EDEN

EDEN is a 1995 towing vessel. The Coast Guard has recorded 43 inspections since 1995, most recently in April 2026, along with 57 deficiencies — 1 with no resolution recorded —, 1 operational control and 2 casualty investigations between 2007 and 2014.

Records from 1995 to 2026. Most recent: inspection, 8 April 2026.

Built
1995
Last inspected
8 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WCV2999
428460
Flag
UNITED STATES
Maury page id
psix-428460

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded4
Years with a record 28 calendar years (1995–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)47.0 ft × 16.0 ft × 4.2 ft
Registered tonnagegross 21 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBIG RIVER SHIPBUILDERS · VICKSBURG MS, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portVICKSBURG, MS
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LELAND SPEAKES Towing Vessel · MISLE 94991 · 30 June 2014 · activity 4907129

Inspection history · 43

8 April 2026 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8343619
28 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8146008
24 July 2024 Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7989354
4 March 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7872326
7 December 2022 Initial Certification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7604545
26 April 2022 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7438621
3 February 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7138866
18 June 2020 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6987867
8 May 2019 Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6679702
26 March 2019 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6649278
30 October 2017 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6297547
18 October 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6290698
9 February 2017 DAPI Audit · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6087265
7 February 2017 Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6084240
26 May 2016 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5888724
25 July 2014 Drydock Exam · Damage Survey · COI Inspection · Examination of Repairs · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4933320
30 June 2014 Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4907129
3 December 2013 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4763074
13 November 2013 MTSA Verification · Examination of Repairs · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4759293
15 October 2013 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4736892
5 April 2012 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4280624
29 November 2011 Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4200014
1 June 2011 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4039288
3 March 2011 Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3957248
27 January 2011 Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3934804
15 December 2009 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3651231
18 August 2008 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3354192
1 May 2008 Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3205473
30 October 2007 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3089867
17 August 2006 COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2762859
30 November 2005 Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2552095
23 November 2004 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2256189
14 November 2003 Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1949411
26 November 2002 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1713255
27 August 2001 COI Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1379584
17 October 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1057225
11 September 2000 Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1399443
27 December 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 665457
10 December 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1455798
2 September 1998 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413402
14 October 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425976
21 October 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411366
8 September 1995 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358904

