Records from 2012 to 2026. Most recent: inspection, 17 June 2026.
Inspection history · 17
17 June 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8380538
31 October 2025
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8260068
21 May 2025
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8133026
12 November 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8020920
5 December 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7833653
26 October 2023
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7815357
1 November 2022
Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7587222
18 November 2021
Drydock Exam · Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7352445
4 November 2021
Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7345901
15 December 2020
COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7112260
8 December 2020
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7109299
5 November 2019
Annual Inspection · Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6849964
16 November 2018
Administrative Inspection · Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6661354
21 December 2017
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6559886
6 November 2017
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6519834
31 August 2016
COI Inspection · DAPI Audit · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5988819
12 January 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5852637
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 June 2026
Resolved
Life float light doesn't work. Replace or renew with correct battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 June 2026
Resolved
03 red flares have expired. Replace with new flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 November 2024
Resolved
Each EPIRB, other than an EPIRB in a inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Vessel has an inoperable EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2024
Resolution: Owner was able to find and register the new EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 November 2024
Resolved
EPIRB hydrostatic release is expired and needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 November 2024
Resolved
The words "FIRE BUCKET" must be stenciled in a
contrasting color on each bucket. Vessel needs to
mark each fire bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2024
Resolution: Fire buckets have been labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 November 2024
Resolved
Attach port and starboard watertight hatches to their
respective hatch frames with a captive chain or other
device.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2024
Resolution: Hatches have been reattached.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 December 2020
Resolved
Vessel did not have a paper copy of NAV chart and the new installed Garmin GPS verson installed was 17.2. Garmin's latest verson is 21.0 Update garmin to latest verson or get a paper correct NOAA chart.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2021
Resolved 30 December 2020
Resolution: Uploaded lastest softwhere version on GPS.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 December 2020
Resolved
Vessel annual date was 30 AUG 2020. Vessel failed to have annual inspection done before 30 NOV 2020. Vessel will have COI inspection completed to the satisfaction on the attending Coast Guard Marine Inspector prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2020
Resolved 16 December 2020
Resolution: COI inspection completed
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 December 2020
Resolved
Since your vessel did not complete the annual inspection, your COI is not valid. Vessel must be in full compliance with the terms of the certificate prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 December 2020
Resolved 16 December 2020
Resolution: COI inspection completed, issued new COI
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 November 2019
Resolved
7 Adult life jackets are not serviceable. Replace prior to carrying more than 17 total persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2019
Resolution: 7 new adult PFDs were placed into service.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 November 2019
Resolved
Life float must have new reflective materials, and vessel name on both sides.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 November 2019
Resolution: Name and reflective tape was applied to both sides of the life float.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 November 2019
Resolved
Update chart, and/or chart plotter data.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 November 2019
Resolution: New charts were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 November 2019
Resolved
Remove wasted section of sea painter on life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 November 2019
Resolution: New sea painter was installed on the life float.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 December 2017
Resolved
COI and stability letter are not onboard, or posted. Post both for view onboard the vessel.
Action required: 10 - Deficiency Rectified
Resolved 4 January 2018
Resolution: All required documents were posted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 December 2017
Resolved
Both Life floats have wasted reflective tape. Renew/replace. Owner stated that 2 new life floats are on order and will be placed into service upon receipt.
Action required: 10 - Deficiency Rectified
Resolved 4 January 2018
Resolution: 2 new life flots were purchased and placed into service.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 December 2017
Resolved
First aid kit is missing required contents. renew kit or contents.
Action required: 10 - Deficiency Rectified
Resolved 4 January 2018
Resolution: New approved first aid was provided.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 December 2017
Resolved
Vessel COD is expired. Provide new COD prior to operations.
Action required: 10 - Deficiency Rectified
Resolved 4 January 2018
Resolution: New COD was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 December 2017
Resolved
2 adfult PFD are no longer servicable. Provide new PFD prior to carrying more than 20 passengers.
Action required: 10 - Deficiency Rectified
Resolved 4 January 2018
Resolution: 2 new PFD were purchased and placed into service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 December 2017
Resolved
1 child size PFD is not longer serviceable, renew.
Action required: 10 - Deficiency Rectified
Resolved 4 January 2018
Resolution: New child PFD was provided.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 21 December 2017
Resolved
VHF does not have MMSI number programed, and does not link to the vessel GPS.
Action required: 10 - Deficiency Rectified
Resolved 4 January 2018
Resolution: VHF was reprogramed with MMSI number and linked to the vessel GPS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 December 2017
Resolved
B-II fire extinguisher is rusted and has large corrosion bubbles around the neck. Provide new extinguisher or have old one hydro tested.
Action required: 10 - Deficiency Rectified
Resolved 4 January 2018
Resolution: New fire extinguisher was replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 December 2017
Resolved
Aft bulkhead in the engineroom has large openings for wires. These opening must be sealed. Enclose wires with proper penetrations that make the bulkhead vapor tight.
Action required: 10 - Deficiency Rectified
Resolved 4 January 2018
Resolution: Wire runs were sealed with fire retardant putty.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 December 2017
Resolved
Fuel hose that runs from the RACOR fuel filter to the main engine fuel pump is chaffed into the armor. Renew the hose and apply chaffing gear to the area to protect the new hose from damage.
Action required: 10 - Deficiency Rectified
Resolved 4 January 2018
Resolution: New hose with chaffing gear was installed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 31 August 2016
Resolved
alcohol test strips are expired, provide new strips.
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 6 September 2016
Resolution: New alcohol strips were provided.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 31 August 2016
Resolved
Vessel does not have emergency instructions list available. Provide.
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 6 September 2016
Resolution: Emergency instructions were created and posted.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 31 August 2016
Resolved
Vessel does not have a valid Safety Radiotelephony certificate, Provide.
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 6 September 2016
Resolution: New FCC safety radio cert was provided.
Documentation › Markings/Placards › Garbage Placard
Issued 31 August 2016
Resolved
vessl does not have a marpol placard. Provide
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 6 September 2016
Resolution: MARPOL placard was posted.
Navigation › Piloting/Steering › Magnetic Compass
Issued 31 August 2016
Resolved
vessel compass light is extinguished. Repair or renew.
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 6 September 2016
Resolution: New compass light was installed and tested sat.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 31 August 2016
Resolved
Vessel does not have propper nautical publications. Provide light list and coast pilot.
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 6 September 2016
Resolution: All charts and pubs were updated.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 August 2016
Resolved
Grab lines and light lines are wasted and need to be replaced.
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 6 September 2016
Resolution: New life ring was supplied and line on light was replaced.