← All vessels
CINNAMON JO
CINNAMON JO is a 1954 passenger barge (inspected). The Coast Guard has recorded 29 inspections since 1985, most recently in February 2008, along with 25 deficiencies.
Records from 1985 to 2008. Most recent: inspection, 1 February 2008.
- Built
- 1954
- Last inspected
- 1 February 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
268220
WYC8686
42967
Flag
UNITED STATES
—
Maury page id
psix-42967
Inspections, by type
…with no type recorded2
Years with a record
19 calendar years (1985–2008)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Net Ton
26 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 29
1 February 2008
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3140287
24 July 2002
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1651718
11 July 2001
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1437930
17 August 2000
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1052533
10 July 2000
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1384503
13 May 1999
Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1458633
10 March 1999
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1440101
3 June 1998
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 791749
24 April 1998
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1123849
9 March 1998
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1378300
10 March 1997
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1448877
3 May 1996
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1407666
27 March 1995
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1142225
24 May 1994
Hull Examination · Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1170282
2 March 1994
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 854768
11 March 1993
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1141603
16 November 1992
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 961352
15 April 1992
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1257994
26 February 1992
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1317485
4 April 1991
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1233476
6 March 1991
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1212990
13 March 1990
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 911544
10 May 1989
Re-Inspection · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 889839
3 February 1989
Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 899278
13 March 1988
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1027759
17 March 1987
Re-Inspection
Physical examination · MSO NASHVILLE · Activity 1017968
24 March 1986
Re-Inspection
Physical examination · MSO NASHVILLE · Activity 1303604
6 June 1985
Type not recorded
No type recorded · MSO NASHVILLE · Activity 1289856
14 March 1985
Type not recorded
No type recorded · MSO NASHVILLE · Activity 1288040
Deficiency record · 25
Construction/Loadline
Issued 10 July 2000
Resolved
Maintain all void spaces in a dry condition, all void spaces are to be checked for water on a daily basis before vehicle/passenger operations are conducted.
Documentation
Issued 10 July 2000
Resolved
Maintain a monthly fire, abandon ship and man overboard training log to include date of drill, scenario of drill and master and deck hand participating in drill. All drills are to be conducted at least once a month.
Documentation
Issued 10 July 2000
Resolved
Provide proof of compliance with 46 CFR Part 16 Chemcial Testing requirements for licensed master and deck hand.
Lifesaving
Issued 10 July 2000
Resolved
Provide written, posted instructions for man overboard, fire and abandon ship evolutions. (Emergency Checkoff List for Passengers)
Lifesaving
Issued 10 July 2000
Resolved
Provide vessel with a boathook to assist deckhand in recovering person on the water.
Lifesaving
Issued 10 March 1999
Resolved
SEPARATE CHILDRENS PFDS FROM ADULT PFDS IN STOWAGE BOXES.
Lifesaving
Issued 10 March 1999
Resolved
POST DONNING INSTRUCTIONS FOR THE PFDS.
Lifesaving
Issued 10 March 1999
Resolved
ATTACH RETROREFLECTIVE MATERIAL TO RING BOUY IN EACH QUADRANT.
Electrical
Issued 24 May 1994
Resolved
INSTALL CRIMP ELECTRICAL CONNECTORS IN PLACE OF TWIST CONNECTORS ON ALL WIRING IN JUNCTION BOXES.
Electrical
Issued 24 May 1994
Resolved
REPAIR AND SECURE BROKEN CONDUIT NEXT TO PFD STORAGE BOX.
Electrical
Issued 2 March 1994
Resolved
PROVIDE COVER PLATE ON ELECTRICAL JUNCTION BOX FOR STARBOARD NAVIGATION LIGHTING.
Lifesaving
Issued 2 March 1994
Resolved
REMOUNT RING BUOY WATERLIGHT BRACKET WITH FIXED CONNECTORS.
Fire Fighting
Issued 2 March 1994
Resolved
REPLACE EXISTING FIRE HOSE WITH 50' OF COMMERCIAL GRADE HOSE AND PROVIDE FIRE NOZZLE AS PER 46 CFR 181.15-10.
Construction/Loadline
Issued 2 March 1994
Resolved
ATTACH STRAINERS ON ENDS OF BILGE PUMP HOSES AS PER 46 CFR 182.25-5.
Lifesaving
Issued 2 March 1994
Resolved
REPLACE REPAIRED RING BUOY AND THROWLINE WITH APPROVED AND ACCEPTABLE RING BUOY.
Electrical
Issued 2 March 1994
Resolved
REPAIR LOOSE ELECTRICAL CONDUIT CONNECTIONS AT JUNCTION BOXS AND SECURE BROKEN CONDUIT NEXT TO PFD STORAGE BOX.
Construction/Loadline
Issued 2 March 1994
Resolved
INSTALL FIXED BILGE PIPING SYSTEM WITH POWERED BILGE PUMP SYSTEM AS PER 46 CFR 182.25.
Lifesaving
Issued 2 March 1994
Resolved
REPAIR PFD STORAGE BOX BY REWELDING CLOSURE LID HINGES AND REWELDING BOX BRACKETS. CLEANOUT BOTH PFD STORAGE BOXS AND MODIFY TO KEEP BOX BOTTOMS DRY.
Electrical
Issued 2 March 1994
Resolved
REMOVE OLD GROUNDING CABLES BETWEEN FERRY AND TOWING VESSEL.
Electrical
Issued 2 March 1994
Resolved
INSTALL CRIMP ELECTRICAL CONNECTORS IN PLACE OF TWIST ON CONNECTORS IN JUNCTION BOXS.
Lifesaving
Issued 26 February 1992
Resolved
POST EMERGENCY CHECK OFF LIST AND GARBAGE POLLUTION PLACARD.
Lifesaving
Issued 26 February 1992
Resolved
NUMBER OF PASSENGERS ALLOWED ON BOARD LIMITED TO 12 UNTIL 8 ADDITIONAL NEW ADULT SIZE PFD, OR EXISTING 8 ARE FITTED WITH REQUIRED REFLECTIVE TAPE, AREPROVIDED ON BOARD.
Construction/Loadline
Issued 10 May 1989
Resolved
BOTTOM PLATE THIN IN THE AREA OF THE TRANSITION KNUCKLE. RENEWED 2 EA SECTIONS 6'X30' OF 1/2" BOTTOM PLATE IN WAY OF WORN AREA.
Construction/Loadline
Issued 3 February 1989
Resolved
3/8" HOLE IN TRANSITION KNUCLKE IN THE PORT BOW CORNER 3" INBOARD OF THE CHINE. TEMPORARY REPAIR ACCOMPLISHED WITH A 12"X12" DOUBLER. PERMANENT REPAIRS ARE TO BE ACCOMPLISHED TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR AT THE NEXT DRYDOCK.
Fire Fighting
Issued 14 March 1985
Resolved
PORTABLE FIRE EXTINGUISHERS NOT PROPER SIZE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.