Records from 2016 to 2026. Most recent: inspection, 15 July 2026.
Inspection history · 21
15 July 2026
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8440356
7 August 2025
In-Service Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8208148
17 June 2025
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8194449
27 August 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8004991
28 November 2023
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7830533
5 July 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7744394
27 June 2023
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7724947
31 October 2022
Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7595966
3 August 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7521854
14 December 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7367465
19 August 2021
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7345328
17 June 2019
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6716689
30 May 2019
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6699802
24 July 2018
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6488928
12 July 2018
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6476811
25 May 2018
COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6416845
14 May 2018
Deficiency Check · Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6414684
1 December 2017
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6316394
28 April 2017
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6134673
13 May 2016
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5876287
26 April 2016
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5865325
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 August 2025
Resolved
A propulsion or auxiliary diesel engine may be air cooled or employ an air cooled jacket water radiator when installed in an enclosed or partially enclosed space for which ventilation for machinery cooling is provided, which complies with the requirement of § 182.465(b) Air-cooled propulsion and auxiliary diesel engines installed below deck, as permitted by § 182.420, must be fitted with air supply ducts or piping from the weather deck. The ducts or piping must be so arranged and supported to be capable of safely sustaining stresses induced by weight and engine vibration and to minimize transfer of vibration to the supporting structure. Prior to installation of ventilation system for such engines, plans or sketches showing machinery arrangement including air supplies, exhaust stack, method of attachment of ventilation ducts to the engine, location of spark arresting mufflers and capacity of ventilation blowers must be submitted to the cognizant OCMI for approval, and other necessary safeguards are taken so as not to endanger the vessel. Submit proposal to OCMI for adding intake ventilation for the 02 radiator cooled generators in the engine space. Once approved, make alterations prior to 2026 op season.
46 CFR 182.420 (e)(2)
46 CFR 182.465(b)
Action required: 705 - Other - as specified
Due 30 April 2026
Resolved 24 April 2026
Resolution: Examined installation of ventilation intake and test ran generators including high temp alarm function. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 August 2024
Resolved
Trash cans onboard are made from combustible materials.
Action required: 10 - Deficiency Rectified
Due 18 September 2024
Resolved 18 September 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 August 2024
Resolved
Additional 2A fire extinguisher needed at concession stand due to the addition of popcorn machine.
Action required: 10 - Deficiency Rectified
Due 18 September 2024
Resolved 18 September 2024
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 27 August 2024
Resolved
Labels needed for emergency fuel shut offs.
Action required: 10 - Deficiency Rectified
Due 18 September 2024
Resolved 18 September 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 June 2023
Resolved
Found vessel in need of an updated FCC License to reflect new owner and new call sign.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2023
Resolved 13 September 2023
