RIVERBOAT LOUIS ARMSTRONG

RIVERBOAT LOUIS ARMSTRONG is a 1995 passenger vessel (inspected). The Coast Guard has recorded 166 inspections since 1995, most recently in August 2026, along with 213 deficiencies — 3 with no resolution recorded —.

Records from 1995 to 2026. Most recent: inspection, 4 August 2026.

Built
1995
Last inspected
4 August 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK9914
430290
Flag
UNITED STATES
368107760
Maury page id
psix-430290

Inspections, by type

…with no type recorded53
…past their stated due date2
Years with a record 25 calendar years (1995–2026)
The 166 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)287.3 ft × 60.0 ft × 14.5 ft
Registered tonnagegross 1,589 / net 995
ITC dimensions (L × B × D)287.3 ft × 60.0 ft × 14.5 ft
ITC tonnagegross 7,389 / net 2,385
BuilderJEFFBOAT · JEFFERSONVILLE, IN, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7389 - Convention (Subpart B), Gross Ton
1589 - Regulatory (Subpart C or D), Gross Ton
2385 - Convention (Subpart B), Net Ton
995 - Regulatory (Subpart C or D), Net Ton
2744 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK9914MMSI 368107760 · active · compulsorily equipped · granted 1 August 2019, expires 1 August 2029 · licensed under a name not among this hull’s recorded names (not shown)
WDF5710MMSI 367068210 · expired · compulsorily equipped · granted 16 September 2010, cancelled 21 November 2020 · licensed under a name not among this hull’s recorded names (not shown)
WCV2626MMSI 367068210 · terminated · compulsorily equipped · granted 22 September 2005, cancelled 14 September 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 166

4 August 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8455037
17 June 2025 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8160932
2 April 2025 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8104048
23 December 2024 Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8050333
6 November 2024 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8031538
30 July 2024 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7970551
20 February 2024 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7851717
10 October 2023 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7806202
25 July 2023 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7734491
14 June 2023 Deficiency Check · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7715918
9 March 2023 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7642110
22 November 2022 Periodic Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7598662
14 September 2022 Periodic Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7536417
13 June 2022 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7465443
21 April 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7428736
11 January 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7378438
22 September 2021 Administrative Inspection · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7318125
22 October 2018 Construction Oversight · MTSA Verification · Attraction Vessel Exam · COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6565939
28 February 2018 Internal Structural Exam · Examination of Repairs · Construction Oversight · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6363273
23 July 2012 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4387806
10 July 2012 MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4373315
12 January 2012 MTSA Verification · Administrative Inspection · Re-Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4224266
21 July 2011 Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4087397
4 January 2011 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3920890
21 October 2010 MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3875132
6 October 2010 COI Inspection · DAPI Audit · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3863180
8 September 2010 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3845805
11 January 2010 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3658754
8 April 2009 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3451541
5 February 2009 Internal Structural Exam · Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3413280
9 October 2008 MTSA Verification · COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3342309
15 July 2008 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3269950
17 April 2008 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3188756
17 January 2008 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3132667
11 October 2007 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3077768
17 September 2007 Hull Examination
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3358278
16 July 2007 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2996871
16 April 2007 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2908949
17 January 2007 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2859679
12 October 2006 COI Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2802169
17 July 2006 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2718021
13 June 2006 In-Service Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2680464
21 April 2006 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2630212
17 January 2006 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2568667
13 October 2005 COI Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2530005
20 July 2005 Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2434165
18 April 2005 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2353732
2 March 2005 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2302649
19 January 2005 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2279914
19 November 2004 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3366764
13 October 2004 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2220997
2 September 2004 Administrative Inspection
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2184127
25 August 2004 Deficiency Check · MTSA Verification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2177498
15 July 2004 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2140187
14 April 2004 Quarterly Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2045143
31 March 2004 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2071046
15 January 2004 Quarterly Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1986328
14 October 2003 COI Inspection · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1928101
26 September 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1913575
18 September 2003 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1907603
29 July 2003 Quarterly Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1866015
29 April 2003 Quarterly Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1784875
14 February 2003 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1746579
8 January 2003 Quarterly Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1729370
15 October 2002 Deficiency Check · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1698293
29 August 2002 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1668173
15 August 2002 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1662388
18 July 2002 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1648524
9 July 2002 Quarterly Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1644595
9 July 2002 Quarterly Examination · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1648510
17 January 2002 Quarterly Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1480746
18 October 2001 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1395849
10 September 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1072919
26 July 2001 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1366550
9 July 2001 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 169349
11 April 2001 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1439198
12 March 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1060794
31 January 2001 Drydock Extension
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1469985
23 January 2001 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1422000
19 October 2000 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1467257
20 July 2000 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1429388
19 April 2000 Deficiency Check · Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1406700
27 January 2000 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1406640
17 November 1999 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 810841
19 October 1999 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1454731
30 September 1999 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1346481
17 September 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 784670
31 August 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 179132
30 August 1999 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 781113
11 August 1999 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 779226
3 August 1999 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1429193
3 May 1999 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1127100
19 April 1999 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1438822
26 March 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 229057
11 March 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 95811
11 February 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 222303
22 January 1999 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1381484
11 December 1998 Deadweight Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 813124
1 December 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 220329
30 November 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 230567
20 November 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 222174
20 November 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 231907
21 October 1998 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1468482
6 August 1998 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1453505
19 June 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 219314
17 June 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 219293
15 June 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 230154
18 May 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 218817
22 April 1998 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1467049
15 April 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 227861
23 March 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 231460
21 February 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 187865
22 January 1998 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1434665
14 January 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 169969
8 January 1998 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 776072
