MAURY USCG vessel records Sign in
← All vessels

INDIAN

INDIAN is a 1953 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1985, most recently in January 2018, along with 123 deficiencies and 2 casualty investigations between 2016 and 2018.

Records from 1985 to 2018. Most recent: inspection, 12 January 2018.

Built
1953
Last inspected
12 January 2018
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCX4311
Flag
UNITED STATES
367352860 (licence lapsed)
Maury page id
psix-42871

Inspections, by type

…with no type recorded8
Years with a record 31 calendar years (1985–2018)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)39.6 ft × 11.6 ft × 5.3 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBRONZA M. PARKS · WINGATE, MD, UNITED STATES · built 1953
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLEWES, DE
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCX4311MMSI 367352860 · expired · compulsorily equipped · granted 30 April 2008, cancelled 15 September 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 64

12 January 2018 Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6337196
7 January 2018 Administrative Inspection · Internal Structural Exam · Damage Survey
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6334043
16 May 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6147170
6 July 2016 Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5956746
3 July 2016 Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5931979
10 May 2016 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5872268
16 March 2016 In-Service Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5873191
27 May 2014 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4870271
11 March 2014 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4813853
5 June 2012 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4333370
25 January 2011 Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3931550
30 December 2010 Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3917847
30 November 2010 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3901025
27 January 2010 Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3670589
7 April 2009 Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3447800
24 April 2008 Periodic Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3191413
7 March 2008 Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3160266
7 June 2007 Examination of Repairs
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2954389
6 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2953041
4 June 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2676156
17 April 2006 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2626444
28 April 2005 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2328215
1 April 2005 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2323977
7 February 2005 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2285735
27 April 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2053900
13 May 2003 Hull Examination · Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1848101
12 March 2001 Annual Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1387000
31 March 2000 COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1454780
5 May 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1410096
20 January 1999 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1400910
18 May 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 794477
5 May 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1364720
4 April 1997 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1109061
27 March 1997 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1094130
5 February 1997 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1449995
5 September 1996 Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1260374
20 May 1996 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 871163
12 April 1995 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1355181
27 March 1995 Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1353724
25 March 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 154849
31 May 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 864066
2 May 1994 Deficiency Check · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 857151
18 March 1994 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 854851
12 November 1993 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1136833
5 October 1993 Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 847568
12 May 1993 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1151138
24 April 1992 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1366728
13 April 1992 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1267778
21 March 1991 Deficiency Check · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 930674
18 March 1991 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1236608
7 June 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 914320
6 March 1990 Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 901606
26 April 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1037583
4 April 1989 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1040326
22 March 1988 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 996298
4 March 1988 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1304000
18 March 1987 Deficiency Check · Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1330821
5 March 1987 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1330819
26 March 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 997853
19 March 1986 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 997851
4 February 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1305372
4 September 1985 Credit Drydock · Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1297609
3 September 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296169
24 March 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 983745

Deficiency record · 123

Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 January 2018 Resolved
Based upon Worklist issued on this date due to vessel being flooded and partially submerged, vessel is restricted from carrying passengers until all Worklist items are corrected and verified by attending CG Marine Inspector. 46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2018
Resolved 27 February 2018
Resolution: Vessel scrapped
Stability › Watertight Integrity › General
Issued 16 May 2017 Resolved
Provide securing lanyards for watertight deck hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 30 May 2017
Resolution: Verified lanyards are now attached.
Lifesaving › Lifefloat › Markings
Issued 16 May 2017 Resolved
Mark lifefloat and paddles with the vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 30 May 2017
Resolution: Verified that the proper markings were applied.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 May 2016 Resolved
Prove proper main engine shut-down with the pre-engineered fixed gas fire extinguishing system. 46 CFR 181.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 13 May 2016
Resolution: Witnessed proper operation of engine shut-down and override.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 10 May 2016 Resolved
Prove proper installation/fit of engine compartment vent closures. 46 CFR 182.20-45
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 13 May 2016
Resolution: Verified new vent closures.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 May 2016 Resolved
Prove proper operation & installation of port navigation light. Vessel restricted to daylight operations until corrected. 46 CFR 176.25-40
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 13 May 2016
Resolution: Port light now operational and correctly installed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 May 2016 Resolved
Provide three approved type 1 adult PFD's. Total number of persons allowed reduced to 14. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 13 May 2016
Resolution: Provided.
