MAURY USCG vessel records Sign in
← All vessels

CHEYENNE II

CHEYENNE II is a 1964 freight ship. The Coast Guard has recorded 47 inspections since 1995, most recently in February 2007, along with 105 deficiencies and 17 operational controls.

Records from 1995 to 2007. Most recent: operational control imposed, 14 February 2007.

Built
1964
Last inspected
14 February 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6504137 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ZKU2072
428655
Flag
COOK ISLANDS
—
Maury page id
psix-428655

Inspections, by type

…with no type recorded34
Years with a record 11 calendar years (1995–2007)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it662 - Convention (Subpart B), Gross Ton
272 - Regulatory (Subpart C or D), Gross Ton
272 - Convention (Subpart B), Net Ton
178 - Regulatory (Subpart C or D), Net Ton
720 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

B.J. 61 Unclassified · MISLE 41495 · 28 May 1996 · activity 139960

Inspection history · 47

14 February 2007 Deficiency Check · PII Safety Exam · Ballast Water Examination · Loadline Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2871326
13 February 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2871889
10 February 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2870249
24 October 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2807018
22 October 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2805400
3 September 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2767286
21 February 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2588987
17 February 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2587484
1 February 2006 NPV Safety Exam · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2579817
25 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2572833
26 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2540829
22 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2499256
22 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2507854
21 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2497640
28 July 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2445038
8 July 2005 PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2419807
2 May 2005 PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2347365
4 January 2005 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2268651
12 March 2004 Type not recorded
No type recorded · USCGC CORMORANT (WPB 87313) · USCG Southeast District (CGD-SE) · Activity 2024574
30 January 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1997693
11 December 2003 Re-Inspection · Administrative Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1962246
12 August 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1873874
5 June 2003 Type not recorded
No type recorded · USCGC MANITOU (WPB 1302) · USCG Southeast District (CGD-SE) · Activity 1824553
4 June 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1809416
4 June 2003 Type not recorded
No type recorded · USCGC CORMORANT (WPB 87313) · USCG Southeast District (CGD-SE) · Activity 1866390
18 April 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1775949
9 April 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1771070
9 October 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1687174
24 September 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1679588
7 June 2002 Administrative Inspection · Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1627866
5 December 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 296070
2 November 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 295153
14 May 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 290111
18 February 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 189267
18 February 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 764305
4 June 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 428608
30 October 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 395897
20 August 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 495064
2 July 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 533746
28 May 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 139960
22 May 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 391512
21 May 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 22421
26 April 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 461471
12 March 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 540084
11 March 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 389690
8 February 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 387716
4 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 381332

