MAURY USCG vessel records Sign in
← All vessels

BETTY G

BETTY G is a 1953 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1985, most recently in March 2026, along with 106 deficiencies and 7 operational controls.

Records from 1985 to 2026. Most recent: inspection, 19 March 2026.

Built
1953
Last inspected
19 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP5900
Flag
UNITED STATES
367502950
Maury page id
psix-42902

Inspections, by type

…with no type recorded2
Years with a record 36 calendar years (1985–2026)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)32.5 ft × 13.6 ft × 5.3 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBUILT RITE BOAT CO · SANTA MONICA, CA, UNITED STATES · built 1953
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portREDONDO BEACH, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 15 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
11 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5900MMSI 367502950 · active · compulsorily equipped · granted 14 May 2024, expires 14 May 2034
WDF9225MMSI 367502950 · expired · compulsorily equipped · granted 31 August 2011, cancelled 6 November 2021
WDD8158MMSI 367195870 · expired · compulsorily equipped · granted 15 June 2007, cancelled 19 August 2017
WCZ6880MMSI not assigned · expired · voluntarily equipped · granted 3 March 2000, cancelled 8 May 2010
WCZ5399MMSI 367124430 · expired · compulsorily equipped · granted 25 October 1999, cancelled 26 December 2009
WCX3579MMSI 367124420 · expired · compulsorily equipped · granted 1 April 1997, cancelled 3 June 2007
WF4989MMSI not assigned · expired · compulsorily equipped · granted 22 February 1994, cancelled 13 June 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 74

19 March 2026 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8300959
8 August 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8157461
31 July 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7941642
29 February 2024 Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7863497
9 May 2023 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7668240
16 December 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7609172
14 April 2022 Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7431337
15 September 2021 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7308840
8 March 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7151737
19 February 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7143033
20 April 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6941565
18 February 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6911061
14 January 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6889525
11 March 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6640091
30 January 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6617319
1 May 2018 Deficiency Check · Hull Examination · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6400965
25 April 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6394073
24 January 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6342898
5 October 2016 DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6006783
28 April 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5847318
23 February 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5813819
12 January 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5795985
21 September 2011 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4146210
9 September 2011 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4140565
1 July 2009 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3513149
17 June 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3235293
3 June 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3190519
26 March 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3152063
12 July 2007 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3000393
15 June 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2966099
2 April 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2896095
23 May 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2622159
23 March 2006 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2602288
21 July 2005 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2434833
4 May 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2059290
31 March 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2034624
26 June 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1821619
29 March 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1599073
22 March 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1495951
19 June 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1423684
19 March 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1444502
10 March 2001 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1064539
10 March 2001 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1064541
28 March 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1424890
19 January 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 814045
3 January 2000 Damage Survey · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1432216
7 July 1999 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1092559
20 April 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1450266
22 March 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1030406
5 March 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1415136
25 March 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1396885
22 October 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1388378
17 September 1997 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1110042
13 March 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1469812
6 March 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1421080
1 November 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1189346
22 September 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1394385
7 April 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1154516
19 May 1994 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 859936
29 March 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407276
30 March 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1145641
30 April 1992 Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1259039
30 April 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1214861
17 April 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1223369
5 December 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1220523
8 May 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 909217
18 April 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1211221
30 March 1990 COI Inspection · Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 930571
7 April 1989 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 888314
28 April 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1035594
20 April 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1003931
26 March 1987 Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1019637
23 April 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 989559
6 August 1985 Credit Drydock · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 986729

Deficiency record · 106

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 February 2024 Resolved
A vessel that is exposed to salt water more than 3 months in any 12 month period must undergo a dry dock examination and internal structural exam at least once every 2 years. Vessel failed to complete dry dock exam prior to 29FEB2024. Vessel must complete satisfactory dry dock exam prior to returning to service as an inspected small passenger vessel. 46CFR176.600 (c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2024
Resolved 28 March 2024
Resolution: Vessel conduced satisfactory hull exam.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 May 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI observed numerous missing and/or expired items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 5 June 2023
Resolution: MI observed First Aid kit on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 May 2023 Resolved
47 CFR 80.13 Station License required. Stations in the maritime service must be licensed by the FCC either individually or by fleet. One ship station license will be granted for operation of all maritime services transmitting equipment on board a vessel. MI observed FCC expired license.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 5 June 2023
Resolution: Recieived image of FCC regisitration to [name withheld].
