Records from 1985 to 1989. Most recent: inspection, 20 June 1989.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
20 June 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1044204
25 April 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341526
28 March 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991357
9 July 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326151
18 June 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312931
16 April 1987
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1007165
17 January 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319360
7 November 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013909
23 October 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015101
21 April 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1302896
14 April 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1303015
11 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 981909
5 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289655
Electrical
Issued 28 March 1988
Resolved
REPLACE FRAYED ELECTRICAL CABLE ON FORWARD END OF GENERATOR.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Electrical
Issued 28 March 1988
Resolved
INSTALL/REPLACE WASTED WIRE HANGER SUPPORTS IN ENGINE ROOM/GENERATOR COMPARTMENT.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Construction/Loadline
Issued 28 March 1988
Resolved
REPLACE THE PORT DECK DRAIN HOSE, PORT SIDE IN THE STEERING GEAR COMPART- MENT.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Construction/Loadline
Issued 28 March 1988
Resolved
REPLACE OR SISTER THE 2ND TRANSVERSE UNDERDECK BEAM IN THE FOREPEAK.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Engineering
Issued 28 March 1988
Resolved
INSTALL FLAME SHIELDS ON DAHL FUEL FILTERS.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Unknown
Issued 16 April 1987
Resolved
INSTALL OF WAY NON RETURN VALVES IN BILGE DISCHARGE HOSES.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Fire Fighting
Issued 16 April 1987
Resolved
REPLACE DISCHARGED GAS CYLINDER IN BILL EXTINGUISHER OR PROVIDE ANOTHER ACCEPTABLE EXTINGUISHER.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Navigation
Issued 16 April 1987
Resolved
REPLACE COLORED LENSES IN PORT AND STARBOARD NAVIGATION LIGHTS.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Electrical
Issued 16 April 1987
Resolved
PROVIDE ADEQUATE METAL SUPPORTS FOR ELECTRICAL WIRING UNDER DECK INCLUDING WIRING TO ELECTRIC BILGE PUMPS.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Unknown
Issued 16 April 1987
Resolved
REPLACE PLASTIC BILGE PUMP DISCHARGE HOSE WITH REINFORCED RUBBER HOSE.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Electrical
Issued 16 April 1987
Resolved
MAKE 110-VOLT SPLICE FORWARD OF ENGINE IN A JUNCTION BOX.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Electrical
Issued 16 April 1987
Resolved
CHOCK FORWARD TWO TWELVE VOLT BATTERIES IN THEIR BOX.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Electrical
Issued 16 April 1987
Resolved
RAISE GENERATOR STARTER CABLE OFF EXHAUST AND SECURE TO UNDERDECK.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Construction/Loadline
Issued 23 October 1986
Resolved
RENEW WASTED FASTENERS ON STERN FRAME IN WAY OF KEEL.
Condition: Unknown
Due 23 October 1986
Resolved 23 October 1986
Construction/Loadline
Issued 23 October 1986
Resolved
RENEW ROTTED FRAME PORTSIDE STERN FRAME.
Condition: Unknown
Due 23 October 1986
Resolved 23 October 1986
Electrical
Issued 14 April 1986
Resolved
MAKE GROUNDING CONNECTIONS FOR ALL ELECTRICAL EQUIPMENT.
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Construction/Loadline
Issued 14 April 1986
Resolved
REFASTEN LOWER FLOORS TO FRAMES IN WAY OF BILGES FORWARD OF ENGINE ROOM (ALL FASTENERS 1/3 FASTENERS TO BE RENEWED.
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Engineering
Issued 14 April 1986
Resolved
MAKE EMERGENCY FUEL SHUT-OFF VALVES ACCESSIBLE.
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Construction/Loadline
Issued 14 April 1986
Resolved
MAKE OLD FUEL VENT THROUGH HULL FITTINGS WATERTIGHT.
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Electrical
Issued 14 April 1986
Resolved
AS PER 46 CFR 183.05-50(D)(2) MAKE ALL NECESSARY GROUNDING CONNECTIONS FOR ELECTRICAL EQUIPMENT.
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986