Records from 1987 to 2025. Most recent: inspection, 12 May 2025.
Inspection history · 51
12 May 2025
Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8134899
14 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7880848
16 February 2023
Hull Examination · Deficiency Check · COI Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7636422
18 November 2022
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7596836
8 November 2021
Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7347565
28 August 2020
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7047858
20 August 2019
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6789788
3 May 2018
Internal Structural Exam · MTSA Verification · Administrative Inspection · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6404790
30 September 2016
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6015675
7 October 2015
COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5737085
15 July 2015
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5185569
28 May 2015
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5143437
22 May 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5137045
24 September 2014
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4991688
27 February 2014
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4807011
10 October 2013
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4732654
17 September 2012
Cargo Tank Internal · Internal Structural Exam · Annual Inspection · Drydock Exam · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4444110
28 September 2011
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4156450
12 October 2010
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3868477
3 December 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3373679
15 October 2008
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3345889
17 October 2007
Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3081831
20 September 2007
Internal Structural Exam · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3075411
17 October 2006
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2802916
26 October 2005
COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2522296
13 May 2005
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2356591
11 January 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2272742
11 January 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2272773
17 November 2004
MTSA Verification · Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2242716
3 November 2003
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1941270
21 November 2002
Annual Inspection · Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1711127
5 November 2001
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1076107
7 November 2000
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1361800
16 November 1999
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 810617
10 November 1998
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1420018
18 November 1997
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1413264
4 November 1997
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 786539
3 November 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756639
11 October 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 102497
11 October 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 206192
6 November 1996
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1360660
12 February 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 753646
9 February 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 206190
7 November 1995
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 871154
10 April 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 753665
7 April 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 206183
10 November 1994
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 869392
7 February 1994
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 860176
8 December 1992
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1136554
2 December 1992
COI Inspection · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 825906
11 June 1987
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1029532
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2023
Resolved
Electric installations on vessels must ensure:
(1) Maintenance of services necessary for safety under normal and emergency conditions. Lighting, shore power connector and supply fan electrical installation not IAW regulations. Make repairs to satisfaction of MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 27 February 2023
Resolution: Received objective evidence of electrical installation in compliance with requirements.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 November 2022
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual and periodic inspections within the the periods specified in 46 CFR 31.10-17(a) and (b). The vessels annual inspection is 6 months overdue and the current COI has been invalidated. Complete new COI inspection. Vessel is restricted from cargo operations and movement.
46 CFR 31.10-17a
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 February 2023
Resolution: Completed DDE/ISE/CTISE and COI inspections.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 8 November 2021
Resolved
Hoses 104, 108, 112 we found to be creased and in deteriorating conditions.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 15 November 2021
Resolved 8 November 2021
Resolution: Hose's that were being replaced were removed from vessel. Vessel stated they were extra and not needed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021
Resolved
Emergency pull did not actuate fuel cut off valve. Repair valve pull to allow for complete shutoff.
Action required: 703 - Prior to bunkering operations
Due 15 November 2021
Resolved 8 November 2021
Resolution: Fuel shut off was adjusted and retested. Now working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2020
Resolved
Remove all dead-end wiring. Install covers on all exposed junction boxes. Install light bulbs in open receptacles.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2020
Resolved 15 November 2021
Resolution: Done from an earlier date.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 28 August 2020
Resolved
Cargo trasnfer hoses were not properly marked with the MAWP. Mark/stencil hoes with hoses MAWP that will not wear off between testings.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2020
Resolved 15 November 2021
Resolution: Done from an earlier date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 August 2020
Resolved
Place heat resistant lagging on all exhaust piping that exceeds a temperature of 150 degrees. Found exhaust from pump engine not to be covered in protective wrap to prevent barge personnel injury.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2020
Resolved 15 November 2021
Resolution: Done from an earlier date.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 28 August 2020
Resolved
Found numerous cargo transfer hoses to be crimped, crushed and showing inner wire wrap. These hoses are to be removed from the barge and not used for a regulated oil transfer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2020
Resolved 15 November 2021
Resolution: Done from an earlier date.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 August 2020
Resolved
Remove all excessive oil and oil residue from cargo engine room surfaces. Found cargo pump engine room to have excessive oil residue and oil the bilge and surfaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2020
Resolved 15 November 2021
Resolution: Done from an earlier date.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 7 October 2015
Resolved
Hudraulic oil leaks on aft end of engine
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 9 October 2015
Electrical › Lighting (service) › Outlet Box
Issued 7 October 2015
Resolved
Fixture in hazardous location missing plug
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 9 October 2015
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 7 October 2015
Resolved
Fuel oil pipe not properly securred. Provide proper gasket and blind flange.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 9 October 2015
Construction/Loadline › Hull › Hull Plating
Issued 17 September 2012
Resolved
Large area of pitting through out fwd and stern rakes and port/stbd bilge knuckles. These areas have been marked and crop/renew to follow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2012
Resolved 29 November 2012
Resolution: Gauged entire hull, cropped and renewed all areas as per readings.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 October 2008
Resolved
-The VRP must be amended to state that training regimens apply to the qualified and alternate qualified individuals, and members of the spill management team per Reg 33 CFR 155.1055
-The geographic-specific appendices in the VRP must be amended to align with the 33 CFR Part 3 technical amendments to reflect the introduction of Sector Commands.
Due 21 November 2008
Resolved 16 December 2008
Resolution: Deficiencies fixed with revision submitted 12/4/08. Vessel approved for resubmission. Vessel expiration date 12/23/2013 (VRP #00154)
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 October 2008
Resolved
-Per Reg 33 CFR 155.1040(k), the barge-specific appendices must be amended to include the individual capacities of all ballast tanks.
Due 21 November 2008
Resolved 16 December 2008
Resolution: Deficiencies fixed with revision submitted 12/4/08. Vessel approved for resubmission. Vessel expiration date 12/23/2013 (VRP #00154)
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 September 2007
Resolved
Remove from hazardous location or replace w/intrinsically safe/explosion proof equipment the following: A) junction box at stern centerline B) Electric panel in way of #3 CT hatch for midship electric pump C) lighting fixture and junction box at forward end.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 17 October 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 17 November 2004
Resolved
Cargo transfer hose not tested within past 12 months.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2004
Resolved 26 October 2005
Electrical › Lighting (service) › Outlet Box
Issued 17 November 2004
Resolved
non-explosion proof lighting and power outlets installed in wooden doghouse on deck of barge. Replace with explosion-proof fixtures.
Condition: Placed in Improper Service
Due 30 November 2004
Resolved 26 October 2005
Engineering
Issued 5 November 2001
Resolved
replace flame screen
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Construction/Loadline
Issued 5 November 2001
Resolved
replace dog an hatch lid
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001