of valid FCC Safety Certificate.
Navigation › Piloting/Steering › Marine Charts
Issued 28 March 2017
Resolved
Update or replace navigation pubs and charts.
Communications › Radio Communications › EPIRB
Issued 7 December 2015
Resolved
Renew Epirb battery (expired) Prior to operating beyond 3nm.
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 December 2015
Resolved
Provide updated version of light list, coast pilot, and tides/current tables.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 7 December 2015
Resolved
Properly label fuel fill stations.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 7 December 2015
Resolved
Prove proper operation of engine room air intake closure devices.
Documentation › Certificates/Documents › Stability Letter
Issued 9 December 2011
Resolved
Vessel failed to meet compliance deadline of Dec 1, 2011 in order to meet new stability weight requirements of 185
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 February 2011
Resolved
pulled 6 adult and 1 child life jacket. Jackets were destroyed on site due to air leaking from kapok type life jackets. reduced vessels pax count to 18 adult a 2 children until jackets are replaced with new.
Engineering › Bilge Water Management System › Piping
Issued 23 March 2010
Resolved
Label bilge manifold in engine space.
Fire Fighting › Fire Bucket › Lanyard
Issued 23 March 2010
Resolved
label fire buckets and provide lanyard for each.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 11 February 2010
Resolved
Sewage pump is secured using plastic zip ties. Properly secure sewage pump.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 31 January 2008
Resolved
Repair minor rot at overhead starboard wooden beam in engine room.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 24 April 2007
Resolved
Replace 3 adult and 1 child life jackets
Navigation › Piloting/Steering › Coast Guard Light List
Issued 24 April 2007
Resolved
Renew light list, CG coast Pilot and area chart
Lifesaving › Lifebuoys
Issued 3 May 2004
Resolved
Renew buoyant lifeline and water light lanyard. LEGACY COMPONENT DESC: Buoyant Lifeline
Electrical › Electrical Distribution System (service)
Issued 9 April 2002
Resolved
Mount spare bait tank pump to mounting plate LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Engineering › Bilge Water Management System
Issued 9 April 2002
Resolved
Install bilge alarm lights LEGACY COMPONENT DESC: Interface Detector
Engineering › Fuel Oil Service System
Issued 9 April 2002
Resolved
Indicate direction of operation for fuel cutoff valves LEGACY COMPONENT DESC: Valve
Construction/Loadline
Issued 16 March 2001
Resolved
REPAIR HULL DAMAGE IAW APPROVED REPAIR PROPOSAL
Construction/Loadline
Issued 16 March 2001
Resolved
PROVIDE REPAIR PROPOSAL FOR HULL DAMAGE
Electrical
Issued 2 March 2001
Resolved
HARD WIRE MSD PUMP
Construction/Loadline
Issued 2 March 2001
Resolved
SEAL CABLE PENETRATIONS IN AFT BULKHEAD OF THE FOREPEAK.
Electrical
Issued 2 March 2001
Resolved
REPAIR COVER ON PORT FLOODLIGHT
Electrical
Issued 2 March 2001
Resolved
DOUBLE CLAMP ALL HOSES IN THE ER
Construction/Loadline
Issued 2 March 2001
Resolved
SEAL THROUGH BULKHEAD CABLE PENETRATION
Electrical
Issued 2 March 2001
Resolved
SECURE BATTERY CHARGER TO THE SATISFACTION OF A CG INSPECTOR.
Documentation
Issued 2 March 2001
Resolved
1ST MATE AWAITING LIC RENEWAL WILL PROVIDE DOCUMENTATION.
Lifesaving
Issued 15 April 1999
Resolved
Update emergency station bill to reflect F.F.F. system in engine room & crews and masters duties.
Lifesaving
Issued 15 April 1999
Resolved
Renew 2 life jackets IAW 46 CFR 180.25 (Cork Style).
