MAURY USCG vessel records Sign in
← All vessels

SASHIMI

SASHIMI is a 1954 passenger vessel (uninspected). The Coast Guard has recorded 93 inspections since 1985, most recently in December 2024, along with 193 deficiencies, 1 operational control and 4 casualty investigations between 2007 and 2023.

Records from 1985 to 2024. Most recent: inspection, 5 December 2024.

Built
1954
Last inspected
5 December 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH4759
Flag
UNITED STATES
367033710, 367621080 (licence lapsed)
Maury page id
psix-42946

Inspections, by type

…with no type recorded13
Years with a record 38 calendar years (1985–2024)
The 93 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)37.4 ft × 13.9 ft × 4.3 ft
Registered tonnagegross 20 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFRIES BOATS · VENICE, CA, UNITED STATES · built 1954
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsRecreational
DocumentationValid · issued 13 June 2024 · expires 30 June 2029
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH4759MMSI 367621080 · expired · compulsorily equipped · granted 14 May 2014, cancelled 20 July 2024
WAL7157MMSI 367033710 · expired · compulsorily equipped · granted 14 April 2005, cancelled 25 July 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GREAT ESCAPE Passenger (Inspected) · MISLE 48706 · 23 June 2007 · activity 3013598

Inspection history · 93

5 December 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8046300
4 August 2023 Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7760447
4 August 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7764122
6 June 2023 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7702270
6 March 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7646328
2 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7442683
30 March 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7165828
9 December 2020 Deficiency Check · Drydock Exam · Plan Review "T" Boat · Drydock Extension · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7109030
30 September 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7069000
13 May 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6951662
21 October 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6838995
11 April 2019 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6660308
26 November 2018 Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6587049
6 April 2018 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6386481
16 November 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6306666
23 August 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6251608
23 August 2017 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6254839
2 May 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6137175
29 August 2016 Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5986713
29 August 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5986915
5 May 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5869541
3 December 2015 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5774571
24 March 2014 Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4821833
7 May 2012 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4304833
26 August 2011 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4125966
27 July 2009 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3526868
7 May 2009 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3459967
7 August 2008 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3286274
23 April 2008 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3289811
23 June 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3013598
23 June 2007 Examination of Repairs · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3021787
8 May 2007 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2910318
3 May 2007 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2910322
27 April 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2616439
3 May 2005 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2337716
3 March 2005 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2293843
19 July 2004 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2138165
14 July 2004 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2133255
26 April 2004 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2020503
22 April 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1774380
3 March 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1752168
6 June 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1627437
22 April 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1607815
31 January 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1483147
13 July 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1067255
24 April 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1382295
12 March 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1471758
28 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 156168
2 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1384815
28 April 2000 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1366098
28 April 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1430912
30 August 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 664111
21 May 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 798672
23 April 1999 Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375730
21 April 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 214180
21 April 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1372600
19 April 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 216273
18 February 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 797961
24 November 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 805327
1 May 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1461046
14 April 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1388524
26 January 1998 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 791246
15 April 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1374947
7 November 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1371576
16 April 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1355774
1 June 1995 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 873715
19 April 1995 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1377408
11 May 1994 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1171669
19 April 1994 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1426899
1 April 1994 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1385213
4 May 1993 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1425327
31 March 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1133369
12 May 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 954312
22 April 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1259392
11 December 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1261056
4 December 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 937663
12 July 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1247555
13 June 1991 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1024575
20 May 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1217852
11 July 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 933601
6 June 1990 Hull Examination · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1215658
24 May 1990 Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 919276
13 February 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 913990
25 January 1990 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1220696
31 May 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1041161
30 May 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1035777
8 June 1988 Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1201629
17 December 1987 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1313945
29 May 1987 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1027390
3 June 1986 Deficiency Check · Credit Drydock
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1294559
29 May 1986 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1294705
27 January 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1297709
4 June 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1288060

Deficiency record · 193

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 December 2024 Resolved
