Records from 1993 to 2019. Most recent: inspection, 22 August 2019.
Inspection history · 10
22 August 2019
NPV Safety Exam · Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6794762
3 April 2002
In-Service Inspection · Administrative Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1600570
23 October 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 729564
1 August 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 57479
29 December 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 386400
9 November 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 384840
10 October 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 714568
5 October 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 382864
5 May 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1038951
24 May 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 358569
Unknown
Issued 29 December 1995
Resolved
Provide letter from class accepting the vessel's SOPEP.
Condition: Unknown
Due 21 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 5 October 1995
Resolved
Provide rescue boat required by the Safety Constuction Certificate.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Documentation
Issued 5 October 1995
Resolved
Provide certificates meeting the requirements of STCW, Article II (C), VI (2) and RegulationI/2.
Condition: Unknown
Due 5 November 1995
Resolved 10 October 1995
Construction/Loadline
Issued 5 October 1995
Resolved
Repair numerous structural and watertight integrity problems to satisfaction of class society.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Navigation
Issued 5 October 1995
Resolved
Privide means of communication from the steering motor to the pilot house.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Engineering
Issued 5 October 1995
Resolved
Repair or replace missing/inadequate flame screens and fuel vent risers thoughout vessel.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Documentation
Issued 5 October 1995
Resolved
Demonstrate adequate manning. Vessel had no manning certificate and only one mate for a vessel of 499 gross tons.
Condition: Unknown
Due 5 October 1995
Resolved 10 October 1995
Fire Fighting
Issued 5 October 1995
Resolved
Replace two mising handles for cut-out valves on main firefighting line.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Documentation
Issued 5 October 1995
Resolved
The hull must be marked as required by the Loadline Certificate.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Navigation
Issued 5 October 1995
Resolved
Provide compass deviation table for new magnetic compass.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Documentation
Issued 5 October 1995
Resolved
Provide Shipboard Oil Pollution Emergency Plan (SOPEP).
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996