RENDEZVOUS

RENDEZVOUS is a 1943 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 1985, most recently in May 2012, along with 83 deficiencies and 1 casualty investigation in 2008.

Records from 1985 to 2012. Most recent: inspection, 11 May 2012.

Built
1943
Last inspected
11 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE3494
Flag
UNITED STATES
366963550, 367339870 (licence lapsed)
Maury page id
psix-42855

Inspections, by type

…with no type recorded6
Years with a record 18 calendar years (1985–2012)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it9 - Regulatory (Subpart C or D), Net Ton
13 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE3494MMSI 367339870 · expired · compulsorily equipped · granted 27 February 2008, cancelled 5 May 2018
WDB8747MMSI 366963550 · cancelled · compulsorily equipped · granted 10 July 2004, cancelled 30 June 2010
WCZ4835MMSI not assigned · expired · compulsorily equipped · granted 3 September 1999, cancelled 7 November 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TAYLOR MIA Freight Ship · MISLE 289154 · 16 July 2008 · activity 3468546

Inspection history · 37

11 May 2012 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4318420
16 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4116572
20 July 2011 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4089074
2 July 2009 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3521289
16 July 2008 Construction Oversight · Damage Survey
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3270911
16 July 2008 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3468546
26 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3254486
17 June 2008 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3240607
16 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3208694
30 October 2007 Construction Oversight · Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3234054
29 August 2006 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2762409
15 June 2006 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2680414
20 September 2005 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2497985
5 July 2004 COI Inspection · Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2122271
13 September 2000 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1437767
5 October 1999 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1193932
21 June 1999 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 879741
21 September 1995 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 876405
27 October 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 861189
7 September 1994 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1174091
15 August 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 866685
18 July 1994 Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 870521
22 June 1994 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1137450
14 June 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 104477
18 August 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 844286
9 August 1993 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 845351
29 January 1993 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 829844
14 September 1992 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1263208
10 August 1992 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 954853
12 June 1992 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 960117
15 August 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 941319
18 July 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1044929
13 November 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1220793
2 November 1987 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1328462
16 March 1987 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1013949
17 October 1985 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1298634
6 June 1985 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 982982

