Records from 1985 to 2007. Most recent: inspection, 14 December 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 43
14 December 2007
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3115918
1 March 2006
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2593935
21 June 2005
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2440618
14 May 2004
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2064069
13 May 2003
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1792419
12 February 2003
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1742571
24 June 2002
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1646959
17 June 2002
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1632428
3 April 2002
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1627819
6 November 2001
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1366661
2 April 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1489102
26 January 2001
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1366207
5 September 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1469034
19 March 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1410376
9 March 2000
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 817525
25 August 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 779703
10 August 1999
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1510049
18 June 1999
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1415311
22 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1122689
22 July 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427552
29 April 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 789439
11 March 1998
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 788995
11 June 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1113588
28 May 1996
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084685
24 April 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1081058
13 November 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182458
5 July 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186149
10 May 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326683
3 May 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 862573
28 May 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152012
2 November 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258506
20 May 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1269780
16 May 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220377
10 May 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220540
30 May 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242747
21 July 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1041691
18 May 1987
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1019040
30 April 1987
COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1328459
5 November 1986
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1009473
13 August 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1003243
21 April 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1307370
2 July 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1291888
13 May 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 980558
Construction/Loadline › Penetrations › Pipe Flange
Issued 21 June 2005
Resolved
Blank off all unused thru-hull fittings to the satisfaction of the attending marine inspector.
Due 21 June 2005
Resolved 22 June 2005
Engineering › Steering Gear System › Rudder Bearing
Issued 21 June 2005
Resolved
Repair or renew cracked rudder bearing assembly to the satisfaction of the attending marine inspector.
Due 15 October 2005
Resolved 21 June 2005
Construction/Loadline › Hull › Transverse Frame
Issued 21 June 2005
Resolved
Renew wasted transverse frame bottom sections in way of forepeak and passenger accommodation areas to the satisfaction of the attending marine inspector.
Due 15 October 2005
Resolved 21 June 2005
Construction/Loadline › Hull › Transverse Frame
Issued 21 June 2005
Resolved
Replace wasted fasteners as marked by inspector.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 21 June 2005
Construction/Loadline › Hull › Keel
Issued 21 June 2005
Resolved
Renew deteriorated worm shoe as original to the satisfaction of the attending marine inspector.
Due 15 October 2005
Resolved 21 June 2005
Communications › Radio Communications
Issued 14 May 2004
Resolved
Provide EPIRB IAW 46 CFR 185.720. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2004
Resolved 27 May 2004
Resolution: EPIRB installed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 May 2004
Resolved
Renew retro tape on 11 life jackets. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2004
Resolved 27 May 2004
Resolution: Retro tape renewed.
Lifesaving › Hand Flares
Issued 14 May 2004
Resolved
Provide 3 additional hand held flares IAW 46 CFR 185.614.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2005
Resolved 27 May 2004
Resolution: Flares provided.
Engineering › Fuel Oil Service System
Issued 14 May 2004
Resolved
Repair and demonstrate F/O shut off valves. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2004
Resolved 27 May 2004
Resolution: Valve repaired and demonstrated.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 14 May 2004
Resolved
Install machinery guards on main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2004
Resolved 27 May 2004
Resolution: Guards installed.
Operations/Management
Issued 14 May 2004
Resolved
Provide Navigation Pubs Light list, Coast Pilot, Tides and currents.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2004
Resolved 27 May 2004
Resolution: Pubs provided.
Communications › Radio Communications
Issued 14 May 2004
Resolved
Provide FCC operators permit prior to operating beyond 1000 feet from shore. LEGACY COMPONENT DESC: VHF Radiotelephone
Action required: 705 - Other - as specified
Due 14 June 2004
Resolved 27 May 2004
Resolution: Operators permit provided.
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 May 2004
Resolved
Provide first aid/CPR cards for 50% of the crew.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2004
Resolved 27 May 2004
Resolution: CPR first aid cards provided.
Construction/Loadline › Hull
Issued 12 February 2003
Resolved
Renew floor plank in FWD cabin deck stbd side IWO ladder.
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 3 April 2003
Resolution: Owner renewed floor plank in FWD cabin deck stbd side IWO ladder.
Construction/Loadline › Hull
Issued 12 February 2003
Resolved
Renew rotted wood stbd side fwd cabin corners and top planking fwd of access.
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 3 April 2003
Resolution: Owner renewed rotted wood stbd side fwd cabin corners and top planking fwd of access.
Construction/Loadline › Hull
Issued 12 February 2003
Resolved
Renew rotted wood aft cabin port and stbd side, exterior.
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 3 April 2003
Resolution: Owner renewed rotted wood aft cabin port and stbd side, exterior.
Construction/Loadline › Hull
Issued 12 February 2003
Resolved
Renew soft deck stbd side 15' fwd of stern.
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 3 April 2003
Resolution: Owner renewed soft deck stbd side 15'' fwd of stern.