Deficiency record · 105

Documentation › Certificates/Documents › International Load Line Certificate
Issued 14 February 2007 Resolved
Loadline Certificate does not have required annual survey endorsement. Certificate is invalid until survey is completed.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2007
Resolved 6 March 2007
Resolution: Master provided old copy of Loadline certificate to CG inspectors on initial exam. Current copy provided to CG inspectors during def check.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 14 February 2007 Resolved
Steering gear rudder angle indicator(rai) and rai on bridge is deviating 5-10 degrees on port side and 10-15 degrees on stbd side from when rudder is actually positioned.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2007
Resolved 2 March 2007
Resolution: Rudder angle indicator sensor repaired and survey report from flag attesting to proper repairs submitted to USCG.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 14 February 2007 Resolved
Emergency fire pump is not providing adequate water pressure due to the lack of suction from the suction hose in the motor.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2007
Resolved 2 March 2007
Resolution: Suction hose for emergency fire pump fitted with new valve, survey report from flag attesting to proper repairs submitted to USCG.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2006 Resolved
Replace battery cable for generator in engine room. Currently, two cables are spliced together to achieve required length.
Action required: 705 - Other - as specified
Due 8 February 2006
Resolved 2 September 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2006 Resolved
Electrical wiring for pyrometer on main engine is not properly spliced. All electrical wiring must be spliced in an approval electrical box.
Action required: 705 - Other - as specified
Due 8 February 2006
Resolved 2 September 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 1 February 2006 Resolved
Provide light covers for overhead lighting in engine room. Also, provide two guards for glass lighting bulbs in engine room overhead.
Action required: 705 - Other - as specified
Due 8 February 2006
Resolved 2 September 2006
Lifesaving › Launching Appliances › Davit
Issued 1 February 2006 Resolved
Rescue boat cradle is wasted and broken. Make repairs to rescue boat cradle.
Action required: 705 - Other - as specified
Due 8 February 2006
Resolved 2 September 2006
Construction/Loadline › Structures › Superstructure
Issued 8 July 2005 Resolved
Corroding bulkheads on bridge windows and superstructure. Due prior too departure from drydock to the satisfaction of IACS representative or flag state.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 July 2005
Resolution: Vessel''s agent sent fax from [name withheld] attesting to repairs on bridge windows and superstructure.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 8 July 2005 Resolved
Provide Safety Management Certificates: SMC and DOC prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2005
Personnel › Manning/Qualifications
Issued 11 December 2003 Resolved
Manned vessel in accordance with the Safe Manning Certificate. CCSSC 1.7 LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2003
Construction/Loadline › Structures
Issued 11 December 2003 Resolved
Repaired hole on starboard side superstructure outside of bridge. CCSSC 2.4.1 LEGACY COMPONENT DESC: Superstructure
Due 11 January 2004
Resolved 27 December 2003
Lifesaving › Rescue Boat
Issued 11 December 2003 Resolved
Repair or replace rescue boat motor inoperable. CCSSC 4.3.1 LEGACY COMPONENT DESC: Propulsion Engine
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2003
Operations/Management › Navigation Safety
Issued 11 December 2003 Resolved
Repair all items addressed by Marine Surveyor dated on 4th November 2003.
Condition: Improper/Lack of Maintenance
Due 11 January 2004
Resolved 27 December 2003
Engineering › Generator (propulsion-electric)
Issued 11 December 2003 Resolved
Emergency generator fuel shut off valve is inop. Repair to the satisfaction of the flag state rep prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2003
Engineering › Generator (propulsion-electric)
Issued 11 December 2003 Resolved
Fuel lines to both emergency generators are improper. Repair to the satisfaction of the flag state rep prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2003
Engineering › Generator (propulsion-electric)
Issued 11 December 2003 Resolved
Fuel line to main generator is improper. Repair to the satisfaction of the flag state rep prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2003
Engineering › Generator (propulsion-electric)
Issued 11 December 2003 Resolved
Mechanical ventilation in emergency generator is spliced. Make permanent repairs to wiring prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 11 December 2003 Resolved