Deficiency record · 83

Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 16 August 2011 Resolved
Provide 30x30 mesh flame screen for fuel tank vent.
Action required: 705 - Other - as specified
Due 16 September 2011
Resolved 7 October 2011
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 2 July 2009 Resolved
PROVIDE UPDATED NAVIGATION PUBLICATIONS.
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 6 August 2009
Resolution: Attended vessel. Publications up to date.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 2 July 2009 Resolved
PROVIDE AND POST AN EAP 1-800 NUMBER.
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 6 August 2009
Resolution: Attended vessel. EAP number is posted.
Lifesaving › Hand Flares › Quantity
Issued 2 July 2009 Resolved
PROVIDE 3 ADDITIONAL DAY AND NIGHT FLARES.
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 6 August 2009
Resolution: Attended vessel. All required flares on board and not expired.
Documentation › Markings/Placards › Official Number (US)
Issued 2 July 2009 Resolved
AFFIX THE VESSEL DOCUMENTATION NUMBER PERMANENTLY TO A STRUCTURAL PART OF THE VESSEL.
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 6 August 2009
Resolution: Attended vessel. ON placard epoxied and screwed on deck deam in forward compartment.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 2 July 2009 Resolved
PROVIDE A SUITABLE LADDER TO ACCESS THE PRIMARY LIFESAVING FLOATS.
Action required: 705 - Other - as specified
Due 7 September 2009
Resolved 15 September 2009
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 17 June 2008 Resolved
Vessel is certificated to carry 38 total people. Vessel has 35 adult PFD's on board. Vessel is limited to 35 persons on board until additional PFD's are provided for inspection.
Action required: 705 - Other - as specified
Resolved 19 June 2008
Resolution: Vessel provided aditional three PFD''s to bring total up to 38 and in complliance with COI.
Engineering › Bilge Water Management System › Interface Detector
Issued 17 June 2008 Resolved
Light on bilge high level alarm for compartment #3 is not operating. Repair or replace and provide proof of operation.
Action required: 705 - Other - as specified
Resolved 26 June 2008
Resolution: Lighrt was repaired and is working properly
Engineering › Bilge Water Management System › Interface Detector
Issued 17 June 2008 Resolved
Provide labels for all bilge alarm interfaces in the piolt house.
Action required: 705 - Other - as specified
Resolved 26 June 2008
Resolution: All bilge high level alarms are labeled
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 June 2008 Resolved
Provide proper label for remote fuel shutoff.
Action required: 705 - Other - as specified
Resolved 26 June 2008
Resolution: Fuel shutoff is labeled
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 17 June 2008 Resolved
Provide label for pull handle to energize system.
Action required: 705 - Other - as specified
Resolved 26 June 2008
Resolution: Labeled pull handel for the fixed system
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 17 June 2008 Resolved
Vessel is not equiped with a means of emergency steering. Provide a means of emergency steering for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2008
Resolution: Vessel provided a means of emergency steering. A tiller has been fitted to the steering gear in the stern of the vessel.
Engineering › Bilge Water Management System › Pump
Issued 17 June 2008 Resolved
Provide portable 5 gpm bilge pump.
Action required: 705 - Other - as specified
Resolved 26 June 2008
Resolution: Vessel provided portable bilge pump
Communications › Radio Communications › EPIRB
Issued 29 August 2006 Resolved
Provide current hydrostatic release unit for EPIRB. Vessel restricted to 3 miles when carrying pssengers until requirement is cleared.
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 7 September 2006
Resolution: O/O notified office that HRU has been renewed.
Communications › Radio Communications › EPIRB
Issued 29 August 2006 Resolved
Provide valid registration of EPIRB. Vessel restricted to 3 miles when carrying pssengers until requirement is cleared.
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 7 September 2006
Resolution: O/O faxed copy of EPIRB registration.
Fire Fighting › Fire Bucket › Quantity
Issued 29 August 2006 Resolved
Provide 1 additional fire bucket.
Action required: 705 - Other - as specified
Due 12 September 2006
Resolved 7 September 2006
Resolution: Fire bucket provided.
Lifesaving › Lifefloat › Lifeline
Issued 29 August 2006 Resolved
Replace Lifefloat and BA waterlight lanyards with 18' UV resistant line.
