Records from 1995 to 2011. Most recent: inspection, 11 February 2011.
Inspection history · 39
11 February 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3943594
27 January 2011
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3931545
26 January 2011
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3933630
21 September 2010
NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3850712
13 September 2010
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3849500
8 September 2010
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3845201
14 May 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3475948
29 April 2009
ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3462865
11 August 2008
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3295888
8 January 2008
MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3126999
8 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2924890
3 January 2007
PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2849624
27 April 2006
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2638434
8 November 2005
Random ISPS/MTSA/PSC · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2529955
13 September 2005
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2491466
8 September 2005
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2487631
17 June 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2393724
14 June 2005
NPV Safety Exam · ISPS II Exam · Loadline Exam · MARPOL Annex V Examination · STCW 95 Exam · MARPOL Annex I Examination · ILO-147 Exam · Ballast Water Examination · ISM Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2391128
15 June 2004
MTSA/ISPS Verification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2099045
9 June 2004
Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2093652
10 March 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2022226
13 June 2003
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1815760
9 June 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1813491
3 June 2003
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1808670
3 April 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1600804
9 November 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 295401
12 April 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 289102
17 October 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 283106
10 May 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 277743
24 February 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 275170
30 December 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 424099
24 February 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 413168
15 December 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 410939
17 January 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 399744
10 January 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 399430
26 November 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 710320
8 November 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 397470
5 December 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 385496
31 August 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 382232
Documentation › Logs/Records › Oil Record Book
Issued 21 September 2010
Resolved
1710- Oil Record Book- C/E is entering data for a incinerator waste oil tank which is not listed on the IOPP section 3.1. Provide clarification from the class society on the status of this tank.-MARPOL 73/78 Annex I/17
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 September 2010
Resolved 30 September 2010
Resolution: Received class report from Nippon Kaiji Kyokai satisfying requirement.
Engineering › Lubricating Oil Service System › Cooler
Issued 21 September 2010
Resolved
1499-Other(Prop. & Aux. Machinery)-The saltwater discharge line on the main engine lube oil cooler has a wooden plug installed in one of the ports. The port and piping in this area are severely deteriorated.-SOLAS 2004 cons. II-1/26
Action required: 705 - Other - as specified
Due 28 September 2010
Resolved 30 September 2010
Resolution: Received class report from Nippon Kaiji Kyokai satisfying requirement.
Engineering › Bilge Water Management System › Piping
Issued 21 September 2010
Resolved
1440- Bilge pumping arrangements- A soft patch is installed on the fire/ballast pump overboard discharge pipe. When soft patch is removed, a steady stream of water is emitted at approximately 4-5 gallons a minute.-SOLAS 74 I/11
Action required: 705 - Other - as specified
Due 28 November 2010
Resolved 26 January 2011
Resolution: RCVD NKK report & cleared Def.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 21 September 2010
Resolved
0999-Other(Safety in General)-Twelve 6 gallon conatiners of gasoline were stored in the steering gear.
Action required: 705 - Other - as specified
Due 21 September 2010
Resolved 21 September 2010
Resolution: Crew removed and discharged to shore via facility as witnessed by CG Inspector.
Electrical › Electric Generation Source (emergency) › Ground Detection
Issued 8 January 2008
Resolved
The 100V emergency distribution panel is displaying a ground.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2008
Resolution: Received class report attesting that the 100v emergency distribution panel is no longer showing a ground.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 8 January 2008
Resolved
The bilge alarm detection system is inoperable. Vessel shall submit documentation attesting to the repairs and operation of both bilge high level alarms.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2008
Resolution: Received tech report attesting to the proper repairs and full operation of the bilge high level alarms.
Documentation › Certificates/Documents › IOPP Certificate
Issued 8 January 2008
Resolved
The vessel is using its fuel oil settling tank as a slop tank. This tank is not indicated on the IOPP certificate. Vessel shall submit documentation from the certificate issuing authority attesting to the proper use of the vessel's slop tanks and proper record of discharging ashore.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2008
Resolution: Received class report attesting that all piping lines and bilge system is installed according to the IOPP certificate, that all tanks are being used correctly and that the improper records have been rectified. All is satisfactory.
Construction/Loadline › Structures › Trunk
Issued 8 November 2005
Resolved
Forward fan trunk port side on main deck is corroded/wasted at connection to deck
Action required: 705 - Other - as specified
Due 8 December 2005
Resolved 16 December 2005
Construction/Loadline › Structures › Deck Plating
Issued 8 November 2005
Resolved
steps to anchor machinery catwalks, main deck, are wasted.
Action required: 705 - Other - as specified
Due 8 December 2005
Resolved 16 December 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 November 2005
Resolved
asbestos insulation in battery room is damaged and breaking down. insulation shall be repaired or removed by a qualified contractor not ships crew.