Fuel day tank in engine room is leaking. Repair to the satisfaction of the flag state rep prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2003
Pollution Prevention/Response › Prevention Equipment
Issued 11 December 2003 Resolved
Septic tank top is leaking. Make permanent and proper repairs to septic tank. Complete gauging by flag state rep. Provide report to MSO Miami. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2003
Pollution Prevention/Response › Prevention Equipment
Issued 11 December 2003 Resolved
Prove proper operation of sewage system to the satisfaction of the flag state rep. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2003
Engineering › Generator (propulsion-electric)
Issued 11 December 2003 Resolved
Exhaust leak on main generator. Repair to the satisfaction of the flag state rep prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2003
Engineering › Generator (propulsion-electric)
Issued 11 December 2003 Resolved
Leak on expansion/cooling tank to main generator. Repair to the satisfaction of the flag state rep prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 11 December 2003 Resolved
Replace gas line hose from tank to piping with proper material. Repair to the satisfaction of the flag state rep prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2003
Operations/Management › Drills/Instruction
Issued 9 April 2003 Resolved
Complete full CG annaul exam includeing proper crew familiarization drills to attending USCG Marine Inspector prior to departing the Port of Miami.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Documentation › Certificates/Documents
Issued 9 April 2003 Resolved
Provide all documentation required for vessel to the attending USCG Marine Inspector prior to departing the Port of Miami.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Personnel › Manning/Qualifications
Issued 9 April 2003 Resolved
Provide licenses and seafarers paper for the crew sailing with the vessel to the attending USCG Marine Inspector Prior to departing the Port of Miami. Two Licensed Engineers will be required.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Construction/Loadline › Hull
Issued 9 April 2003 Resolved
Improper repairs on hull and deck. Make permanent and proper repairs to the satisfaction of attending USCG Marine Inspector prior to departing. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2003
Resolution: Previous weld was crop out and replace with a certified weld.
Construction/Loadline › Hull
Issued 9 April 2003 Resolved
Hull appears to be very thin and wasted with heavy pitting. Have class conduct survey of freeboard and deck to include gauging of thin and heavily pitted areas. Provide copy of surveyors report to this office, prior to loading cargo or departing the port of Miami. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2003
Resolution: Surveyors report was submitted to the office. All areas under specs were repair using inserts.
Construction/Loadline › Structures
Issued 9 April 2003 Resolved
Forward cargo hold bulkhead, wasted and holed from US Customs drilling. Have surveyor gauge bulkhead and provide report. Make permanent and proper repairs to the satisfaction of attending USCG Marine Inspector prior to departing
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2003
Resolution: Gauging report was submitted to the office. All holes were repaired using welds.
Electrical › Electric Generation Source (emergency)
Issued 9 April 2003 Resolved
Emergency Generator in disrepair and appears to be inoperative. Make permanent and proper repairs, prove proper operation unload of the all required emergency equipment to the satisfaction of the attending USCG Marne Inspector. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Construction/Loadline › Structures
Issued 9 April 2003 Resolved
After Bulkhead in main engine space (Ballast Tank) is holed, wasted and appears very thin. Manhole covers and other fittings are wasted and leaking also. Have class conduct survey of bulkhead to include gauging of thin areas. Provide copy of surveyors report to this office, prior to loading cargo o LEGACY COMPONENT DESC: Superstructure
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2003
Resolution: Manhole covers were repaired using new gaskets. Holes from ballast tanks were repaired using new welds.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 April 2003 Resolved
Improper repairs and soft patches on main raw water piping including supply line for fire pump. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to load of cargo or departing the Port of Miami.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2003
Resolution: New piping was installed to replace soft-patches.
Electrical › Electric Generation Source (service)
Issued 9 April 2003 Resolved
Gauge to Fresh Water Tank leaking into battery box. Prove a cover to the battery box and make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to departing the Port of Miami. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Electrical › Electric Generation Source (service)
