MAURY USCG vessel records Sign in
← All vessels

EVER YOUNG

EVER YOUNG is a 1995 freight ship. The Coast Guard has recorded 17 inspections since 1996, most recently in January 2012, along with 8 deficiencies and 3 operational controls.

Records from 1996 to 2012. Most recent: inspection, 9 January 2012.

Built
1995
Last inspected
9 January 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9080649 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
429199
Flag
SOUTH KOREA
—
Maury page id
psix-429199

Inspections, by type

…with no type recorded10
Years with a record 9 calendar years (1996–2012)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it38637 - Convention (Subpart B), Gross Ton
23959 - Convention (Subpart B), Net Ton
83829 - Displacement, Ton
73081 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

9 January 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4217054
24 November 2010 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 3898433
24 November 2010 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3902787
23 November 2010 Ballast Water Examination · MARPOL Annex I Examination · Deficiency Check · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3892568
22 November 2010 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 3893921
21 November 2010 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 3893628
17 November 2010 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3893325
28 January 2009 ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3391822
12 November 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3097696
8 November 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3095252
2 July 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2980958
11 February 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2004899
11 February 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2004971
18 April 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1606328
29 October 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 434027
22 March 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 401839
9 February 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 387824

Deficiency record · 8

Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 23 November 2010 Resolved
0945 - Operating instructions for liferafts shall be provided with emergency lighting. Forward liferaft instructions is missing emergency lighting. SOLAS ConsED 97, CHIII, REG 9.2.3, 70c
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 17 January 2011
Resolution: Deficiencies rectified to the satisfaction of CG Marine Inspector.
Construction/Loadline › Structures › Rake
Issued 23 November 2010 Resolved
1299 - Guard rails shall be fitted around all exposed decks. Middle course of gangway, port side guard rail is missing. ICLL Annex I, Reg 25.3 - 70c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 January 2011
Resolution: Deficiencies rectified to the satisfaction of CG Marine Inspector.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 23 November 2010 Resolved
0699 - Ship's voyage data recorder is inoperable, Solas 2009, CH.I, Reg.11, CH.VR.20.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 January 2011
Resolution: Deficiencies rectified to the satisfaction of CG Marine Inspector.
Operations/Management › Log/Records › Ballast Water Logs/Records
Issued 23 November 2010 Resolved
2120 - The garbage management plan shall be followed by the crew. Ship's plan names Chief Engineer as custodian and person responsible for entries in the garbage record book. The [name withheld] has been making all garbage record book entries. Marpol 73/78, Rg. 8(2), Annex V.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 January 2011
Resolution: Deficiencies rectified to the satisfaction of CG Marine Inspector.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 November 2010 Resolved
Fire resistance of doors shall be equivalent to that of the division in which they are fitted. Door in "A" boundary in Officer's Mess unable to close as required. Solas Cons Ed 97, CH II-2, R.47.1.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 January 2011
Resolution: Deficiencies rectified to the satisfaction of CG Marine Inspector.
Lifesaving › Buoyant Apparatus › Marking
Issued 23 November 2010 Resolved
0650 - Each lifebuoy shall be marked in block letters with the name and port of registry of the ship. Two lifebuoys on Starboard side found without required markings. Solas cons Ed 97, CH III, Reg 7-1.4.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 January 2011
Resolution: Deficiencies rectified to the satisfaction of CG Marine Inspector.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 23 November 2010 Resolved
Fire resistance of doors shall be equivalent to that of the division in which they are fitted. Door in "A" boundary in Crew's Mess unable to close as required. Solas Cons Ed 97, CH II-2, R.47.1.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 January 2011
Resolution: Deficiencies rectified to the satisfaction of CG Marine Inspector.
Electrical › Electric Generation Source (emergency) › Generator
Issued 16 November 2010 Resolved
Emergency generating sets shall have stored energy capable of three consecutive starts. Primary means of starting emergency generator is inoperable due to starter motor failure. Repair to satisfaction of class surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2010
Resolution: Received Class Survey report stating that Class has issued a condition upon the vessel for its Emergency generator to starting arrangements to be repaired not later than 22 DEC 2010.

Ownership record