Deficiency record · 57

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 April 2026 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Stbd engine has excessive exhaust leaking through the valve head through emission port. Identify cause of the excessive exhaust, fix and provide objective evidence to the CG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 21 April 2026
Resolution: Alarm tests were tested by a certified John Deere Mechanic. Analysis showed no deficiencies on the engines components or operations.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 April 2026 Resolved
Each towing vessel must perform the tests in Table 143.245(b). There is no record of any of the tests in the table. Complete all of the tests and record IAW 143.245(b). Test alarm set points and provide objective evience to the CG.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2026
Resolution: Alarm tests were tested by a certified John Deere Mechanic. Analysis showed no deficiencies on the engines components or operations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Observed a cracked weld on the port rudder post steering bracket. repair weld and to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 May 2025
Resolution: Conducted satisfactory inspection of the weld repair and test of the steering system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Observed excessive play in steering linkage components, remove and inspect steering pins, replace/repair to factory and to the satisfaction of the Marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 June 2025
Resolution: New pins and bushings installed on the steering system and tested, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 4 March 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. One of three batteries is operational, unable to operate radar without running up main engines. Replace in-operational batteries and operationally test radar prior to commercial use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2024
Resolved 7 March 2024
Resolution: Vessel replaced dead batteries and showed an MI radar work on battery vice running up main engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 March 2024 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended back flooding through bilge piping. Unable to test Bilge pump due to not having equipment on board. Test bilge system in the presence of a Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2024
Resolved 20 March 2024
Resolution: Satisfactory test of the bilge pump system conducted in the presence of the Marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 4 March 2024 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Three chains missing from rail on starboard side, replace chain.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2024
Resolved 5 March 2024
Resolution: Vessel rep. provided objective evidence to correct deficiency
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 4 March 2024 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. This is not meant to restrict access to towing equipment such as winches, drums, towing gear or steering compartment equipment necessary for the operation of the vessel. The guard on port main engine inboard side is broken, replace.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2024
Resolved 20 March 2024
Resolution: Objective evidence of the replaced engine guard recieved, all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 March 2024 Resolved
Essential systems or equipment must be regularly tested and examined. Unable to verify Main and auxiliary engine set points have been tested twice in the last five years.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2024
Resolved 5 March 2024
Resolution: provided letter attesting that alarms were tested. See documents.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 4 March 2024 Resolved
The marine employer shall ensure that all individuals engaged or employed on board a vessel are fully indoctrinated in the requirements of this subpart, and that appropriate vessel personnel are trained as necessary in the practical applications of these requirements. Vessel and Master were not enrolled in DAPI program, enroll the vessel and Master in a drug and alcohol program and show evidence to a Marine Inspector.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 March 2024
Resolved 4 March 2024
Resolution: Ship provided objective evidence to correct deficiency
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 4 March 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 March 2024
Resolved 4 March 2024
Resolution: vessel rep. provided evidence to correct def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 December 2022 No resolution recorded
The following systems must be equipped with gauges at the machinery location: aux generator RPM. The vessel's generator does not have a gauge for the engine RPM.
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 April 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Perishables in first-aid kit were expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2022
Resolved 27 April 2022
Resolution: The first aid kit was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 April 2022 Resolved
All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons per minute. This pump shall be equipped with suction and discharge hose suitable for use in fire fighting.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2022
Resolved 27 April 2022
Resolution: An appropriate portable dewatering pump was placed onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2022 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. The hydraulic lines going to the steering ram are heavily corroded. Prove the hydraulic line are suitable for service and route.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 27 April 2022
Resolution: The steering line was replaced with a flexable hose. SAT.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 26 April 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length a visual and audible alarm must be provided at the operating station to indicate a high water level. The visual alarms at the operating station were in op.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2022
Resolved 27 April 2022
Resolution: The light bulb was changed and operational test was SAT.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 30 October 2017 Resolved
Make repairs to hand rail post and life lines (chains) prior to the carriage of passengers. Post can remain removable but must fit securely in their housing, life lines (chain) must be attached in such a manner that someone on board were to grab the chain it would adequately support and potentially prevent a person from falling overboard. Repairs should made to original design.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2018
Resolved 26 March 2019
Engineering › Bilge Water Management System › Piping
Issued 18 October 2017 Resolved
Steering void bilge suction piping neck is wasted, crop and renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 15 November 2017
Resolution: Bilge suction piping replaced.
Engineering › Steering Gear System › Linkage
Issued 18 October 2017 Resolved
Jockey bar pin bearings/bushings both port and stbd are worn and need replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 15 November 2017
Resolution: Bearings replaced, operational test conducted. test SAT
Lifesaving › Hand Flares › Expired
Issued 18 October 2017 Resolved
Supply proper in date flares.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 15 November 2017
Resolution: Vessel procured new in date flares.
Lifesaving › Hand Flares › Storage
Issued 18 October 2017 Resolved