Issued 9 April 2003 Resolved
Improper and exposed wire on pump under fresh water tanks. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to departing the Port of Miami LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Fire Fighting › Combustible Materials
Issued 9 April 2003 Resolved
Cover missing on fuel tank. Gas free tank and secure, remove tank or put in back into proper working vapor tight condition. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to departing the Port of Miami.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 April 2003 Resolved
Exhaust piping and insulation for generator in wasted, falling apart and improper installed. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to departing the Port of Miami. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Engineering › Freshwater System (jacketwater cooling)
Issued 9 April 2003 Resolved
Fresh and raw water-cooling piping to the generator is wasted and leaking. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to departing the Port of Miami.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Electrical › Electrical Distribution System (service)
Issued 9 April 2003 Resolved
mproper and exposed wire between fresh water tanks. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to departing the Port of Miami. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Electrical › Electrical Distribution System (service)
Issued 9 April 2003 Resolved
Improper and exposed wiring throughout engineering spaces. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to departing the Port of Miami. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Fire Fighting › Combustible Materials
Issued 9 April 2003 Resolved
Generally poor house keeping and fire hazards throughout the engineering spaces and passageways. Remove fire and safety hazards from spaces to the satisfaction of the attending USCG Maine Inspector prior to departing the Port of Miami.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Electrical › Electrical Distribution System (service)
Issued 9 April 2003 Resolved
Improper and exposed wiring on control unit for main steering gear. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Construction/Loadline › Structures
Issued 9 April 2003 Resolved
Bulkhead in head wasted and holed. Piping leaking. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to departing the Port of Miami. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Electrical › Electrical Distribution System (service)
Issued 9 April 2003 Resolved
improper and hazardous wiring throughout accommodation spaces. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to departing the Port of Miami. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Electrical › Electric Generation Source (emergency)
Issued 9 October 2002 Resolved
Remove all dead end wiring to portside generator located in the Emergency Generator Room. LEGACY COMPONENT DESC: Dead end wiring
Due 1 November 2002
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Electrical › Electric Generation Source (service)
Issued 9 October 2002 Resolved
Remove or cap off open end piping leading from port generator hydraulic pump connection. LEGACY COMPONENT DESC: Circuit Breaker
Due 1 November 2002
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Electrical › Electric Generation Source (service)
Issued 9 October 2002 Resolved
Repair continuous leak on portside generator. Leak is located on exhaust heat exhanger.
Due 1 November 2002
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Fire Fighting › Fire Pumps
Issued 9 October 2002 Resolved
Permanently mount pressure gage on stbd fire pump. LEGACY COMPONENT DESC: Pressure
Due 1 November 2002
Resolved 23 April 2003
Resolution: Cleared on board by [name withheld] 23APR03.
Personnel › Certificates/Documents/Licenses
Issued 9 October 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2002
Resolution: Manager of vessel presented original letters for application to endorsement for all officers on board. Def cleared.
Lifesaving › Lifebuoys
Issued 7 June 2002 Resolved
Repair worn lines on lifebuoys around the entire vessel. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 15 - Rectify deficiencies by next port
Due 25 June 2002
Resolved 24 September 2002
Resolution: All lifebuoys are satisfactory.
Construction/Loadline
Issued 5 December 2001 Resolved
Provide proper loadline markings on hull in contrasting color IAW Loadline certificate and Loadline convetion upon completion of dry-dock.
Condition: Unknown
Due 31 January 2002
Resolved 25 June 2002
Resolution: Corrected.
Construction/Loadline
Issued 5 December 2001 Resolved
Make permanent repairs to hole in emergency escape hatch coaming from aft steering flat upon completion of dry-dock.
Condition: Unknown
Due 31 January 2002
Resolved 25 June 2002
Resolution: Corrected.
Construction/Loadline