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 27 June 2023
Resolved
Found vessel in need of a Great Lakes Agreement Inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2023
Resolved 13 September 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2023
Resolved
Found 120v flood lights installed on upper deck as docking lights to be missing shields and not of approved marine type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2023
Resolved 13 September 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 August 2022
Resolved
Vessel needs name and hailing port on bow and stern.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 19 July 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2022
Resolved
Chock batteries inside battery boxes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 28 November 2023
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 August 2022
Resolved
Light list and Coast Pilot need to be updated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 19 July 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 3 August 2022
Resolved
Vessel needs safer way to recover MOB. Current configuration uses a wooden ladder and a belt harness with block and tackle that when demonstrated was not realistic or practical. discussed multiple other options with owner.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 August 2022
Resolved 19 July 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 August 2022
Resolved
Vessel needs 3 more day and 3 more night distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 19 July 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 December 2021
Resolved
THE MASTER SHALL CONDUCT SUFFICIENT DRILLS TO ENSURE THAT ALL CREW MEMBERS ARE FAMILIAR WITH THEIR DUTIES DURING EMERGENCIES THAT NECESSITATE ABANDONING SHIP OR RECOVERY OF MAN OVERBOARD. THE OWNER MUST MAKE THE VESSEL AVAILABLE FOR ALL DRILLS REQUIRED BY THIS PART. DRILLS WERE NOT OBSERVED AS PART OF THIS ANNUAL. COORDINATE CG OBSERVATION OF REQUIRED DRILLS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 December 2021
Resolved
A VESSEL ON LAKES, BAYS, SOUNDS, OR RIVERS MUST CARRY 3 HAND RED AND THREE HAND SMOKE DISTRESS SIGNALS (OR ALLOWED SUBSTITUTIONS). 4 DISTRESS FLARES WERE FOUND ON BOARD, ALL OF WHICH WERE EXPIRED.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2022
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 December 2021
Resolved
AS APPROPRAITE FOR INTENDED VOYAGE, A VESSEL MUST CARRY ADEQUATE AND UP TO DATE CHARTS AND PUBLICATIONS. CHARTS AND PUBS LAST UPDATED IN 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 3 August 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 14 December 2021
Resolved
THE PERSON IN COMMAND OF A DOCUMENTED VESSEL MUST HAVE ON BOARD THAT VESSEL THE ORIGINAL COD. CURRENT COD NOT ON BOARD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 14 December 2021
Resolved
EACH VESSEL SUBJECT TO THE GLA MUST HAVE AN INSPECITON OF THE REQUIRED RADIO INSTALLATION AT LEAST ONCE EVERY 13 MONTHS. THIS INSPECTION MUST BE MADE WHILE THE VESSEL IS IN ACTIVE SERVICE OR WITHIN NOT MORE THAN ONE MONTH BEFORE THE DATE ON WHICH IT IS PLACED IN SERVICE.AGREEMENT IS EXPIRED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 4 August 2022
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 December 2021
Resolved
THE MOVEMENT OF A VESSEL SHALL BE UNDER THE DIRECTION OF THE MASTER AT ALL TIMES. SPECIAL ATTENTION SHOULD BE PAID TO...(8) MAGNETIC VARIATION AND DEVIATION ERRORS OF THE COMPASS. NO COMPASS DEVIATION CARD IS ON BOARD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 4 August 2022
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 14 December 2021
Resolved
THE MASTER SHALL ENSURE THAT ONE OR MORE PLACARDS MEETING THE REQUIREMENTS ARE DISPLAYED IN PROMINENT LOCATIONS IN SUFFICIENT NUMBERS SO THAT THEY CAN BE READ BY THE CREW AND PASSENGERS. GARBAGE PLACARD ON BOARD IS OUT OF DATE AND ALLOWS FOR THE DISHCARGE OF GARBAGE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: Up to date garbage placards have been obtained and posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 December 2021
Resolved