15 December 1997 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1115560
13 November 1997 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 164019
30 October 1997 Deficiency Check · Deadweight Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1454492
24 October 1997 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1396818
12 September 1997 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1114324
11 September 1997 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 158186
31 August 1997 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 53852
21 August 1997 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 784686
30 July 1997 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1404425
24 July 1997 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1380943
20 June 1997 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 35768
17 June 1997 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 35049
21 May 1997 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 774311
24 April 1997 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1442553
22 March 1997 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 115468
20 March 1997 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 18016
13 March 1997 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1106582
23 January 1997 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1100377
29 December 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 140932
19 December 1996 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1097805
25 October 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 108234
25 October 1996 COI Inspection · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1159591
15 October 1996 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 843829
8 October 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 128834
7 September 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 669
20 August 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 143476
8 August 1996 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1084488
3 August 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 150335
19 July 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 71064
13 July 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 44235
7 July 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 149013
22 June 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 165396
13 May 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1084624
9 May 1996 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1083737
8 May 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 173650
25 April 1996 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1081906
13 April 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 46001
7 March 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 117748
29 February 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 115414
9 February 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 111367
7 February 1996 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1185337
30 January 1996 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 883078
28 January 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 70219
16 January 1996 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 874428
13 January 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 64084
26 December 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 21123
14 December 1995 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 881707
11 December 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 174888
7 December 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 95653
28 November 1995 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1185939
1 November 1995 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1193446

Deficiency record · 213

11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 30 January 2026 No resolution recorded
46CFR § 199.45 Tests and inspections of lifesaving equipment and arrangements.(a) Initial inspection. The initial inspection of lifesaving appliances and arrangements for certification includes a demonstration of—(6) The proper condition and operation of embarkation appliances, including embarkation ladders and marine evacuation systems; Make proper repairs to the STBD side embarkation gate damaged by earlier event and make proper repairs to the PORT side embarkation gate which is frozen by rust. Both gates are for the rescue boats.
Due 28 February 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 July 2025 Resolved
The vessel is not ready for a COI inspection, issues with Fire Doors, Deck coverings, water leaking in overheads and on electrical lighting, door closures broken, windows broken all the above items discussed with the crew and they were instructed to conduct a vessel survey and make the vessel ready for the Inspection. Call when the vessel is ready. To be completed within 30 days and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2025
Resolved 22 August 2025
Resolution: Subsequent Inspection for the COI a new 835 issued, this one cleared so not to duplicate the current 835 issued 22Aug25.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 July 2025 Resolved
§ 199.45 Tests and inspections of lifesaving equipment and arrangements. (b) Reinspections. Tests and inspections of the lifesaving equipment shall be carried out during each inspection for renewal of certification and periodic inspection, and shall include, as applicable, a demonstration of— (4) The proper servicing of each inflatable liferaft and inflatable lifejacket has been serviced as required under this chapter; The life rafts on board the vessel are over due for servicing and will be required to be serviced prior the the vessel getting underway and prior to carrying any passengers on board even dockside. This must be completed within 30 days of this 835 issue date by 10Aug25.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2025
Resolved 22 August 2025
Resolution: Life Rafts Serviced.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 17 June 2025 No resolution recorded
§ 72.01-15 Structural standards.(a) In general, compliance with the standards established by the American Bureau of Shipping, see subpart 70.35 of this subchapter, will be considered satisfactory evidence of the structural efficiency of the vessel. However, in special cases, a detailed analysis of the entire structure or some integral part may be made by the Coast Guard to determine the structural requirements. Make the temp. repairs to the main deck BLKHDS Around Vessel IAW 17Nov25 repair proposal.
Due 28 February 2026 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › General alarm
Issued 14 January 2025 Resolved
§ 113.25-9 Location of general emergency alarm signal. General emergency alarm signal must:(a) Be located in passenger and crew quarters areas where they can alert persons in spaces where those persons may be maintaining, repairing, or operating equipment, stowing or drawing stores or equipment, or transiting, such as public spaces, work spaces, machinery spaces, workshops, galleys, emergency firepump room, bow thruster rooms, storage areas for paint, rope, and other stores, underdeck passageways in cargo areas, steering gear rooms, windlass rooms, holds of roll-on/roll-off vessels, and, except those that are accessible only through bolted manhole covers, duct keels with valve operators; and (b) Be audible in the spaces identified in paragraph (a) of this section with all normally closed doors and accesses closed; and (c) Be installed in cabins without loudspeaker installation. Other audible devices, such as electronic alarm transducers, are permitted. Currently 15 alarm bells are not working or not working properly. Make repairs and re-schedule the quarterly inspection within 2 weeks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2025
Resolved 16 January 2025
Resolution: Inspected and tested entire general alarm system. Operator replaced two 12v batteries new and replacement the battery charging system for the general alarm batteries. All found in satisfactory condition.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 July 2023 No resolution recorded
§ 78.37-5 Actions required to be logged. The actions and observations noted in this section shall be entered in the official log book. This section contains no requirements which are not made in other portions of this subchapter, the items being merely grouped together for convenience. (a) Onboard training, musters, and drills: held in accordance with subchapter W (Lifesaving Appliances and Arrangements) of this chapter. VESSEL IS RESTRICTED IN OPERATIONS THAT REQUIRE THE VESSEL TO GET UNDERWAY UNTIL ALL REQUIRED FIRE/SAFETY/ABANDON SHIP/SECURITY DRILL HAVE BEEN WITNESSED BY THE USCG. CONTACT SECTOR NEW ORLEANS DISPATCHER OFFICE WHEN THE DEFICIENCY IS TO BE CLEARED.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 March 2023 Resolved
46 CFR 111.10-3 Power Supply. In addition to the emergency power sources required under part 112 of this chapter, each self-propelled vessel and each mobile offshore drilling unit must have at least two electric generating sources. Currently the SSDG's on board are not operating properly and cannot be paralleled either automatically or manually. Make repairs to the operation of these three SSDG's so the parallel operation is working properly. Prior to the vessel getting underway with passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2023
Resolved 11 April 2023
Resolution: Shore tie bus breaker failed and was replaced in kind.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 March 2023 Resolved
46CFR 113.40-5 General requirements. The position of the rudder, if power-operated, must be shown at the principal steering station. If there is non-follow-up steering control at the alternative steering station, there must be a separate rudder angle indicator system for that station that is electrically independent from each other rudder angle indicator system. Currently the rudder angle indicators are not operating properly, make repairs to the indicators prior to getting the vessel underway with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2023
Resolved 11 April 2023
Resolution: EMI attended the vessel to re-calibrate. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 March 2023 Resolved
46 CFR111-30-25(e) (3) (f) For each shore power connection each switchboard must have: (1) A circuit breaker or fused switch; (2) A pilot light connected to the shore side of the circuit breaker or fused switch; and (3) One of the voltmeters under paragraph (b)(5) of this section connected to show the voltage of each phase of the shore power connection. Currently two of the shore tie breakers and connections are not working properly, make corrections/repairs within the next 30Days.