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2023 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MI observed vessel missing (1) bucket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 5 June 2023
Resolution: Recieived image of 2.5 gallon bucket labeled Fire Bucket with lanyard attached.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 April 2022 Resolved
Drydock and internal structural examination intervals. A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessels drydock was due on or before 28FEB2022. Vessel is restricted from carrying passengers until receiving credit for drydock.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2022
Resolved 25 April 2022
Resolution: Completed credit dry dock.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 September 2021 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel supply lines. Inspector found the fuel shutoff valves on the port and starboard fuel tanks to be inoperable (deteriorated due to rust).
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 September 2021
Resolution: Vessel operator replaced the wasted/inoperable fuel shutoff valves.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 September 2021 Resolved
Each inlet or discharge pipe that penetrates the full below a line dawn parallel to and at least 6 inches above the deepest load waterline must have a means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Inspector found the closure valve for the bait tank intake pipe to be seized and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 17 September 2021
Resolution: Closure valve was repaired and functions as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 September 2021 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Inspector found the protective guard missing from the main engine (rotating drive belts).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 17 September 2021
Resolution: Engine guard has been installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 September 2021 Resolved
A number of child size life jackets equal to at least ten percent of the number of persons permitted onboard must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller thank the lower size limit of the adult life jackets provided to meet this section. Inspector identified one missing child size life jacket.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2021
Resolved 17 September 2021
Resolution: The child size life jacket has been placed onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 September 2021 Resolved
A vessel must carry adequate and up to date Coast Guard Light List. Inspector found that a Coast Guard Light List was not onboard the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 16 September 2021
Resolution: Vessel operator purchased and placed onboard an up to date U.S. Coast Guard Light List.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 March 2021 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Newly hired deckhand required to pass pre-employment drug test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2021
Resolved 15 March 2021
Resolution: Vessel owner provided proof of DAPI consortium and pre-employment drug test.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 March 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date. Charts and U.S. Coast Pilot outdated, provide proof of updated charts and U.S. Coast Pilot.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2021
Resolved 15 March 2021
Resolution: Vessel owner provided updated charts and U.S. Cost Pilot print outs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 March 2021 Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice or extending the length of a circuit. Electrical lines in the aft fuel tank space to be properly spliced.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2021
Resolved 15 March 2021
Resolution: Removed the wire nuts and soldered the wires together and then used watertight shrink tubing to seal it up. Bait pump in the back lazarette
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 March 2021 Resolved
Each battery must be located as high above the bilge as practicable and free from exposure to water-splash or spray. Port battery box has 1" standing water properly provide dry box for batteries.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2021
Resolved 15 March 2021
Resolution: Vessel owner removed water from battery box.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 March 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Port battery terminal has wasted properly replace corroded connections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2021
Resolved 15 March 2021
Resolution: Vessel owner cleaned terminal posts and upon inspection appeared in satisfactory condition.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 8 March 2021 Resolved
Port fuel tank has small patch on bottom aft weld seam. Starboard fuel tank has patching material on connecting piping, bottom aft right side. At next drydock both patches are to be removed, port and starboard fuel tanks emptied for inspection/testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 11 July 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2021 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel exceeded its 3 month grace period on 06Jan2021. Vessel is required to undergo satisfactory annual inspection prior to departure from port or carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2021
Resolved 8 March 2021
Resolution: Completed satisfactory annual inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2020 Resolved
DUE TO COVID-19 CIRCUMSTANCES BEYOND THE CONTROL OF THE VESSEL, THE VESSEL IS UNABLE TO MEET THE TIMEFRAME AS REQUIRED BY 46CFR176.107. VESSEL IS ALLOWED 90 DAYS TO CONTINUE OPERATIONS ON DOMESTICS ROUTES ONLY, IN ACCORDANCE WITH THE COI, AND IS REQUIRED TO MAKE ITSELF AVAILABLE FOR INSPECTION PRIOR TO 25 JUN 20. IF VESSEL PLANS ON OPERATING ON AN INTERNATIONAL ROUTE, THE OCMI MUST BE NOTIFIED PRIOR TO OPERATION.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 June 2020
Resolved 23 June 2020
Resolution: Completed a virtual annual inspection. No deficiencies.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2020 Resolved
Vessel must complete satisfactory Annual Inspection prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2020
Resolved 27 March 2020
Resolution: Vessel provided objective evidence that was accepted. Vessel was granted a 90 day extension for their annual inspection due to the COVID19 Pandemic.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 January 2019 Resolved
Vessel is past 90 window for the annual exam. Conduct annual exam prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 February 2019
Resolved 11 March 2019
Resolution: Vessel underwent a satisfactory annual inspection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 May 2018 Resolved
Vessel required to complete drydock examination and annual inspection
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 11 May 2018
Resolution: Vessel completed drydock examination and annual inspection.