Issued 5 December 2001 Resolved
Make permanent repair to hull portside lower hold approx. one and a half frames forward of aft bulkhead in lower cargo hold. Provide class report/survey upon completion of dry-dock.
Condition: Unknown
Due 31 January 2002
Resolved 25 June 2002
Resolution: Corrected.
Navigation
Issued 5 December 2001 Resolved
Provide current deviation table upon completion of dry-dock.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 31 January 2002
Resolved 5 December 2001
Lifesaving
Issued 5 December 2001 Resolved
Fit all lifejackets (lights/whistles/SOLAS retro-tape) IAW CCSSC 4.11.3 prior to departure.
Condition: Unknown
Due 6 December 2001
Resolved 25 June 2002
Resolution: Corrected.
Lifesaving
Issued 5 December 2001 Resolved
Remove oil from emergency generator room, engineroom bilge and cargo holds.provide receipt of removal/disposal to MSO prior to departure.
Condition: Unknown
Due 6 December 2001
Resolved 25 June 2002
Navigation
Issued 5 December 2001 Resolved
Make repairs to starboard navigation light. Corrected on the spot.
Condition: Unknown
Due 5 December 2001
Resolved 5 December 2001
Fire Fighting
Issued 5 December 2001 Resolved
Make temporary repairs to hole in fire main starboard side forward. Permanent repairs to be made at dry-dock.
Condition: Unknown
Due 6 December 2001
Resolved 25 June 2002
Engineering
Issued 5 December 2001 Resolved
Repair hole in stbd fuel oil containment prior to departure.
Condition: Unknown
Due 6 December 2001
Resolved 25 June 2002
Lifesaving
Issued 5 December 2001 Resolved
Complete fire and abandon ship drill with attending Coast Guard inspector prior to departure. Drill could not be conducted due to USCS being on board doing vessel search.
Condition: Unknown
Due 6 December 2001
Resolved 25 June 2002
Construction/Loadline
Issued 5 December 2001 Resolved
Make permanent repair to goosneck vent portside amidships labled BB#2 upon completion of dry-dock.
Condition: Unknown
Due 31 January 2002
Resolved 25 June 2002
Navigation › Piloting/Steering
Issued 5 December 2001 Resolved
Provide current deviation table. LEGACY COMPONENT DESC: Deviation Table/Graph
Action required: 15 - Rectify deficiencies by next port
Due 25 June 2002
Resolved 24 September 2002
Resolution: Updated table posted.
Deck/Cargo
Issued 2 November 2001 Resolved
Provide Dangerous Cargo Manifest and proof of crew HAZMAT training, or remove fuel from automobiles on board, as well as 55 gallon drums of sulfuric acid labeled as corrosive.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Deck/Cargo
Issued 2 November 2001 Resolved
Remove oily mixture in paint buckets leaking from deck crane and repair leaks on crane.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Electrical
Issued 14 May 2001 Resolved
Properly run electrical wire down portside on main deck.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Electrical
Issued 14 May 2001 Resolved
Have class attest to the proper installation of fwd generator.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Documentation
Issued 14 May 2001 Resolved
Provide crew licenses in according to safe manning document.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Unknown
Issued 14 May 2001 Resolved
Remove fuel from fwd peak.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Construction/Loadline
Issued 14 May 2001 Resolved
Properly weld patch in aft bulkhead of emergency generator.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Electrical
Issued 14 May 2001 Resolved
Properly secure starting battery for emergency generator.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Documentation
Issued 14 May 2001 Resolved
Provide all ship certificates and documents.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Fire Fighting
Issued 4 June 1999 Resolved
Prior to 13JUN99 write location of all fire extinguishers in SOLAS trainingmanual._x001C_ _x001C_
Condition: Unknown
Due 13 June 1999
Resolved 4 June 1999
Navigation
Issued 4 June 1999 Resolved
Prior to departure repair main steering assembly (electro-hydraulic system).
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Navigation
Issued 4 June 1999 Resolved
Prior to 13JUN99 immediately begin logging pre-arrival and departure tests.
Condition: Unknown
Due 13 June 1999
Resolved 4 June 1999
Accommodation/Occupational Safety
Issued 4 June 1999 Resolved
Prior to 13JUN99 immediately begin maintaining garbage log.
Condition: Unknown
Due 13 June 1999
Resolved 4 June 1999
Construction/Loadline
Issued 4 June 1999 Resolved
Prior to departure pump oily waste in bilges to shoreside facility.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Documentation
Issued 4 June 1999 Resolved
Prior to departure provide original license for Chief Mate.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Engineering
Issued 4 June 1999 Resolved
Prior to departure provide engine order telegraph as secondary means of communication.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Documentation