Action required: 705 - Other - as specified
Due 9 April 2023
Resolved 11 April 2023
Resolution: Shore tie was damaged when caught between the ship and the pier. Cut/spliced connection. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 March 2023 Resolved
46CFR199.630(a) in addition to the alternatives for certain requirements in § 199.620, passenger vessels operating in oceans; coastwise; Great Lakes; lakes, bays, and sounds; and rivers service may comply with alternative requirements to subparts A through C of this part as described in this section for the services specified in table 199.630(a) of this section. Currently there are no liferafts on board the vessel. Prior to getting underway install the required life rafts.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2023
Resolved 11 April 2023
Resolution: Liferafts received annual servicing and were properly installed onboard.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 March 2023 Resolved
46 CFR 72.05.50 Where automatic fire dampers are required, they shall be designed to operate at approximately 165 degrees F. for normal locations, and approximately 212 degrees F. for locations such as galleys. The dampers shall be so designed as to close against the anticipated draft in the duct. The damper shall be made accessible for periodic inspection by means of a hinged or bolted plate in the duct. The damper and the portion of duct containing the damper shall be constructed of at least 1/8 inch steel plate suitably stiffened. No insulation need be applied to the damper blade. Currently the damper on the 3rd deck is not operating properly and not allowing the complete zone to show Green on the control panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2023
Resolved 11 April 2023
Resolution: Replaced failed MC panel board.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 14 September 2022 Resolved
All lifesaving appliances and arrangements on passenger vessels must be in accordance with subchapter W (Lifesaving Appliances and Arrangements) of this chapter. Vessel did not have documentation that the weekly and monthly inspections required by 46 CFR 199.190(d) and (e) were completed. 46 CFR 70.28-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 6 October 2022
Resolution: Received evidence of new log and record keeping program onboard (with initial entries) to track lifesaving equipment inspection and maintenance.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 June 2022 Resolved
Currently the side shell fire door midship on the 2nd deck PORT side has been damaged and is not able to be closed or operated properly. Prior to operating the vessel with passengers, make proper repairs to the damaged fire door so it is closed and maintains the fire boundary. Since this door is only used while moored at the Hilton Docking facility and not used under way as an egress route the door may be made tight in a non operational way until a new door can be installed. Contact Tom Alho at [phone withheld] for proposed correction to this problem and it must be corrected prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2022
Resolved 16 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2021 Resolved
Currently the STBD main engine thruster control transducer is bad and will not allow pilot house control for this engine. The current module is obsolete and will have to be manufactured or a modification to the system installed. To be determined by cost of each. Prior to getting the vessel underway.
Due 13 November 2021
Resolved 15 November 2021
Resolution: Parts replaced and tested satisfactory to all satisfaction.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 13 October 2021 Resolved
. Currently the EDG switchboard breaker for the emergency fire pump trips immediately after the pump is energized when on the emergency source of power. Correct this issue and provide demonstration to the USCG. Prior to getting vessel underway.
Due 13 November 2021
Resolved 15 October 2021
Resolution: Main Breaker Amperage trip was adjusted to the needs of the system.
Communications › Alarms/Indicators › General Alarm
Issued 10 July 2012 Resolved
Prove proper operation of General Alarm bells. Ensure two bells on 3rd level near stairwell are operating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 17 August 2012
Resolution: Item cleared.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 10 July 2012 Resolved
Prove proper operation of NR2 SSG after repairs affected to turbocharger.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2012
Resolution: Item cleared.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 10 July 2012 Resolved
Submit Notice of Intent for Vessel General Permit to EPA. Provide proof to USCG inspector.
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 23 July 2012
Resolution: VGP applied for by master.
Communications › Alarms/Indicators › Refrigerated Spaces Alarm System
Issued 10 July 2012 Resolved
Prove proper operation of refrigerant leak detector system and alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 12 December 2012
Resolution: COI surrendered 12/12/12, added deficiency as special note.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 10 July 2012 Resolved
Provide USCG inspector proof of proper dayshapes required are onboard.
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 17 August 2012
Resolution: Item cleared.
Lifesaving › Hand Flares › Not on Board
Issued 10 July 2012 Resolved
Provide proof to USCG inspector that requirement is met for visual distress signals (flares). IAW 46CFR199.60(c) Each vessel must carry not less than 12 rocket parachute flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 17 August 2012
Resolution: Item cleared.
Engineering › Lubricating Oil Service System › Gauge
Issued 12 January 2012 Resolved
Replace INOP L/O pressure gauge on starboard MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2012
Resolved 15 March 2012
Resolution: L/O gauge replaced and tested.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 12 January 2012 Resolved
Repair/replace inoperable gauge in the strbd main diesel engine jacket water system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2012
Resolved 15 March 2012
Resolution: Temperature gauge replaced and tested.