Vessel was discovered to have a COI overdue for its annual inspection. To maintain a valid COI, the vessel must complete its annual inspection within 3 months of the anniversary date. Vessel is restricted from carrying passengers for hire until it completes a satisfactory annual inspection.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 December 2024
Resolution: Cleared def because vessel surrendered COI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 August 2023 Resolved
Identify source of flooding and provide a repair plan for OCMI approval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2023
Resolution: Source of flooding was a broken hose clamp on raw water inlet hose for the MDE. Clamp has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2023 Resolved
Troubleshoot all engine room and lazarette equipment to identify potential damage and electrical hazards caused by flooding incident. Following successful troubleshooting, call out USCG marine inspector to witness operational test of equipment. Cites: 46 CFR 176.830; 46 CFR 176.804.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2023
Resolution: Witnessed satisfactory operational test of equipment.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 August 2023 Resolved
Repair forward bilge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2023
Resolved 24 January 2025
Resolution: Closing out deficiency since vessel no longer operates under a COI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2023 Resolved
Water was found dripping from the hatch over the battery boxes and reached the battery tops via cutouts in the battery box lid. Remove water from battery box and clean battery terminals. Modify battery box to free batteries from exposure to water splash and spray.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 24 January 2025
Resolution: Closing out deficiency since vessel no longer operates under a COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 August 2023 Resolved
Provide shaft seal with double hose clamps on each end.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2023
Resolved 24 January 2025
Resolution: Closing out deficiency since vessel no longer operates under a COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2023 Resolved
Renew all hose clamps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 24 January 2025
Resolution: Closing out deficiency since vessel no longer operates under a COI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 August 2023 Resolved
Clean excess oil and coolant from bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2023
Resolved 24 January 2025
Resolution: Closing out deficiency since vessel no longer operates under a COI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2023 Resolved
Mount all electrical wires as high above the bilge as practicable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2023
Resolved 24 January 2025
Resolution: Closing out deficiency since vessel no longer operates under a COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2023 Resolved
Add chaffing gear on the two identified fuel hoses touching portside engine mounts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2023
Resolved 24 January 2025
Resolution: Closing out deficiency since vessel no longer operates under a COI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2023 Resolved
Remove dead-end wire from 12v panel on starboard side of engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2023
Resolved 24 January 2025
Resolution: Closing out deficiency since vessel no longer operates under a COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 August 2023 Resolved
Non-metallic hose on wet exhaust system found leaking from both ends. Repair/replace the identified hose to prevent excess leaking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2023
Resolved 24 January 2025
Resolution: Closing out deficiency since vessel no longer operates under a COI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 August 2023 Resolved
Aft bulkhead in engine room has several large unsealed penetrations within a foot of the bilge. Seal identified bulkhead penetrations to satisfaction of attending USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 August 2023
Resolution: Received photos of the holes sealed with marine grade plywood, stainless steel screws, and sealant.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 June 2023 Resolved
All vessels operating on a Coastwise or Oceans route must have fire detection systems in accordance with 46 CFR 181.405 and 46 CFR 181.450. Vessel is restricted to Lakes,Bays and Sounds/Limited Coastwise route until fire detection system is installed to the satisfaction of the USCG.
Action required: 705 - Other - as specified
Resolved 13 July 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 6 June 2023 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Must provide proof of enrollment of random drug testing program of crewmembers to the satifaction of the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 13 July 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2023 Resolved
A vessel not required to have a power driven fire pump by 46 CFR 181.300 must have at least three 2.5 gallon buckets, with an attached lanyard with the words "FIRE BUCKET" stenciled in a contrasting color on each bucket. Must provide proof of obtaining buckets to the satisfaction of the USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 13 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 June 2023 Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. Must provide proof of ownership to satisfaction of USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 13 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 May 2022 Resolved
VESSELS REQUIRED SURVIVIAL CRAFT IS NOT CURRENTLY ONBOARD. VSL ROUTE IS REDUCED FROM COASTWISE TO LIMITED COASTWISE TO NOT EXCEED 3 MILES FROM SHORE UNTIL THE REQUIRED CRAFT IS RE-INSTALLED ONBOARD AND VERIFIED BY A MARINE INSPECTOR.
Action required: 705 - Other - as specified
Resolved 6 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 2 May 2022 Resolved
VSL SSDG DOES NOT HAVE A GUARD INSTALLED AROUND SERPENTINE BELT. FAB/PROCURE AND INSTALL FOR PERSONNEL PROTECTION.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 June 2022
Resolution: Guard installed verified by MI
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 March 2021 Resolved
Replace wasted life ring. Due 30Apr2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 8 April 2021
Resolution: Replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 30 March 2021 Resolved
Replace missing dog on port side machinery space hatch. Due 30Apr2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 8 April 2021
Resolution: Dog installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 March 2021 Resolved
Replace missing clamp on main engine heat exchanger. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 30 March 2021
Resolution: Clamp installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 30 March 2021 Resolved
MMC not signed. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 30 March 2021
Resolution: Signed.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 30 March 2021 Resolved
EPIRB hydrostatic release not permanently etched. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 30 March 2021
Resolution: Etched.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2020 Resolved
Provide repair plan for holed port side fuel tank. Plan shall include diagrammatic representation of tank repair, replacement plate and filler material in accordance with 46CFR182.440, weld process, and nondestructive testing. Due prior to the carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2021
Resolution: Fuel tank repaired, hydro complete, tank installed, deck repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2020 Resolved
Provide a valid FCC Safety Radiotelephony certificate. Vessel is restricted to not more than 1000 feet from shore until this deficiency is corrected.
Action required: 705 - Other - as specified
Due 12 June 2020
Resolved 14 May 2020
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 13 May 2020 Resolved
Provide a ship specific emergency instruction list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 15 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 May 2020 Resolved
Vessel's inflatable buoyant apparatus (IBA) was unable to be serviced by its due date of April 30th, 2020 due to the lack of available servicing facilities caused by the COVID-19 pandemic. Vessel's IBA must be serviced by 30 September, 2020.