Documentation › Logs/Records › Logbook (official)
Issued 25 April 2018 Resolved
Vessel wasn't documenting embarkation AND disembarkation of passengers. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Personnel › Training › Passenger Safety
Issued 25 April 2018 Resolved
Crew not present for underway drills. Provide crew for drills prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2018
Resolved 11 May 2018
Resolution: Crew present for drills. Drills Conducted Satisfactorily.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 October 2016 Resolved
Vessel provide proper class "D" DSC radio.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2016
Resolved 5 October 2016
Resolution: Master procured and installed a new Class D DSC radio. Radio check was performed; corrected on spot.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 October 2016 Resolved
Vessel to provide perishable medication in medical kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2016
Resolved 5 October 2016
Resolution: deckhand procured replacements for all expired products; corrected on spot.
Fire Fighting › Fire Bucket › Availability
Issued 5 October 2016 Resolved
Vessel to provide (03) fire buckets with proper markings and lanyard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2016
Resolved 5 October 2016
Resolution: master procured 3 new fire buckets, attached lanyards and properly labeled them; corrected on spot.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 January 2016 Resolved
Complete satisfactory Annual Inspection prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Resolved 23 February 2016
Resolution: Conducted satisfactory Annual Inspection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 September 2011 Resolved
Make vessel available for an annual inspection prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2011
Resolved 29 September 2011
Resolution: Completed COI exam.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 1 July 2009 Resolved
Provide current alcohol test kits IAW 46CFR16.240. Vessel had expired kits. Verified new kits had been sent, but had not yet arrived.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 2 July 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2009 Resolved
Resolve dead end wires on bridge at control station IAW 46CFR183.200.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 2 July 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2009 Resolved
Resolve dead end wires in the engine room at the overhead port side IAW 46CFR183.200.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 2 July 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 July 2009 Resolved
Provide original copy of current valid COI
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 2 July 2010
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 July 2009 Resolved
Provide original copy of current valid COD
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 2 July 2010
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 1 July 2009 Resolved
Provide heat insulation on main diesel engine exhaust piping IAW 46 CFR 182.425 (b) 3. Lagging missing on section from end of engine to water injection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 2 July 2010
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 1 July 2009 Resolved
Provide a copy of 46 CFR Subchapter T.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 2 July 2010
Engineering › Feedwater/Condensate Water System › Pump
Issued 3 June 2008 Resolved
Repair/replace raw water head pump in engine room.
Action required: 705 - Other - as specified
Due 17 June 2008
Resolved 17 June 2008
Resolution: Raw water pump was rebuilt.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 3 June 2008 Resolved
Clean/remove oily water in all bilge spaces to dry state. Locate and repair oil leak on main engine.
Action required: 705 - Other - as specified
Due 17 June 2008
Resolved 17 June 2008
Resolution: Oil/ water removed from bilges.
Engineering › Fuel Oil Service System › Discharge Strainer
Issued 3 June 2008 Resolved
Clean/remove fuel from metal drip pan on fuel strainer. Locate and repair fuel leak.
Action required: 705 - Other - as specified
Due 17 June 2008
Resolved 17 June 2008
Resolution: Fuel leak repaired/fuel cleaned from drip pan.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 3 June 2008 Resolved
Provide Coast Guard approved alcohol test kits onboard vessel.
Action required: 705 - Other - as specified
Due 17 June 2008
Resolved 17 June 2008
Resolution: Provided alcohol test strips.
Communications › Radio Communications › EPIRB
Issued 3 June 2008 Resolved
Replace/renew EPIRB battery (battery due date: 30JUN2008).
