Records from 2007 to 2025. Most recent: inspection, 27 August 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 30
27 August 2025
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8230083
22 January 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8067376
7 November 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8031839
1 November 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7818724
26 October 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7586664
23 February 2022
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7408970
17 November 2021
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7354428
29 October 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7342111
27 August 2020
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7043953
13 November 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6851598
31 October 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6573058
30 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6402762
25 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6399593
21 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6396339
20 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6395816
16 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6392776
16 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6392937
11 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6390643
10 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6389247
9 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6389292
8 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6387612
28 December 2017
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6330773
25 October 2017
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6314259
28 June 2017
Deficiency Check · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6190511
20 December 2016
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6062611
4 November 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6037364
26 October 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6030695
21 September 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6005796
12 September 2016
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5999783
27 May 2016
Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5923598
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 October 2022
Resolved
46 CFR 181.300(b)
On a vessel of not more than 65 ft in length carrying more than 49 passengers, the minimum capacity of the fire pump must be 50 gpm at a pressure of not less than 60 psi. Vessel fire/bilge pump was non operational during inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2022
Resolution: Operational pump was installed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 November 2021
Resolved
Repairs or alterations to the hull must not be made without the approval of the cognizant [name withheld] drydock exam, the following areas of concern were identified:
-Lateral crack throughout rudder
-Large portion of rudder post sleeve missing/wasted
-Puncture in PORT rubrail
-Wastage in lower PORT side of bulkhead between compartments 5 and 6
Submit a proposal to this office detailing repairs to address above issues.
46 CFR 176.700(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2022
Resolution: Proposal was submitted to the approval of [name withheld] were conducted IAW repair proposal to the satisfaction of the attending CG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 November 2021
Resolved
The marine inspector may require the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever condition of the shafting and bearings are in question. Percentage wastage of cutlass bearing could not be determined upon initial examination. MI will attend vessel when propeller removed to determine if shaft must be pulled to gauge cutlass bearing wastage.
46 CFR 176.670(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2022
Resolution: Replacement of the cutlass bearing was conducted to the satisfaction of the attending CG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 October 2021
Resolved
46CFR 176.25-50(b): At each inspection for certification and reinspection the marine inspector shall examine spaces to see there is no accumulation of oil or other matter which might create a fire hazard. Fuel line was leaking fuel at the fuel shutoff valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2021
Resolution: Vessel operator face timed with CG marine inspector to show satisfactory repair of the fuel line.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 October 2021
Resolved
46 CFR 176.25-25: At each initial and subsequent inspection for certification and reinspection the firefighting equipment of all vessels shall be inspected and deficiencies found shall be corrected. Vessel was unable to demonstrate proper operation of the fixed fire extinguishing equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2021
Resolution: Vessel operator face timed with CG marine inspector to show satisfactory operation of the fixed fire extinguishing system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 October 2021
Resolved
46 CFR 176.25-5 (2): At each initial and subsequent inspection for certification the marine inspector shall examine and test by operation all watertight closures in the hull, decks, and bulkheads. Vessel's hatch covers #5 & #6 and their corresponding rings need tp be repaired /replaced prior to the completion of the next scheduled drydock.
Action required: 705 - Other - as specified
Resolved 23 February 2022
Resolution: Repair Proposal was submitted to the approval of [name withheld] were conducted IAW repair proposal to the satisfaction of the attending CG Marine Inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 October 2017
Resolved
First aid kit missing contents.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 8 November 2017
Resolution: Required first aid kit contents were made available.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 25 October 2017
Resolved
Emergency instructions were not ship specific.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 8 November 2017
Resolution: Ship specific emergency instructions were drafted and posted.
Engineering › Bilge Water Management System › Not Operational
Issued 25 October 2017
Resolved
Installed bilge pump was not capable of removing water from the second compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 28 December 2017
Resolution: Demonstrated proper operation of installed bilge system.
Engineering › Steering Gear System › Linkage
Issued 28 June 2017
Resolved
Provide repair proposal to idenditfy failed/wasted metal on steering quadrant broken free from rudder post.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2017
Resolved 30 June 2017
Resolution: Attending Coast Guard Marine Inspector verified the structural condition, installation and proper operation of newly rehabbed Steering Quadrant components, ALL SAT.
Construction/Loadline › Penetrations › Valve Flange
Issued 4 November 2016
Resolved
Install valve for overboard bilge piping located in the Aft Steering compartment (starboard side).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2016
Resolution: Verified installation and operation of overboard valve for Aft Steering bilge system
Construction/Loadline › Hull › Hull Plating
Issued 4 November 2016
Resolved
Replace/Renew deteriorated metal on the exterior hull IWO starboard / midships vent.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2016
Resolution: Verified proper installation of renewed metal on the exterior hull IWO Starboard / Midships vent.
Construction/Loadline › Hull › Bracket
Issued 4 November 2016
Resolved
Repair/Renew deteriorated gusset/support bracket system located in the Aft Steering compartment IWO starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2016
Resolution: Verified proper installation of renewed gusset/support system located in the Aft Steering compartment IWO starboard side.
Construction/Loadline › Hull › Hull Plating
Issued 4 November 2016
Resolved
Repair/Renew deteriorated hull sections located in the Aft Steering Compartment IWO portside/above the chine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2016
Resolution: Verified proper installation of renewed hull sections located in the Aft Steering compartment IWO portside/above.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 26 October 2016
Resolved
Ensure lagging on exhaust pipe is covered throughtout the entire length.
46 CFR 182.20-15
Action required: 705 - Other - as specified
Due 26 November 2016
Resolved 20 December 2016
Resolution: Special Note: Discovered that the exhaust system was a "wet exhaust" system. And therefore the lagging/heat shield is not required. Cleared this deficiency.
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 12 September 2016
Resolved
Vessel's transmission shaft seperated from flange assembly. Replace damaged transmission shaft.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2016
Resolution: Renewed the affected transimission shaft assembly. Conduct OP Test and Sea Trials with no unusal noise or vibration present, ALL SAT.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 12 September 2016
Resolved
Vessel had excessive oil in the bilge. Remove excessive oil from the bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2016
Resolution: Removed excessive oil from bilge, ALL SAT.
Engineering › Fuel Oil Service System › Filter
Issued 12 September 2016
Resolved
Diesel fuel was leaking excessively at the fuel filter line. Ensure leak is properly repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2016
Resolution: Renewed affected fuel filter line. Conducted OP Test with no leaks present, ALL SAT.
Electrical › Electric Supply System (service) › Cable
Issued 12 September 2016
Resolved
Reconnect/remove/dead end battery cable from terminal leading to engine starter that was disconnected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2016
Resolved 15 September 2016
Resolution: Remove the dead end battery cable that was previously discovered leading for the terminal to engine starter. All Sat to the satisfaction of the attending Coast Guard Marine Inspector. that was disconnected.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 27 May 2016
Resolved
Clean and Discharge all oil waste to an approved discharge facility.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2016
Resolved 27 May 2016
Resolution: Oily waste removed prior to departure.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 May 2016
Resolved
Endure all wiring is supported with approved clips and supported away from bilge and other hazards.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2016
Resolved 14 June 2016
Resolution: Attended vessel and cleared above deficency.
Fire Fighting › Fire Pumps › Arrangement
Issued 27 May 2016
Resolved
Relocate all items stored on top of fire pump so that it is accessible at all times.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2016
Resolved 27 May 2016
Resolution: Above deficiency cleared prior to departure from vessel.