Accommodation/Occupational Safety › Occupational Safety
Issued 12 February 2003
Resolved
Add 4" mesh rails IWO existing rail courses IAW 46 CFR 177.900. LEGACY COMPONENT DESC: Deck Rail
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2003
Resolved 13 May 2003
Resolution: Owner added 4" mesh rails IWO existing rail courses.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 12 February 2003
Resolved
Service all portable and fixed fire extinguishers. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2003
Resolved 13 May 2003
Resolution: Owner serviced all portable and fixed fire extinguishers.
Documentation
Issued 6 November 2001
Resolved
PROVIDE FCC STATION LICENSE IAW 47 CFR PART 80.
Condition: Unknown
Due 6 December 2001
Resolved 3 April 2002
Resolution: Owner provided FCC Station License.
Lifesaving
Issued 6 November 2001
Resolved
PROVIDE WATER LIGHT FOR LIFE RING IAW 46 CFR 180.70 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 December 2001
Resolved 3 April 2002
Resolution: Owner provided waterlight for lifering.
Documentation
Issued 6 November 2001
Resolved
PROVIDE FCC SAFETY CERTIFICATE IAW 47 CFR PART 80.
Condition: Unknown
Due 6 December 2001
Resolved 3 April 2002
Resolution: Owner provided FCC Safety Certificate.
Construction/Loadline
Issued 6 November 2001
Resolved
RENEW BILGE HOSE WITH APPROVED FLEXABLE HOSE IAW 46 CFR 182.710.
Condition: Unknown
Due 6 December 2001
Resolved 3 April 2002
Resolution: Owner renewed bilge hose with approved type.
Electrical
Issued 6 November 2001
Resolved
REMOVE WIRE NUTS IN PILOT HOUSE IAW 46 CFR 183.340.
Condition: Unknown
Due 6 December 2001
Resolved 3 April 2002
Resolution: Owner replaced wire nuts with approved butt connectors.
Navigation
Issued 6 November 2001
Resolved
PROVIDE NAVIGATION PUBLICATIONS (COAST PILOT, CG LIGHT LIST, TIDES AND CURRENTS TABLE) IAW 46 CFR 184.420
Condition: Unknown
Due 6 December 2001
Resolved 3 April 2002
Resolution: Owner provided appropriate Nav Pubs.
Electrical › Electrical Distribution System (service)
Issued 26 January 2001
Resolved
RENEW CIRCUIT BREAKER PANEL LOCATED IN FOREWARD ACCOMMODATION SPACE BERTHING UNDER LADDER. NEW ELECTRICAL DISTRIBUTION SHALL BE INSTALLED IN ACCORDANCE WITH 46 CFR 183.340 LEGACY COMPONENT DESC: Panelboard
Due 26 February 2001
Resolved 2 April 2001
Resolution: Examined newly installed electrical distribution panel. Panel installation in accordance with 46 CFR 183.340.
Electrical › Electric Supply System (service)
Issued 26 January 2001
Resolved
PROPERLY SUPPORT ELECTRICAL CABLES WITH METAL STRAPS THROUGHOUT VESSEL AS PRESCRIBED BY 46 CFR 183.340. LEGACY COMPONENT DESC: Cable
Condition: Unknown
Due 26 February 2001
Resolved 2 April 2001
Resolution: Examined and found satisfactory all electric cable supports in accordance with 46 CFR 183.340.
Electrical › Electrical Distribution System (service)
Issued 26 January 2001
Resolved
REMOVE DEAD END CABLES THROUGHOUTVESSEL. LEGACY COMPONENT DESC: Cable
Due 26 February 2001
Resolved 2 April 2001
Resolution: All dead ended electrical cables were removed and or terminated at the electrical suppy source.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 26 January 2001
Resolved
SERVICE FIXED AND PORTABLE FIRE EXTINGUISHERS AS REQUIRED BY 46 CFR 176.810. LEGACY COMPONENT DESC: Service
Due 26 February 2001
Resolved 26 January 2001
Resolution: Sighted fire extinguisher servicing report. All fire extinguishers in satisfactory condition.
Accommodation/Occupational Safety › Occupational Safety
Issued 26 January 2001
Resolved
Provide proposal to make deck rails compliant with 46 CFR 177.900(g)(1). LEGACY COMPONENT DESC: Deck Rail
Due 26 February 2001
Resolved 2 April 2001
Engineering › Bilge Water Management System › Pump
Issued 26 January 2001
Resolved
REPAIR FOREWARD BILGE PUMP AND FLOAT SWITCH.
Due 26 February 2001
Resolved 26 January 2001
Resolution: Witnessed satisfactory operation forward bilge pump.
Electrical › Electrical Distribution System (service)
Issued 26 January 2001
Resolved
RENEW ELECTRICAL DISTRIBUTION PANEL IN ENGINEROOM. THE NEW DISTRIBUTION PANEL SHALL MEET THE REQUIREMENTS SETFORTH IN 46 CFR 183.340. LEGACY COMPONENT DESC: Panelboard
Due 26 February 2001
Resolved 2 April 2001
Resolution: Examined and found satisfactory newly installed electrical distribution panel in accordance with 46 CFR 183.340.