Due 16 December 2005
Resolved 16 December 2005
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 14 June 2005
Resolved
Structural fire boundaries do not meet SOLAS requirements in way of two storage rooms and battery room located on main deck and in the emergency fire pump suction line in way of the aft engine room bulkhead. Deficiencies must be corrected to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 September 2005
Resolution: RECIEVED SATISFACTORY CLASS REPORT BY FAX. ALL IS WELL.
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 June 2003
Resolved
Space under bed in hospital being used for storage. LEGACY COMPONENT DESC: Hospital space
Due 3 July 2003
Resolved 13 June 2003
Resolution: VERIFIED CORRECT DURING DEFICIENCY FOLLOW UP EXAM. DEFICIENCY CLEARED.
Fire Fighting › Structural Fire Protection - General
Issued 3 June 2003
Resolved
Fire door for pass-through window between kitchen and crew mess is missing. LEGACY COMPONENT DESC: Fire door
Due 3 July 2003
Resolved 13 June 2003
Resolution: VERIFIED CORRECT DURING DEFICIENCY FOLLOW UP EXAM. DEFICIENCY CLEARED.
Accommodation/Occupational Safety › Occupational Safety
Issued 3 June 2003
Resolved
Lights missing globes and guards throughout vessel. LEGACY COMPONENT DESC: Light guards
Due 3 July 2003
Resolved 13 June 2003
Resolution: VERIFIED CORRECT DURING DEFICIENCY FOLLW UP EXAM. DEFICIENCY CLEARED.
Lifesaving
Issued 12 April 2001
Resolved
REMOTE LAUNCHING MECHANISM LINE PARTED DAMAGING FITTINGS USED IN CONNECTIONWITH THE LOWERING OF THE LIFEBOAT. SOLAS 74 CHP.III REG. 48 (1.4)(1.8)
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Fire Fighting
Issued 15 December 1997
Resolved
Provide safety chain at emergency fire pump outer railing in accordance with ILO 147.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Electrical
Issued 15 December 1997
Resolved
Emergency generator fuel shut-off valve outside space is missing which is not in accordance with Solas 74, Chapter II-2, Regulation 15.2.5.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Fire Fighting
Issued 15 December 1997
Resolved
No fireproof lifeline provided with fireman's outfits in accordance with Solas 74, Chapter II-2, Regulation 17.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Electrical
Issued 15 December 1997
Resolved
Repair paint store explosion proof light in accordance with Solas 74, Chapter II-2, Regulation 18.7.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Navigation
Issued 8 November 1996
Resolved
THE VESSEL'S CHARTS WERE NOT CURRENTLY CORRECTED. THE LATEST CORRECTION ONTHE CHARTS WERE 06/1996. THE NOTICE OF MARINERS ARE UP TO 43/1996. THE VESSEL'S AGENT PROVIDED THE VESSEL WITH NEW AND CORRECTED CHARTS.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Lifesaving
Issued 8 November 1996
Resolved
THE VESSEL'S BOW LIFE RAFT'S CASING WAS CRACKED. THE CASING WAS CRACKED BYWAVES DURING A ROUGH STORM THAT THE VESSEL HAD GONE THROUGH IN TRANSITING THE PACIFIC FOR THIS VOYAGE. THE VESSEL WAS REQUIRED TO REPAIR THE CASING PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 13 January 1997
Resolved 13 January 1997
Navigation
Issued 8 November 1996
Resolved
THE M/V REINA ROSA'S COAST PILOT FOR THE PORT OF LOS ANGELES-LONG BEACH WASNOT CURRENTLY CORRECTED. THE VESSEL'S AGENT PROVIDED THE VESSEL WITH A NEWCURRENTLY CORRECTED COAST PILOT FOR THE PORT OF LA-LB.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Navigation
Issued 8 November 1996
Resolved
THE VESSEL'S LIGHT LIST WAS NOT CURRENTLY CORRECTED. THE LATEST CORRECTIONON THE LIGHT LIST WAS 06/1996. THE NOTICE OF MARINERS ARE NOW AT 42/1996. THE VESSEL'S AGENT PROVIDED THE VESSEL WITH A NEW AND CORRECTED LIGHT LIST.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Navigation
Issued 31 August 1995
Resolved
Place onboard the vessel a copy of the Inland Navigation Rules prior to departure from port._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Fire Fighting
Issued 31 August 1995
Resolved
Remove hold back devices on fire doors to emergency steering/fire pump compartment from the engine room and accomodation spaces._x001C_ _x001C_ SOLAS CH II-2, REG 47 (2)
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Electrical
Issued 31 August 1995
Resolved
Provide a rubber mat for the emergency generator electrical panel._x001C_ _x001C_ _x001C_ CH II-1, REG 40(1.3)
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Fire Fighting
Issued 31 August 1995
Resolved
Provide a guard for the exposed belt on the emergency fire pump prior to next U.S. port call after foreign voyage. _x001C_ (Itinerary is PROMS-LOSMS-SFCMS-FOREIGN-U.S.)_x001C_ ILO 147
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995