Records from 1995 to 2026. Most recent: inspection, 15 June 2026.
Inspection history · 40
15 June 2026
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8404956
1 January 2026
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8289003
12 November 2025
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8266609
23 April 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8118050
2 April 2025
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8103812
1 April 2025
PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8100814
11 August 2023
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7763967
8 April 2023
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664905
7 April 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664663
26 October 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7584214
11 September 2022
PSC B · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7553694
12 August 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7531467
6 July 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7498913
12 April 2022
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7428754
23 September 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7318682
13 July 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7254710
13 July 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7254873
3 June 2021
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7214188
27 April 2021
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7183191
9 August 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6505411
6 July 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6469414
23 June 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6452774
3 February 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6348961
6 December 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6317014
25 November 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6312469
30 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6297728
3 June 2017
Deficiency Check · Administrative Inspection · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6164063
24 July 2012
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4388783
27 September 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4155820
30 July 2005
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2445344
20 December 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 435918
8 July 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 430396
16 December 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 423738
1 December 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 423239
4 September 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 395052
5 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 121025
18 June 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 169039
9 February 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 387714
31 August 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 382199
22 August 1995
Type not recorded
No type recorded · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1398332
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2025
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed several deadend wires, exposed wires, missing housing, and spliced wires throughout engine room, machinery spaces, and deck passage ways.
74SOLAS(04)
II-1/45.1.3
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2025
Resolved 2 April 2025
Resolution: Conducted in-person Def Check. Received [name withheld] attesting to repairs (see documents). Cleared 01 deficiency from Sector Jacksonville/CASE #8100814/01APR25/DEF01. MISLE 8103812
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 11 September 2022
Resolved
Any main and auxiliary steering gear control system operable from the navigation bridge shall comply with the following: (.4) in the event of a failure of the electrical power supply to the control system, and audible and visual alarm shall be given on the navigation bridge. During pre-arrival testing the crew discovered the steering gear alarm was not activated on the bridge or in the engine room.
74SOLAS(04 CONS.) II.1/29.8.4 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 October 2022
Resolution: Received class report attesting to repairs made for steering gear alarms. Class report located in documents.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 September 2022
Resolved
Every ship shall be provided with: (.1) a VHF radio installation capable of transmitting and receiving. The vessel's VHF No. 1 is currently malfunctioning and inoperable.
74SOLAS(20)IV/7.1.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 October 2022
Resolution: Received class report attesting to replacement of VHF radios. Class report located in documents.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 August 2022
Resolved
AT LEAST THREE TWO-WAY VHF RADIOTELEPHONE APPARATUS SHALL BE PROVIDED ON EVERY CARGO SHOP AT 500 GROSS TONNAGE AND UPWARDS. SUCH APPARATUS SHALL CONFORM TO PERFORMANCE STANDARDS NOT INFERIOR TO THOSE ADOPTED BY THE ORGANIZATION. TWO PORTABLE VHF BATTERIES ARE EXPIRED.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2022
Resolved 12 August 2022
Resolution: Class survey report attested that replacements would be mandated on august 31st.
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 12 August 2022
Resolved
AT LEAST ONE RADAR TRANSPONDER SHALL BE CARRIED ON EACH SIDE OF EVERY CARGO SHIP OF 500 GROSS TONNAGE AND UPWARDS. SICH RADAR TRANSPONDERS SHALL CONFORM TO PERFORMANCE STANDARDS NOT INFERIOR TO THOSE ADOPTED BY THE ORGANIZATION. BATTERY IN BRIDGE SART IS EXPIRED.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2022
Resolved 12 August 2022
Resolution: Class survey report attested that replacements would be mandated on august 31st.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 April 2022
Resolved
Any required automatic sprinkler, fire detection and fire alarm system shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation.
PSCO observed smoke detector in purifier room to be not operational. Detectors are to be capable of immediate operation at all times with no action by the crew necessary.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 15 April 2022
Resolved 26 May 2022
Resolution: Received class report attesting to the repair of the smoke detector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 July 2021
Resolved
MAIN ENGINE LOST ASTERN PROPULSION DUE TO ENGINE OPERATING IN DEAD SLOW TOO LONG
Action required: 60 - Rectify deficiencies prior to movement
Due 13 July 2021
Resolved 13 July 2021
Resolution: SEE CLASS REPORT
Electrical › Electric Supply System (service) › Cable
Issued 3 June 2017
Resolved
All electrical apperatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. There are numerous open ended wires and juction boxes on the bridge. 74SOLAS(97)II-1/45.1.3 40AC
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 June 2017
Resolved 5 June 2017
Resolution: PSC HOU received class report.
Fire Fighting
Issued 1 December 1998
Resolved
VESSEL MISSING 2 ADDITIONAL SCVA'S REQUIRED FOR VESSEL CARRYING DANGEROUS CARGO.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Construction/Loadline
Issued 4 September 1996
Resolved
MARK LOADLINE MARKINGS IN PERMANENT CONTRASTING COLOR TO THE HULL._x001C_ ICLL 66 ANNEX I/9
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Documentation
Issued 4 September 1996
Resolved
PROVIDE THIRD MATE WITH HAZARDOUS MATERIALS TRAINING._x001C_ 49CFR 172.702(a)
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998