Records from 1980 to 2004. Most recent: inspection, 20 April 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
20 April 2004
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 2056496
3 July 2002
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 1640992
3 July 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1647892
16 September 1999
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 1510720
3 June 1997
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1110004
19 June 1995
COI Inspection · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1387816
23 March 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1355156
26 April 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1014294
10 August 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1157527
17 June 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1155375
10 March 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151105
18 June 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 959370
8 May 1992
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 950688
1 May 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 960124
20 May 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1241682
26 April 1990
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 918938
28 June 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1206486
28 April 1987
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1327369
20 June 1986
COI Inspection · Credit Drydock
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1304330
3 April 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 981239
3 April 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1291169
4 May 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973492
5 April 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 964850
8 March 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968481
10 February 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1278081
8 April 1980
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 972109
Documentation
Issued 3 June 1997
No resolution recorded
COMPETE A SATISFACTORY RE-INSPECTION IAW 46 CFR 176.500.
Condition: Unknown
Due 3 July 1997 — due date passed with no resolution recorded
Lifesaving
Issued 3 June 1997
No resolution recorded
RENEW LIFE RING BUOY IAW 46 CFR 180.070.
Condition: Unknown
Due 3 July 1997 — due date passed with no resolution recorded
Lifesaving
Issued 3 June 1997
No resolution recorded
RENEW BUOYANT APPARATUS WITH AN APPROVED LIFEFLOAT IAW 46 CFR 160.027.
Condition: Unknown
Due 3 July 1997 — due date passed with no resolution recorded
Construction/Loadline
Issued 3 June 1997
No resolution recorded
COMPLETE A SATISFACTORY CREDIT DRYDOCK INSPECTION AND SEA TRIAL IAW 46 CFR 176.600
Condition: Unknown
Due 3 July 1997 — due date passed with no resolution recorded
Documentation
Issued 23 March 1995
Resolved
CONDUCT SIMPLIFIED STABILITY TEST TO ACCOUNT FACTOR OF NEWLY INSTALLED ENCLOSED PILOT HOUSE.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Construction/Loadline
Issued 23 March 1995
Resolved
MAKE REPAIR OF CRACKED STRINGERS, PORT AND STARBOARD, BELOW DECK OF FORWARDACCOMODATION SPACE.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Accommodation/Occupational Safety
Issued 23 March 1995
Resolved
THROUGH BOLT UPPER DECK HAND RAIL STANCHIONS.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Accommodation/Occupational Safety
Issued 17 June 1993
Resolved
MAKE PROPER REPAIRS TO TWO BROKEN HAND RAIL STANTIONS STBD SIDE FORWARD.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Engineering
Issued 17 June 1993
Resolved
PROVIDE PROPULSION ENGINE SHUT DOWN AT UPPER CONTROL STATION.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Engineering
Issued 17 June 1993
Resolved
MAKE PROPER REPAIR TO LEAKING STBD ENGINE COOLING WATER PUMP AND PARTIALLY COLLAPSED SUCTION HOSE.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Engineering
Issued 17 June 1993
Resolved
PROVE OPERATIONOF PORT AND STBD MAIN ENGINE OIL PRESSURE GAUGE AT UPPER STATION.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Construction/Loadline
Issued 17 June 1993
Resolved
PROVE OPERATION OF ENGINE DRIVEN BILGE PUMP.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Construction/Loadline
Issued 17 June 1993
Resolved
PROVIDE REMOTE OPERATING SWITCH AND INDICATOR LIGHT FOR BOTH SUBMERSIBLE BILGE PUMPS.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Electrical
Issued 17 June 1993
Resolved
REPLACE WIRE NUTS IN SUBMERSIBLE ELECTRIC BILGE PUMP WIRING WITH PROPER FITTING.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Electrical
Issued 18 June 1992
Resolved
RENEW OR REMOVE ALL INTERIOR 110 VOLTS LIGHTING FIXTURES.
Condition: Unknown
Due 18 June 1992
Resolved 18 June 1992
Electrical
Issued 18 June 1992
Resolved
PROVIDE REQUIRED GUAGES FOR 110 VOLT GENERATOR.
Condition: Unknown
Due 18 June 1992
Resolved 18 June 1992
Lifesaving
Issued 18 June 1992
Resolved
PROVIDE SIGN ON CHAIN PROHIBITING PASSENGER ON FORE DECK.
Condition: Unknown
Due 18 June 1992
Resolved 18 June 1992
Construction/Loadline
Issued 18 June 1992
Resolved
PROVIDE TURN BUCKLES TO TIGHTEN LIFERAIL CABLES.
Condition: Unknown
Due 18 June 1992
Resolved 18 June 1992
Engineering
Issued 26 April 1990
Resolved
PROVIDE PROTECTIVE GUARDS FOR STBD ENGINE BELT-DRIVEN PUMP
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Electrical
Issued 26 April 1990
Resolved
PROVIDE LIGHT GUARDS AND GLASS FOR ENGINE ROOM LIGHTS
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Navigation
Issued 26 April 1990
Resolved
INSTALL BRACKET FOR FLYING BRIDGE MAGNETIC COMPASS TO PREVENT FROM MOVING WHILE UNDERWAY
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Navigation
Issued 26 April 1990
Resolved
PROVIDE MARINE CHARTS WITH LORAN C LINES FOR AREA OF OPERATION
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Electrical
Issued 26 April 1990
Resolved
PROVIDE COVER PLATES FOR 110V LIGHT OUTLETS
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Construction/Loadline
Issued 26 April 1990
Resolved
DRYDOCK VESSEL TO REPAIR CAULKING LEAKS IN WAY OF BOW STEM AND SIDE PLANKING IN STEERING GEAR COMPARTMENT.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Electrical
Issued 26 April 1990
Resolved
PROVIDE VOLTMETER, AMP METER, AND FREQUENCY METER FOR ONAN GENERATOR
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Fire Fighting
Issued 26 April 1990
Resolved
RENEW OR REPAIR HAND BILGE PUMP AND DEMONSTRATE OPERATION
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Electrical
Issued 26 April 1990
Resolved
EITHER PROVIDE DOCUMENTATION WHICH SHOWS ONAN GENERATOR IS RATED FOR 50 C AMBIENT TEMPERATURE OR DE-RATED AMPERAGE OUTPUT TO 80% OF FULL LOAD.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Navigation
Issued 26 April 1990
Resolved
DOUBLE NUT OR PLACE COTTER PINS ON STEERING GEAR SYSTEM LINKAGES.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Lifesaving
Issued 28 April 1987
Resolved
PROVIDE ON BOARD APPROPRIATE SIZE WEAK LINK FOR 13 PERSON LIFE FLOAT.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Navigation
Issued 28 April 1987
Resolved
PROVIDE 3 SPHERE DAY SHAPES (BLACK).
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Electrical
Issued 28 April 1987
Resolved
DEMONSTRATE OPERATION OF GENERATOR.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Electrical
Issued 28 April 1987
Resolved
PROVIDE AND DEMONSTRATE OPERATION OF REQUIRED GENERATOR GUAGES.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Engineering
Issued 28 April 1987
Resolved
MOUNT AND DEMONSTRATE PORT FUEL SHUT-OFF REACH-RODS.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987