Communications › Radio Communications › EPIRB
Issued 10 May 2016 Resolved
Provide and install valid hydrostatic release unit for EPIRB. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 1 June 2016
Resolution: New HRU is installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 May 2014 Resolved
Repair bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2014
Resolution: Bilge alarms test satifactorily..
Lifesaving › Lifefloat › Paddle
Issued 27 May 2014 Resolved
Provide life float paddles.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2014
Resolution: Life float paddles provided.
Fire Fighting › Fire Bucket › Availability
Issued 27 May 2014 Resolved
Provide 3 fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2014
Resolution: 3 fire buckets provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 May 2014 Resolved
Provide Coast Pilot and NAVRULES.
Due 6 June 2014
Resolved 5 June 2014
Resolution: Coast Pilot and NAVRULES provided.
Construction/Loadline › Hull › Hull Plating
Issued 11 March 2014 Resolved
Complete post wood boat drydock sea trial.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2014
Resolution: Completed satisfactory post wood boat drydock sea trial.
Construction/Loadline › Hull › Hull Plating
Issued 15 March 2011 Resolved
Conducted fastener pull and found marginal fasteners, replace hull fasteners
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2011
Resolution: Entire hull plating was re-fastened below the water line.
Construction/Loadline › Hull › Bottom Plating
Issued 25 January 2011 Resolved
Vessel was shrink wrapped which did not allow for examination of the hull or fasteners. Vessel must complete fastener examination prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2011
Resolution: Fastener pull completed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 January 2011 Resolved
Vessel required to have a bilge high water alarm in the fwd compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2011
Resolved 8 April 2011
Resolution: Verified installation of high level alarm in fwd compartment and operationally tested it.
Construction/Loadline › Hull › Hull Plating
Issued 25 January 2011 Resolved
5 fasteners were found in the fwd compartment to have bairely caught the stem when they were inserted, this area will need to be refastened at the next hull exam due in March 2012.
Due 30 March 2012
Resolved 19 March 2012
Resolution: 5 fasteners were pulled and satisfactorily refastened.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 January 2011 Resolved
Vessel conducts over the rail fishing and must comply with 36 inch rails by next dry-dock.
Due 31 March 2012
Resolved 19 March 2012
Resolution: Vessel owner installed rails on top of bulwarks measuring to 36".
Engineering › Fuel Oil Service System › Valve
Issued 7 April 2010 Resolved
Fuel line from the Port side fuel tank as it exited the emergency fuel shut off valve was found to have a slow leak of a small amount. Required replacement or repair prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2010
Resolution: Fuel line from the Port side fuel tank as it exited the emergency fuel shut off valve was found to have a slow leak of a small amount. Fuel line was tighten and no longer leaked, check both when engine was running and when engine was secured.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 April 2010 Resolved
The navigation lights were found inoperable, suspect corroded wire lead. Required replacement or repair prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2010
Resolution: The navigation lights were found inoperable, suspect corroded wire lead. Wire was replaced and all navigation lights were found operational.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 April 2010 Resolved
The SB side safety rail that is installed along the forward portion of the vessel both port and SB sides, was found to be loosely attached, and unable to restrain 200lb person. Required replacement or repair prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2010
Resolution: The SB side safety rail that is installed along the forward portion of the vessel both port and SB sides, was found to be loosely attached, and unable to restrain 200lb person. The rail had been properly secured to the deck and is now able to provided fo
Fire Fighting › Ventilation Systems › Ducts
Issued 7 April 2010 Resolved
Engine room ventilation was found where the owner was unable to secure ventilation to said space, space contains a fixed fire extinguishing system. Required replacement or repair prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2010
Resolution: Engine room ventilation was found where the owner was unable to secure ventilation to said space, space contains a fixed fire extinguishing system. Owner had manufactured engine room ventilation closures and under my direction briefed his crew in their a
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 April 2010 Resolved
Child life jacket storage space was neither properly marked and was unable to be open easily, as the door was found jammed into the receptive door frame. Required replacement or repair prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2010
Resolution: Child life jacket storage space was neither properly marked and was unable to be open easily, as the door was found jammed into the receptive door frame. The storage space is now properly marked and the door was sanded down to allow for opening and clos
Electrical › Electrical Distribution System (service) › Cable
Issued 7 April 2010 Resolved
Port side battery was found with the main starting cable frayed. Also an associated wire was found unattached. Required replacement and reattachment within 7 days.
