Records from 1995 to 2010. Most recent: inspection, 10 March 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
10 March 2010
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3698731
2 March 2010
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3688645
17 March 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3434973
14 January 2009
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3393917
17 March 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3166195
10 December 2007
In-Service Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3112824
16 March 2006
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2602799
21 March 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2315099
16 November 2004
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2241807
25 March 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2034237
11 December 2002
Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1717697
19 March 2002
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1494943
23 April 2001
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1469680
16 August 2000
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1449373
22 March 2000
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1459585
5 August 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 775663
31 March 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1117758
12 May 1998
Hull Examination · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1125352
18 June 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 776459
30 April 1997
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1097360
8 July 1996
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1087045
13 March 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1078514
23 June 1995
Initial Certification · Deficiency Check · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 875475
Construction/Loadline › Hull › Bottom Plating
Issued 17 March 2009
Resolved
Repair the leak in the bottom hull plating, IWO the aft drive shaft.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2009
Resolved 19 March 2009
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 17 March 2009
Resolved
Replace the faded emergency broadcast placared.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2009
Resolved 19 March 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 March 2009
Resolved
Replace the outdated first aid items.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2009
Resolved 19 March 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 March 2008
Resolved
First aid kit not labled properly.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 24 March 2008
Resolution: Labled sat.
Fire Fighting › Ventilation Systems › Ducts
Issued 16 March 2006
Resolved
Prior to carrying passengers, prove proper operation of both ventilation louvers for engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 17 March 2006
Resolution: [name withheld] witnessed sat. test of louvers.
Engineering › Bilge Water Management System › Pump
Issued 21 March 2005
Resolved
Provide an operable portable bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2005
Resolved 24 March 2005
Resolution: [name withheld] witnessed satisfactory test of new portable bilge pump.
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 December 2002
Resolved
Provide two (2) additional adult life preservers. The vessel is restricted to 30 adults. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 19 March 2003
Construction/Loadline › Hull
Issued 11 December 2002
Resolved
Prior to carrying passengers, properly repair the leak on the starboard side aft of the forward wheel well. LEGACY COMPONENT DESC: Side Shell
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2003
Resolved 19 March 2003
Construction/Loadline › Markings
Issued 11 December 2002
Resolved
Properly label the loading mark on the rear of the hull. LEGACY COMPONENT DESC: Load Line Mark
Due 30 September 2003
Resolved 25 March 2004
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 19 March 2002
Resolved
Prove proper operation of side curcaitemergency release mechanisms for port and stbd sides.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2002
Resolved 26 March 2002
Engineering › Bilge Water Management System
Issued 19 March 2002
Resolved
Prove proper operation of bilge pumps, high water alarms and flammable vapor detection system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2002
Resolved 26 March 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 19 March 2002
Resolved
Provide satisfactory documentation of completion of annual servicing for portable and fixed fire extinguishers. LEGACY COMPONENT DESC: Service
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2002
Resolved 26 March 2002
Navigation
Issued 22 March 2000
Resolved
REPAIR BOW NAVIGATIONAL LIGHT.
Condition: Unknown
Due 1 April 2000
Resolved 18 April 2000
Construction/Loadline
Issued 22 March 2000
Resolved
PROVE PROPER OPERATION OF VESSEL'S BILGE PUMP PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 1 April 2000
Resolved 18 April 2000
Lifesaving
Issued 22 March 2000
Resolved
REPLACE BATTERY FOR WATERLIGHT FOR AFT RING BUOY.
Condition: Unknown
Due 1 April 2000
Resolved 18 April 2000
Construction/Loadline
Issued 12 May 1998
Resolved
PROVE PROPER OPERATION OF MECHANICAL BILGE PUMP PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Construction/Loadline
Issued 13 March 1996
Resolved
CLEAN (SAND BLAST) AS DISCUSSED DURING HULL EXAM TO PORT SIDE MID-BODY FRAME BAYS JUST AHEAD OF AFT WHEEL WELL AND MAKE AVAILABLE FOR FURTHER INSPECTION._x001C_ _x001C_
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Construction/Loadline
Issued 13 March 1996
Resolved
INSERT HOLED AREA CROPPING TO GOOD STEEL AND RADIOUSING CONCERNS AS DISCUSSED THIS DATE DURING HULL EXAMINATION (HOLED AREA IS ON STARBOARD SIDE DRIVE SHAFT TUNNEL)._x001C_ _x001C_
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Construction/Loadline
Issued 23 June 1995
Resolved
MAKE PERMANENT REPAIRS TO HOLE IN STERN IN WAY OF PORT WHEEL WELL TOP STRINGER AND HOLE VICINITY OF AFT DRIVE SHAFT. ALL REPAIRS ARE TO BE TO THE SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR AND PRIOR TO PLACING VESSEL IN SERVICE.
Condition: Unknown
Due 23 July 1995
Resolved 2 August 1995