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 17 June 2008
Resolution: Provided new EPIRB.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 April 2007 Resolved
Install metal supports spaced not more than 24 inches apart for all cables and wires in the engine room.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 17 June 2008
Resolution: Metal supports installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 April 2007 Resolved
Remove/cap dead end wires throughout the engine room.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 17 June 2008
Resolution: Dead end wires capped off.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 April 2007 Resolved
Provide current radiotelephony certificate for VHF radio. Vessel is restricted to 1000 feet from shore until this requirement is satisfied.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 15 June 2007
Lifesaving › Inflatable Liferafts › Float Free
Issued 23 May 2006 Resolved
Inflatable Liferafts and hydrostatic releases were improperly installed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2006
Resolved 23 May 2006
Resolution: Liferafts and hydrostatic releases were properly installed.
Engineering › Bilge Water Management System › Piping
Issued 23 May 2006 Resolved
Hoses for Bilge pump from engine spaces overboard were kinked and blocked.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2006
Resolved 23 May 2006
Resolution: Piping was replaced and tested satisfactorily using the pump to ensure proper flow rate.
Engineering › Steering Gear System › Power Unit
Issued 23 May 2006 Resolved
Provide means for emergency steering.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2006
Resolved 26 May 2006
Resolution: Demonstrated operation of emergency steering using emergency tiller.
Engineering › Bilge Water Management System › Pump
Issued 23 March 2006 Resolved
1. Permanently mount all bilge pumps (forward spaces and lazarette) per 46 CFR 182.520.
Condition: Unknown
Due 23 April 2006
Resolved 24 March 2006
Resolution: The pumps were mounted to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 March 2006 Resolved
Remove all dead end wires and wires not in use throughout the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 April 2006
Resolved 24 March 2006
Resolution: All loose and/or dead end wire were removed, as well as all wire not in service were removed and/or capped off to the satisfaction of the attending Marine Inspector..
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 March 2006 Resolved
Ensure that all penetrations between the lazarette and the engine room are watertight per 46 CFR 179.320. to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 April 2006
Resolved 24 March 2006
Resolution: All penetrations between the lazarette and the engine room were sealed and watertight to the satisfaction of the attending Marine Inspector. The stuffing box around the shaft was replaced and sealed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 29 July 2005 Resolved
Provide proof of enrollment in CG approved drug and alcohol testing program.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 2 August 2005
Resolution: Valid document found.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 29 July 2005 Resolved
Provide circuit protection for port side battery bank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 2 August 2005
Resolution: In-line fuse installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 July 2005 Resolved
Provide operational high water bilge alarms in all required spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 2 August 2005
Resolution: All three alarms are operational.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 July 2005 Resolved
Provide vaild COD
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 2 August 2005
Resolution: Valid document was found.
Documentation › Certificates/Documents › FCC SSL
Issued 29 July 2005 Resolved
Provide FCC Radiotelephony Safety Certificate
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 2 August 2005
Resolution: Valid documnet was found.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 29 July 2005 Resolved
Provide labeling on outside of emergency escape leading from accomodation space below main deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 2 August 2005
Resolution: Sign installed
Fire Fighting › Means of Escape › Emergency Lighting
Issued 29 July 2005 Resolved
Provide emergency lighting that automatically actuates upon loss of normal power for accomodation space below main deck.
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 2 August 2005
Resolution: Emergency lighting installed in unused forward storage area.
Communications › Radio Communications
Issued 4 May 2004 Resolved
Provide proof of current EPIRB registration. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2004
Resolved 7 May 2004
Resolution: Provided fax copy of current EPIRB registration.
Documentation › Certificates/Documents
Issued 4 May 2004 Resolved
Provide proof of current charts IAW 46 CFR § 184.420.
Action required: 705 - Other - as specified
Due 13 May 2004
Resolved 5 May 2004
Resolution: Provided proof of current charts IAW 46 CFR § 184.420.
Fire Fighting › Miscellaneous Items
Issued 4 May 2004 Resolved
Install fire detection system IAW 46 CFR §176.810(a)(7).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2004
Resolved 5 May 2004
Resolution: Installed fire detection system IAW 46 CFR §176.810(a)(7).