Construction/Loadline › Hull
Issued 26 January 2001
Resolved
Renew eighty internal frame fastners as identified by the attending U.S. Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Fastners
Due 26 January 2001
Resolved 26 January 2001
Resolution: Examined installation of 80 fasteners throughout the vessel bottom and side frames
Construction/Loadline › Structures
Issued 26 January 2001
Resolved
Renew rotted wood deck planking and shear clamp as original to the satisfaction of the attending U.S. Coast Guard marine inspector. LEGACY COMPONENT DESC: Deck Planking
Due 26 January 2001
Resolved 26 January 2001
Resolution: All rotten deck planking and shear clamp in way of deck planking was renewed as original.
Construction/Loadline › Hull
Issued 26 January 2001
Resolved
Renew transverse frame attachment fastners to side shell stiffners to the satisfaction of the attending U.S. Coast Guard marine inspector. LEGACY COMPONENT DESC: Framing Fastners
Due 26 January 2001
Resolved 26 January 2001
Resolution: Al fasteners were renewed as original.
Construction/Loadline › Hull
Issued 26 January 2001
Resolved
Renew plank fasteners to tranverse stiffners to the satisfaction of the attending U.S. Coast Guard marine inspector. LEGACY COMPONENT DESC: Hull Planking Fastners
Due 26 January 2001
Resolved 26 January 2001
Resolution: All plank fastners were renewed as original as directed by the attending marine inspector.
Electrical › Electric Supply System (service)
Issued 26 January 2001
Resolved
Provide and install battery box cover to battery installation as required by 46 CFR 183.354. LEGACY COMPONENT DESC: Battery Installation
Due 2 April 2001
Resolved 2 April 2001
Resolution: Examined and found satisfactory newly installed battery box cover.
Lifesaving
Issued 11 June 1997
Resolved
Label lifejacket locker with qty and type of lifejacket.
Condition: Unknown
Due 27 June 1997
Resolved 1 July 1997
Unknown
Issued 11 June 1997
Resolved
Prove compliance with Drug & Alcohol program.
Condition: Unknown
Due 27 June 1997
Resolved 1 July 1997
Lifesaving
Issued 11 June 1997
Resolved
Stencil B/A in 2" letters with name of vessel and qty of persons & coil painter line so it won't tangle.
Condition: Unknown
Due 27 June 1997
Resolved 1 July 1997
Lifesaving
Issued 11 June 1997
Resolved
Lag exposed section of main engine exhaust.
Condition: Unknown
Due 27 June 1997
Resolved 1 July 1997
Unknown
Issued 28 May 1996
Resolved
PROVIDE PROOF OF COMPLIANCE WITH CREW TRAINING IAW 46 CFR 185.420
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Navigation
Issued 28 May 1996
Resolved
PROVIDE UP TO DATE CHARTS OF OPERATING AREA.
Condition: Unknown
Due 15 June 1996
Resolved 2 June 1996
Unknown
Issued 28 May 1996
Resolved
PROVIDE PROFF OF COMPLIANCE OF EMERGENCY DRILLS IAW 46 CFR 185.520 & 185.524
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 28 May 1996
Resolved
PROVIDE WATER LIGHTS FOR 3 B/A'S TO FLOAT FREE IAW 46 CFR 180.175(d) & 180.175(e)(4). VESSEL RESTRICTED TO DAYLIGHT OPS UNTIL INSTALLED
Condition: Unknown
Due 15 June 1996
Resolved 2 June 1996
Construction/Loadline
Issued 24 April 1996
Resolved
REPAIR DECK BEAM STBD SIDE AT TRANSOM
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Electrical
Issued 24 April 1996
Resolved
REMOVE ALL DEAD END CABLES
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Construction/Loadline
Issued 24 April 1996
Resolved
REPAIR FRAME #7 FWD STBD SIDE IN FWD COMPARTMENT IWO KEEL
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Accommodation/Occupational Safety
Issued 28 May 1993
Resolved
REPLACE DOG ON THE PORTLIGHT. PROVIDE PROOF OF BEFORE AND AFTER PICTURE FORITEMS 2 & 3._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Unknown
Issued 28 May 1993
Resolved
PROVIDE PROOF OF CHEMICAL DRUG TESTING. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Construction/Loadline
Issued 28 May 1993
Resolved
SEAL HOLES IN ENGINEROOM BULKHEAD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Deck/Cargo
Issued 10 May 1991
Resolved
PROVE PROPER OPERATION OF WINDLASS.
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Navigation
Issued 5 November 1986
Resolved
REPLACE THE MASTHEAD LIGHT AND STERN LIGHT WITH LIGHTS WHICH MEET THE REQUIREMENTS OF THE 72/77 COLREGS.
Condition: Unknown
Due 5 November 1986
Resolved 5 November 1986
Electrical
Issued 5 November 1986
Resolved
THE 110 VAC GENERATOR HAS NO CYCLES METER OR AMPERAGE METER, INSTALL SAME.
Condition: Unknown
Due 5 November 1986
Resolved 5 November 1986