Engineering › Thrusters › Piping
Issued 12 January 2012 Resolved
Repair/replace inoperable hydraulic pressure gauge in bow thruster piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2012
Resolved 15 March 2012
Resolution: Pressure gauge replaced and tested.
Engineering › Lubricating Oil Service System › Gauge
Issued 12 January 2012 Resolved
Repair/replace inoperable clutch pressure gauge on the port main diesel engine clutch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2012
Resolved 15 March 2012
Resolution: Clutch pressure gauge replaced and tested.
Lifesaving › Inflatable Liferafts › Servicing
Issued 21 July 2011 Resolved
Have liferafts serviced prior to expiration date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2011
Resolved 24 August 2011
Resolution: Received a certificate of liferafts being serviced prior to their expiration date.complete all SAT JWF
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 July 2011 Resolved
Have portable fire extinguishers serviced by the end of July 2011.
Action required: 705 - Other - as specified
Due 31 July 2011
Resolved 24 August 2011
Resolution: Portable fire extinguishers were serviced, complete all SAT JWF
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2011 Resolved
Secure loose wires and remove water on deck in the bar area on third deck starboard forward.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2011
Resolved 24 August 2011
Resolution: Secured loose wires and removed water on deck in the bar area on third deck starboard forward. complete all SAT JWF
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 July 2011 Resolved
Replace missing blank inside electrical panel 407 located on third deck port side, aft of cage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2011
Resolved 24 August 2011
Resolution: Replaced missing blank inside electrical panel 407 located on third deck port side, aft of cage. all SAT JWF
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 21 July 2011 Resolved
Tighten fire safety door (FSD) magnets on FSD located on second deck port forward.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2011
Resolved 24 August 2011
Resolution: Fire safety door (FSD) magnets on FSD located on second deck port forward, were fixed and are operational. JWF
Lifesaving › Lifebuoys › Serviceable
Issued 21 July 2011 Resolved
Place retro-reflective tape on back side of life ring located on third deck starboard forward.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2011
Resolved 24 August 2011
Resolution: Place retro-reflective tape on back side of life ring located on third deck starboard forward, completed all SAT. JWF
Communications › Alarms/Indicators › General Alarm
Issued 21 July 2011 Resolved
Service general alarm bells on third deck port and starboard sides so they are audible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2011
Resolved 24 August 2011
Resolution: Serviced general alarm bells on third deck port and starboard sides, complete all SAT JWF
Fire Fighting › Nozzles › Condition
Issued 21 July 2011 Resolved
Replace three defective 1.5 inch nozzles discovered during fire hose hydro test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2011
Resolved 24 August 2011
Resolution: Repaired two of the three 1.5 inch nozzles and replaced in kind with the third one, all SAT JWF
Engineering › Steering Gear System › Feedback Unit
Issued 4 January 2011 Resolved
Prove proper operation of Starboard Bridge Wing auxiliary steering station. Parts on order.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2011
Resolved 16 May 2011
Fire Fighting › Fire Hoses › Condition
Issued 4 January 2011 Resolved
Replace the section of fire hose that failed during pressure test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2011
Resolved 4 January 2011
Resolution: Replaced on scene during inspection.
Communications › Alarms/Indicators › General Alarm
Issued 4 January 2011 Resolved
Place General alarm placards in proper locations where visible.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 February 2011
Resolved 16 May 2011
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 4 January 2011 Resolved
Properly install wire thru deck penetration for Emergency Generator door alarm.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 February 2011
Resolved 17 May 2011
Electrical › Electric Supply System (service) › Cable
Issued 4 January 2011 Resolved
Properly install wires in surveillance UPS.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 February 2011
Resolved 17 May 2011
Electrical › Electric Supply System (service) › Cable
Issued 4 January 2011 Resolved
Properly dead end wires in shaft alley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 February 2011
Resolved 4 January 2011
Resolution: Wires were dead ended prior to completion of inspection.
Fire Fighting › Automatic Sprinkler System › Piping
Issued 6 October 2010 Resolved
Repair/ replace leaking crossover pipe on # 2 sprinkler pressure vessel.
Action required: 705 - Other - as specified
Due 6 January 2011
Resolved 10 November 2010
Resolution: Repairs made and tested to the satisfaction of the Chief Engineer.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 6 October 2010 Resolved
Prove proper operation of starboard bridge wing rudder angle indicator.
Action required: 705 - Other - as specified
Due 6 January 2011
Resolved 4 January 2011
Resolution: Repaired starboard bridge wing rudder angle indicator.
Construction/Loadline › Hull › Bottom Plating
Issued 6 October 2010 Resolved
Remove scale in #4 ballast tank starboard side bilge knuckle at the forward bulkhead and treat
Action required: 705 - Other - as specified
Due 5 April 2011
Resolved 21 July 2011
Resolution: Item cleared during quarterly inspection.
Construction/Loadline › Hull › Bottom Plating
Issued 6 October 2010 Resolved
Remove scale from #5 ballast tank bottom plate and treat.
Action required: 705 - Other - as specified
Due 7 October 2011
Resolved 24 August 2011
Resolution: Removed scale from #5 ballast tank bottom plate and treated, complete all SAT JWF
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 October 2010 Resolved
Place consortium Letter of Regulatory Compliance in DAPI binder.
Action required: 705 - Other - as specified
Due 7 January 2011
Resolved 4 January 2011
Resolution: Headquarters stated that there is a backlog on these letters.
Fire Fighting › Automatic Sprinkler System › Pressure Tank
Issued 6 October 2010 Resolved
Repair/ replace bottom pipe fitting on #2 sprinkler pressure vessel gage column.