Properly label flare container.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 26 March 2019
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 27 May 2016 Resolved
Continuous tripping of several circuit breakers on pilothouse console panel.
Action required: 705 - Other - as specified
Resolved 2 June 2016
Resolution: Repaired breaker panel
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 May 2016 Resolved
Wiring under console is in disarray and there is a burnt smell emanating from the console, indicatiing faulty circuits.
Action required: 705 - Other - as specified
Resolved 2 June 2016
Resolution: Repaired wiring
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 27 May 2016 Resolved
Inspection is overdue for all portable firefighting equipment.
Action required: 705 - Other - as specified
Resolved 2 June 2016
Resolution: Inspection completed
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 May 2016 Resolved
First aid kit missing several items.
Action required: 705 - Other - as specified
Resolved 2 June 2016
Resolution: Replaced entire first aid kit
Communications › Visual Communication › Warning Sign (radio room)
Issued 27 May 2016 Resolved
Emergency procedure not posted in pilothouse.
Action required: 705 - Other - as specified
Resolved 2 June 2016
Resolution: Posted procedures
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 May 2016 Resolved
Improper mounting bracket
Action required: 705 - Other - as specified
Resolved 2 June 2016
Resolution: Removed fire extinguisher to a safer location.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 27 May 2016 Resolved
Missing emergency broadcast placard
Action required: 705 - Other - as specified
Resolved 2 June 2016
Resolution: Posted emergency broadcast instructions
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 27 May 2016 Resolved
Install proper overcurrent protection on searchlight
Action required: 705 - Other - as specified
Resolved 2 June 2016
Resolution: Installed proper fuses
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 May 2016 Resolved
Loose guards over engine pulleys
Action required: 705 - Other - as specified
Resolved 2 June 2016
Resolution: Repaired guards
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 27 May 2016 Resolved
No certificate
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 2 June 2016
Resolution: FCC Safety certificate issued by FCC tech
Electrical › Lighting (service) › Lighting Fixture
Issued 27 May 2016 Resolved
Searchlight controls in-op
Action required: 705 - Other - as specified
Resolved 2 June 2016
Resolution: Replaced entire searchlight assembly
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 27 May 2016 Resolved
Fuel tank vent missing 30 x 30 mesh
Action required: 705 - Other - as specified
Resolved 7 June 2016
Resolution: Installed flame screens.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 May 2016 Resolved
Vessel is overdue for an Annual Exam. Vessel was due for an annual exam NLT 09 APR 2015 and is over a year overdue.
Action required: 705 - Other - as specified
Resolved 2 June 2016
Resolution: Completed Annual Inspection
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 November 2013 Resolved
Electrical junction box cover missing. Box is above stbd side engine of engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2013
Resolved 13 November 2013
Resolution: Cover placed on junction box.
Fire Fighting › Fire Hoses › Material
Issued 13 November 2013 Resolved
Fire hose was of garden type and did not meet regulations.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2013
Resolved 19 November 2013
Resolution: Fire hose of proper material placed in service.
Fire Fighting › Fire Pumps › Impeller
Issued 13 November 2013 Resolved
Fire pump inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2013
Resolved 19 November 2013
Resolution: Replaced impeller, fire pump displayed proper pressure discharge.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 October 2013 Resolved
Vessel is overdue for the required Annual Inspection. COI secured and submitted to MSD Vicksburg via mail.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2013
Resolved 13 November 2013
Resolution: COI exam completed. Temp COI issued.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2011 Resolved
Install metal supports not more than twent four (24) inches apart.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2011
Resolved 1 June 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 March 2011 Resolved
Replace retroreflective material on ring life bouys.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2011
Resolved 6 May 2011
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 March 2011 Resolved
Replace retroreflective material on life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2011
Resolved 6 May 2011
Lifesaving › Hand Flares › Marking
Issued 3 March 2011 Resolved
Mark containers with "DISTRESS SIGNALS".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2011
Resolved 1 June 2011
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 March 2011 Resolved
Mark valve with proper placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2011
Resolved 1 June 2011
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 3 March 2011 Resolved
Update Coast Guard light list with most current.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2011
Resolved 1 June 2011
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 3 March 2011 Resolved
Mount and/or post proper placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2011
Resolved 1 June 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 January 2011 Resolved
Vessel is passed due on an annual inspection. Inspection was due no later than 17NOV10.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2011
Resolved 5 May 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 January 2011 Resolved
Vessel's drydock date was 26OCT10. Company failed to meet requirements according to the COI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 February 2011
Resolved 3 March 2011
Construction/Loadline
Issued 27 August 2001 Resolved
RENEW/REPAIR BILGE ALARM LIGHT.
Condition: Unknown
Due 31 August 2001
Resolved 2 October 2001
Navigation
Issued 27 August 2001 Resolved
REPAIR PORT AND STARBOARD RUDDER TILLER ARM WHERE RUBBING ON TRANSOM.
Condition: Unknown
Due 27 September 2001
Resolved 2 October 2001
Documentation
Issued 27 August 2001 Resolved
PROVIDE ONBOARD ORIGINAL LICENCE FOR VESSEL MASTER
Condition: Unknown
Due 31 August 2001
Resolved 2 October 2001
Lifesaving
Issued 27 August 2001 Resolved
PROVIDE TWO MORE HANDHELD FLARES.
Condition: Unknown
Due 27 September 2001
Resolved 2 October 2001
Deck/Cargo
Issued 27 August 2001 Resolved
RENEW WASTED ANCHOR LINE.
Condition: Unknown
Due 27 September 2001
Resolved 2 October 2001
Electrical
Issued 27 August 2001 Resolved
PROPERLY REPAIR GENSET VOLTAGE REGULATOR.
Condition: Unknown
Due 27 September 2001
Resolved 2 October 2001
Electrical
Issued 27 August 2001 Resolved
PROVIDE COVER FOR TEMPORAY VOLTAGE REGUALTOR.
Condition: Unknown
Due 31 August 2001
Resolved 2 October 2001
Documentation
Issued 10 December 1999 Resolved
Present vessel for reinspection.
Condition: Unknown
Due 13 December 1999
Resolved 13 December 1999
Documentation
Issued 10 December 1999 Resolved
Renew documentation certificate.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Documentation
Issued 8 September 1995 Resolved
PROVIDE ONBOARD VESSEL A SMALL PASSENGER VESSEL STABILITY LETTER.
Condition: Unknown
Due 8 October 1995
Resolved 25 October 1995

Casualty record · 2

30 October 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3089867
30 June 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4907129
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.