Records from 1985 to 2002. Most recent: inspection, 12 March 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
12 March 2002
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1493124
28 August 2001
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1072292
23 May 2001
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1065972
14 May 2001
Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1065980
22 March 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1417254
18 July 2000
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 821144
18 April 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 213604
29 March 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1372984
26 May 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 803378
30 March 1999
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1464834
24 March 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1122530
4 March 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1434683
19 May 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1107554
15 April 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1411457
11 March 1997
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1462560
11 April 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1081757
31 March 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1442365
25 January 1996
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 879368
4 April 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1151326
21 April 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1167146
5 April 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 856752
22 April 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 827996
31 March 1993
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 835747
21 July 1992
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 944687
14 April 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1268423
4 February 1992
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 946808
3 June 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1002368
17 April 1991
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1307141
23 April 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 924942
5 April 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1219966
6 June 1989
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1196165
9 May 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1340026
29 March 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1210201
11 May 1988
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1351271
22 May 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1333654
6 May 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1327342
15 April 1987
COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1327021
18 June 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1299437
29 April 1986
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1292651
17 April 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 986014
Construction/Loadline
Issued 14 May 2001
Resolved
2 holes were found in the fwd engine room bulkhead, made when the exhaust piping was rerouted. Holes will be permanently sealed, no structural problems observed.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Electrical
Issued 22 March 2001
Resolved
REMOVE OLD POWER BLOWER AND REPAIR HOLE IN STREN BULKHEAD.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Fire Fighting
Issued 22 March 2001
Resolved
ENSURE FWD ENGINE ROOM BLKHD IS VAPOR TIGHT
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Engineering
Issued 22 March 2001
Resolved
REPLACE RAW WATER EXHAUST DISCHARGE HOSES
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Engineering
Issued 22 March 2001
Resolved
PROPERLY VENT FUEL TANK AND VOID
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Lifesaving
Issued 22 March 2001
Resolved
CARRY ONLY 48 PASSENGERS UNTIL PFD'S ARE REPLACED.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Unknown
Issued 29 March 2000
Resolved
Ensure engine room bulkhead is vapor tight_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Unknown
Issued 29 March 2000
Resolved
Install 10 gpm bilge pump in engine room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Unknown
Issued 29 March 2000
Resolved
Install access for fuel shut off valve.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Unknown
Issued 29 March 2000
Resolved
Install covers for engine room vents._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Lifesaving
Issued 30 March 1999
Resolved
Carry only 35 adults until lifejackets are repaired or replaced.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Construction/Loadline
Issued 30 March 1999
Resolved
Install high level bilge alarm in engine room.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Engineering
Issued 30 March 1999
Resolved
Label fuel shut off valve.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Lifesaving
Issued 30 March 1999
Resolved
Install approved first aid kit.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Lifesaving
Issued 4 March 1998
Resolved
Replace retro reflective tape on 7 adult lifejackets. carry no more than 45 adults ontil completed
Condition: Unknown
Due 4 April 1998
Resolved 26 March 1998
Engineering
Issued 4 March 1998
Resolved
Prove proper operation of all engine gauges.
Condition: Unknown
Due 4 April 1998
Resolved 26 March 1998
Electrical
Issued 4 March 1998
Resolved
Remove or properly secure deadend wire from intrument panal.
Condition: Unknown
Due 4 April 1998
Resolved 26 March 1998
Lifesaving
Issued 4 March 1998
Resolved
Replace 60' lifeline on life ring buoy