Engineering
Issued 15 April 1999
Resolved
Label fuel oil remote shut down valves IAW 46 CFR 182.455._x001C_
Engineering
Issued 15 April 1999
Resolved
Install mechanical ventilation closers for main space (engine room) to the satisfaction of the cognizant OCMI.
Lifesaving
Issued 15 April 1999
Resolved
Conduct and log drills as per 46CFR 185.420/.520/.524.
Documentation
Issued 15 April 1999
Resolved
Maintain official log book. (Supplied new small passenger log book.)
Lifesaving
Issued 15 April 1999
Resolved
Test and log test of EPIRB IAW 46 CFR 185.728._x001C_
Construction/Loadline
Issued 5 February 1997
Resolved
INVESTIGATE AND PROVIDE PROPOSAL OF REPAIRS TO SOFT DECK AT PORT SIDE MAIN DECK IN WAY OF ENGINEROOM
Engineering
Issued 5 February 1997
Resolved
INSTALL FIRE SHIELDING ON EMERGENCY P/S FUEL TANK VALVES IN WAY OF ENGINEROOM. SHIELDING MUST COMPLETELY SURROUND VALVE.
Engineering
Issued 5 February 1997
Resolved
REPAIR AS NEW CRACKS IN ENGINE BED FOUNDATION IN WAY OF FWD PORT AND STBD REAR SIDE. TIGHTEN OR RENEW FASTENERS AS REQUIRED.
Electrical
Issued 28 January 1997
Resolved
REMOVE ALL UN-USED WIRING IN PILOTHOUSE
Lifesaving
Issued 28 January 1997
Resolved
RE-STENCIL VESSELS NAME ON EPIRB
Electrical
Issued 28 January 1997
Resolved
REMOVE QUICK DISCONNECTS "GATOR CLIPS" FROM BATTERY CHARGER AND HARD WIRE
Lifesaving
Issued 28 January 1997
Resolved
COMPLY WITH THE REQUIREMENTS LISTED IN CG MEMO DATED 16 AUG 96 AS APPLICABLE. SEE ATTACHED MEMO.
Construction/Loadline
Issued 9 December 1994
Resolved
REPLACE BUTT BLOCKS IN LAZARETTE IN WAY OF PORT TRANSOM.
Construction/Loadline
Issued 9 December 1994
Resolved
RENEW AND TREAT PORT/STARBOARD STRINGERS IN WAY OF MAIN ENGINEROOM BEHIND FUEL TANKS.
Construction/Loadline
Issued 9 December 1994
Resolved
RENEW PLYWOOD FACE ON PORT DECK BEAM IN WAY OF MAIN ENGINE ROOM.
Construction/Loadline
Issued 9 December 1994
Resolved
RECAULK SMALL 4 - 6 INCH LEAK AT GRABARD SEAM IN WAY OF MIDSHIP.
Navigation
Issued 26 January 1990
Resolved
PROVIDE THREE(3) BLACK BALL DAY SHAPES.
Unknown
Issued 26 January 1990
Resolved
PROVIDE CURRENT PUBLICATIONS OF THE LIGHT LISTS, TIDE CURRENT TABLES AND PACIFIC COAST.
Lifesaving
Issued 26 January 1990
Resolved
REPLACE RING BUOY LINES WITH A 3/8", 60 FEET LONG LINE.
Lifesaving
Issued 26 January 1990
Resolved
REPAIR/REPLACE INOPERABLE WATER LIGHT FOR ONE(1) LIFE FLOAT.
Documentation
Issued 10 June 1987
Resolved
PROVIDE UP TO DATE COAST PILOT AND TIDAL CURRENT TABLES.
Lifesaving
Issued 10 June 1987
Resolved
RIG LIFE FLOATS FOR FLOAT FREE OPERATION
Lifesaving
Issued 10 June 1987
Resolved
PROVIDE 9 ADULT AND 2 CHILDS LIGHTED PFD.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.