Records from 2016 to 2026. Most recent: inspection, 19 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 May 2026
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:A space with a through-hull fitting below the deepest load waterline, such as a lazarette. Aft steering lazarette found with non-functioning bilge alarm. Repair/replace as required to restore function.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2026
Resolved 28 May 2026
Resolution: alarm functioning as intended.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2026
Resolved
In systems and applications where flexible hoses are permitted to be clamped:(1) Double hose clamping is required where practicable; Main engine jacket water flexible hose found with single clamp. Add additional clamp.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 28 May 2026
Resolution: clamp added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2026
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Lifejacket found with weathered strap which disintegrated upon touch. Replace lifejacket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 28 May 2026
Resolution: Lifejackets replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2026
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Outflowing pipe found uncapped and unsecured with potential to discharge sewage into space. Cap pipe to prevent inadvertent discharge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2026
Resolved 28 May 2026
Resolution: pipe capped.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Cleanliness of engine room
Issued 19 May 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Generator found with loose electrical tape hanging from alternator near running parts and excessive oil and dust accumulation at crankcase ventilation system outlet/inlet. Loose material found in engine room including cardboard boxes,spare lightbulbs, and plastic lube oil jugs. Clean/remove all items above and limit any fire hazards in space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2026
Resolved 28 May 2026
Resolution: Cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 May 2026
Resolved
A vessel on a rivers route must carry: (1) Three hand red flare distress signals, and Three hand orange smoke distress signals
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2026
Resolved 28 May 2026
Resolution: smoke signals replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 May 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: charts and pubs.
Provide charts and pubs for the intended voyage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2026
Resolved 28 May 2026
Resolution: Charts and pubs replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2025
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16) (incorporated by reference; see 46 CFR 175.600). Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. 10 lifejackets found with faded retroreflective tape. 08 found with absent or faded name of vessel. Update tape and names.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 25 November 2025
Resolution: lifejackets renewed with new retro tape and markings.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 13 May 2025
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Loose items, (lightbulbs, small cardboard boxes) found on shelving directly above bilge/fire pump with partially guarded moving machinery components. Relocate loose items away from moving machinery.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 25 November 2025
Resolution: Loose items relocated away from rotating machinery.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
1) Electric control panel adjacent to sewage tank found with exposed wires, where the wire cover had disconnected from connection point at the panel. Re-install cover to panel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 25 November 2025
Resolution: Distribution panel disconnected and removed from vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
Junction box access cover discovered with missing screws, allowing unobstructed access. Crew replaced screws in attendance of marine inspector.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 May 2025
Resolved 13 May 2025
Resolution: Crew reinstalled screws and secured box.
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 6 May 2024
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited, the operator must secure each type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include-
1) Closing each valve leading to an overboard discharge and removing the handle;
2) Padlocking each valve leading to an overboard discharge in the closed position; or
3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2024
Resolved 11 June 2024
Resolution: discharge secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2024
Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. Multiple wire connections were made not within a junction box above sewage tank and at overhead just aft of sewage tank.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2024
Resolved 11 June 2024
Resolution: wires removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2023
Resolved
Upon testing, found water leaking through surface cracking on the hose. Replace in kind.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 June 2023
Resolution: Fire hose replaced and tested by crew.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 May 2023
Resolved
Fire servicing company notated that the flex hoses on CO2 system are overdue for hydrostatic testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 June 2023
Resolution: Recieved fire servicing report attesting to replacement of flex hoses
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 May 2023
Resolved
Clean engine room bilge and ensure presence and condition of strainer. Test operation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2023
Resolution: Strainer has been replaced and operationally tested by crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 May 2023
Resolved
Replace rubber flex hose connected to the radiator due to presence of dry rot.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2023
Resolution: Hose's were renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 May 2022
Resolved
The bilge pump piercing the collision bulkhead shall be fitted with a screw down valve. Reach rod for remote closure is broken.
46 CFR 182.25-5(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 August 2022
Resolution: Owner attested to having repaired the screw down valve.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 May 2022
Resolved
a visual and audible alarm must be provided at the operation station to indicate high water in the machinery space. Light and alarm are not functioning properly.