Action required: 705 - Other - as specified
Due 14 April 2010
Resolved 16 April 2010
Resolution: Port side battery was found with the main starting cable frayed. Also an associated wire was found unattached. All wires have been properly attached and the main starting cable was replaced new in kind.
Lifesaving › Hand Flares › Storage
Issued 7 April 2010 Resolved
The flare container had rusted through the bottom, a 2 inch hole was found in the old ammunition box. Required replacement within 7 days.
Action required: 705 - Other - as specified
Due 14 April 2010
Resolved 16 April 2010
Resolution: The flare container had rusted through the bottom, a 2 inch hole was found in the old ammunition box. A new plastic water proof container has been installed, and marked appropriately.
Engineering › Bilge Water Management System › Hose
Issued 7 April 2010 Resolved
The dewatering portable pump was found with a small leak on the discharge hose. Required replacement within 7 days.
Action required: 705 - Other - as specified
Due 14 April 2010
Resolved 16 April 2010
Resolution: The dewatering portable pump was found with a small leak on the discharge hose. The leaking hose has been replaced and an operational test confirm proper operation of the portable pump.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 April 2010 Resolved
SB side engine exhaust piping was found with only one clamp installed where two should be employed. Required replacement within 30 days.
Action required: 705 - Other - as specified
Due 7 May 2010
Resolved 9 April 2010
Resolution: SB side engine exhaust piping was found with only one clamp installed where two should be employed. The second clamp has been installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2010 Resolved
On the SB side of main engine a indicator wire was found with its casing cracked and stripped over a 2-3 ft section. Required replacement within 30 days.
Action required: 705 - Other - as specified
Due 7 May 2010
Resolved 16 April 2010
Resolution: On the SB side of main engine a indicator wire was found with its casing cracked and stripped over a 2-3 ft section. The indicating wire assembly has been replaced with a new wiring assembly.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 7 April 2010 Resolved
Oil was found in the Racor fuel filter heat deflection shield, the shield was completely filled with engine lube oil, owner states he changed engine oil week previous and must have spilled said oil. Required cleaning out of defection bowl within 30 days and to monitor the bowl for any build up of oil and if oil builds up to identify the source of the leak.
Action required: 705 - Other - as specified
Due 7 May 2010
Resolved 9 April 2010
Resolution: Oil was found in the Racor fuel filter heat deflection shield, the shield was completely filled with engine lube oil, owner states he changed engine oil week previous and must have spilled said oil. Required cleaning out of defection bowl within 30 days
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 April 2010 Resolved
Bottom most fuel line (return to port side fuel tank) was found with a broken bracket used to secure the line to the bulkhead. Required replacement within 30 days.
Action required: 705 - Other - as specified
Due 7 May 2010
Resolved 16 April 2010
Resolution: Bottom most fuel line (return to port side fuel tank) was found with a broken bracket used to secure the line to the bulkhead. Bracket has been replaced with new, fuel line is now properly supported.
Documentation › Logs/Records › Logbook (official)
Issued 7 April 2010 Resolved
No vessel log book was employed by the owner. Required replacement within 30 days.
Action required: 705 - Other - as specified
Due 7 May 2010
Resolved 16 April 2010
Resolution: No vessel log book was employed by the owner. The owner now has a log book and is beginning to record maintenance and drills.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 7 April 2010 Resolved
No navigation rules publication was found on board vessel. Required replacement within 30 days.
Action required: 705 - Other - as specified
Due 7 May 2010
Resolved 16 April 2010
Resolution: No navigation rules publication was found on board vessel. The navigation rules publication is now on board vessel.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 April 2010 Resolved
Condemned 01 adult life jacket. Required replacement within 30 days prior to warm water as per COI starts 01 JUNE.