Action required: 705 - Other - as specified
Due 8 October 2010
Resolved 7 October 2010
Fire Fighting › Automatic Sprinkler System › Pressure Gauges
Issued 6 October 2010 Resolved
Repair/ replace bottom pipe fitting on #1 sprinkler pressure vessel gage column.
Action required: 705 - Other - as specified
Due 8 October 2010
Resolved 7 October 2010
Communications › Alarms/Indicators › General Alarm
Issued 11 January 2010 Resolved
Repair/ Replace and prove proper operation of general alarm bells five (5) on first deck, three (3) on second deck and four (4) on third deck.
Action required: 705 - Other - as specified
Due 8 October 2010
Resolved 7 October 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 11 January 2010 Resolved
Repair fuel oil leak on port main engine fuel pump.
Action required: 705 - Other - as specified
Due 11 February 2010
Resolved 22 April 2010
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 11 January 2010 Resolved
Repair oil leak on number one generator governor.
Action required: 705 - Other - as specified
Due 11 February 2010
Resolved 22 April 2010
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 January 2010 Resolved
Recharge and service Emergency Breathing Apparatus in ECC.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2010
Resolved 22 April 2010
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 January 2010 Resolved
Recharge Emergency Breathing Apparatus in chiller room and replace breakaway glass.
Action required: 705 - Other - as specified
Due 11 February 2010
Resolved 22 April 2010
Communications › Visual Communication › Signalling Lamp
Issued 11 January 2010 Resolved
Properly label all emergency signaling lights in all engineering spaces.
Action required: 705 - Other - as specified
Due 11 February 2010
Resolved 14 July 2010
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 January 2010 Resolved
Plug knockout holes in number one generator 24 volt control box.
Action required: 705 - Other - as specified
Due 11 February 2010
Resolved 22 April 2010
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 8 April 2009 Resolved
Prove proper operation of depth sounding device.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 20 April 2009
Navigation › Piloting/Steering › Swing Meter
Issued 8 April 2009 Resolved
Prove proper operation of port bridge wing flanking rudder angle indicator.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 7 May 2009
Navigation › Piloting/Steering › Swing Meter
Issued 8 April 2009 Resolved
Prove proper operation of stbd bridge wing stbd flanking rudder angle indicator.
Action required: 705 - Other - as specified
Due 20 November 2009
Resolved 30 October 2009
Resolution: Manufacturer''s representative attended vessel, made repairs and tested all indicators, all indicators operating satisfactory.
Navigation › Piloting/Steering › Swing Meter
Issued 8 April 2009 Resolved
Prove proper operation of stbd bridge wing main rudder angle indicator.
Action required: 705 - Other - as specified
Due 20 November 2009
Resolved 30 October 2009
Resolution: Manufacturer''s representative attended vessel, made repairs and tested all indicators, all indicators operating satisfactory.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 8 April 2009 Resolved
Replace retroreflective material on five (5) lifejackets in 3rd deck bow, one (1) in main deck bow, one (1) in stern deck life jacket lockers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 7 May 2009
Lifesaving › Emergency Outfit › Fire ax
Issued 8 April 2009 Resolved
Properly mark starboard bow and main deck stern fire axes with vessel name.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 20 April 2009
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 8 April 2009 Resolved
Properly mark No. 5 extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 20 April 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 8 April 2009 Resolved
Properly mark No. 11 extingusher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 20 April 2009
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 8 April 2009 Resolved
Install non-conducting deck covering behind emergency generator switchboard.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 20 April 2009
Engineering › Fuel Oil Service System › Filter
Issued 8 April 2009 Resolved
Repair fuel oil leak on emergency generator fuel oil filter.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 20 April 2009
Engineering › Lubricating Oil Service System › Piping
Issued 8 April 2009 Resolved
Repair lube oil leak on emergency generator lube oil drainage piping.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 20 April 2009
Engineering › Fuel Oil Service System › Hose
Issued 8 April 2009 Resolved
Repair fuel oil leak on bow thruster engine.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 20 April 2009
Electrical › Electrical Distribution System (emergency) › Cable
Issued 8 April 2009 Resolved
Make proper cut-out for bow thruster battery cables to ensure cover fits properly.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 20 April 2009
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 April 2008 Resolved
Make permanent repair to radar monitor to work as designed.
Due 17 May 2008
Resolved 15 July 2008
Resolution: Made repairs to monitor.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 April 2008 Resolved
Update fire control plan.
Due 17 May 2008
Resolved 15 July 2008
Resolution: Updated plan.
Engineering › Steering Gear System › Follow-up Assembly
Issued 17 January 2006 Resolved
Port steering rudder winging erratically, not following rudder commands.
Condition: Unknown
Due 17 February 2006
Resolved 18 January 2006
Resolution: Replaced steering follow-up switch and conducted steering test, test found to be satisfactory. System placed back into normal operation.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 January 2005 Resolved
Identify and label all emergency lighting breakers and fixtures.
Due 19 February 2005
Resolved 2 March 2005
Resolution: All lighting marked and breakers identified.
Construction/Loadline › Structures › Door
Issued 15 July 2004 Resolved
Provide a means to keep the CO2 room door closed and locked.
Action required: 705 - Other - as specified
Due 15 August 2004
Resolved 25 August 2004
Resolution: Installed lock on door.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 July 2004 Resolved
Submit corrected/updated Fire Control Plan to Marine Safety Center for review.
Action required: 705 - Other - as specified
Due 15 August 2004
Resolved 25 August 2004
Resolution: Vessel updated Five Control Plan.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 January 2004 Resolved
Extinguisher's pressure gage found below normal reading.
Due 15 January 2004
Resolved 15 January 2004
Resolution: Replaced extinguisher prior to end of inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 January 2004 Resolved
Floating water light found full of water.
Condition: Unknown
Due 15 January 2004
Resolved 15 January 2004
Resolution: Replaced withe new light.