Condition: Unknown
Due 4 April 1998
Resolved 26 March 1998
Accommodation/Occupational Safety
Issued 15 April 1997
Resolved
repair broken seat back on main deck.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 15 April 1997
Resolved
REPLACE THROUGH HULL FITTING RUBBER BOOT WHERE STEERING CABLE PENETRATES_x001C_ STERN.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Lifesaving
Issued 15 April 1997
Resolved
replace polypropylene line from life ring to waterlight
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Unknown
Issued 11 March 1997
Resolved
PRIOR TO GETTING UNDERWAY WITH PASSENGERS COMPLETE 1ST REINSPECTION INCLUDING SUCCESSFUL COMPLETION OF MAN OVER BOARD DRILL AND PROPER NUMBER AND TYPE OF LIFE SAVING AND FIRE FIGHTING EQUIPMENT.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Construction/Loadline
Issued 31 March 1996
Resolved
REPLACE WARPED FLOORBOARD IN AISLE AFT OF ENTRYWAY.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Engineering
Issued 5 April 1994
Resolved
MARK LOCATION AND OPERATING INSTRUCTIONS FOR FUEL SHUT-OFF.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Accommodation/Occupational Safety
Issued 31 March 1993
Resolved
POST OIL AND GARBAGE POLLUTION PREVENTION PLACARDS ON BOARD.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Lifesaving
Issued 31 March 1993
Resolved
PROVIDE APPROVED RING BOUY AT LEAST 24" IN DIAMETER.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Engineering
Issued 14 April 1992
Resolved
PROVIDE BATTERY BOX FOR ENGINE STARTING BATTERY,
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Engineering
Issued 4 February 1992
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, DEMONSTRATE THE OPERATION OF THE NEWDIESEL ENGINE INSTALLATION TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1992
Resolved 4 February 1992
Lifesaving
Issued 17 April 1991
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE MAKE PERMANENT REPAIR, BY DOUBLE STITCHING SHOULDER AREA ON 45 ADULT LIFE PRESERVERS
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Engineering
Issued 5 April 1990
Resolved
DOUBLE CLAMP FUEL LINE AT BOTH ENDS FROM FUEL FILTER TO FUEL PUMP.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Electrical
Issued 5 April 1990
Resolved
RECRIMP SUMP PUMP GROUND TO MAIN ENGINE.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Construction/Loadline
Issued 5 April 1990
Resolved
RENEW CAULKING IN FOREPEAK ON PORT BOW.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Fire Fighting
Issued 5 April 1990
Resolved
BLOW DOWN BOTH CO2 LINES.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Fire Fighting
Issued 5 April 1990
Resolved
PROVIDE 10' OF HOSE FOR HAND PUMP ON THE DISCHARGE SIDE.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Engineering
Issued 5 April 1990
Resolved
PROVIDE THREE COOLING WATER HOSES.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Engineering
Issued 29 March 1989
Resolved
REPAIR PORT EXHAUST MANIFOLD LEAK.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Electrical
Issued 29 March 1989
Resolved
REMOVE HOUSEHOLD WIRE NUTS FROM ALL ELECTRICAL CONNECTIONS AND INSTALL THE PRESSURE TYPE CONNECTORS.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Navigation
Issued 29 March 1989
Resolved
RENEW PORT NAVIGATION LIGHT LENS (RED).
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Fire Fighting
Issued 29 March 1989
Resolved
SERVICE FIXED C02 FIRE EXTINGUISHING SYSTEM IN BOW.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Electrical
Issued 29 March 1989
Resolved
PROPERLY INSTALL POSITIVE BATTERY CLAMP ON BATTERY.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Navigation
Issued 29 March 1989
Resolved
INSTALL STERN LIGHT (135 DEGREE) AND DISABLE THE ALL AROUND LIGHT AFT (360 DEGREE) WHEN SIDE LIGHTS ARE ENERGIZED. PROVIDE ALL AROUND (360 DEGREE) ANCHOR LIGHT.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Lifesaving
Issued 29 March 1989
Resolved
RENEW LIFE RING BUOY.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Fire Fighting
Issued 29 March 1989
Resolved
POST FIXED FIRE EXTINGUISHER SYSTEM INSTRUCTIONS OUTSIDE FORWARD COMPT.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Lifesaving
Issued 29 March 1989
Resolved
PROVIDE (1) ONE ADULT LIFE PRESERVER, USCG APPROVED, TYPE I.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Electrical
Issued 15 April 1987
Resolved
REMOVE ALL WIRING AND LIGHTS FOR THE 12 VOLT NIGHT LIGHT SYSTEM AS PRESENTLY INSTALLED PRIOR TO CARRYING ANY PASSENGERS. SUBMIT PLANS FOR APPROVAL OF THE REPLACEMENT NIGHT LIGHT SYSTEM PRIOR TO REINSTALLATION.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Lifesaving
Issued 15 April 1987
Resolved
RENEW RING BUOY OF NOT LESS THAN 24 INCHES IN DIAMETER. MARK NEW RING BUOYWITH VESSEL NAME. REQUIREMENT TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Lifesaving
Issued 29 April 1986
Resolved
PROVIDE EMERGENCY CHECK OFF LIST AS REQUIRED BY 46CFR182.25-5.
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Lifesaving
Issued 29 April 1986
Resolved
POST INSTRUCTIONS FOR DONNING LIFE JACKETS OR GIVE VERBAL INSTRUCTIONS PRIOR TO EACH CRUISE.
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Electrical
Issued 29 April 1986
Resolved
PROVIDE GUARDS FOR THE PASSENGER AREA LIGHTING (12 VOLT).
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Fire Fighting
Issued 29 April 1986
Resolved
PROVIDE 1 B-I FIRE EXTINGUISHER AT STEERING STATION. PROVIDE 1 B-I FIRE EXTINGUISHER IN WAY OF ENGINE SPACE. PROVIDE 1 B-II FIRE EXTINGUISHER IN PASSENGER ACCOMMODATION AREA.
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986