MAURY USCG vessel records
← All vessels

DAVID Z

Built
1953
Last inspected
10 February 2022
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 10 February 2022
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 28 calendar years (1985–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
62 - Regulatory (Subpart C or D), Gross Ton 62 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-42900
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 33

10 February 2022 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7394303
22 January 2019 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6611936
10 May 2016 Internal Structural Exam · COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5873807
25 August 2015 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5226305
26 June 2015 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5164096
4 June 2015 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5144305
25 June 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4899698
27 June 2013 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4672310
4 May 2012 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4302222
28 June 2011 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4060941
8 June 2010 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3762039
30 June 2009 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3519547
20 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3211612
14 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2961134
1 May 2006 Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2638168
28 June 2005 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2407835
16 June 2004 Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2100424
25 June 2003 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1826428
25 July 2002 Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1651985
15 May 2001 Hull Examination · COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1418902
6 May 1994 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 859063
7 May 1993 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 827112
8 May 1992 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 952349
9 May 1991 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 925228
19 October 1990 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 911318
4 September 1990 Damage Survey · Hull Examination · Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 926270
27 April 1990 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 926037
28 April 1989 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1345328
29 April 1988 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1344609
1 May 1987 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1020770
2 May 1986 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1000916
4 November 1985 Credit Drydock
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 987573
3 May 1985 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1291058

Deficiency record · 21

Electrical › Lighting (service) › Lighting Fixture
Issued 28 June 2005 Resolved
Install COLREG approved / style mast lights.
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 21 July 2005
Fire Fighting › Fire Pumps › Arrangement
Issued 28 June 2005 Resolved
Correct pumps suction line as to prevent it from being to low and getting clogged with river mud.
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 21 July 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 28 June 2005 Resolved
Install / replace missing Lifejacket Donning instructions.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 21 July 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 June 2005 Resolved
Post copy of COI on vessel / towing vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 21 July 2005
Engineering › Fuel Oil Service System › Vent Pipe
Issued 28 June 2005 Resolved
Install 20x20 non-corrosive metal mesh on all fuel tank vent pipes.
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 21 July 2005
Lifesaving › Lifebuoys
Issued 25 July 2002 Resolved
Remove tie wraps from lifebuoy line prior to getting underway. LEGACY COMPONENT DESC: Stowage
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 June 2003
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 25 July 2002 Resolved
Properly attach light to lifebuoy prior to getting underway. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 June 2003
Resolution: Installed.
Lifesaving › Lifejacket/PFD (Type II)
Issued 25 July 2002 Resolved
Prior to getting underway with passengers ensure the proper number of PFD's are onboard in accordance with the COI. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 10 June 2003
Resolution: Proper number on scene and inspected. SAT.
Fire Fighting › Fire Pumps
Issued 25 July 2002 Resolved
Repair/renew gauges on fire pumps prior to getting underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 June 2003
Resolution: Gauges installed. Pressure was not 60 psi as required under new "T", however it was concidered adaquate for the vessel.
Construction/Loadline › Markings
Issued 25 July 2002 Resolved
Renew name & home port prior to getting underway. LEGACY COMPONENT DESC: Vessel Name/Home Port
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 June 2003
Resolution: Corrected some time ago. Inpsected as SAT.
Lifesaving
Issued 15 May 2001 Resolved
ATTACH A 60', NON-KINKING, FLOATING LINE TO RING BOUY.
Condition: Unknown
Due 22 May 2001
Resolved 21 May 2001
Fire Fighting
Issued 15 May 2001 Resolved
LENGTHEN FIRE PUMP SUPPLY PIPE TO ENSURE CONTINOUS FLOW IN ALL DRAFT AND RIVER CONDITIONS.
Condition: Unknown
Due 22 May 2001
Resolved 21 May 2001
Construction/Loadline
Issued 27 April 1990 Resolved
THE ENTIRE BOTTOM PLATE AND BILGE KNUCKLE BELOW THE WATERLINE IS VERY PITTED. MANY PITS HAVE BEEN HOLED AND SPOT WELDED TO STOP THE LEAKAGE. REPAIR THESE WASTED AREAS TO THE SATISFACTION OF THE ATTENDING U.S.C.G. MARINE INSPECTOR PRIOR TO PLACING THE VESSEL IN PASSENGER SERVICE.
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Lifesaving
Issued 2 May 1986 Resolved
NO EMERGENCY CHECK OFF LIST POSTED. PROVIDE AND POST EMERGENCY CHECK OFF LIST IN A CONSPICOUS PLACE ACCESSIBLE TO CREW AND PASSENGERS.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Navigation
Issued 2 May 1986 Resolved
REMOVE EXISTING SIDE LIGHTS AND REPLACE WITH USCG APPROVED LIGHTS WHICH ARE CERTIFIED TO MEET ANNEX I OF THE INLAND RULES OF THE ROAD.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Construction/Loadline
Issued 4 November 1985 Resolved
TRANSITION KNUCKLE PLATE WAS WORN THIN AND CRACKED. MAKE PERMANENT REPAIRS TO STERN BY CROPPING BACK TO GOOD METAL AND RENEWING A 8'X2' PLATE AND REWELDING 3 WELDS IN STERN VOID.
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Navigation
Issued 3 May 1985 Resolved
COME INTO COMPLIANCE WITH RULE 24, NAVIGATION RULES FOR A VESSEL BEING TOWED ALONGSIDE SHALL EXHIBIT A STERN LIGHT AND AT THE FORWARD END SIDE LIGHTS.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Fire Fighting
Issued 3 May 1985 Resolved
PROVIDE A FIRE AX.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Fire Fighting
Issued 3 May 1985 Resolved
HAVE PORTABLE FIRE EXTINGUISHERS SERVICED AT AN AUTHORIZED FIRE EQUIPMENT SERVICING FACILITY.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Fire Fighting
Issued 3 May 1985 Resolved
PROVIDE A 50' LENGTH OF 1-1/2" FIRE HOSE AND NOZZLE.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Lifesaving
Issued 3 May 1985 Resolved
INSTALL RETROREFLECTIVE MATERIAL ON ALL PFDS.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.