Communications › Alarms/Indicators › General Alarm
Issued 15 January 2004 Resolved
General alarm bell on fouth deck stbd side aft inoperable.
Condition: Unknown
Due 15 January 2004
Resolved 15 January 2004
Resolution: General alarm bell replace prior to end of inspection.
Fire Fighting › Ventilation Systems
Issued 14 October 2003 Resolved
Clean dampener blades for both engine room stack closures.
Condition: Improper/Lack of Maintenance
Due 15 November 2003
Resolved 27 October 2003
Resolution: Observed clean dampeners.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 14 October 2003 Resolved
Clean dust from all sprinkler heads located in stair towers.
Condition: Improper/Lack of Maintenance
Due 15 November 2003
Resolved 27 October 2003
Resolution: Observed clean sprinkler heads.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 14 October 2003 Resolved
Adjust stair tower door 1st deck port side.
Condition: Improper/Lack of Maintenance
Due 15 November 2003
Resolved 27 October 2003
Resolution: Observed SAT door closure operation.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 14 October 2003 Resolved
Adjust exterior door closures 3rd deck aft port side and 2nd deck aft port side.
Condition: Improper/Lack of Maintenance
Due 15 November 2003
Resolved 27 October 2003
Resolution: Observed SAT operation of door closures.
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 January 2003 Resolved
Remove outdated supplies from ALL first aid boxes and eyewash stations and REPLACE with new supplies. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 8 February 2003
Resolved 14 February 2003
Resolution: Spot check of medical first aid kits/eye wash stations revealed new/current supplies.
Engineering › Steering Gear System
Issued 8 January 2003 Resolved
Switch flanking rudder controls & gauges to reflect true relationship when manning station in steering space. LEGACY COMPONENT DESC: Rudder Angle Indicator
Condition: Design Flaw
Due 8 February 2003
Resolved 14 February 2003
Resolution: Observed controls/gauges in true relationship when manning station.
Electrical › Electrical Distribution System (service)
Issued 8 January 2003 Resolved
Investigate and correct cause for amperage to ground indicated on gaming power distribution panel in engine room. LEGACY COMPONENT DESC: Ground Detection
Condition: Improper/Lack of Maintenance
Due 8 February 2003
Resolved 14 February 2003
Resolution: Observed zero amperage to ground on gaming distribution panel in engine room.
Lifesaving › Lifebuoys
Issued 8 January 2003 Resolved
Repair/replace P&S 4th deck ring buoy lights with approved buoy lights. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Unknown
Due 8 February 2003
Resolved 14 February 2003
Resolution: Observed new ring buoy lights in place.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 8 January 2003 Resolved
Identify and label throughout vessel fire extinguisher station numbers. LEGACY COMPONENT DESC: Number
Condition: Improper/Lack of Maintenance
Due 8 February 2003
Resolved 14 February 2003
Resolution: Spot check of fire stations revealed proper numbering.
Fire Fighting › Structural Fire Protection - General
Issued 8 January 2003 Resolved
Prove/provide evidence of fire chalk is Coast Guard approved.
Due 8 February 2003
Resolved 14 February 2003
Resolution: Observed evidence of approved fire chalk.
Fire Fighting › Means of Escape
Issued 8 January 2003 Resolved
Relocate slot machines located in egress route 2nd deck to ensure proper spacing between chairs. LEGACY COMPONENT DESC: Corridors
Due 8 February 2003
Resolved 14 February 2003
Resolution: Observed area free from slot machine congestion.
Electrical › Electrical Distribution System (service)
Issued 16 October 2002 Resolved
Inspect and repair all "A" & "B" class bulkhead penetrations and apply approved fire caulk as needed. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 28 October 2002
Resolution: Walked around vessel, observed wire runs/cableways with new/appropriate fire caulk in place at bulkhead penetrations.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 October 2002 Resolved
Repair/renew/replace guards for fan motor/drive belts located in Texas Deck Stack area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 28 October 2002
Resolution: Observed newly fabricated guards in place on both exhaust fan drive motors.
Communications › Audible Communications › SPD (Other)
Issued 16 October 2002 Resolved
All decks, all levels monitor and adjust as appropriate PA Sound levels to ensure sound can be heard above background noise.
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 28 October 2002
Resolution: Observed new amplifier in place while old one is getting repaired. Walked throughout vessel while PA system was in operation. Sound levels appear to be satisfactory.
Electrical › Electrical Distribution System (service)
Issued 9 July 2002 Resolved
REPLACE INSTALLED SURGE SUPPRESSOR(S) WIRE PERMENANT HARDWIRING IAW IEEE ON ALL GAMING TABLES. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 August 2002
Resolved 9 July 2002
Resolution: INSTALLED SURGE SUPPRESSOR(S) WIRE PERMANENT HARDWIRING REPLACED.
Fire Fighting › Structural - A Class Divisions
Issued 9 July 2002 Resolved
REPAIR/REPLACE TWO FORWARD PORTSIDE FIRE DOOR FRAMES IAW 46 CFR 72.05, SFP REQUIREMENTS DUE TO HOLEING DUE TO RUST. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 August 2002
Resolved 9 July 2002
Resolution: TWO FORWARD PORTSIDE FIRE DOOR FRAMES REPAIRED.
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 9 July 2002 Resolved
LABEL WITH PLAQUE FIRE CONTROL PLANS STARBOARD SIDE.
Condition: Unknown
Due 8 August 2002
Resolved 9 July 2002
Electrical › Electrical Distribution System (service)
Issued 9 July 2002 Resolved
REPLACE INSTALLED SURGE SUPPRESSOR(S), WIRE PERMNANT HARDWIRING IAW IEEE ON ALL GAMING TABLES. ITEM ERRONEOUSLY RESOLVED ON 07/09/2002 LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 August 2002
Resolved 15 August 2002
Resolution: Observed sat removal of surge supressors and hard wiring of related outlets.
