MAURY USCG vessel records Sign in
← All vessels

MOBILE BAY

MOBILE BAY is a 1954 tank ship. The Coast Guard has recorded 62 inspections since 1981, most recently in June 1990, along with 50 deficiencies.

Records from 1981 to 1990. Most recent: inspection, 29 June 1990.

Built
1954
Last inspected
29 June 1990
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5388275 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-42993

Inspections, by type

…with no type recorded37
Years with a record 9 calendar years (1981–1990)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 36 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11485 - Regulatory (Subpart C or D), Net Ton
31875 - Dead Weight, Ton
18810 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KEHJMMSI not assigned · expired · compulsorily equipped · granted 27 October 1988, cancelled 27 October 1993
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 62

29 June 1990 Permit to Proceed
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 913934
29 June 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 917362
9 March 1990 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 902916
27 February 1990 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 904533
2 February 1990 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 909177
1 February 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 922942
20 January 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 927348
8 December 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 499459
19 November 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 904398
13 October 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1037003
14 September 1989 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 891106
20 June 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 482262
15 March 1989 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 894671
19 January 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 462762
26 October 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1200618
1 July 1988 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 896113
14 May 1988 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198349
3 May 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1041500
7 March 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 444203
11 February 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1019832
28 December 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323414
8 December 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1002611
7 November 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 485734
7 November 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1022891
7 November 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1329252
26 October 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1325475
22 September 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1009797
28 August 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1005093
12 August 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1338765
28 July 1987 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1031320
16 May 1987 Deficiency Check · Drydock Extension · MARPOL Annex II Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1026417
30 April 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 483988
22 December 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1335788
21 October 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1012983
20 October 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 484178
29 August 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1007865
14 August 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 984987
14 August 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1309922
3 August 1986 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1305486
28 July 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 994824
11 July 1986 MARPOL Annex I Examination · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 993546
2 May 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1294717
24 April 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 478918
17 April 1986 Examination of Repairs
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 999960
31 March 1986 Damage Survey · Examination of Repairs
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1001483
18 December 1985 MARPOL Annex I Examination · Examination of Repairs
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1301251
11 October 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 513335
29 July 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 303385
28 May 1985 Credit Drydock · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1287915
24 March 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 508929
11 February 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 524273
31 January 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1288451
15 January 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1283912
6 December 1984 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1284730
23 October 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 468957
8 September 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283649
21 June 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 296731
17 May 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973984
29 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281184
28 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973433
10 October 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971731
12 July 1981 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1277537