Fire Fighting › Nozzles
Issued 4 May 2004 Resolved
Repair/replace fire hose and install proper nozzle IAW 46 CFR 181.320.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2004
Resolved 5 May 2004
Resolution: Replaced fire hose and install proper nozzle IAW 46 CFR 181.320.
Fire Fighting › Miscellaneous Items
Issued 4 May 2004 Resolved
Provide proof of fire extinguishing service record IAW 46 CFR § 176.81(b)(1).
Action required: 705 - Other - as specified
Due 8 May 2004
Resolved 5 May 2004
Resolution: Provided proof of fire extinguishing service record IAW 46 CFR § 176.81(b)(1).
Lifesaving › Lifebuoys
Issued 26 June 2003 Resolved
Life ring buoy in poor, unserviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 26 June 2003
Resolution: New life ring buoy purchased and placed on board.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 26 June 2003 Resolved
B-I portable extinguisher at operating station is overdue for servicing. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 17 July 2003
Resolution: Received proof of servicing report.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 April 2002 Resolved
Make emergency hatch cover operable from both sides.
Condition: Placed in Improper Service
Due 2 May 2002
Resolved 9 May 2002
Documentation › Certificates/Documents
Issued 2 April 2002 Resolved
Documentation Certificate missing annual endorsement. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2002
Resolved 5 April 2002
Construction/Loadline › Structures
Issued 2 April 2002 Resolved
Make hole in bulkhead between engine room and lazerette gas tight. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 7 April 2002
Resolved 3 April 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 2 April 2002 Resolved
Fire detecting system must have an audible/visual indicator at the operating station.
Due 2 May 2002
Resolved 9 May 2002
Lifesaving
Issued 19 March 2001 Resolved
Schedule a verification exam by a Coast Guard Maine Inspector of the required lifesaving equipment not later than 10 May. The vessel may operate under its current route and passenger load with existing equipment only until the above date.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Construction/Loadline
Issued 28 March 2000 Resolved
Provide portable hand bilge pump IAW 46 CFR 182.520 (a).
Condition: Unknown
Due 27 April 2000
Resolved 8 May 2000
Accommodation/Occupational Safety
Issued 28 March 2000 Resolved
Mark emergency escape hatch IAW 46 CFR 185.606.
Condition: Unknown
Due 27 April 2000
Resolved 8 May 2000
Lifesaving
Issued 28 March 2000 Resolved
Mark bouyant apparatus with vessel name and capacity IAW 46 CFR 185.604.
Condition: Unknown
Due 27 April 2000
Resolved 8 May 2000
Construction/Loadline
Issued 28 March 2000 Resolved
Make machinery space (engine compartment) gas tight IAW 46 CFR 181.400.
Condition: Unknown
Due 27 April 2000
Resolved 8 May 2000
Fire Fighting
Issued 3 January 2000 Resolved
Install mounting bracket for manual Actuation cable for pre-engineered fixed fire system.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Fire Fighting
Issued 3 January 2000 Resolved
Make engineroom gastight for pre-engineered fixed fire fighting system IAW 46 CFR 181.400.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Electrical
Issued 3 January 2000 Resolved
Reconnect bonding wires in engine room to sea valves.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Construction/Loadline
Issued 3 January 2000 Resolved
Install bilge pump in engine room IAW 46 CFR 182.520.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Documentation
Issued 5 March 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Lifesaving
Issued 5 March 1999 Resolved
Provide separate stowage for child/adult lifejackets as per 46 CFR 180.71- 78.
Condition: Unknown
Due 21 April 1999
Resolved 22 April 1999
Navigation
Issued 5 March 1999 Resolved
Repair port navigation running light.
Condition: Unknown
Due 5 March 1999
Resolved 22 March 1999
Engineering
Issued 5 March 1999 Resolved
Repair fuel shutoff valve to port fuel tank.
Condition: Unknown
Due 5 March 1999
Resolved 22 March 1999
Documentation
Issued 5 March 1999 Resolved
Provide current renewal sticker on Document of Certification as per 46 CFR 67.01-5.
Condition: Unknown
Due 18 April 1999
Resolved 22 April 1999
Documentation
Issued 5 March 1999 Resolved
Provide current drug policy and results as per 46 CFR 16.230.