Fire Fighting › Structural - A Class Divisions
Issued 9 July 2002 Resolved
REPAIR/REPLACE TWO FOWARD PORTSIDE FIRE DOOR FRAMES IAW 46 CFR 72.05, SFP REQUIREMENTS DUE TO HOLEING DUE TO RUST. ITEM RESOLVED ERRONEOUSLY ON 07/09/2002 LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 August 2002
Resolved 15 August 2002
Resolution: Observed sat repairs/replacement of above fire door frames.
Electrical
Issued 18 October 2001 Resolved
CONDUCT LOAD ANALYSIS VERIFICATION OF SURGE STRIPS BEING UTILIZED IN 3RD DECK REWARDS SECTION. SUBMIT PROPOSAL FOR INSTALLATION OF PERMAMENT RECEPTACLES AND CIRCUITS AS NECESSARY.
Condition: Unknown
Due 17 November 2001
Resolved 11 December 2001
Engineering
Issued 18 October 2001 Resolved
PROVIDE COPY OF PERIODIC SAFETY TEST PROCEDURES FOR ENGINE ROOM AUTOMATION.
Condition: Unknown
Due 8 August 2002
Resolved 9 July 2002
Resolution: COPY OF PERIODIC SAFETY TEST PROCEDURES PROVIDED.
Electrical
Issued 18 October 2001 Resolved
DEMONSTRATE PROPER OPERATION OF REVERSE POWER RELAYS.
Condition: Unknown
Due 17 November 2001
Resolved 11 December 2001
Navigation
Issued 18 October 2001 Resolved
DEMONSTRATE PROPER OPERATION OF STEERING FROM ALL MODES AND LOCATIONS UPON COMPLETION OF REPAIRS TO SWITCHBOARD LOGIC CARD.
Condition: Unknown
Due 17 November 2001
Resolved 11 December 2001
Engineering
Issued 18 October 2001 Resolved
PROVIDE COPY OF PERIODIC SAFETY TEST PROCEDURES FOR ENGINE ROOM AUTOMATION. ITEM ERRONEOUSLY RESOLVED ON 07/09/2002
Condition: Unknown
Due 8 August 2002
Resolved 15 August 2002
Resolution: Observed copy of periodic safety test procedures. Engineering crew is in the process of refining procedures and implementing test schedules.
Fire Fighting
Issued 26 July 2001 Resolved
INSPECT AND REPLACE OR REPAIR ALL FIRE DOORS EXCEEDING PERIMETER GAP REQUIRMENTS PER 46 CFR 72.05-25(b).
Condition: Unknown
Due 25 August 2001
Resolved 18 September 2001
Engineering
Issued 26 July 2001 Resolved
MAKE PERMENANT REPAIRS TO ENGINE ROOM EXHAUST VENTILATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 August 2001
Resolved 18 September 2001
Accommodation/Occupational Safety
Issued 26 July 2001 Resolved
CLEAN DECK AND EFFECT SOLUTION TO LONG TERM HOUSEKEEPING PROBLEMS IN BAR/SERVICE AREAS.
Condition: Unknown
Due 25 August 2001
Resolved 18 September 2001
Construction/Loadline
Issued 31 January 2001 Resolved
BOLT THE SOUNDING TUBE TO ITS RESPECTIVE BRACKET IN THE #5 VOID.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Construction/Loadline
Issued 31 January 2001 Resolved
INSTALL PACKING TO THE FORWARD PORT BILGE ALARM BULKHEAD FITTING IN THE #4 VOID AND REMOVE THE LOOSE BILGE ALARM WIRE BUNDLE IN THE #6 VOID.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Construction/Loadline
Issued 31 January 2001 Resolved
PROVIDE BILGE SUCTION STRAINERS TO THE FOLLOWING TANKS: FOREPEAK, #5,6&7 VOIDS, AND #2&9 BALLAST TANKS.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Construction/Loadline
Issued 31 January 2001 Resolved
PROVE THE PROPER OPERATION OF THE FOREPEAK BILGE SUCTION VALVE REACH ROD.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Engineering
Issued 31 January 2001 Resolved
ADJUST THE PACKING GLANDS OF THE KEEL COOLER CUTOFF VALVES IN #4 VOID AS NEEDED TO STOP THEIR LEAKAGE.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Engineering
Issued 23 January 2001 Resolved
DEMONSTRATE PROPER OPERATION OF BOW THRUSTER AND ASSOCIATED SAFETIES AFTER ENGINE BREAK IN PERIOD.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Electrical
Issued 23 January 2001 Resolved
DEMONSTRATE PROPER OPERATION OF SSDG'S AND ASSOCIATED ALARMS/SHUTDOWNS AFTER ADEQUATE ENGINE BREAK-IN PERIOD.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Engineering
Issued 23 January 2001 Resolved
DEMONSTRATE PROPER OPERATION OF MPDE ALARMS AND SHUTDOWNS.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Electrical
Issued 19 October 2000 Resolved
VERIFY GAMING TABLE THROUGH DECK PENETRATIONS TO ENSURE MEET APPLICABLE FIRE AND WATER TIGHT REQUIREMENTS.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Accommodation/Occupational Safety
Issued 19 October 2000 Resolved
CONDUCT GENERAL HOUSE KEEPING REMOVING FIRE HAZARDS AND ENSURING ADEQUATE ELECTRICAL SERVICES.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Electrical
Issued 19 October 2000 Resolved
DEMONSTRATE PROPER OPERATION OF UPS BATTERY BACK-UP FOR EOS, MACHINERY MONITORING AND ALARM SYSTEM.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Accommodation/Occupational Safety
Issued 20 July 2000 Resolved
DISCONTINUE OPERATION OF WINNER'S LOUNGE 3RD DECK FOOD SERVICE BAR UNTIL THE SANITARY CONDITION IS FOUND ACCEPTABLE TO THE VESSEL CAPTAIN.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Fire Fighting
Issued 20 July 2000 Resolved
ADJUST/RENEW DOOR HARDWARE TO THE EMERGENCY EXIT DOORS LOCATED MIDSHIP ON THE PORT SIDE OF THE MAIN DECK, BOILER DECK AND HURRICANE DECK.