Action required: 705 - Other - as specified
Due 7 May 2010
Resolved 16 April 2010
Resolution: Condemned 01 adult life jacket. 01 CG approved lifejacket has been purchased and is now stored properly.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 April 2010 Resolved
Ring Buoy line was found deteriorated. Required replacement within 30 days.
Action required: 705 - Other - as specified
Due 7 May 2010
Resolved 16 April 2010
Resolution: Ring Buoy line was found deteriorated. The ring buoy line has been replaced with new.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 April 2010 Resolved
Painter was found with both ends of line exiting the top of the Container. Water light line was found to be only 11 ft long (7 ft Short). The paddles had neither the name of the vessel and were not attached to the life float in any manner. Tie wraps had been used to secure the bundles of the life lines, the lines were unable to be pulled out to their complete length.
Action required: 705 - Other - as specified
Due 7 May 2010
Resolved 16 April 2010
Resolution: The painter for the life float is now properly attached via the weak link and routed properly. The paddles were now named and attached to the life float. Water-light line was replaced with new 18 ft in length. The life lines are now restrain with breaka
Construction/Loadline › Hull › Side Shell
Issued 27 January 2010 Resolved
bow stem has a series of small scratches(2-3 inches long), and chips (1 inch long) to the wood in this bow stem area. The captain believes these scratches and chips are due to the vessels docking location.
Action required: 705 - Other - as specified
Resolved 24 February 2010
Resolution: The bow stem has received the additional nitrex fiberglass cloth layers, properly applied. The "shield" was installed and secured with the lag bolts. Deficiency rectified.
Construction/Loadline › Penetrations › Valve Flange
Issued 27 January 2010 Resolved
Raw water intake valve located on the port side, is unable to open and or close as the handle was corroded and failed to move the valve before yielding (bending) to the Captains physical force.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2010
Resolution: The Raw water valve has been replaced in kind. The condition of the valve was verified by visual examination of multiple opening and closures of the valve, all satisfactory.
Communications › Radio Communications › EPIRB
Issued 7 April 2009 Resolved
EPIRB hydrostatic release was not current.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2009
Resolution: new hydrostatic release for EPIRB installed.
Engineering › Fuel Oil Service System › Filter
Issued 7 April 2009 Resolved
flame impingement strainer bowl had been removed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2009
Resolution: strainer bowl installed as required.
Fire Fighting › Fire Bucket › Availability
Issued 7 April 2009 Resolved
only 2 of the 3 fire buckets were available.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2009
Resolution: third fire bucket produced, and lanyard attached.
Communications › Visual Communication › Red Warning Signal
Issued 7 April 2009 Resolved
only 4 of the 6 required red flares were available.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2009
Resolution: two additional flares were purchased meeting 6 flare requirement.
Engineering › Bilge Water Management System › Pump
Issued 7 April 2009 Resolved
forward compartment bilge pump does not operate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2009
Resolution: forward compartment bilge working as required.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 7 April 2009 Resolved
5 of the 22 life jackets have missing panels of retro reflective tape.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2009
Resolution: life jackets had received new application of retro reflective tape.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 April 2009 Resolved
no separation of adult/child lifejacket exist.
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 9 April 2009
Resolution: proper separation of child adult life jackets achieved.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 7 April 2009 Resolved
fresh water intake hose 2 inch at point of connection to engine was found dry rotted.
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 4 May 2009
Resolution: hose replaced by owner.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 April 2009 Resolved
SB side running light inoperative.
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 9 April 2009
Resolution: SB side running light displays proper operation.
Operations/Management › Passenger Operations › Safety Orientation
Issued 7 April 2009 Resolved
inefficient passenger count system was employed.
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 4 May 2009
Resolution: passenger count system has been improved and is properly functioning.
Documentation › Logs/Records › Logbook (official)
Issued 7 April 2009 Resolved
no lifesaving equipment record was found to be in use.
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 4 May 2009
Resolution: lifesaving equipment record produced.
Engineering › Fuel Oil Service System › Valve
Issued 24 April 2008 Resolved
emergency fuel shut off valves found excessively corroded and free full rotation of valve unable to confirm open or closed position, require replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2008
Resolution: emergency fuel shut off valves replaced properly.