Condition: Unknown
Due 18 April 1999
Resolved 22 April 1999
Navigation
Issued 6 March 1996 Resolved
PROVIDE CORRECTED NAVIGATIONAL CHARTS AND PUBLICATIONS.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Navigation
Issued 6 March 1996 Resolved
PROVIDE PROPER NAVIGATIONAL PLOTTING EQUIPMENT.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Construction/Loadline
Issued 22 September 1995 Resolved
Remove rotted butt block underdeck port side of engine and renew as original.
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Construction/Loadline
Issued 22 September 1995 Resolved
Remove rotted section of old engine stringer on port side of engine and renew as original.
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Navigation
Issued 30 March 1993 Resolved
PROVIDE CURRENT NAVIGATION PUBLICATIONS AS LISTED BELOW (WHERE INDICATED BYAN (*), COPIES OF THE SECTION FOR OPERATING AREAS IN THE PUBLICATION ARE AUTHORIZED FOR USE ONBOARD): COAST PILOT*, LIGHT LIST*, TIDE TABLES*,_x001C_ RULES OF THE ROAD, AND 46 CODE OF FEDERAL REGULATIONS "SUBCHAPTER T".
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Engineering
Issued 17 April 1991 Resolved
REPLACE WATER INJECTION HOSE TO ENGINE EXHAUST AND ENSURE NEW HOSE IS DOUBLE-CLAMPED.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Engineering
Issued 17 April 1991 Resolved
REPLACE FLAME ARRESTOR FOR THE FUEL OIL STRAINER.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Electrical
Issued 17 April 1991 Resolved
PROPERLY DEAD-END ALTERNATE STARTING WIRE FROM PORT BATTERY BANK.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Navigation
Issued 17 April 1991 Resolved
PROVIDE ON BOARD SIX CURRENT ORANGE SMOKE FLARES.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Fire Fighting
Issued 17 April 1991 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Engineering
Issued 30 March 1990 Resolved
PROPERLY MOUNT BOTH ELECTRICAL BILGE PUMPS AND DISCHARGE HOSES.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Navigation
Issued 30 March 1990 Resolved
STRENGTHEN MOUNTING FOR STEERING RAM.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Fire Fighting
Issued 30 March 1990 Resolved
REPLACE BROKEN KEEPER WIRE ON ONE B-II FIRE EXTINGUISHER AND PROPERLY MOUNTALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Construction/Loadline
Issued 30 March 1990 Resolved
INSTALL CAPTURE CHAINS OR HINGES AND CLOSURE DEVICES, AND PROVE WEATHER- TIGHTNESS OF ALL HATCHES EXPOSED TO WEATHER.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Engineering
Issued 30 March 1990 Resolved
RENEW FLAME SCREEN IN PORT FUEL TANK VENT.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Electrical
Issued 30 March 1990 Resolved
PROPERLY FUSE BRANCH CIRCUIT SUPPLYING PASSENGER CABIN LIGHTS.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Accommodation/Occupational Safety
Issued 30 March 1990 Resolved
PROVE PROPER OPERATION OF MSD AND VENT TO EXTERIOR OF VESSEL.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Engineering
Issued 7 April 1989 Resolved
REMOVE ALL PIPING TO STARBOARD FUEL TANK.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 28 April 1988 Resolved
PROVIDE 1 ADULT LIFE PRESERVER.
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Electrical
Issued 28 April 1988 Resolved
CONNECT OR REMOVE BONDING TO GEAR BOX AND TO ENGINE DRIVEN BAIT PUMP.
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Lifesaving
Issued 28 April 1988 Resolved
REPLACE ALL PENDANTS AND LIFELINE, AND REATTACH 100 FT PAINTER TO BUOYANT APPARATUS IAW 46 CFR 180.15-5(A),(C).
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Lifesaving
Issued 28 April 1988 Resolved
REPLACE RING BUOY IAW 46 CFR 180.30-5(A) AND 46 CFR 180.30-10(A),(C).
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Navigation
Issued 26 March 1987 Resolved
REPLACE WOODEN STRONG BACK OF THE STEERING GEAR'S GEAR BOX.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Construction/Loadline
Issued 26 March 1987 Resolved
PROVE PROPER OPERATION OF HAND PUMP MOUNTED IN BUNK ROOM.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.