EACH BATTERY USED IN AN ITEM OF LIFESAVING EQUIPMENT MUST BE REPLACED AT THE ANNUAL INSPECTION IF THE IF THE EXPIRATION DATE HAS PASSED. BATTERY IN RING BUOY LIGHT EXPIRES THIS MONTH.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2022
Resolution: Battery has been replaced and tested satisfactorily
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 December 2021
Resolved
AN ADULT LIFE JACKET MUST BE PROVIDED FOR EACH PERSON CARRIED ON BOARD. 71 LIFEJACKETS WERE MISSING. TOTAL PERSONS ON BOARD COUNT IS HEREBY LIMITED TO 151 UNTIL MISSING LIFEJACKETS ARE REPLACED.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2022
Resolution: All 71 lifejackets have been restored to service, for a total of 222.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 December 2021
Resolved
EACH LIFE JACKET MUST BE MARKED WITH TYPE I RETROREFLECTIVE MATERIAL APPROVED IAW SUBCHAPTER Q. THE ARRANGEMENT OF THE MATERIAL MUST BE AS SPECIFIED IN IMO RESOLUTION A.658(16). MULTIPLE ADULT AND CHILD LIFE JACKETS WERE PLACED OUT OF SERVICE FOR WORN RETROREFLECTIVE MATERIAL.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2022
Resolution: Worn reflective material has been renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 December 2021
Resolved
EVERY PORTABLE FIRE EXTINGUISHER MUST BE SUPPLIED WITH A SUITABLE BRACKET WHICH WILL HOLD THE EXTINGUISHER SECURELY IN ITS STOWAGE LOCATION. MOUNTING BRACKETS DO NOT PROVIDE SUPPORT. PROVIDE BRACKETS FOR EACH EXTINGUISHER THAT MEETS THE REQUIREMENT AS PER THE MANUFACTURER.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: Brackets suitable for the marine environment have been installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 December 2021
Resolved
A VESSEL MUST CARRY EITHER A FIRST AID KIST APPROVED UNDER 160.041 OR A KIT WITH EQUIVALENT CONTENTS STOWED IN A SUITABLE WATERTIGHT CONTAINER. MULTIPLE ITEMS IN THE KIT WERE EXPIRED.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2021
Resolved
THE USE OF TWIST-ON TYPE WIRE NUTS IS PERMITTED UNDER THE FOLLOWING CONDITIONS: 1)CONNECTIONS MUST BE MADE WITHIN AN ENCLOSURE AND THE INSULATED CAP OF THE CONNECTOR MUST BE SECURED TO PREVENT LOOSENING DUE TO VIBRATION. 2)MAY NOT BE USED FOR MAKING JOINTS IN CABLE, FACILITATING A SPLICE, OR EXTENDING THE LENGTH OF THE CIRCUIT. WIRE NUTS WERE FOUND IN THE FORWARD STORAGE AREA. VERIFY THESE ARE NOT BEING USED AS MENTIONED IN (2) AND PROVIDE AND ENCLOSURE AS WELL AS SECURE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: Wire nuts in this location have been removed and replaced by a pressure type wire connector and shrink wrap.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 December 2021
Resolved
FUEL LINES MUST BE ANNEALED TUBING OF COPPER, HAVING
A MIN. THICKNESS OF .35" EXCEPT: (iii) WHEN USED, FLEX
NON METALLIC FLEX HOSE MAY BE USED IN FUEL OIL SYSTEMS ONLY WHERE FLEXIBILITY IS REQUIRED AND IN LENGTHS NOT
EXCEEDING 30" AND MUST HAVE FACTORY ASSEMBLED END FITTINGS. FLEXIBLE FUEL LINES >30" SECURED WITH A SINGLE HOSE CLAMP ARE BEING UTILIZED FOR THE FUEL SYSTEM ON THE GENERATORS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: USCG approved double wall flexible fuel lines have been installed. Factory assembled fittings are in place where possible.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 December 2021
Resolved
THAT PART OF THE EXHAUST SYSTEM BETWEEN THE POINT OF COOLING WATER INJECTION AND THE ENGINE MANIFOLD SHALL BE WATER-JACKETED OR EFFECTIVELY INSULATED. AREAS OF
INSULATION ON MAIN ENGINE ARE MISSING OUTER PROTECTIVE
COVER.
46 CFR 182.15-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: Insulation installed on the area of concern
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 December 2021
Resolved
VESSELS SHALL BE EQUIPPED WITH A SUITABLE NUMBER OF
PORTABLE BATTERY LIGHTS. FLASHLIGHT AT ENTRANCE TO
ENGINE ROOM IS NOT ADEQUATE OR READY.
46 CFR 184.30-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 4 August 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 December 2021
Resolved
ALL ESCAPE HATCHES SHALL BE MARKED ON BOTH SIDES
"EMERGENCY EXIT-KEEP CLEAR" ENGINE ROOM HATCH NOT
LABELED FROM OUTSIDE.