Action required: 705 - Other - as specified
Due 30 September 2020
Resolved 30 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2019 Resolved
Provide operational waterlights for all PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2019
Resolved 12 April 2019
Resolution: Ligths provided for all PFD's.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 April 2019 Resolved
Install correct stern light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2019
Resolved 12 April 2019
Resolution: New proper stern light installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 April 2019 Resolved
Make port nav light operational.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 12 April 2019
Resolution: Port nav light operational.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 11 April 2019 Resolved
Lock sewage overboard or toilet door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2019
Resolved 12 April 2019
Resolution: Toilet locked.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 April 2018 Resolved
Provide updated items in first aid kit; aspirin, iodine, amonnia inhalents
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2018
Resolved 12 April 2018
Resolution: Replaced expired medical supplies.
Documentation › Certificates/Documents › FCC SSL
Issued 6 April 2018 Resolved
Install radio emergency broadcast placard on pilothouse
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2018
Resolved 12 April 2018
Resolution: Installed radio broadcast placard in pilot house.
Documentation › Certificates/Documents › FCC SSL
Issued 6 April 2018 Resolved
Provide radio operator permit. (FCC)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2018
Resolved 12 April 2018
Resolution: Obtained radio operator's permit.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 April 2018 Resolved
Remove electrical hazard on forward outlet in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2018
Resolved 12 April 2018
Resolution: Installed guard over electrical hazard.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 April 2018 Resolved
Remove accumulation of oil on the main engine and air filter
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2018
Resolved 12 April 2018
Resolution: Removed accumulation of oil on the main engine and cleaned air filter.
Electrical › Electric Supply System (service) › Battery Charger
Issued 6 April 2018 Resolved
Provide ammeter onbattery charger
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2018
Resolved 12 April 2018
Resolution: Installed ammeter in pilot house.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 April 2018 Resolved
Provide proper operation for life ring buoy waterlight
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2018
Resolved 12 April 2018
Resolution: Replaced battery, tested sat.
Engineering › Bilge Water Management System › Hose
Issued 6 April 2018 Resolved
Make repairs on FWD pump discharge line
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2018
Resolved 12 April 2018
Resolution: REmoved degraded hose section and reinstalled.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 April 2018 Resolved
Prove pre-employment for current crewmembers
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2018
Resolved 12 April 2018
Resolution: Provided proof of pre-employment testing.
Engineering › Sea-water System (primary cooling) › Pump
Issued 23 August 2017 Resolved
Renew broken serpentine belt driving rew water cooling pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2017
Resolved 24 August 2017
Engineering › Fuel Oil Service System › Piping
Issued 5 May 2016 Resolved
Properly bond fuel fill piping on both fuel tanks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 29 June 2016
Resolution: The fuel fills were properly bonded.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 5 May 2016 Resolved
Provide FCC safety certificate.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 29 June 2016
Resolution: FCC safety certificate is now onboard.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 May 2016 Resolved
Provide radio operators permit for all licensed masters
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 29 June 2016
Resolution: Provided radio operators permit for all licensed masters
Engineering › Fuel Oil Service System › Piping
Issued 5 May 2016 Resolved
Properly label port and starboard fuel fills
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 29 June 2016
Resolution: The fuel fills are properly labeled.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 April 2014 Resolved
Provide waterlight for life ring buoy
Action required: 705 - Other - as specified
Due 18 May 2014
Resolved 28 April 2014
Resolution: The vesel installed new waterlight and tested.
Communications › Radio Communications › EPIRB
Issued 18 April 2014 Resolved
Provide EPIRB registration
Action required: 705 - Other - as specified
Due 18 April 2014
Resolved 28 April 2014
Resolution: A valid EPIRB registration was onboard the vessel
Documentation › Certificates/Documents › Stability Letter
Issued 18 April 2014 Resolved
Post stability letter under glass in the pilothouse
Action required: 705 - Other - as specified
Due 18 May 2014
Resolved 23 May 2014
Resolution: Stability letter is now posted
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 April 2014 Resolved
Install 60 feet of line on life ring buoy
Action required: 705 - Other - as specified
Due 18 May 2014
Resolved 28 April 2014
Resolution: Instralled 60 feet of buoyant line to buoy
Navigation › Piloting/Steering › Magnetic Compass
Issued 18 April 2014 Resolved
Install compass light and prove proper operation
Action required: 705 - Other - as specified
Due 18 May 2014
Resolved 26 June 2014
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 April 2014 Resolved
Properly affix official number to the interior structure of the vessel
Action required: 705 - Other - as specified
Due 18 May 2014
Resolved 26 June 2014
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 April 2014 Resolved
Seperate adult and child size life jackets
Action required: 705 - Other - as specified
Due 18 May 2014
Resolved 28 April 2014
Resolution: All life jackets are now properly seperated
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 18 April 2014 Resolved
Properly seal vapor barrier on bulkhead IWO portside lower bunk room
Action required: 705 - Other - as specified
Due 18 May 2014
Resolved 28 April 2014
Resolution: Vabor barrier provided and verified.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 April 2014 Resolved
Provide CG approved first aid kit
Action required: 705 - Other - as specified
Due 18 May 2014
Resolved 24 May 2014
Fire Fighting › Ventilation Systems › Operating Controls
Issued 18 April 2014 Resolved
Prove proper operation of engine room ventilation closures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2014
Resolution: Witness operation of ventilation closures.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 April 2014 Resolved
Install bonding system at rudder post, portside bilge valve, and supply toilet
Action required: 705 - Other - as specified
Due 18 April 2014
Resolved 28 April 2014
Engineering › Fuel Oil Service System › Filter
Issued 18 April 2014 Resolved
Install marine grade fuel filter on main engine
Action required: 705 - Other - as specified
Due 18 May 2014
Resolved 26 June 2014
Resolution: Marine grade filter installed and verified.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 April 2014 Resolved
Conduct underway drills
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2014
Resolution: Vessel''''s crew conducted satisfactory underway drills.
