13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2026
Resolved
Vessel's port exhaust pipe had a leak and was leaking fumes into the void space. Vessel owner/operator shall repair or replace that section of pipe to ensure proper operation and safety of passengers and crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2026
Resolved 29 July 2026
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 June 2026
Resolved
Vessel's stern had holes penetrating the hull above the water line where an old sign had been removed. Repair holes to provide watertight integrity.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 June 2024
Resolved
Battery covers were found unsecured. Reinstall battery covers as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2024
Resolved 9 July 2024
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 28 June 2024
Resolved
Engine room bulkhead penetration was not sealed. Repair forward engine room bulkhead penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2024
Resolved 9 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 September 2023
Resolved
Upper deck life ring grab line was deteriorating. Replace upper deck life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 October 2023
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 September 2023
Resolved
Remote fuel shut off handles were not labeled. Label shut off handles.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 October 2023
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 September 2023
Resolved
Remove oily water mixture from engine room bilge. Consider way to separate leaking shaft cooling water and engine room bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 October 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 September 2023
Resolved
Stern navigation light was inadequate. Repair or replace bulb as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 October 2023
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 September 2023
Resolved
Fire pump did not produce a sufficient stream. Replace fire pump as necessary to ensure sufficient stream prior to 2024 operating season.
Action required: 705 - Other - as specified
Resolved 28 June 2024
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 15 September 2022
Resolved
Vessel Owner/Operator Shall drills are conducted under the observation of the local Marine Inspector once the vessel is placed back in the water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2023
Resolved 18 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 September 2022
Resolved
CP2- Vessel Owner/Operator shall ensure all lifesaving equipment is placed back on station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2023
Resolved 18 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 September 2022
Resolved
Machinery- Operationally test vessels generator and propulsion system once the vessel is placed back in the water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2023
Resolved 18 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 August 2020
Resolved
Lifering line was deteriorating and requires replacement.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2020
Resolved 25 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 August 2020
Resolved
Light List not onboard for the area of operation
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2020
Resolved 25 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 August 2020
Resolved
No coast pilot on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2020
Resolved 25 August 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 August 2020
Resolved
Light fixture above port engine was missing cage guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2020
Resolved 25 August 2020
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 August 2020
Resolved
Remote fuel shut off for starboard engine was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 August 2020
Resolved 11 August 2020
Resolution: Corrected on site
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 August 2020
Resolved
Replace 03 lifejackets found to be unservicable.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2020
Resolved 25 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2019
Resolved
Vessel is required to have a fuel shutoff valve that is
operable from outside the tank compartment. During the
inspection starboard fuel shut off was not functional.
The operator was able to correct on the spot. The
deficiency is cleared.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 July 2019
Resolved 11 July 2019
Resolution: The vessel's crew corrected the deficiency on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2019
Resolved
The vessel is required to have strong and effective
rudder stops to prevent jamming and damage to the rudder
and its fittings. The rudder stops are not touching on
both hard port and starboard. Correct within 14 days.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 26 August 2019
Resolution: Received video from vessel rep showing newly installed rudder stops clearing deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 June 2018
Resolved
First-aid kit must have all of the items listed in referenced cite.*Multiple items expired*
Action required: 10 - Deficiency Rectified
Due 25 July 2018
Resolved 19 July 2018
Resolution: Attended vessel finding new kit on board.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 25 June 2018
Resolved
Provide on board vessel the Certificate of Documentation.
Action required: 10 - Deficiency Rectified
Due 25 June 2018
Resolved 19 July 2018
Resolution: Original provided on board vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2018
Resolved
Provide wire supports for navigation lights on second deck.
Action required: 10 - Deficiency Rectified
Due 25 July 2018
Resolved 19 July 2018
Resolution: Attended vessel witnessing sat repairs.
01 - Certificates & Documentation › 011 - Ships Certificates › Operational Limitations for Passenger ships
Issued 25 June 2018
Resolved
Mark access to the upper deck with the maximum allowable passenger listed on COI.
Action required: 10 - Deficiency Rectified
Due 25 July 2018
Resolved 19 July 2018
Resolution: Attended vessel witnessing appropriate marking provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 June 2018
Resolved
Provide means of closure for penetrations found in watertight bulkheads.
Action required: 10 - Deficiency Rectified
Due 25 July 2018
Resolved 19 July 2018
Resolution: Attended vessel finding all openings adequately plugged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2018
Resolved
Tighten shaft packing to decrease excessive leaking.
Action required: 10 - Deficiency Rectified
Due 25 June 2018
Resolved 19 July 2018
Resolution: Received notification 6/26 that packing gland adjusted with sat results. Completed verification during visit on given date.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 May 2017
Resolved
Found 23 life jackets deteriorated beyond repair. Vessel currently has 113 and is required 128. Vessel is limited to 113 passengers until rectified.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 1 June 2017
Resolution: Vessel owner purchased required number of lifejackets to clear deficiency.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 5 May 2017
Resolved
02 life jakcets needs to be marked with the vessel's name.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 1 June 2017
Resolution: Cleared to the satisfaction of attending marine inspector.
Electrical › Electrical Distribution System (service) › Cable
Issued 5 May 2017
Resolved
Electrical cable in aft void needs metal supports every 24 inches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 1 June 2017
Resolution: Cleared to the satisfaction of attending marine inspector.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 May 2017
Resolved
Replace battery in ring buoy water light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 1 June 2017
Resolution: Cleared to the satisfaction of attending marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 March 2017
Resolved
01 life jacket needs retro material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 1 June 2017
Resolution: Cleared to the satisfaction of attending marine inspector.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 28 June 2016
Resolved
Provide on board Navigation Rules Handbook
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 19 July 2016
Resolution: Navigation Rules Handbook on board.
Fire Fighting › Fire Hoses › Length
Issued 28 June 2016
Resolved
Provide sufficient length of fire hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 19 July 2016
Resolution: Sufficient length of fire hose on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 June 2016
Resolved
Provide all required items for first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 19 July 2016
Resolution: First Aid kit contents sufficient.
Electrical › Electrical Distribution System (service) › Cable
Issued 28 June 2016
Resolved
Properly secure over head wires portside steering void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 19 July 2016
Resolution: Overhead wiring properly secured in Aft Steering space.
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 June 2016
Resolved
Properly support and provide protection for battery cables for engine room battery installations forward and below starboard main diesel engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 19 July 2016
Resolution: Battery cables properly supported and secured.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 June 2016
Resolved
Cap through bulkhead penetration starboard side between engine room and tank space
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 19 July 2016
Resolution: Bulkhead penetration in forward engine room properly closed.