46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 August 2022
Resolution: Owner attested to having repaired the bilge alarm.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 May 2022
Resolved
Emergency escape hatch in engine room should be marked in a readily apparent manner. Marking is not adequate.
46 CFR 177.500
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2022
Resolution: Owner sent picture of engine room escape hatch clearly marked in red letters with reflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2022
Resolved
PFD's stowed overhead must allow for quick release by person on deck. The pull string is not adequate.
46 CFR 180.78(a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2022
Resolution: Owner sent pictures of long pull string installed on release mechanism for PFDs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2022
Resolved
Each container for PFDs must be labeled with numbers. PFD overhead stowage not marked with number of PFDs.
46 CFR185.604(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2022
Resolution: Lifejacket stowage locations are labeled with the number of PFD's stowed there.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 May 2022
Resolved
Provide approved bracket for fire extinguisher located on forward main deck and concession stand. (reissue from last year)
46 CFR 182.530(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2022
Resolution: Owner stated that Vanguard delivered 02 brackets for fire extinguishers to be installed today.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2022
Resolved
Connections must be made to battery terminals with permanent type connectors. Temporary connections and spring clips are not allowed. 46 CFR 183.350
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2022
Resolution: Owner sent a photo of proper battery connections. All temporary clips have been removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2022
Resolved
Hazardous and flammable liquids are not properly stowed to prevent ignition of flammable vapors.
46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2022
Resolution: Flammable liquids have been removed from the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2022
Resolved
Grab lines on ring lifebuoy shall be IAW 46 CFR 160.050. Not secured at becketts
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2022
Resolution: Owner sent photo of new grab lines installed at the beckets for 02 life buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2022
Resolved
Battery in floating electric water light is not an approved type.
46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2022
Resolution: Ownew provided attestation that the battery installed is approved by the manufacturer and provided documentation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2022
Resolved
All lifesaving appliances shall be in good working order. Replace 02 liferings. 46 CFR 180.70(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2022
Resolution: 02 life buoys were removed from the vessel. Vessel still meets the requirement of having 02 lifebuoys.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2022
Resolved
Service leaking shaft seal and rudder post
46 CFR 182.200
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 May 2022
Resolution: Seal has been serviced and tightened. Owner sent video of reduced dripping.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 28 April 2021
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons overboard. Abandon ship and man overboard drills and training shall be logged for review by the USCG including the date and general description of the drill/training. Drills were not carried out as required or logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 20 May 2021
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 April 2021
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire and shall be logged or documented for review by the USCG including date and general description of the drill and training topics. Drills were not carried out or logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 20 May 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 April 2021
Resolved
A vessel must carry a first-aid kit approved under approval series 160.041 or kit with equivalent contents and instructions. For equivalent kits, contents must be stowed in a suitable, watertight container marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Contents expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 20 May 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 28 April 2021
Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Two supply ducts were located on each side of the pilot house with no means of closure. Provide.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 20 May 2021
Resolution: Temporary closure provided. Vessel to provide more effective means of closure at next dry dock.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 April 2021
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a non watertight closure, such as a space with a non watertight hatch on the main deck. No high level alarm is installed in the fuel tank space, or in the fresh water/waste water space. Ensure spaces are made watertight or install high level alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 20 May 2021
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 28 April 2021
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. Installation must be to the satisfaction of the OCMI. Provide an approved bracket for the fire extinguisher at the concession stand.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 20 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2021
Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than 3x the area of the bilge pipe. Install strainer in forepeak space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 20 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2020
Resolved
A vessel must have one or more life buoys with a buoyant lifeline, 60' in length, non kinking, dark color if synthetic and a floating water light attached around the body of the life buoy with a 3-6' lanyard and corrosion resistant clip. Life line was deteriorating and incorrectly connected to life buoy. Water light was incorrectly secured. Provide correct installation/line.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 17 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2020
Resolved
Stowage of life jackets if stowed above 7 feet above deck must have a means for quick release and be capable of operation by a person standing on the deck. Stowage shall be labeled for quick release.