Action required: 705 - Other - as specified
Due 12 September 2006
Resolved 7 September 2006
Resolution: O/O notified office that lines have been renewed (proper length/type).
Engineering › Lubricating Oil Storage/Transfer System › Filter/Strainer
Issued 29 August 2006 Resolved
Properly mount oil filter.
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 7 September 2006
Resolution: O/O advised that oil filter has been properly mounted.
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 August 2006 Resolved
Install double hose clamps on raw water intake cooling hoses.
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 7 September 2006
Resolution: O/O notified office that double hose clamps have been installed.
Construction/Loadline › Hull › Stringer
Issued 15 June 2006 Resolved
COMPT #2: RENEW #6 TRANVERSE DECK BEAM. OUTER ENDS IN WAY OF DECK SHELF IS ROTTED.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 8 May 2008
Resolution: Deck shelf repaired in several sections. Other areas to be repaired at end of season per O/O proposal.
Construction/Loadline › Structures › Deck Plating
Issued 15 June 2006 Resolved
COMPT #2: RENEW WOOD DECK INWAY OF SAMPSOM POST AND UNDER DECK FRAMING THAT SUPPORTS SAMPSON POST.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 8 May 2008
Resolution: Area has been repaired.
Construction/Loadline › Hull › Stringer
Issued 15 June 2006 Resolved
COMPT #2: REMOVE ROTTED SPACES BETWEEN TRANSVERSE DECK STRINGERS IN WAY OF DECK SHELF.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 8 May 2008
Resolution: Repairs made. Good wood scarfed in at 12:1 ratio.
Construction/Loadline › Structures › Deck Plating
Issued 15 June 2006 Resolved
DEVELOPE A COVERING BOARD RENEWAL PROGRAM AROUND PERIMETER OF MAIN DECK. FIRST AREA TO BE REPLACED SHALL BE STARBOARD SIDE STARTING FROM STEM TO AFT QUARTER DURING 2008 HULL EXAM.
Due 31 July 2008
Resolved 8 May 2008
Resolution: Repaired. Nearly all deck is renewed.
Construction/Loadline › Structures › Deck Plating
Issued 15 June 2006 Resolved
COMPT #2: RENEW WOOD AROUND HATCH OPENING.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 8 May 2008
Resolution: Repaired. Old wood cropped and renewed.
Construction/Loadline › Structures › Deck Plating
Issued 15 June 2006 Resolved
COMPT #3: REPAIR DECK PLANKS IN WAY OF #8 DECK BEAM.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 8 May 2008
Resolution: Deck planks repaired.
Construction/Loadline › Structures › Deck Plating
Issued 15 June 2006 Resolved
DEVELOPE A WOOD DECK RENEWAL PLAN CONCENTRATING ON WORST AREAS DURING 2008 HULL EXAM.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 8 May 2008
Resolution: Completed during 2007-2008 drydock period.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 June 2006 Resolved
COMPT #1: MAKE REPAIRS TO ROTTED WOOD IN COLLISION BULKHEAD.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 8 May 2008
Resolution: Collision bulkhead repairs made.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 20 September 2005 Resolved
TIGHTEN SHAFT PACKING TO MINIMIZE LEAKING
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 4 November 2005
Resolution: SHAFT PACKING TIGHTENED, LEAKING STOPPED.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 20 September 2005 Resolved
MAKE VENTILATION CLOSURES OPERABLE
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 4 November 2005
Resolution: VENTILATION CLOSURES OPERABLE
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 20 July 2004 Resolved
Assure proper operation of MSD
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2004
Resolved 20 August 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 July 2004 Resolved
Properly service fire extinguishers, hydrotesting as needed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2004
Resolved 20 July 2004
Lifesaving › Buoyant Apparatus › Serviceable
Issued 20 July 2004 Resolved
Repair or replace boyant apparatus
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2004
Resolved 20 August 2004
Lifesaving › Lifefloat › Float Free
Issued 20 July 2004 Resolved
Install retainer posts for life float
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2004
Resolved 20 August 2004
Construction/Loadline › Structures › Ventilators
Issued 20 July 2004 Resolved
Have proper plugs readily available for all vents to below deck spaces.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2004
Resolved 20 August 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 July 2004 Resolved
Secure forward deck rail to meet specifications of 46CFR177.900.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2004
Resolved 20 August 2004