Engineering › Steering Gear System › Linkage
Issued 18 April 2014 Resolved
Conduct test of auxiliary steering system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2014
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 April 2014 Resolved
Conduct operationsl test of the fire boy system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2014
Resolution: Witnessed a satisfactory test of the fixed firefighting system
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 18 April 2014 Resolved
Post emergency procedures
Action required: 705 - Other - as specified
Due 18 May 2014
Resolved 26 June 2014
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 18 April 2014 Resolved
Provide CG approved lights for all life jackets onboard (vessel is restricted to limited coastwise rout)
Action required: 705 - Other - as specified
Resolved 26 June 2014
Resolution: CG approved lights were installed.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 24 March 2014 Resolved
Install proper ground tackle
Action required: 705 - Other - as specified
Due 18 May 2014
Resolved 28 April 2014
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 May 2012 Resolved
Test swabs for alcohol were expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 24 May 2012
Resolution: new ones provided.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 May 2012 Resolved
Child life jackets were stowed with the adult life jackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 24 May 2012
Fire Fighting › Fire Bucket › Stenciling
Issued 7 May 2012 Resolved
vessel did not have designated fire buckets. there were buckets and line onboard, but they were not designated or stenciled for firefighting requirements.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 24 May 2012
Communications › Radio Communications › EPIRB
Issued 7 May 2012 Resolved
O/O took down the EPIRB for the inspection. Registration, hydro, and battery were good, but it needs to be mounted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 24 May 2012
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 August 2011 Resolved
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2011
Resolved 23 September 2011
Resolution: Provided light list.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 August 2011 Resolved
Audible alarm on fwd bilge alarm not working. light comes on but no sound is produced.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2011
Resolved 23 September 2011
Resolution: Proved proper operation of fwd bilge alarm.
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 July 2009 Resolved
Both F/O suction valves remote actuators only closed valves half way. Correct deficiency to allow valves to be fully secured.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 27 July 2009 Resolved
Vsl does not have a medium frequency band radio; Vsl restricted to 20 NM from shore until SSB radio is provided.
Action required: 705 - Other - as specified
Resolved 6 October 2010
Resolution: Vsls route reduced; SSB no longer required & removed from vsl.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 July 2009 Resolved
All around (anchor) light is missing shield.
Due 17 August 2009
Resolved 27 July 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 July 2009 Resolved
Provide appropriate eye wash solution in first aid kit, currently using contact cleaning saline solution as eye wash.
Due 17 August 2009
Resolved 27 July 2009
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 July 2009 Resolved
Ensure life ring has proper amount of amount of retro reflective tape, and in good condition.
Due 27 July 2009
Resolved 27 July 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 July 2009 Resolved
Life ring light has un approved battery which is causing it to float to low in the water.
Due 27 July 2009
Resolved 27 July 2009
Operations/Management › Equipment Service/Testing › EPIRB
Issued 27 July 2009 Resolved
EPIRB test are not being logged monthly.
Due 27 July 2009
Resolved 27 July 2009
Resolution: Tested with CGMI, trained operator as to CFR requirement.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 27 July 2009 Resolved
Quarterly emergency drills are not being logged.
Due 27 July 2009
Resolved 27 July 2009
Resolution: Conducted U/W drills and trained operator as to CFR requirements.
Engineering › Fuel Oil Service System › Valve
Issued 7 August 2008 Resolved
Prove proper operation of STBD fuel shut-off.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2008
Resolved 18 August 2008
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 August 2008 Resolved
Secure aft portside railing with new fasteners.
Due 29 August 2008
Resolved 18 August 2008
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 7 August 2008 Resolved
Provide updated current actove employee list.
Due 29 August 2008
Resolved 26 August 2008
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 August 2008 Resolved
Replace alcohol test swabs, current swabs expired.
Due 29 August 2008
Resolved 26 August 2008
Resolution: Corrected
Lifesaving › Inflatable Liferafts › Not on Board
Issued 23 April 2008 Resolved
Provide (install) survival craft (IBA) of adequate capacity for persons carried. Raft servicing must be current.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2008
Resolution: Raft returned to vessel & installed.
Engineering › Steering Gear System › Rudder
Issued 23 June 2007 Resolved
Propose plan for, and affect permanent repair to, broken primary steering system (cable).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2007
Resolved 3 July 2007
Resolution: New hydraulic steering system installed.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 8 May 2007 Resolved
Inspect and repair shaft movement in way of cutlass bearing.
Condition: Improper/Lack of Maintenance
Due 14 May 2007
Resolved 1 June 2007
Construction/Loadline › Hull › Side Shell
Issued 8 May 2007 Resolved
Reglass stem, shaft base, and minor areas where wood surface are showing.