Deficiency record · 50

Engineering
Issued 2 February 1990 Resolved
RENEW 21 STEAM GENERATOR AND 2 FLOOR TUBES WHICH ARE PLUGGED (AS DEEMED NECESSARY BY ATTENDING CG MARINE INSPECTOR).
Condition: Unknown
Due 1 July 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 2 February 1990 Resolved
RENEW SUPER HEATER SUPPORT TUBE (FWD/INTERNALS SIDE) WHICH IS PLUGGED ON PORT BOILER.
Condition: Unknown
Due 1 July 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 1 February 1990 Resolved
REMOUNT EPIRB SO THAT IS WILL FLOAT FREE.
Condition: Unknown
Due 15 February 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 14 September 1989 Resolved
REPAIR AND PROVE PROPER OPERATION OF SOUND POWERED PHONE AT BOW LOOKOUT STATION.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Documentation
Issued 14 September 1989 Resolved
UPDATE AND SUBMIT FOR COAST GUARD APPROVAL, A FIRE CONTROL PLAN.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Construction/Loadline
Issued 14 September 1989 Resolved
RESTENCIL VESSEL'S NAME ON BOTH SIDES OF WHEELHOUSE USING AT LEAST 6' LETTERS.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Accommodation/Occupational Safety
Issued 14 September 1989 Resolved
REPAIR AND PROVE PROPER OPERATION OF VENT SHUTDOWN ON BRIDGE FOR FOWARD HOUSE.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Engineering
Issued 14 September 1989 Resolved
REPAIR AND CONDUCT OPERATIONAL TEST OF OILY WATER SEPARATOR.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Engineering
Issued 14 September 1989 Resolved
REPAIR AND PROVE PROPER OPERATION OF BILGE PUMP IN SHAFT ALLEY.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Electrical
Issued 14 September 1989 Resolved
INSTALL EXPLOSION PROOF FITTINGS FOR LIGHT IN PAINT LOCKER FOR ENGINEROOM.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Fire Fighting
Issued 14 September 1989 Resolved
SUBMIT CURRENT, SATISFACTORY FOAM ANALYSIS REPORT TO [name withheld], TX.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Documentation
Issued 1 July 1988 Resolved
SUBMIT A COPY OF THE FIRE EXTINGUISHING FOAM ANALYSIS REPORT.
Condition: Unknown
Due 1 July 1988
Resolved 1 July 1988
Fire Fighting
Issued 7 November 1987 Resolved
TEST IN THE PRESENCE OF A MARINE INSPECTOR THE CARDOX SYSTEM VENTILATION SHUTDOWNS
Condition: Unknown
Due 7 November 1987
Resolved 7 November 1987
Fire Fighting
Issued 26 October 1987 Resolved
TEST IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR THE CARDOX SYSTEM VENTILATION SHUTDOWNS.
Condition: Unknown
Due 26 October 1987
Resolved 26 October 1987
Navigation
Issued 26 October 1987 Resolved
MAKE PERMANENT REPAIRS TO THE 3 CM RADAR.
Condition: Unknown
Due 26 October 1987
Resolved 26 October 1987
Construction/Loadline
Issued 26 October 1987 Resolved
REMOVE THE SEVEN CEMENT PATCHES AT THE UPPER RIVETED BILGE SEAM IN NUMBER 2 STARBOARD CARGO TANK AND PERMANENTLY REPAIR THE WEEPING SEAM.
Condition: Unknown
Due 26 October 1987
Resolved 26 October 1987
Documentation
Issued 26 October 1987 Resolved
SUBMIT REVISED STABILITY INFORMATION RELATED TO THE SEGREGATED BALLAST SYSTEM INSTALLATION TO THE U. S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C.
Condition: Unknown
Due 26 October 1987
Resolved 26 October 1987
Engineering
Issued 26 October 1987 Resolved
OBTAIN AND MOUNT ON THE BOILER THE INFORMATION REQUIRED BY 46 CFR 52.01-140(B) AND (C).
Condition: Unknown
Due 26 October 1987
Resolved 26 October 1987
Construction/Loadline
Issued 26 October 1987 Resolved
REPLACE THE INOPERATIVE MEMORY CHIP IN THE OIL CONTENT METER.
Condition: Unknown
Due 26 October 1987
Resolved 26 October 1987
Construction/Loadline
Issued 26 October 1987 Resolved
CLEAN AND GAGE THE STARBOARD ENIGINE ROOM COFFERDAM TANK TOP, THE AFTER STARBOARD FUEL TANK BULKHEAD AND THE SIDESHELL IN THE FORWARD CORNER OF THE ENGINE ROOM IN THE VICINITY OF THE TEMPORARY REPAIR AND CONDUCT PERMANENT REPAIRS AS INDICATED BY THE GAGING.
Condition: Unknown
Due 26 October 1987
Resolved 26 October 1987
Construction/Loadline
Issued 26 October 1987 Resolved
REPLACE THE TWO WASTED BRACKETS THAT CONNECT THE BOTTOM PLATING TO THE TANK TOP IN THE STARBOARD ENGINE ROOM COFFERDAM UNDER THE TEMPORARY REPAIR.
Condition: Unknown
Due 26 October 1987
Resolved 26 October 1987
Engineering
Issued 22 September 1987 Resolved
MAKE PERMANENT REPAIRS TO THE REAR WALL HEADER BLOW DOWN PIPE.
Condition: Unknown
Due 22 September 1987
Resolved 22 September 1987
Deck/Cargo
Issued 28 July 1987 Resolved
WEIGHT TEST THE VESSEL'S BOOMS AND DISASSEMBLE ALL BLOCKS FOR INSPECTION.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Fire Fighting
Issued 28 July 1987 Resolved
PROPERLY PAINT AND MARK GENERAL ALARM BELL AT FORWARD BULKHEAD ENGINEROOM IN WAY OF OPERATOR PLATFORM.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Fire Fighting
Issued 28 July 1987 Resolved
MAKE OPERABLE GENERAL ALARM BELL FORWARD OF OFFICER'S MESS.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Fire Fighting
Issued 28 July 1987 Resolved
TEST IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR THE CARDOX SYSTEM PIPING, VENTILATION SHUTDOWNS AND ALARMS.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Lifesaving