Communications › Alarms/Indicators › Propeller Speed Indicator
Issued 20 July 2004 Resolved
Properly mount bridge controls and gauges and assure proper operation.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2004
Resolved 20 August 2004
Electrical
Issued 13 September 2000 Resolved
REMOVE ALL DEAD-END WIRING IN THE ENGINE ROOM.
Condition: Unknown
Due 22 September 2000
Resolved 28 September 2000
Engineering
Issued 13 September 2000 Resolved
INSTALL A PROPER FLEX HOSE AND CONNECTIONS ON THE RAW WATER DISCHARGE LINE,STBD SIDE MDE.
Condition: Unknown
Due 22 September 2000
Resolved 28 September 2000
Construction/Loadline
Issued 13 September 2000 Resolved
MAKE TEMPORARY REPAIRS TO NYCMI IDENTS NY01 THROUGH NY08.
Condition: Unknown
Due 22 September 2000
Resolved 28 September 2000
Construction/Loadline
Issued 13 September 2000 Resolved
MAKE ALL SUBDIVISION BULKHEAD PENETRATIONS WATERTIGHT, IWO WIRING AND PIPING PENETRATIONS.
Condition: Unknown
Due 22 September 2000
Resolved 28 September 2000
Lifesaving
Issued 13 September 2000 Resolved
REPLACE RETRO-REFLECTIVE TAPE ON 6 PFD'S AS INDICATED; VESSEL LIMITED TO 43PASSENGERS UNTIL CORRECTED.
Condition: Unknown
Due 22 September 2000
Resolved 3 October 2000
Construction/Loadline › Hull › Transverse Frame
Issued 13 September 2000 Resolved
COMPT #1: C/R SIDE SHELL FRAME #6 FROM BOW, IWO BILGE AND AFT BLKHD.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2006
Resolved 20 July 2006
Construction/Loadline › Hull › Girder
Issued 13 September 2000 Resolved
COMPT #2: C/R TO GOOD WOOD, UNDER DECK CROSS BEAMS #1,2,5 & 6. TEMP REPAIRSMADE. PERMANENT REPAIRS SHALL BE MADE BY 01MAR01.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2006
Resolved 20 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2000 Resolved
COMPT #2: C/R TO GOOD WOOD, COWLING AROUND SAMPSON POST.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2006
Construction/Loadline › Hull › Bottom Plating
Issued 13 September 2000 Resolved
COMPT #2: C/R UNDER DECK SPACERS, ON THE OUT BOARD SIDES, BETWEEN THE UNDERDECK CROSS BEAMS. TEMP REPAIRS MADE. PERMANENT REPAIRS SHALL BE MADE BY 01MAR01.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2000 Resolved
COMPT #2: C/R TO GOOD WOOD, DECK PLANKS 1 & 2, STBD SIDE AFT, OUTBOARD SIDE.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2000 Resolved
COMPT #2: C/R ROTTEN WOOD AROUND HATCH OPENING.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2000 Resolved
COMPT #3: C/R TO GOOD WOOD, UNDER DECK CROSS BEAM #8. TEMP REPAIRS MADE. PERMANENT REPAIRS SHALL BE MADE BY 01MAR01.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2000 Resolved
COMPT #3: C/R TO GOOD WOOD, PORT AND STBD OUTBOARD DECK PLANK #1, AND #3 STBD OUTBOARD DECK PLANK.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2006
Construction/Loadline
Issued 13 September 2000 Resolved
MAKE PERMANENT REPAIRS TO SKEG SUPPORT PLATE.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Construction/Loadline
Issued 13 September 2000 Resolved
MAKE PERMANENT REPAIRS TO SKEG THROUGH-BOLT.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Lifesaving
Issued 13 September 2000 Resolved
PROVIDE 2 PADDLES FOR EACH LIFEFLOAT.
Condition: Unknown
Due 22 September 2000
Resolved 28 September 2000
Construction/Loadline
Issued 13 September 2000 Resolved
LABLE THE BILGE HIGH LEVEL ALARMS ON THE BRIDGE.
Condition: Unknown
Due 22 September 2000
Resolved 28 September 2000
Lifesaving
Issued 13 September 2000 Resolved
REPLACE RETRO-REFLECTIVE TAPE ON RING BUOY.
Condition: Unknown
Due 22 September 2000
Resolved 28 September 2000
Engineering
Issued 13 September 2000 Resolved
ADJUST SHAFT PACKING, TO REDUCE THE RATE OF WATER FLOW TO A PRACTICAL RATE.
Condition: Unknown
Due 22 September 2000
Resolved 28 September 2000
Navigation
Issued 13 September 2000 Resolved
PROVIDE AN EMERGENCY TILLER ON BOARD THE VESSEL.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Construction/Loadline
Issued 13 September 2000 Resolved
PROVIDE A PORTABLE BILGE PUMP LONG ENOUGH TO REACH THE BOTTOM OF ALL COMPARTMENTS AND DISCHARGE OVERBOARD.
Condition: Unknown
Due 22 September 2000
Resolved 28 September 2000
Lifesaving
Issued 5 October 1999 Resolved
CONDUCT A FIRE AND MAN OVERBOARD DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR PRIOR TO PASSSENGER CARRYING SERVICE.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Construction/Loadline
Issued 27 October 1994 Resolved
REPLACE AS ORIGINAL DECK PLANKING AND ASSOCIATED UNDER DECK BEAMS IN WAY OFWATERTIGHT HATCH FOR VOID SPACE #3 WHERE ROTTEN. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Construction/Loadline
Issued 27 October 1994 Resolved