Condition: Improper Installation
Due 14 May 2007
Resolved 1 June 2007
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 8 May 2007 Resolved
Provide access to the MSD discharge valve.
Condition: Design Flaw
Due 14 May 2007
Resolved 1 June 2007
Construction/Loadline › Penetrations › Pipe Flange
Issued 8 May 2007 Resolved
Recaulk gaps in ER bulkhead with marine silicon.
Condition: Design Flaw
Due 14 May 2007
Resolved 1 June 2007
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 8 May 2007 Resolved
Provide proper brackets support for hudraulic lines to the anchor windlass system.
Condition: Improper Installation
Due 14 May 2007
Resolved 1 June 2007
Documentation › Certificates/Documents › FCC SSL
Issued 3 May 2007 Resolved
Provide an FCC operator license for the license master.
Due 8 May 2007
Resolved 1 October 2007
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 3 May 2007 Resolved
Provide a Medium frequency radio or be restricted to operating area of no more than 20 NM from shore.
Condition: Improper/Lack of Maintenance
Due 8 May 2007
Resolved 8 May 2007
Communications › Radio Communications › EPIRB
Issued 3 May 2007 Resolved
Relocate EPIRB to a float free position.
Due 8 May 2007
Resolved 8 May 2007
Engineering › Fuel Oil Service System › Valve, Control
Issued 3 May 2007 Resolved
Tighten support for port fuel emergency shut off
Condition: Improper Installation
Due 8 May 2007
Resolved 1 June 2007
Engineering › Fuel Oil Service System › Vent Pipe
Issued 3 May 2007 Resolved
Provide mesh for stbd fuel vent.
Condition: Improper/Lack of Maintenance
Due 8 May 2007
Resolved 8 May 2007
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 3 May 2007 Resolved
Provide a sturdy embarkation ladder.
Due 8 May 2007
Resolved 23 April 2008
Electrical › Electric Supply System (service) › Cable
Issued 27 April 2006 Resolved
Replace spliced shoretie with new shoretie cable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 8 May 2006
Resolution: Verified new shoretie on-board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 April 2006 Resolved
Properly clamp loose/excessive wiring in engine space and starboard forward area of berthing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 8 May 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 April 2006 Resolved
Install outlet cover on bridge where missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 8 May 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 27 April 2006 Resolved
Provide currently corrected chart, CG Light List, and US Coast Pilot or excerpts of same for areas vessel transits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 8 May 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 April 2006 Resolved
Replace expired items in first aid kit (asprin, eyewash, & inhalants).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 8 May 2006
Operations/Management › Equipment Service/Testing › EPIRB
Issued 27 April 2006 Resolved
Prove proper logging of monthly (30-day) EPIRB check.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 8 May 2006
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 27 April 2006 Resolved
Replace worn hose on MSD (head/toilet).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 8 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 27 April 2006 Resolved
Provide vessel name on 4 adult PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 8 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 April 2006 Resolved
Repair/replace retro-reflective tape on 07 PFDs in accordance w/ 46 CFR 185.604(h). Vessel personnel limited to 18 until completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 27 April 2006
Resolution: Operator provided 07 compliant PFDs w/ proper retro-tape prior to completion of inspection.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 April 2006 Resolved
Properly seal watertight bulkhead in starboard forward engine space bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 8 May 2006
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 14 July 2004 Resolved
Prove proper operation of main engine shut-down upon energizing fixed F/F bottle in engine room.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2004
Resolved 14 July 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 July 2004 Resolved
Install guard covering on rotating belts & pulleys on main engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2004
Resolved 14 July 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 July 2004 Resolved
Install lagging on main engine exhaust. Exhaust pipe lagging not installed during engine change-out inspection.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2004
Resolved 14 July 2004
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 July 2004 Resolved
Install covers over batteries in engine room.
Action required: 705 - Other - as specified
Due 31 July 2004
Resolved 14 July 2004
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 July 2004 Resolved
Install cap on pipe for unused through hull penetration on starboard side of main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2004
Resolved 14 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 July 2004 Resolved
Install proper terminal connectors for electrical wiring for fireboy terminal box in pilot house.
Action required: 705 - Other - as specified
Due 31 July 2004
Resolved 14 July 2004
Engineering › Bilge Water Management System › Not Operational
Issued 14 July 2004 Resolved
Prove proper operation of bilge high water alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2004
Resolved 14 July 2004
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 26 April 2004 Resolved
Provide a copy of the annual testing report submitted to headquarters for 2003.
Due 7 June 2004
Resolved 13 July 2004
Engineering › Bilge Water Management System › Piping
Issued 26 April 2004 Resolved
Clean all oil from engine and engine room bilge.
Due 7 June 2004
Resolved 13 July 2004
Documentation › Logs/Records
Issued 22 April 2002 Resolved
Properly log drills LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Due 22 May 2002
Resolved 6 June 2002
Electrical › Lighting (service)
Issued 22 April 2002 Resolved
Wire stern lt to nav lt panel. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 22 May 2002
Resolved 6 June 2002
Lifesaving › Hand Flares
Issued 22 April 2002 Resolved
Replace flares and smoke signals LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 22 May 2002
Resolved 6 June 2002
Lifesaving › Buoyant Apparatus
Issued 22 April 2002 Resolved
Provide proper lanyard for ring buoy water light
Condition: Improper Installation
Due 22 May 2002
Resolved 6 June 2002
Stability › Watertight Integrity
Issued 22 April 2002 Resolved
Attach valve handle to bait tank over board valve.