Fire Fighting › Fire Bucket › Availability
Issued 24 April 2008 Resolved
only 2 of 3 fire buckets were made available.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2008
Resolution: a third fire bucket was purchased and installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 April 2008 Resolved
improperly attached buoyant line.
Action required: 705 - Other - as specified
Resolved 28 April 2008
Resolution: line properly attached.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 April 2008 Resolved
sb nav light inop.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2008
Resolution: sb nav light replaced and tested all sat.
Construction/Loadline › Hull › Keel
Issued 7 March 2008 Resolved
VESSELS KEEL HAS 2 SEPERATE AREAS MEASURING ROUGHLY 7-9 INCHES IN LENGTH AND 4 INCHES IN HEIGHT AND ONE AREA 24 INCHES IN LEGTH BY 6 INCHES IN HEIGHT THAT SHOWS SIGNS OF COATING FAILURE. APPLY PROPER COATING AFTER THROUGH PREPERATION OF RESPECTIVE SITES.
Action required: 705 - Other - as specified
Due 7 April 2008
Resolved 3 April 2008
Resolution: Coating was reapplied and wood is protected properly.
Construction/Loadline › Hull › Stiffener
Issued 7 March 2008 Resolved
Compartment just forward of e/r port side most aft rib frame is deteriorated and needs replacement.
Action required: 705 - Other - as specified
Due 7 April 2008
Resolved 3 April 2008
Resolution: Frame was found with a new sister installed and properly fastened.
Construction/Loadline › Penetrations › Valve Flange
Issued 7 March 2008 Resolved
Compartment just forward of the e/r sb side, excessively corroded valve located just below bilge pump o/b valve needs proper capping off.
Action required: 705 - Other - as specified
Due 7 April 2008
Resolved 3 April 2008
Resolution: corroded valve had been replaced with new ball valve.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 June 2007 Resolved
Replace 9 lifejackets due to punctured fiberous materials pockets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2007
Resolution: Replaced.
Engineering › Steering Gear System › Rudder
Issued 6 June 2007 Resolved
Repair leaking rudder tube
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2007
Resolution: Scarfed in new wood around rudder tube.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 April 2006 Resolved
Provide new eyewash for the first aid kit.
Due 30 April 2006
Resolved 1 May 2006
Navigation › Piloting/Steering › Marine Charts
Issued 17 April 2006 Resolved
Provide up to date navigation charts as per the route listed on the COI.
Due 30 April 2006
Resolved 1 May 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 17 April 2006 Resolved
Repair and demonstrate operation of all high water bilge alarms.
Due 30 April 2006
Resolved 1 May 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 April 2006 Resolved
Provide a 3 to 6 foot lanyard and metallic clip for the ring buoy light.
Due 30 April 2006
Resolved 1 May 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 April 2006 Resolved
Repair the mast head navigation light and demonstrate operation.
Due 30 April 2006
Resolved 1 May 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 April 2005 Resolved
Provide an annual servicing report for the fixed fire system and demonstrate proper operation of the main engine shut down function to the satisfaction of an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 8 April 2005
Resolved 6 April 2005
Resolution: Observed a servicing report for the system and performed an operational test of the engine shut-down function, test sat.
Communications › Audible Communications › Horn/Whistle
Issued 1 April 2005 Resolved
Provide an operational sound signal in accordance with US navigation rules.
Condition: Improper/Lack of Maintenance
Due 1 April 2005
Resolved 6 April 2005
Resolution: New portable sound producing device onboard vessel.
Navigation › Piloting/Steering › Magnetic Compass
Issued 1 April 2005 Resolved
Provide an operational lighted magnetic compass with appropriate deviation table.
Condition: Damaged By Earlier Event
Due 1 May 2005
Resolved 6 April 2005
Resolution: Owner installed a new magnetic compasss.
Lifesaving › Lifefloat › Painter
Issued 1 April 2005 Resolved
Perfom PMS to exterior coating of the lifefloat, label both paddles and secure to the lifefloat.
Condition: Improper/Lack of Maintenance
Due 1 May 2005
Resolved 28 April 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 April 2005 Resolved
PMS the exterior paint coating of the life ring, mark the vessels' name and apply the prescribed retro-reflective tape.
