MAURY USCG vessel records Sign in
← All vessels

SOLANA

SOLANA is a 1995 freight ship. The Coast Guard has recorded 10 inspections since 1995, most recently in June 2008, along with 8 deficiencies — 2 with no resolution recorded — and 1 operational control.

Records from 1995 to 2008. Most recent: inspection, 15 June 2008.

Built
1995
Last inspected
15 June 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9084580 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
428917
Flag
MALTA
—
Maury page id
psix-428917

Inspections, by type

…with no type recorded6
Years with a record 7 calendar years (1995–2008)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it39279 - Regulatory (Subpart C or D), Gross Ton
39279 - Convention (Subpart B), Gross Ton
24360 - Regulatory (Subpart C or D), Net Ton
24360 - Convention (Subpart B), Net Ton
86850 - Displacement, Ton
75100 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 10

15 June 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3237178
18 September 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2503446
17 August 2005 MARPOL Annex V Examination · NPV Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2464983
22 August 2004 Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2171985
11 March 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2022905
31 May 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 278322
28 February 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 400994
29 April 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 390746
21 February 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 388142
26 October 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 383971

Deficiency record · 8

Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 15 June 2008 No resolution recorded
Vsl was transiting into the Port of Baltimore on 14Jun08 & experienced engine casualty to the main propulsion engine. The micro switch controlling turning gear failed. The C/E affected a temp repair & vsl continued to berth under own power. Class to attest to repairs & ensure proper op of M/E prop. Recd class rpt dated 15JUN08 requiring renewal of failed chip prior to departure from next port
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Firemans Outfit › Gloves
Issued 15 June 2008 No resolution recorded
Vessel is missing one pair of gloves for fireman's outfit. Vessel is to obtain a second pair to satisfaction of USCG prior to departure. As per class rpt dated 15Jun08 due date extended due to class surveyor providing 2 pairs heavy duty flame resistant welders gloves as temporary substitution of firefighting gloves until next port of call.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Construction/Loadline › Structures › Deck Plating
Issued 15 June 2008 Resolved
Grating on exterior of superstructure, starboard side aft, proceeding to outdoor swimming pool is corroded and cracked and is unsafe to walk on. Class will attest to structural integrity of area and adequacy of repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2008
Resolution: Recd class report attesting to grating repaired by the vessels crew by cropping and renewing the corroded section.
Engineering › Steering Gear System › Pump
Issued 17 August 2005 Resolved
The No.2 steering pump hydraulic tank side access plate is leaking hydraulic oil at approximately 1 drop per eight seconds. Repair side access plate to satisfaction of class.
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 19 August 2005
Resolution: Received class report from [name withheld] stating that the Hydraulic tank side access plate was repaired by replacing the gasket seal.
Fire Fighting › Fire Pumps › Arrangement
Issued 17 August 2005 Resolved
The discharge line to the No.2 fire pump has a temporary band clamp patch. Permanently repair to the satisfaction of class.
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 19 August 2005
Resolution: Received class report from [name withheld] stating that the No. 2 fire pump discharge line was cropped and renewed to satisfaction of class.
Documentation
Issued 31 May 2000 Resolved
PROVIDE PROPER LIBERIAN LICENSE FOR 1ST ASST, ENGINEER.
Condition: Unknown
Due 31 May 2000
Resolved 2 June 2000
Documentation
Issued 31 May 2000 Resolved
PROVIDE PROPER LIBERIAN LICENSE FOR CHIEF MATE
Condition: Unknown
Due 31 May 2000
Resolved 2 June 2000
Documentation
Issued 31 May 2000 Resolved
PROVIDE AUTOMATION SURVEY FOR PERIODICALLY UNATTENDED MACHINERY SPACE.
Condition: Unknown
Due 31 May 2000
Resolved 2 June 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.