REPLACE AS ORIGINAL FRAME #5 STBD SIDE IN VOID SPACE #3 WHERE ROTTEN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Construction/Loadline
Issued 27 October 1994 Resolved
REMOVE AND REPLACE IN KIND TWENTY THREE BOTTOM PLANKS WHERE MARKED, HOLED AND ROTTEN._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Construction/Loadline
Issued 27 October 1994 Resolved
REPLACE AS ORIGINAL FRAMES 2 THRU 7 PORT AND STBD OF VOID SPACE #2 FROM THEBILGE STRINGER DOWN TO KEEL WHERE ROTTEN._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Construction/Loadline
Issued 27 October 1994 Resolved
PROVE PROPER WATERTIGHT OPERATION OF ALL WEATHERDECK HATCHES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Construction/Loadline
Issued 27 October 1994 Resolved
MAKE COLLISION BULKHEAD WATERTIGHT IN WAY OF KEEL TIMBER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Engineering
Issued 15 August 1994 Resolved
PROVIDE AND INSTALL NEW COUPLING ON RAW WATER PUMP FOR MAIN ENGINE COOLING.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Electrical
Issued 15 August 1994 Resolved
PROVE PROPER OPERATION OF VESSEL'S D.C. ALTERNATOR.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Construction/Loadline
Issued 15 August 1994 Resolved
PROVE WATERTIGHT INTEGRITY OF ALL THREE WATERTIGHT HATCHES.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Lifesaving
Issued 9 August 1993 Resolved
PROVIDE A COAST GUARD APPROVED WATERLIGHT FOR THE 10 MAN BUOYANT APPARATUS.UNTIL SUCH TIME, THE TOTAL NUMBER OF PERSONS ALLOWED IS REDUCED TO 40.
Condition: Unknown
Due 9 August 1993
Resolved 9 August 1993
Lifesaving
Issued 9 August 1993 Resolved
RESTENCIL BOTH BUOYANT APPARATUSES IN ACCORDANCE WITH 46 CFR 180.20-5.
Condition: Unknown
Due 9 August 1993
Resolved 9 August 1993
Construction/Loadline
Issued 9 August 1993 Resolved
PROVIDE RETAINING DEVICES FOR THE FORE PEAK, LAZARETTE AND MIDSHIPS STORAGECOMPARTMENT HATCHES.
Condition: Unknown
Due 9 August 1993
Resolved 9 August 1993
Lifesaving
Issued 9 August 1993 Resolved
PROVIDE AN ADDITIONAL 9 ADULT COAST GUARD APPROVED LIFE PRESERVERS. UNTIL SUCH TIME, THE TOTAL NUMBER OF PERSONS ALLOWED ABOARD IS REDUCED TO 42.
Condition: Unknown
Due 9 August 1993
Resolved 9 August 1993
Navigation
Issued 10 August 1992 Resolved
REMOUNT NAVIGATION LIGHTS IN ACCORDANCE WITH NAVIGATION RULES (RULES OF THEROAD).
Condition: Unknown
Due 10 August 1992
Resolved 10 August 1992
Lifesaving
Issued 10 August 1992 Resolved
REPLACE MISSING BUOYANT APPARATUS. UNTIL SUCH TIME AS A NEW BUOYANT APPARATUS IS PLACED ON BOARD TOTAL NUMBER OF PERSONS ALLOWED IS REDUCED TO 40 PERSONS.
Condition: Unknown
Due 10 August 1992
Resolved 10 August 1992
Construction/Loadline
Issued 17 October 1985 Resolved
ON THE PORT SIDE RENEW THE SECOND PLANK UP FROM THE GARBOARD STRAKE FROM THE BUTT JOINT 11FT AFT OF THE BOW TO THE NEXT BUTT JOINT 28FT AFT OF THE BOW.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Construction/Loadline
Issued 17 October 1985 Resolved
ON THE STBD SIDE RENEW THE GARBOARD STRAKE 8FT FWD OF THE STERN TO THE NEXTBUTT JOINT FWD.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Construction/Loadline
Issued 17 October 1985 Resolved
RENEW 2ND PLANK UP FROM KEEL FIN FROM A POINT 11.5FT FWD OF THE STEARN TO A POINT 22.5FT FWD OF THE STEARN.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Engineering
Issued 17 October 1985 Resolved
REPAIR CRACKS IN CUTLASS BEARING STRUT.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Construction/Loadline
Issued 17 October 1985 Resolved
RENEW ROTTED PORTIONS OF STERN FRAME ON THE PORT AND STBD SIDES.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Navigation
Issued 17 October 1985 Resolved
REMOVE EXCESS SLACK FROM STEERING GEAR.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Unknown
Issued 17 October 1985 Resolved
OPEN SKIN VALVES FOR EXAMINATION.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Construction/Loadline
Issued 17 October 1985 Resolved
RENEW ALL FRAMES IN HULL.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Construction/Loadline
Issued 17 October 1985 Resolved
RENEW GARBOARD STRAKE ON THE PORT SIDE FROM THE STEM TO A POINT 31.5FT AFT.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Construction/Loadline
Issued 17 October 1985 Resolved
ON THE PORT SIDE RENEW THE 5TH PLANK UP FROM THE GARBOARD STRAKE FOR A DISTANCE OF THREE FRAME LENGTHS ON EITHER SIDE OF THE ROTTED AREA LOCATED 8FT AFT OF THE STEM.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985

Casualty record · 1

16 July 2008Routine · role: Involved in a Marine Casualty · activity 3468546
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.