Condition: Improper/Lack of Maintenance
Due 22 May 2002
Resolved 6 June 2002
Operations/Management › Pollution
Issued 22 April 2002 Resolved
Clean ER bilges LEGACY COMPONENT DESC: Removal Methods/Procedures
Condition: Improper/Lack of Maintenance
Due 22 May 2002
Resolved 6 June 2002
Engineering › Sea-water System (primary cooling)
Issued 22 April 2002 Resolved
Double hose clamp all ER RW hoses. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 22 May 2002
Resolved 6 June 2002
Engineering › Lubricating Oil Service System
Issued 22 April 2002 Resolved
Repair oil leaks on MDE LEGACY COMPONENT DESC: Manifold
Condition: Improper/Lack of Maintenance
Due 22 July 2002
Resolved 6 June 2002
Engineering › Steering Gear System
Issued 22 April 2002 Resolved
Replace hydraulic steering hose on pump in ER. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Improper/Lack of Maintenance
Due 23 May 2002
Resolved 6 June 2002
Engineering › Fuel Oil Service System
Issued 22 April 2002 Resolved
Provide bowl on fuel filter. LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Due 22 May 2002
Resolved 6 June 2002
Electrical › Lighting (service)
Issued 22 April 2002 Resolved
replace lighting fixtures in ER. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Placed in Improper Service
Due 23 May 2002
Resolved 6 June 2002
Electrical › Electrical Distribution System (service)
Issued 22 April 2002 Resolved
Hang all ER cables with metal hangers. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 22 May 2002
Resolved 6 June 2002
Electrical › Electrical Distribution System (service)
Issued 22 April 2002 Resolved
Remove dead ended cables in ER. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 22 May 2002
Resolved 6 June 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 April 2002 Resolved
Provide operating lights for PFDs prior to resuming an Oceans route LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 6 June 2002
Accommodation/Occupational Safety
Issued 24 April 2001 Resolved
Properly mark escape hatch.
Condition: Unknown
Due 9 May 2001
Resolved 22 June 2001
Fire Fighting
Issued 24 April 2001 Resolved
Repair halon system and engine automatic shutdown
Condition: Unknown
Due 9 May 2001
Resolved 22 June 2001
Lifesaving
Issued 24 April 2001 Resolved
Provide corrosion resistant clip for life ring lanyard.
Condition: Unknown
Due 9 May 2001
Resolved 22 June 2001
Fire Fighting
Issued 24 April 2001 Resolved
Repair halon manual discharge cable
Condition: Unknown
Due 9 May 2001
Resolved 22 June 2001
Construction/Loadline
Issued 12 March 2001 Resolved
Repair damaged propeller.
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Construction/Loadline
Issued 12 March 2001 Resolved
Properly repair 3"X 14" hole in hull approximately 3' from trandom, 6" to the starboard of and extending perpendicular to the keel.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Construction/Loadline
Issued 12 March 2001 Resolved
Renew broken propeller shaft strut
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Construction/Loadline
Issued 2 February 2001 Resolved
Provide metallic valve penetrations for PVC piping traversing watertight bulkheads.
Condition: Unknown
Due 1 February 2002
Resolved 25 January 2002
Resolution: Attended vessel at helgrins pier. Inspected for non-metallic penetrations. Found none. Cleared erronious CG-835
Construction/Loadline
Issued 2 February 2001 Resolved
Provide damage control kit to be maintained until installation of a proper bulkhead.
Condition: Unknown
Due 16 July 2001
Resolved 16 July 2001
Documentation
Issued 28 April 2000 Resolved
Provide valid safety radio certificate.
Condition: Unknown
Due 15 May 2000
Resolved 27 December 2000
Lifesaving
Issued 28 April 2000 Resolved
Provide proper emergency instructions placard.
Condition: Unknown
Due 15 May 2000
Resolved 27 December 2000
Lifesaving
Issued 28 April 2000 Resolved
Provide means to seperate child and adult lifejackets while stowed.
Condition: Unknown
Due 15 May 2000
Resolved 27 December 2000
Fire Fighting
Issued 28 April 2000 Resolved
Provide proper operation of fixed fire fighting system prior to carrying passengers.
Condition: Unknown
Due 10 May 2000
Resolved 27 December 2000
Electrical
Issued 28 April 2000 Resolved
Provide operable navigation lights. Vessel restricted to daylight operations only and clear visibility until lights repaired.
Condition: Unknown
Due 15 May 2000
Resolved 27 December 2000
Lifesaving
Issued 28 April 2000 Resolved
Provide first aid kit IAW CG check-off list.
Condition: Unknown
Due 15 May 2000
Resolved 27 December 2000
Lifesaving
Issued 28 April 2000 Resolved
Provide extra life jacket placard on vessel's main deck.
