TORTUGA

TORTUGA is a 1954 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in May 2026, along with 26 deficiencies, 3 operational controls and 1 casualty investigation in 2006.

Records from 2006 to 2026. Most recent: inspection, 12 May 2026.

Built
1954
Last inspected
12 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP5906
Flag
UNITED STATES
Maury page id
psix-42929

Documentation record

Registered dimensions (L × B × D)37.4 ft × 13.8 ft × 3.9 ft
Registered tonnagegross 15 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBUILT RITE BOATS · SANTA MONICA, CA, UNITED STATES · built 1954
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 2 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Gross Ton
11 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

18 inspections, each with its date, unit and type; 26 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

12 May 2026 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8332102
11 August 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8156059
26 March 2025 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8074113
28 May 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7875191
22 May 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7662756
22 February 2023 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7631846
17 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7425295
13 May 2021 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7188978
22 April 2021 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7180869
2 April 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7167837
13 October 2020 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7076176
20 July 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7011314
4 October 2019 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6825140
27 March 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6636582
10 September 2018 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6537427
3 November 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6299874
15 March 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6085712
17 May 2016 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5862453

Deficiency record · 26

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2025 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. MI observed wood decay in internal frame on port side of the generator room. 46 CFR 176.610(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2025
Resolved 20 August 2025
Resolution: MI received photos from vessel operator of treated frame in the port side of the generator room.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 May 2022 Resolved
The EPIRB test shall be logged or otherwise documented. Vessel was not properly documenting testing of monthly EPIRB tests.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2022
Resolved 17 May 2022
Resolution: Operator properly logging EPIRB tests.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2022 Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspections if the expiration date of the battery has passed. Vessel lifebuoy and buoyant apparatus water light batteries were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2022
Resolved 23 May 2022
Resolution: Water-light batteries have been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2022 Resolved
At least one ring life buoy must be fitted with a lifeline. Each lifeline on a ring life buoy must at least 60 feet in length. Vessel did not have the proper length for the life-line on life buoy.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2022
Resolved 23 May 2022
Resolution: A life-line (throw line) of sixty feet has been placed onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 17 May 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Inspector found that the crew could not demonstrate last update of the electronic navigation chart software and could not demonstrate that the chart software was derived from an approved chart maker (e.g. NOAA, ACOE, River Authority).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2022
Resolved 29 July 2022
Resolution: An up-to-date electronic chart card based upon NOAA data has been installed onboard the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 April 2021 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel exceeded two year interval on 31MAR2021. Vessel required to undergo satisfactory drydock examination prior to departure from port or carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2021
Resolved 22 April 2021
Resolution: Vessel completed hull examination for credit dry dock.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 October 2019 Resolved
A vessel applicable to Subchapter T may not be operated without having a valid U.S. Coast Guard Certificate Of Inspection onboard. Owner/Operator had not scheduled and operated vessel beyond the Annual Inspection/Anniversay date of the Certificate of Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
Resolution: The Annual Inspection was completed on October 4, 2019.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 4 October 2019 Resolved
Lifefloat must be attached with a float-free link. Capacity/breaking rating tag was missing from the float-free link.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2019
Resolved 8 October 2019
Resolution: Float-free link rating tag was fixed to the float-free link.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2019 Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Rail connection was loose near the pilot house. Requires repair to make a secure connection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2019
Resolved 8 October 2019
Resolution: Rail was properly/securely fixed to the vesels structure.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 October 2019 Resolved
A vessel on an limited coastwise voyage must carry six hand held red flares. Two flares found to be expired; Replace with updated flares.
Action required: 10 - Deficiency Rectified
Due 18 October 2019
Resolved 4 October 2019
Resolution: Owner purchased new flares and placed them onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 October 2019 Resolved
A vessel must carry a first-aid kit approved under approval series 160.401. First-Aid kit was found to be expired.
Action required: 10 - Deficiency Rectified
Due 18 October 2019
Resolved 4 October 2019
Resolution: Owner purchased and placed a valid first-aid kit onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 October 2019 Resolved
Vessel must be operated in accordance with applicable laws and regulations. Navigation charts were expired and not up to date with corrections. Updated charts are required onboard the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2019
Resolved 8 October 2019
Resolution: Updated charts were placed onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 September 2018 Resolved
Provide updated Light List.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2018
Resolved 17 September 2018
Resolution: This discrepancy was corrected to the satisfaction of the Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 September 2018 Resolved
Provide updated Coast Pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2018
Resolved 17 September 2018
Resolution: This discrepancy was corrected to the satisfaction of the Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 September 2018 Resolved
Provide current FCC Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2018
Resolved 17 September 2018
Resolution: This discrepancy was corrected to the satisfaction of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 September 2018 Resolved
Renew Retroreflective tape on life ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2018
Resolved 17 September 2018
Resolution: This discrepancy was corrected to the satisfaction of the Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 September 2018 Resolved
Make vessel available for annual inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2018
Resolved 13 September 2018
Resolution: Completed annual inspection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 November 2017 Resolved
VSL IS REQUIRED TO CONDUCT SATISFACTORY ANNUAL EXAMINATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS. 46CFR176.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2017
Resolution: COMPLETED SATISFACTORY ANNUAL INSPECTION. ENDORSED COI.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 May 2016 Resolved
Provide 03 new batteries for waterlights. Vessel is restricted to daytime operations until complete.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 1 June 2016
Resolution: Replaced batteries in 3 water lights.
Lifesaving › Lifefloat › Retroreflective Material
Issued 17 May 2016 Resolved
Provide new retroreflective tape for both lifefloats and life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 June 2016
Resolution: Added new retroreflective tape to the lifefloats and lifering bouy
Lifesaving › Hand Flares › Expired
Issued 17 May 2016 Resolved
Provide 02 red hand flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 June 2016
Resolution: Provided new red hand flares.
Engineering › Bilge Water Management System › Hose
Issued 17 May 2016 Resolved
Provide a hose of sufficient length for portable bilge hand pump to pump overboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 17 May 2016
Resolution: Operator provided 5 gallon buckets for hand bilge pump to pump into in spaces hose length was found to insufficient for.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 May 2016 Resolved
Provide guard for rotating belt on engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 June 2016
Resolution: Guard provided for rotating belt on engine.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2016 Resolved
Remove or cap dead end wiring ID'd in bridge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 June 2016
Resolution: Dead end wires capped on bridge.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 May 2016 Resolved
Provided proof of current enrollment in DAPI consortium.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 18 May 2016
Resolution: Owner emailed proof of company's current DAPI enrollment.
Engineering › Steering Gear System › Bracket/Clamp
Issued 17 May 2016 Resolved
Provide second hose clamp for flex hose on shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 May 2016
Resolution: Operator installed a second hose clamp.

Casualty record · 1

29 October 2006Routine · role: Involved in a Marine Casualty · activity 2811046
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.