MAURY USCG vessel records Sign in
← All vessels

MOLAVE

MOLAVE is a 1995 freight ship. The Coast Guard has recorded 13 inspections since 1995, most recently in June 2003, along with 9 deficiencies and 4 operational controls, 1 with no removal date recorded.

Records from 1995 to 2003. Most recent: operational control imposed, 11 June 2003.

Built
1995
Last inspected
11 June 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9074705 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
429205
Flag
PHILIPPINES
—
Maury page id
psix-429205

Inspections, by type

…with no type recorded10
Years with a record 9 calendar years (1995–2003)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it15932 - Regulatory (Subpart C or D), Gross Ton
9568 - Regulatory (Subpart C or D), Net Ton
26435 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BMC 3 Freight Barge · MISLE 50951 · 9 May 1999 · activity 524440

Inspection history · 13

11 June 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1814748
2 June 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1810281
27 May 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1802937
13 May 2003 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1792854
20 March 2002 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1496063
17 October 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 294689
23 July 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 280010
18 December 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 435680
9 May 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 524440
24 October 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 421870
25 October 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 409038
7 October 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 396191
14 September 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 382523

Deficiency record · 9

Navigation › Piloting/Steering
Issued 11 June 2003 Resolved
Vessel has inoperable gyro compass. Repair to the satisfaction of Class prior to departure. LEGACY COMPONENT DESC: Gyro Compass
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2003
Resolved 11 June 2003
Resolution: Received technician''s report attesting to satisfactory repairs to gyro compass.
Navigation › Collision/Grounding Avoidance
Issued 2 June 2003 Resolved
Vessels secondary radar inoperative. Vessel entered port under Letter of Deviation. Radar was not repaired at time of inspection. Repair scheduled to take place in Houston prior to departure. LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2003
Resolved 10 June 2003
Resolution: Rcvd class report attesting to repairs
Navigation › Piloting/Steering › Gyro Compass
Issued 13 March 2002 Resolved
Vessel reported gyrocompass was not functioning. Issued LOD to enter port w/permanent repairs rqrd prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2002
Resolution: Received technician repair report.
Fire Fighting
Issued 18 December 1999 Resolved
Make fire door from E/R to main deck and paint locker fire door firetight (repair so that they can close and seal completely), SOLAS 74 AMD II/2-47.
Condition: Unknown
Due 18 February 2000
Resolved 18 February 2000
Fire Fighting
Issued 14 September 1995 Resolved
Remove hold back devices to fire doors for stair tower and emergency fire pump/steering gear compartment._x001C_ _x001C_ Solas Ch. II-2, Reg 47 (2)
Condition: Unknown
Due 14 September 1995
Resolved 14 September 1995
Fire Fighting
Issued 14 September 1995 Resolved
Remove open paint container from emergency generator and decks stores compartment and move to paint locker._x001C_ _x001C_ Solas Ch II-2, Reg 2 (1).
Condition: Unknown
Due 14 September 1995
Resolved 14 September 1995
Lifesaving
Issued 14 September 1995 Resolved
Provide additional lifejacket for duty personnel in engine control room._x001C_ _x001C_ _x001C_ Solas Ch III, Reg 7 (2.2.1)
Condition: Unknown
Due 14 September 1995
Resolved 14 September 1995
Electrical
Issued 14 September 1995 Resolved
Provide rubber mat for area in front of emergency generator electrical panel._x001C_ _x001C_ Solas Ch II-1, Reg 40 (1.3)
Condition: Unknown
Due 14 September 1995
Resolved 14 September 1995
Accommodation/Occupational Safety
Issued 14 September 1995 Resolved
Remove the rat poison, pesticides, phenol and cresol solutions from the hospital._x001C_ _x001C_ ILO 147
Condition: Unknown
Due 14 September 1995
Resolved 14 September 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.