Condition: Improper/Lack of Maintenance
Due 1 May 2005
Resolved 28 April 2005
Operations/Management › Passenger Operations › Safety Orientation
Issued 1 April 2005 Resolved
Proved a crew only sign at the upper deck operating station station ladder.
Condition: Improper/Lack of Maintenance
Due 1 May 2005
Resolved 28 April 2005
Engineering › Fuel Oil Service System › Valve, Control
Issued 1 April 2005 Resolved
Stencil the emergency fuel shut location on the main deck.
Condition: Improper/Lack of Maintenance
Due 1 May 2005
Resolved 28 April 2005
Stability › Watertight Integrity › General
Issued 1 April 2005 Resolved
Provide securing devices for all main deck water tight hatch covers.
Condition: Improper/Lack of Maintenance
Due 1 May 2005
Resolved 28 April 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 April 2005 Resolved
Prove updated asprins and eye wash for the first aid kit.
Condition: Improper/Lack of Maintenance
Due 1 May 2005
Resolved 28 April 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 February 2005 Resolved
Seal various holes and openings in fwd engine room watertight bulkhead.
Condition: Improper/Lack of Maintenance
Due 31 March 2005
Resolved 1 April 2005
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 February 2005 Resolved
Provide watertight deck hatches for all main deck compartments including MDE cover, five total required in accordance with 46 CFR 179.360.
Condition: Improper Installation
Due 31 March 2005
Resolved 1 April 2005
Resolution: Four new WT hatches installed and a 6" combing added to the engine box cover.
Unknown
Issued 12 March 2001 Resolved
REMOVE OILY WATER FROM 2ND COMPARTMENT AND SEAL BOTTOM OF BLKHD BOTH SIDES.
Condition: Unknown
Due 22 June 2001
Resolved 24 August 2001
Lifesaving
Issued 12 March 2001 Resolved
RENEW EPIRB HYDROSTATIC RELEASE.
Condition: Unknown
Due 22 June 2001
Resolved 24 August 2001
Lifesaving
Issued 12 March 2001 Resolved
PROVIDE ON BOARD (02) CHILD PFD'S.
Condition: Unknown
Due 22 June 2001
Resolved 24 August 2001
Engineering
Issued 12 March 2001 Resolved
REINSTALL FUEL SHUT OFF VALVE HANDLES.
Condition: Unknown
Due 22 June 2001
Resolved 24 August 2001
Navigation
Issued 12 March 2001 Resolved
RENEW ALL NAVIGATION PUBS (LIGHT LIST, COAST PILOT, TIDE TABLES).
Condition: Unknown
Due 22 June 2001
Resolved 24 August 2001
Fire Fighting
Issued 12 March 2001 Resolved
PROVE PROPER OPERATION OF FIXED EXTINGUISHING SYSTEM M/E SHUTDOWN.
Condition: Unknown
Due 22 June 2001
Resolved 24 August 2001
Accommodation/Occupational Safety
Issued 5 May 1998 Resolved
STENCIL " DO NOT DISCHARGE IN U.S. WATERS" NEAR TOILET.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Engineering
Issued 5 May 1998 Resolved
STENCIL "EMERGENCY FUEL SHUT OFF"
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Lifesaving
Issued 5 May 1998 Resolved
PROVIDE RETRO-REFLECTIVE MATERIAL ON LIFE FLOAT.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Lifesaving
Issued 5 May 1998 Resolved
RENEW BATTERY ON RING BUOY WATER LIGHT.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Lifesaving
Issued 5 May 1998 Resolved
STENCIL PFD STORAGE LOCATION AND NUMBER.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Lifesaving
Issued 27 March 1997 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE ON THE HIGH SEAS, DEMONSTRATE THE PROPER INSTALLATION AND OPERATION OF A CATEGORY 1 406MHz EPIRB.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Construction/Loadline
Issued 5 February 1997 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, BUT NO LATER THAN 02MAY97, MAKE VESSELAVAILABLE FOR UNDERWAY HULL EXAM.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Navigation
