← All vessels
CABALLO BUCEFALO
CABALLO BUCEFALO is a 1980 research vessel. The Coast Guard has recorded 27 inspections since 1995, most recently in November 2008, along with 29 deficiencies and 4 operational controls.
Records from 1995 to 2008. Most recent: operational control imposed, 10 November 2008.
- Built
- 1980
- Last inspected
- 10 November 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 29 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7904841 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
XCAE5
429683
Flag
MEXICO
—
Maury page id
psix-429683
Inspections, by type
…with no type recorded18
Years with a record
11 calendar years (1995–2008)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it2285 - Regulatory (Subpart C or D), Gross Ton
686 - Regulatory (Subpart C or D), Net Ton
1011 - Dead Weight, Ton
3014 - Displacement, Ton
686 - Regulatory (Subpart C or D), Net Ton
1011 - Dead Weight, Ton
3014 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
10 November 2008
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3360447
16 October 2008
ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3345871
14 October 2008
PII Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3344791
15 September 2005
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2492979
24 May 2005
MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2366261
29 January 2005
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2284291
2 November 2004
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2234957
22 June 2004
ISM Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2107081
1 October 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1918934
30 September 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1917434
26 September 2003
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1913940
5 July 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1867086
22 October 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 294901
28 September 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 294351
14 July 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 143045
30 September 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 433324
18 May 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 215148
11 August 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 419190
27 March 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 526889
11 November 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 6991
4 July 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 156491
6 April 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 402316
6 December 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1187546
6 May 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 390610
11 November 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 25164
13 October 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1448721
14 September 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 382757
Deficiency record · 29
Lifesaving › Launching Appliances › Davit
Issued 14 October 2008
Resolved
Lifeboat Structural members are corroded. All life saving appliances shall be kept in working order in accordance with SOLAS 74 ch III reg 5
Electrical › Lighting (service) › Lighting Fixture
Issued 14 October 2008
Resolved
Electric wiring exposed throughout the vessel. All exposed metal parts and wires shall be secured and grounded in accordance with SOLAS ch II-I reg 27.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 14 October 2008
Resolved
Vessel's paint locker is not equipped with a fixed fire extinguishers equipment. Paint lockers and flammable liquid lockers shall be protected by an appropiate fire extinguishers arrangement in accordance with SOLAS cons. ed 2001 Ch II-II reg 18.7
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 October 2008
Resolved
Vessel failed to submit a Nontank vessel response plan IAW title 33 United States Code part 1321(j)(5). The Vessel is ordered under 33CFR160.111 to refrain from all internal and external transfers of petroleum products until receipt of submission and intial review of a Nontank Vessel Response Plan by Coast Guard Headquarters.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 24 May 2005
Resolved
The 220 volt panel has dead ground. Make repairs to the satisfaction of class.
Engineering › Steering Gear System › Piping
Issued 24 May 2005
Resolved
The steering gear flat has excess water and hydraulic fluid on system and deck causing a hazardous condition. Clean hazardous condition and maintain cleanliness prior to departure.
Engineering › Steering Gear System › Pump
Issued 24 May 2005
Resolved
No.1 steering gear pump shaft guard is missing bolt that is causing the guard to rub shaft. Make repairs to the satisfaction of class.
Engineering › Steering Gear System › Follow-up Assembly
Issued 24 May 2005
Resolved
During steering test vessel's non-follow up controls failed. (When Captain switches to NFU mode the vessel's rudder swings to 40 degrees PORT and will not move). Make repairs and prove proper operation to the satisfaction of class.
Fire Fighting › International Shore Connection › Gasket
Issued 24 May 2005
Resolved
During the course of the inspection vessel was found not to have a gasket for the International Shore Connection. Make proper replacement to the satisfaction of class.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 May 2005
Resolved
Found the illumination light for the rudder angle indicator not to be properly lit. Make repairs and prove illumination to the satisfaction of class.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 24 May 2005
Resolved
During PSC inspection found compass deviation table not to be current. Captain states new table will be made and posted during sea trials ( 1 week). Make proper arrangements to the satisfaction of class.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 24 May 2005
Resolved
Found no light in hospital bathroom and hospital space to be in complete disarray. Properly store all equipment found on hospital bed, floor, and bulkheads. Make proper arrangement to the satisfaction of the Flag state administration.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 24 May 2005
Resolved
Found toilet on bridge to be inoperable-creates unsanitary condition. Make repairs to the satisfaction of the Flag state administration.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 24 May 2005
Resolved
Vessel has no "Inland Rules of the Road" or equivalent onboard. Make proper replacement to the satisfaction of class.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 24 May 2005
Resolved
Vessel has outdated SOPEP onboard. Make proper updates to the satisfaction of class.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 May 2005
Resolved
Fire Control Plan not current. New Fire Control Plan was delivered onboard during inspection but DNV surveyor still has to verify, approve, and stamp. Make proper checks and posting to the satisfaction of class.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 2 November 2004
Resolved
Vessel is currently in a lay up status and prior to operating in the US must provide valid class certificates and undergo an Annual Fright Exam.
Construction/Loadline › Markings
Issued 26 September 2003
Resolved
Load line mark and class markings were worn and faded on port side of vessel. Master stated marking would be painted once underway since vessel was moored to port. All other markings were bright and readable. LEGACY COMPONENT DESC: Load Line Mark
Navigation › Emergency Steering
Issued 26 September 2003
Resolved
Block diagram for emergency steering was missing from bridge. Master will fax/email copy to MSU Galveston prior to departure from port. LEGACY COMPONENT DESC: Communications to Emergency Steering
Lifesaving
Issued 28 September 2001
Resolved
PRIOR TO NEXT US PORT REMOVE ALL STORED GEAR FROM HOSPITAL SPACE. ILO 147
Construction/Loadline
Issued 28 September 2001
Resolved
PRIOR TO NEXT US PORT REPLACE HATCH GASKET TO FORWARD STORAGE SPACE. ICLL 6 REG 13-16
Lifesaving
Issued 28 September 2001
Resolved
PRIOR TO NEXT US PORT REPAIR/REPLACE LIMIT SWITCHES ON PORT AND STARBOARD LIFEBOAT DAVITS. SOLAS 74 UNAMMENDED III REG 36(k)
Fire Fighting
Issued 30 September 1999
Resolved
Provide satisfactory deck fire fighting foam analysis prior to departing port.
Engineering
Issued 6 May 1996
Resolved
FUEL TRANSFER PROCEDURES NOT ABOARD.
Accommodation/Occupational Safety
Issued 6 May 1996
Resolved
MSD BYPASS VALVE NOT LOCKED.
Engineering
Issued 6 May 1996
Resolved
NO CONTAINMENTS AROUND FUEL OIL FILL CONNECTIONS AND VENTS.
Engineering
Issued 6 May 1996
Resolved
OILY WATER SEPARATOR INOPERATIVE.
Unknown
Issued 6 May 1996
Resolved
GARBAGE LOG NOT ABOARD.
Engineering
Issued 14 September 1995
Resolved
OILY WATER SEPERATOR INOPERABLE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National