Condition: Unknown
Due 15 May 2000
Resolved 27 December 2000
Fire Fighting
Issued 23 April 1999 Resolved
Provide proper ventilation stops IAW 46CFR181.410(b)(10).
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Documentation
Issued 23 April 1999 Resolved
Provide alcohol test kit IAW 46CFR4.06-20.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Fire Fighting
Issued 23 April 1999 Resolved
Provide smoke detector alarm for the passenger accommodation space IAW 46CFR400(e).
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Navigation
Issued 24 November 1998 Resolved
CORRECT NAVIGATIONAL CHARTS AND PUBLICATIONS FOR ROUTES USED AND PROVIDE PROOF OF BEING PLACED ON THE MAILING LIST FOR THE LOCAL NOTICE TO MARINERS.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Navigation
Issued 14 April 1998 Resolved
Replace missing/damaged stern light.
Condition: Unknown
Due 15 April 1998
Resolved 8 May 1998
Lifesaving
Issued 14 April 1998 Resolved
Replace/repair 1 adult lifejacket.
Condition: Unknown
Due 15 April 1998
Resolved 8 May 1998
Lifesaving
Issued 14 April 1998 Resolved
Rig painter properly to BA.
Condition: Unknown
Due 15 April 1998
Resolved 8 May 1998
Lifesaving
Issued 14 April 1998 Resolved
Replaced expired EPIRB battery. Vessel not to embark passengers until replaced.
Condition: Unknown
Due 15 April 1998
Resolved 8 May 1998
Construction/Loadline
Issued 14 April 1998 Resolved
Reroute Hydraulic lines as not to penatrate collision bulkhead.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Construction/Loadline
Issued 14 April 1998 Resolved
Replace missing hatch dogs on all 3 hatches.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Engineering
Issued 15 April 1997 Resolved
Repair main propulsion diesel engine heat exchanger oil leak. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Navigation
Issued 15 April 1997 Resolved
Provide three (3) black ball day shapes (.6 meter/18-24 inches diameter). _x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Engineering
Issued 15 April 1997 Resolved
Install flame screens to port fuel oil tank vent. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Navigation
Issued 15 April 1997 Resolved
Provide a watertight container painted in bright color and marked "DistressSignals" for flares. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Engineering
Issued 7 November 1996 Resolved
Renew fuel line from tank to engine, supply and return line._x001C_
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Engineering
Issued 7 November 1996 Resolved
Renew fuel shut off valve on stb tank._x001C_
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Engineering
Issued 7 November 1996 Resolved
Repair fuel leak on stb fuel tank at fill line._x001C_
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Construction/Loadline
Issued 7 November 1996 Resolved
Repair fwd bilge alarm._x001C_
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Lifesaving
Issued 19 April 1995 Resolved
Conduct under way man overboard and fire drills._x001C_
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Lifesaving
Issued 19 April 1995 Resolved
Install retroreflective tape on buoyant apparatus. _x001C_
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Engineering
Issued 19 April 1995 Resolved
Repair main engine gauges at control station.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Engineering
Issued 19 April 1995 Resolved
Label emergency fuel oil shut off valves._x001C_
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Fire Fighting
Issued 19 April 1995 Resolved
Provide proper the length of hose for hand fire pump._x001C_
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Electrical
Issued 1 April 1994 Resolved
BONDING WIRE NO LONGER IN USE TO BE REMOVED OR RESTOWED OR PLACED BACK IN SERVICE.
Condition: Unknown
Due 1 April 1994
Resolved 1 April 1994
Construction/Loadline
Issued 1 April 1994 Resolved
RUBRAIL IN THE VACINITY OF PORTSIDE, TRANSOM HAS BEEN DAMAGED AND WORN. MATER TO RENEW TO GOOD WOOD.
Condition: Unknown
Due 1 April 1994
Resolved 1 April 1994
Navigation
Issued 4 May 1993 Resolved
REPAIR INOPERABLE MASTHEAD LIGHT.
Condition: Unknown
Due 11 May 1993
Resolved 7 May 1993
Lifesaving
Issued 22 April 1992 Resolved
PROVIDE PROPER PERMANENT MARKING FOR PASSENGER ACCOMODATION SPACE EMERGENCYESCAPE.
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Lifesaving
Issued 22 April 1992 Resolved
PROVIDE THREE (3) BLACK BALL DAY SHAPES AND A RED/RED 'NOT UNDER COMMAND LIGHT.'
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Construction/Loadline
Issued 22 April 1992 Resolved
REPAIR INOPERABLE BILGE ALARM IN ENGINE ROOM.
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Accommodation/Occupational Safety
Issued 22 April 1992 Resolved
REPLACE BROKEN HINGE ON EMABARKATION RAIL.
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Engineering
Issued 4 December 1991 Resolved
PROPERLY ALIGN THE SHAFT TO THE MAIN ENGINE AND CONDUCT UNDERWAY TEST TO CHECK FOR PROPER OPERATION PRIOR TO OPERATION WITH PASSENGERS.