Issued 4 June 1999 Resolved
Prior to departure provide additional engineer officer for manned machineryspace or fixed detection system for unmanned machinery space.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Construction/Loadline
Issued 4 June 1999 Resolved
Prior to departure provide second power operated bilge pump.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Lifesaving
Issued 4 June 1999 Resolved
Prior to departure provide float-free arrangement for EPIRB.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Unknown
Issued 4 June 1999 Resolved
Prior to 13JUN99 provide letter from owner/operator to master explaining his responsibilities for familiarization training for new crewmembers.
Condition: Unknown
Due 13 June 1999
Resolved 4 June 1999
Lifesaving
Issued 4 June 1999 Resolved
Prior to departure post liferaft launching instructions for liferafts in creole.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Lifesaving
Issued 4 June 1999 Resolved
Prior to departure provide power winch motor to recover rescue boat.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Documentation
Issued 4 June 1999 Resolved
Prior to departure, provide a letter from the flag state accepting foreign licenses (Panama).
Condition: Unknown
Due 19 June 1999
Resolved 19 June 1999
Unknown
Issued 4 June 1999 Resolved
Prior to departure provide class surveyor report addressing all deficiencies.
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Documentation
Issued 4 June 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 June 1999
Resolved 19 June 1999
Lifesaving
Issued 30 October 1996 Resolved
PROVIDE 12 HAND HELD RED PARACHUTE FLARES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Construction/Loadline
Issued 30 October 1996 Resolved
PROVIDE RENEWED GASKETS FOR ALL TRUNK HATCHES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Construction/Loadline
Issued 30 October 1996 Resolved
RE-WELD/PERMANENTLY AFFIX LOADLINE MARK - SURVEYOR TO ADDRESS SUMMER/WINTER MARK IDENTICAL MEASUREMENTS ON LOADLINE CERTIFICATE, WHILE DIFFERENT IN MARKINGS.
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Documentation
Issued 30 October 1996 Resolved
PROVIDE MOST RECENT FLAG/CLASS ATTENDED DRYDOCK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Navigation
Issued 30 October 1996 Resolved
PROVIDE UPDATED LOCAL CHARTS (11466, 11468) AND INLAND NAVIGATION RULES (COLREGS)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Fire Fighting
Issued 22 May 1996 Resolved
All but one firefighting station was missing the hose and the nozzle.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Electrical
Issued 22 May 1996 Resolved
Main generator was ooc
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 22 May 1996 Resolved
Hydrostatic release was outdated.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 11 March 1996 Resolved
Vessel did not have enough serviceable pfds on board.
Condition: Unknown
Due 11 March 1996
Resolved 3 April 1996
Navigation
Issued 11 March 1996 Resolved
Vessel did not have updated charts on board.
Condition: Unknown
Due 11 March 1996
Resolved 3 April 1996
Deck/Cargo
Issued 11 March 1996 Resolved
None of the fuel vents were designed with proper containment.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Unknown
Issued 4 August 1995 Resolved
INSTALL FIRE DETECTION AND HIGH BILGE LEVEL ALARMS IAW BELIZE REGULATIONS.
Condition: Unknown
Due 5 September 1995
Resolved 11 September 1995
Unknown
Issued 4 August 1995 Resolved
PROVIDE EVIDENCE OF A SATISFACTORY TEST OF THE QUICK CLOSING FUEL STOPS_x001C_ PRIOR TO DEPARTURE.
Condition: Unknown
Due 5 September 1995
Resolved 11 September 1995
Unknown
Issued 4 August 1995 Resolved
PROVIDE A FLAG SURVEYORS REPORT ATTESTING TO THE CONDITION OF THE TANK TOP AND DOUBLE BOTTOM TANKS.
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Unknown
Issued 4 August 1995 Resolved
PROVIDE THIS OFFICE WITH A CREW LIST, MANNING CERTIFICATE, AND FLAG APPROVED LICENSES FOR EACH REQUIRED CREWMEMBER.
Condition: Unknown
Due 5 September 1995
Resolved 11 September 1995
Unknown
Issued 4 August 1995 Resolved
INSTALL A MARINE SANITATION DEVICE OF ADEQUATE CAPACITY FOR EACH INSTALLED TOILET.
Condition: Unknown
Due 5 September 1995
Resolved 11 September 1995
Unknown
Issued 4 August 1995 Resolved
PROVIDE EVIDENCE OF SERVICE FOR ALL PORTABLE FIRE EXTINGUISHERS ON BOARD.
Condition: Unknown
Due 5 September 1995
Resolved 11 September 1995
Unknown
Issued 4 August 1995 Resolved
PROVIDE UPDATED STABILITY INFORMATION ADDRESSING THE ADDITION OF THE DECK CRANE AND IT'S EFFECT ON THE RIGHTING MOMENT OF THE VESSEL.
Condition: Unknown
Due 5 September 1995
Resolved 11 September 1995
Unknown
Issued 4 August 1995 Resolved
UPON COMPLETION OF FLAG SURVEY AND PRIOR TO LOADING CARGO, REQUEST A CG RE-INSPECTION. HAVE COMPLETE CREW IN ATTENDENCE IAW MANNING CERTIFICATE.
Condition: Unknown
Due 5 September 1995
Resolved 11 September 1995

Ownership record