Issued 2 May 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, MAKE PERMANENT REPAIRS TO LEAKING RUDDER PACKING.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Construction/Loadline
Issued 2 May 1994 Resolved
AT NEXT DRYDOCKING, INSTALL POSITIVE CLOSURE VALVES AT THE TWO PORT AND THREE STBD THROUGH-HULL FITTINGS WHICH ARE LOCATED WITHIN 6 INCHES OF THE WATERLINE.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Construction/Loadline
Issued 2 May 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, MAKE PERMANENT REPAIRS TO THE TRANSOM HULL PLANKS WHERE CAULKING IS MISSING BETWEEN PLANKS.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Lifesaving
Issued 2 May 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROVIDE VESSEL FOR AN UNDERWAY RIDE TO CHECK LEAKING RUDDER PACKING REPAIR.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Navigation
Issued 2 May 1994 Resolved
MAKE PERMANENT REPAIRS TO HYDRAULIC STEERING RAM LEAK PRIOR TO 21 MAY 1994
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Documentation
Issued 2 May 1994 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH THE CURRENT EMPLOYER'S DRUG AND ALCOHOLPOLICY.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Construction/Loadline
Issued 12 May 1993 Resolved
PROVIDE DOUBLE HOSE CLAMPS ON ALL TROUGH HULL FITTINGS WITHIN 6" OF _x001C_ WATERLINE.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Documentation
Issued 12 May 1993 Resolved
PROVIDE WRITTEN WASTE MGMT PLAN.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Documentation
Issued 12 May 1993 Resolved
PROVIDE AND POST OIL DISCHARGE PLACARD IN VESSELS MACHINERY SPACES.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Navigation
Issued 12 May 1993 Resolved
PROVIDE ON BOARD VSL CURRENT EDITIONS OF NAVIGATION CHARTS FOR CERTIFICATEDOPERATING AREA.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Navigation
Issued 12 May 1993 Resolved
PROVIDE OPERATIONAL SOUND PRODUCING DEVICE ON BOARD.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Accommodation/Occupational Safety
Issued 24 April 1992 Resolved
TIGHTEN FOREWORD HANDRAILS WHERE MOUNTED TO DECK AND REFASTEN HANDRAIL_x001C_ WHERE NECESSARY WITH SET SCREW OR BOLTS.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Lifesaving
Issued 24 April 1992 Resolved
REPLACE THREE ADULT PERSONAL FLOATATION DEVISES FOUND WITH STRAPS TORN.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Fire Fighting
Issued 24 April 1992 Resolved
HAVE TWO B-11 TYPE DRY CHEMICAL FIRE EXTINGUISHERS.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Navigation
Issued 24 April 1992 Resolved
REPLACE RULES OF ROAR PUBLICATION WITH CURRENT EDITION.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Navigation
Issued 24 April 1992 Resolved
REPLACE COPY OF COAST PILOT PUBLICATION WITH CURRENT EDITION.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Lifesaving
Issued 24 April 1992 Resolved
MAKE REPAIRS TO (12) PERSON LIFEFLOATS GRABLINES AND PATCH/SEAL HOLES.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 13 April 1992 Resolved
STBD SIDE CORNER AFT TO FWD EXTENDING AT LEAST SIX FRAMES(REPLACEMENT PLANKAT LEAST FIVE FT. LONG) COUNTING FROM CAP TO KEEL REMOVE AND REPLACE ROTTENPLANKS #1 AND #2SIDE PLANKING.(NO.3 PLANK TO BE DETERMINED AT LATER DATE BYMARINE INSPECTOR.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 13 April 1992 Resolved
PORT SIDE CORNER AFT TO FWD EXTENDING AT LEAST SIX FRAMES(REPLACEMENT PLANKAT LEAST (5)FT LONG) COUNTING FM CAP TO KEEL REMOVE AND REPLACE ROTTED _x001C_ PLANKS #1 AND #2 SIDE PLANKING. (NO.3 PLANK TO BE DETERMINED AT LATER DATE_x001C_BY MSO PHIL. MARINE INSPECTOR.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 13 April 1992 Resolved