46 CFR 185.30-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 5 July 2023
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 December 2021
Resolved
REDUCTION GEAR FOUND WITH A OIL LEAK ON THE AFT OF THE ENGINE ROTATING SHAFT. NEW SEALS TO BE INSTALLED TO STOP LEAK.
46 CFR 176.25-10(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: Seal changed, leak secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 December 2021
Resolved
COOLANT LEAK ON REDUCTION GEAR PORT SIDE AFT LEADING INTO THE TUBE COOLER
46 CFR 176.25-10(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: Leak secured
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 December 2021
Resolved
COOLER ON AFT END OF REDUCTION GEAR FOUND WITH BROKEN BRACKETS AND SECURED WITH METAL ZIP TIES. TO BE PROPERLY SECURED.
46 CFR 176.25-10(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: Securing arrangements for the cooler have been repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 December 2021
Resolved
MISSING GUARD ON AFT AND FWD ENDS OF MAIN ENGINE
46 CFR 176.25-10(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: Guards put in place.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 December 2021
Resolved
OIL FOUND IN BILGES- TO BE CLEANED OUT AND TEST OF THE BILGE SUCTION LOCATED BELOW ENGINE.
46 CFR 176.25-50(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 16 June 2022
Resolution: Attended vessel and verified mimimal oil residue remained and tested bilge suction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 December 2021
Resolved
ALL MACHINERY ESSENTIAL TO THE ROUTINE OPERATION OF THE VESSEL SHALL BE CHECKED. RADIATOR COVER FOR FORWARD-PORT GENERATOR NOT PROPERLY SECURED.
46 CFR 176.25-10(a)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: Cover has been installed properly.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 December 2021
Resolved
FILLING AND SOUNDING PIPES SHALL BE SO ARRANGED THAT OVERFLOW OF LIQUID OR VAPOR CANNOT ESCAPE TO THE INSIDE OF THE VESSEL. ABANDONED FILL LINE FOUND WITH RUBBER END TO CAP IT OFF. PROVIDE A THREADED METAL CAP OF SUITABLE MATERIAL-CORROSION RESISTANT.
46 CFR 182.20-30(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: A threaded cap has been installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2021
Resolved
NON-CONDUCTING MATS OR GRATING SHALL BE PROVIDED ON DECK IN FRONT AND REAR OF SWITCHBOARDS.
46 CFR 183.10-15(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 26 January 2022
Resolution: Rubber mat installed
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 30 May 2019
Resolved
Make VHF radio DSC capable
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 December 2021
Resolution: VHF radio is now DSC capable. Observed MMSI number loaded into radio.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 30 May 2019
Resolved
Vessel is not conducting quarterly security drills, or training. Vessel shall conduct training and drills, and log in book.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2019
Resolved 12 June 2019
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 May 2018
Resolved
Complete satisfactory Man overboard fire and abandon ship drills.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2018
Resolved 12 July 2018
Resolution: Witnessed satisfactory drills.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 December 2017
Resolved
Complete Drydocking of vessel prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 December 2017
Resolved 30 May 2018
Resolution: Vessel completed satisfactory dry dock inspection25 May 2018.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 April 2017
Resolved
Complete fire and man over board drills.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 30 May 2018
Resolution: Reissued requirement to complete man overbaord and fire drill to the satisfaction of the attending USCG MI.
Engineering › Compressed Air System (start air) › Valve
Issued 26 April 2016
Resolved
Relief valve not seating. Renew or repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2016
Resolved 13 May 2016
Resolution: Relief valve renewed. Examined satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 26 April 2016
Resolved
Make permanent repairs to manifold to riser on p/s aft of main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 13 May 2016
Resolution: New gasket and blanketing installed. All sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 26 April 2016
Resolved
Make permanent repairs to air line control for main engine which was found to be leaking at fitting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2016
Resolved 13 May 2016
Resolution: Air line renewed. Witnessed proper operation of bridge shutdown to main engine.