Issued 28 July 1987 Resolved
PROVIDE EIGHT (8) ADDITIONAL EXPOSURE SUITS TO BRING VESSEL'S ALLOWANCE UP TO THE 44 REQUIRED BY THE COI. ALSO, PROVIDE LIGHTS FOR ALL EXPOSURE SUITSAS REQUIRED BY 46 CFR 33.38-1(A).
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Lifesaving
Issued 28 July 1987 Resolved
RENEW THE BEVEL GEARS TO THE FORWARD ARM OF THE #2 PORT LIFEBOAT DAVIT.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Construction/Loadline
Issued 28 July 1987 Resolved
RENEW OR REPAIR THE FOLLOWING DOGS: FROZEN DOG ON FORWARD CARGO HATCH; MISSING AND FROZEN DOGS ON PORT AND STARBOARD VENT TRUNKS TO BOSUN'S STORES; MISSING DOG ON AFT LAZZARETTE HATCH; TWO MISSING DOGS ON STARBOARD CARDOX WATERTIGHT DOOR; MISSING DOG ON A/C ROOM WATERTIGHT DOOR.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Deck/Cargo
Issued 28 July 1987 Resolved
REPAIR AND RENEW AS NEEDED THE FORWARD DIESEL PUMP ENGINE EMERGENCY SHUTDOWN BOX AND CONDUIT. PROPERLY MARK WHEN REPAIRED.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Deck/Cargo
Issued 28 July 1987 Resolved
RENEW THE HINGES ON THE PORT AND STARBOARD FIDDLY COVERS TO THE AFT PUMP ROOM.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Accommodation/Occupational Safety
Issued 28 July 1987 Resolved
RENEW THE BROKEN CATWALK STANCHION ON AFT CATWALK BETWEEN THE DECKHOUSES.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Deck/Cargo
Issued 28 July 1987 Resolved
RENEW AND REBUILD THE AFT CARGO PUMP ROOM FAN SWITCH LOCKER. PROPERLY MOUNT OR REMOVE SWITCHES THAT ARE NO LONGER IN USE.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Construction/Loadline
Issued 28 July 1987 Resolved
CROP TO GOOD METAL AND RENEW THE SHELTER DECK SIDE PLATING, PORTSIDE AMIDSHIP, IN WAY OF THE SIDE/DECK JOINT.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Navigation
Issued 28 July 1987 Resolved
PROVIDE A COMPASS LIGHT FOR THE MAGNETIC COMPASS AT THE MAIN STEERING STANDAS REQUIRED BY 33 CFR 164.35(B).
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Engineering
Issued 16 May 1987 Resolved
MAKE THE DC HEATER AVAILABLE FOR INTERNAL INSPECTION OR HYDROSTATIC TESTING AT NEXT DRYDOCKING.
Condition: Unknown
Due 16 May 1987
Resolved 16 May 1987
Engineering
Issued 16 May 1987 Resolved
OPEN ALL BOILER MOUNTS AT NEXT DRYDOCK INSPECTION [46 CFR 61.05-15(A)].
Condition: Unknown
Due 16 May 1987
Resolved 16 May 1987
Accommodation/Occupational Safety
Issued 3 August 1986 Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED OUTBOARD BULKHEAD AND OVERHEAD OF THEHOSPITAL ROOM AND ITS ASSOCIATED INTERNAL STRUCTURES AND EQUIPMENT TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 3 August 1986
Resolved 3 August 1986
Engineering
Issued 11 July 1986 Resolved
PROVIDE SECURING DOG FOR GOOSENECK VENT COVER ON FANTAIL.
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Fire Fighting
Issued 11 July 1986 Resolved
CONDUCT OPERATIONAL TEST OF STEAM SMOTHERING SYSTEM AS REQUIRED BY 46 CFR 31.10-18(I) IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR AT THE NEXT DRYDOCK EXAMINATION.
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Lifesaving
Issued 11 July 1986 Resolved
REMOVE AND PREPARE FOR INSPECTION THE BUOYANCY TANKS IN #3 & #4 LIFEBOATS. (46 CFR 33.25-20C).
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Lifesaving
Issued 11 July 1986 Resolved
WEIGHT TEST #2 LIFEBOAT. (46 CFR 33.01-27).
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Deck/Cargo
Issued 11 July 1986 Resolved
PREPARE PV VALVES FOR INSPECTION OR PROVIDE EVIDENCE OF INSPECTION.
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Deck/Cargo
Issued 11 July 1986 Resolved
IGS INDICATOR PANEL IN FWD CARGO OFFICE IS INOPERATIVE.
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Construction/Loadline
Issued 11 July 1986 Resolved
REPAIR/RENEW SCUTTLE HATCH IN WAY OF FWD DRY CARGO HOLD.
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Construction/Loadline
Issued 11 July 1986 Resolved
PROVE WATERTIGHT INTEGRITY OF CARGO PUMP DRIVE SHAFT IN WAY OF FORECASTLE DIESEL MACHINERY SPACE.
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Construction/Loadline
Issued 11 July 1986 Resolved
PROVE WATERTIGHT INTEGRITY OF FOLLOWING MAIN DECK W/T DOORS: AFT P/R P&S; MIDSHIPS HOUSE FWD END P & S; MIDSHIPS HOUSE AFT END P&S, AND CTR; FORE- CASTLE STBD AND CTR; FWD P/R FORE AND AFT.
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Engineering
Issued 11 July 1986 Resolved
PROVIDE AUDIBLE ALARM FOR BILGE ALARM ON THROTTLE PLATFORM IN E/R.
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Lifesaving
Issued 31 March 1986 Resolved
CROP OUT AND RENEW THE MOUNTING BRACKET FOR THE BOAT DAVIT, STARBOARD SIDE FORWARD. THIS REPAIR IS TO BE COMPLETED TO THE SATISFACTION OF A MARINE INSPECTOR.
Condition: Unknown
Due 31 March 1986
Resolved 31 March 1986
Construction/Loadline
Issued 28 May 1985 Resolved
PROVIDE APPROVED PLANS FOR INSTALLED SBT SYSTEM. UPDATED LOADING MANUAL & TRIM & STABILITY BOOKLET TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 28 May 1985
Resolved 28 May 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.