Vessel to install a pull cord handle for quick release.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2021
Resolved 28 April 2021
Resolution: Lifejackets are now stowed with a quick release knot. Directed owner to place red plastic pull handle on the line for visibility, improve marking, and ensure knot is in a quick release manner at all times.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2020
Resolved
Fuel shutoff valves must be fitted at the tank connection. Starboard side reach rod disconnected and is not functioning. Vessel shall repair the reach rod.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 17 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 June 2020
Resolved
A hatch on a vessel that operates only on protected waters must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains or other devices of substantial strength to prevent its loss. Hatch covers shall be secured and attached to the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2021
Resolved 28 April 2021
Resolution: Verified captive chains have been installed on each hatch cover.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 June 2020
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Aft bulkhead of engine room found to have a copper tube going through the bulkhead with no collar and not watertight. Properly fit with collar and make water tight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2021
Resolved 20 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 June 2020
Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of the Navigation Rules. Navigation Rules was not on board the vessel. Navigation Rules shall be provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 27 October 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2020
Resolved
Vessel must have visual and audible alarm for bilge high level at operating station. A space with non-watertight closures on the main deck must be fitted with bilge alarm. Bilge alarm not properly functioning. Vessel shall prove proper function of bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 17 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2020
Resolved
Vessel must meet the minimum number of extinguishers required per Table 181.500(b). Vessel is missing extinguisher for Concession stand (2-A) and has incorrect extinguisher for main deck accommodation space, have 10-B:C need 2-A. Vessel shall provide correct extinguishers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 17 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 May 2019
Resolved
Engine room bilge alarm not sounding at operating station. Vessel shall repair audio E-room bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2019
Resolved 28 April 2021
Resolution: satisfactorily tested bilge alarm
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 31 May 2019
Resolved
Provide engine room vent closure
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2019
Resolved 15 June 2020
Resolution: Closure for vent provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2019
Resolved
Replace 03 adult lifejackets, and renew retro tape on 05 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2019
Resolved 15 June 2020
Resolution: Lifejackets renewed with new retro tape.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 May 2019
Resolved
Remove all rust and scale in CO2/sewage space IWO first 3 bays along keel and paint/protect area.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2019
Resolved 15 June 2020
Resolution: Area cleaned/painted as required.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 May 2018
Resolved
Properly serarate and mark Adult and Child size lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 20 June 2018
Resolution: Visited vessel and cleared requirment.
Engineering › Bilge Water Management System › Strainer
Issued 25 April 2017
Resolved
Replace fractured bilge line strainer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 26 May 2017
Resolution: Inspected new strainer.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 April 2017
Resolved
Provide service receipts for annual prior to passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 23 May 2017
Resolution: Annual fire service reports received.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 April 2017
Resolved
Aft compartment high bilge level alarm is not indicating on the bridge at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 26 May 2017
Resolution: Witnessed test of bilge alarm.
Communications › Alarms/Indicators › High Water Alarm
Issued 29 April 2016
Resolved
Hi level alarms are inidicating both spaces simultaneously within the pilot house. Make permanent repairs to the system to indicate individual alarms.
Condition: Improper Installation
Due 1 June 2016
Resolved 1 June 2016
Resolution: Hi bilge water alarms repaired to indicate individual spaces.
Lifesaving › Lifefloat › Serviceable
Issued 29 April 2016
Resolved
Vessel has changed service and the lifefloats are unserviceable due to material condition. Remove from vessel prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 19 May 2016
Resolution: Lifefloats removed from vessel.
Lifesaving › Lifebuoys › Serviceable
Issued 29 April 2016
Resolved
Remove two liferings which are split and unserviceable and renew with approved rings.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 19 May 2016
Resolution: Liferings and line and light renewed.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 29 April 2016
Resolved
Lifejacket stowage is mis-marked and mixed with child and adult jackets. Ensure seperate correct stowage and marking on stowage locations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 19 May 2016
Resolution: Stowage properly marked and child and adult jackets seperated.