STERN FROM PORT TO STBD REPLACE NO.1,2 AND 5STERN PLANKS. NO.3 TO BE _x001C_ DETERMINED AT A LATER DATE BY MARINE INSPECTOR.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 13 April 1992 Resolved
REPLACE STBD STERN CORNER POST IN KIND.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 13 April 1992 Resolved
PORT SIDE COUNTING FROM PORT SIDE CORNER STERN POST TO FWD, REPLACE THE #1_x001C_CRACKED FRAME.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 13 April 1992 Resolved
REMOVE MAIN DECK STARTING AFT OF THE ENGINE ROOM HATCH TO THE AFTER STEERING COMPARTMENT HATCH , PORT TO STBD.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 13 April 1992 Resolved
AFTER THE DECK AREA IS REMOVED (SEE #6 FOR DETAILS) WILL CONTINUE THE_x001C_ INSPECTION OF THE PORT AND STBD SIDE (2)IN BY (2)IN (STRINGER OR BATTEN) RUNNING FORE AND AFT TO DETERMINE THE EXTENT OF THE DRYROT AND THE REPAIRS_x001C_THAT ARE NECESSARY.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Engineering
Issued 13 April 1992 Resolved
CONDUCT EXTERNAL EXAMINATION OF FUEL TANKS TO DETERMINE IF A HYDROSTATICAL_x001C_TEST OF TANK IS REQUIRED.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 13 April 1992 Resolved
VESSEL WAS REQUIRED TO DRYDOCK PRIOR TO CARRYING PASSENGERS FOR HIRE TO_x001C_ EXAMINE STRUCTURAL DEFICIENCIES.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 13 April 1992 Resolved
REMOVE FIBERGLASS AT STERN ON PORT AND STBD AFT QUARTERS FOR INSPECTION.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Lifesaving
Issued 18 March 1991 Resolved
MARK ALL LOCATIONS WHERE LIFEJACKETS ARE STORED AND TYPE JACKET (ADULT_x001C_ OR CHILDS) STORED THERE.
Condition: Unknown
Due 18 March 1991
Resolved 18 March 1991
Construction/Loadline
Issued 18 March 1991 Resolved
OWNER MUST DRYDOCK VESSEL PRIOR TO CARRYING PASSENGERS FOR HIRE TO MAKE_x001C_ REPAIRS TO BOWSTEM AREA WHERE EXCESSIVE LEAKAGE IS TAKING PLACE.
Condition: Unknown
Due 18 March 1991
Resolved 18 March 1991
Lifesaving
Issued 18 March 1991 Resolved
REPAIR OR REPLACE LIFEFLOAT LIGHT.
Condition: Unknown
Due 18 March 1991
Resolved 18 March 1991
Lifesaving
Issued 18 March 1991 Resolved
REPLACE (1) ADULT LIFEJACKET FOUND UNEXCEPTABLE.
Condition: Unknown
Due 18 March 1991
Resolved 18 March 1991
Electrical
Issued 6 March 1990 Resolved
REPLACE WIRE NUT CONNECTION LOCATED ON ELECTRICAL EQUIPMENT ON BRIDGE.
Condition: Unknown
Due 6 March 1990
Resolved 6 March 1990
Engineering
Issued 6 March 1990 Resolved
MARK REMOTE FUEL SHUTOFF VALVE.
Condition: Unknown
Due 6 March 1990
Resolved 6 March 1990
Engineering
Issued 6 March 1990 Resolved
REPAIR AFT BILGE PUMP.
Condition: Unknown
Due 6 March 1990
Resolved 6 March 1990
Construction/Loadline
Issued 6 March 1990 Resolved
MUST CONDUCT UNDERWAY RIDE OF VESSEL. VESSEL IS A WOODEN HULL VESSEL OVER 15 YEARS OF AGE AND REQUIRES AN UNDERWAY RIDE.
Condition: Unknown
Due 6 March 1990
Resolved 6 March 1990
Engineering
Issued 4 April 1989 Resolved
INSTALL ON BOARD RACOR FUEL FILTER ACCEPTED FOR USE ABOARD COAST GUARD INSPECTED VESSELS.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Construction/Loadline
Issued 3 September 1985 Resolved
DRYDOCK AND REPAIR STARBOARD STERN QUARTER.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985

Casualty record · 2

3 July 2016Routine · role: Involved in a Marine Casualty · activity 5931979
12 January 2018Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6337196
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record