Condition: Unknown
Due 13 December 1991
Resolved 13 December 1991
Documentation
Issued 13 June 1991 Resolved
PROVIDE DOCUMENTATION TO SUPPORT COMPLIANCE WITH THE PROGRAM FOR CHEMICAL DRUG AND ALCOHOL TESTING OF VESSEL PERSONNEL IN ACCORDANCE WITH 46 CFR 16.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Lifesaving
Issued 13 June 1991 Resolved
REPLACE ALL OUTDATED BATTERIES ON ALL LIFE PRESERVERS ON BOARD WITH NEW DATED BATTERIES. THE VESSEL IS LIMITED TO LIMITED COASTWISE ROUTE UNTIL SATISFACTORY CORRECTED.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Documentation
Issued 13 June 1991 Resolved
PROVIDE THE VESSEL WITH A MASTER WITH A VALID LICENSE PRIOR TO AND WHEN OPERATING THE VESSEL WITH PASSENGERS.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Lifesaving
Issued 13 June 1991 Resolved
REPLACE OUTDATED BATTERY ON THE EPIRB. THE VESSEL IS LIMITED TO LIMITED COASTWISE ROUTE UNTIL SATISFACTORY CORRECTED.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Lifesaving
Issued 6 June 1990 Resolved
PROVIDE FOUR (4) ADDITIONAL ADULT SIZE LIFE PRESERVERS, TYPE I, TO BRING THE TOTAL OF TWENTY-SEVEN (27) ADULT SIZE LIFE PRESERVERS ON BOARD. VESSEL IS LIMITED TO THE TOTAL OF TWENTY-THREE (23)PERSONS (PASSENGERS & CREW) ALLOWED ON BOARD UNTIL CORRECTED.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Accommodation/Occupational Safety
Issued 24 May 1990 Resolved
PROVIDE MEANS OF LOCKING THE OVERBOARD DISCHARGE VALVE ON THE MARINE SANITATION DEVICE HOLDING TANK.
Condition: Unknown
Due 24 May 1990
Resolved 24 May 1990
Lifesaving
Issued 24 May 1990 Resolved
PROVIDE ONE (1) WATER LIGHT IN GOOD CONDITION ON THE REQUIRED LIFE FLOAT ON BOARD.
Condition: Unknown
Due 24 May 1990
Resolved 24 May 1990
Navigation
Issued 25 January 1990 Resolved
PROVIDE AN OPERATIONAL SINGLE SIDE BAND RADIO ON BOARD. UNTIL CORRECTED THEVESSEL IS LIMITED TO OCEAN ROUTE BETWEEN PT. CONCEPTION, CA AND LATITUDE 30DEGREES 45 MINUTES NORTH NOT MORE THAN 60 MILES OFF A BASELINE EXTENDING FROM PT. CONCEPTION TO CAPE SAN LUCAS, BAJA CALIFORNIA, MEXICO.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Engineering
Issued 25 January 1990 Resolved
PROVIDE APPROVED TYPE NON-METALLIC FLEX HOSES TO THE FUEL OIL LINE FROM THEFILTER/STRAINER TO THE MAIN PROPULSION.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Engineering
Issued 25 January 1990 Resolved
PROVIDE UL APPROVED FOR MARINE USE FUEL OIL FILTER/STRAINER TO THE MAIN PROPULSION.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Construction/Loadline
Issued 30 May 1989 Resolved
PROVIDE DOUBLE CLAMPS TO PORT AND STBD. BAIT PUMP SUCTION LINES AT F/O TANKSPACE.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Lifesaving
Issued 30 May 1989 Resolved
PROVIDE 5 ADULT LIFE PRESERVERS EACH EQUIPPED WITH LIGHT. VESSEL IS LIMITEDT0 18 PERSONS (PASSENGERS AND CREW) TOTAL ALLOWED ON BOARD.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Navigation
Issued 8 June 1988 Resolved
PROVIDE CURRENT LIGHT LIST AND TIDE TABLES.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Lifesaving
Issued 8 June 1988 Resolved
PROVIDE ONE PADDLE FOR LIFEFLOAT.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Lifesaving
Issued 8 June 1988 Resolved
SEPERATE LIFE FLOATS WITH SLATS.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Navigation
Issued 8 June 1988 Resolved
PROVIDE AN 8" BELL.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Engineering
Issued 29 May 1986 Resolved
PROVIDE AN EXHAUST DUCT OF AT LEAST 16 SQUARE INCHES CROSS-SECTION FOR THE ENGINE ROOM, RUN TO THE LEVEL JUST ABOVE ENGINEROOM BILGE WATER AND VENTING TO THE ATMOSPHERE.
Condition: Unknown
Due 29 May 1986
Resolved 29 May 1986
Navigation
Issued 29 May 1986 Resolved
PROVIDE COAST PILOT.
Condition: Unknown
Due 29 May 1986
Resolved 29 May 1986

Casualty record · 4

23 June 2007Routine · role: Involved in a Marine Casualty · activity 3013598
29 August 2016Routine · role: Involved in a Marine Casualty · activity 5986915
23 August 2017Routine · role: Involved in a Marine Casualty · activity 6251608
4 August 2023Routine · role: Involved in a Marine Casualty · activity 7764122
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

ADVANCE (2007), VENDETTA (2016–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.