Condition: Unknown
Due 20 July 2000
Resolved 20 July 2000
Deck/Cargo
Issued 19 April 2000 Resolved
CONDUCT DYE-PENETRANT TESTS VICINITY OF THE DECK PADS TO DECK WELDS OF THE STANDING RIGGING OF THE PORT AND STARBOARD STACKS OF THE TOP DECK.
Condition: Unknown
Due 19 May 2000
Resolved 28 April 2000
Electrical
Issued 19 April 2000 Resolved
MAKE REPAIRS TO THE EXPOSED WIRING AT THE SEARCHLIGHT IN THE VICINITY OF THE PORT AFT RESCUE BOAT.
Condition: Unknown
Due 19 May 2000
Resolved 28 April 2000
Accommodation/Occupational Safety
Issued 27 January 2000 Resolved
REMOVE EXCESS WATER ON DECK OF ICE MACHINE SPACE AND MAINTAIN DECK IN A DRYCONDITION._x001C_
Condition: Unknown
Due 27 January 2000
Resolved 4 February 2000
Engineering
Issued 27 January 2000 Resolved
ADJUST PACKINGS TO PORT/STBD PROPULSION SHAFTS.
Condition: Unknown
Due 27 January 2000
Resolved 4 February 2000
Accommodation/Occupational Safety
Issued 27 January 2000 Resolved
ADJUST LATCHING MECHANISM TO THE 4TH DECK PORT SIDE FORWARDMOST FIRE DOOR.
Condition: Unknown
Due 27 January 2000
Resolved 4 February 2000
Accommodation/Occupational Safety
Issued 27 January 2000 Resolved
REMOVE CARDBOARD BOXES FROM DECK IN LIQUOR LOCKER AND PROPERLY STOW LIQUOR ON RACKS PROVIDED IN LOCKER.
Condition: Unknown
Due 27 January 2000
Resolved 4 February 2000
Accommodation/Occupational Safety
Issued 19 October 1999 Resolved
PROVIDE A LABEL IDENTIFYING THE COMPARTMENT SERVED BY THE VENT PIPE ADJACENT TO THE ENGINEROOM MAIN DECK OUTSIDE DOOR STBD SIDE.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Electrical
Issued 19 October 1999 Resolved
FABRICATE A GUARD TO PROTECT WIRES AT DECK LEVEL IN THE FIRST AID COMPARTMENT.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Engineering
Issued 19 October 1999 Resolved
MAKE REPAIRS AS NEEDED TO THE BOW THRUSTER OVERBOARD DISCHARGE PIPING IN LIEU OF THE SOFT PATCH AS PRESENTLY INSTALLED.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Accommodation/Occupational Safety
Issued 19 October 1999 Resolved
REPLACE THE SCREEN TO THE INTAKE VENT LOCATED MIDSHIP AT THE STBD MAIN DECKLEVEL.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Accommodation/Occupational Safety
Issued 19 October 1999 Resolved
MAKE REPAIRS TO THE HEAD AND FOOT KEEPERS TO THE SERVICE RAMP DOORS AT THE PORT MAIN DECK.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Electrical
Issued 19 October 1999 Resolved
PROVIDE STRESS RELIEF (WIRE BRAID) TO THE MAIN DECK STBD BOW FLOODLIGHT.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Electrical
Issued 19 October 1999 Resolved
REPLACE AND PROVIDE PROOF OF TESTING OF THE #1 GENERATOR JACKET WATER HIGH TEMP ALRM/SENDING UNIT.
Condition: Unknown
Due 20 November 1999
Resolved 1 November 1999
Electrical
Issued 19 October 1999 Resolved
REVIEW ALL PANEL CIRCUIT BREAKER LABELS FOR AGREEANCE WITH BREAKER PANEL IDENTIFICATION CARDS.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Lifesaving
Issued 19 October 1999 Resolved
REPLACE THE RETRO-REFLECTIVE TAPE ON THE LIFEJACKETS AS NEEDED.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Electrical
Issued 19 October 1999 Resolved
RECAULK ELECTRICAL STUFFING TUBES AS NEEDED ON PILOTHOUSE ROOF.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Accommodation/Occupational Safety
Issued 30 August 1999 Resolved
ADJUST THE DECIBEL LEVEL OF THE AEVADS MESSAGING SYSTEM TO PROVIDE A DISCERNABLE LEVEL ABOVE CROWD NOISE. PROVIDE NEW MESSAGING SYSTEM READINGS TO USCG MARINE SAFETY OFFICE LOUISVILLE.
Condition: Unknown
Due 30 August 1999
Resolved 30 August 1999
Engineering
Issued 3 August 1999 Resolved
REVISE FLAME SCREENS OF THE OILY WATER TANK VENT AND THE BOW THRUSTER FUEL OIL TANK VENT TO PROVIDE A SEAL TO MATING SURFACE OF THE SCREEN BORDER.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Accommodation/Occupational Safety
Issued 3 August 1999 Resolved
PROVIDE DECIBEL READINGS OF AEVADS MESSAGING SYSTEM AND DECIBEL READINGS OFCROWD NOISE FOR COMPARISON.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Navigation
Issued 3 August 1999 Resolved
REPAIR OR REPLACE THE STBD RADAR UNIT.
Condition: Unknown
Due 5 August 1999
Resolved 5 August 1999
Fire Fighting
Issued 3 August 1999 Resolved
FABRICATE A GUARD FOR THE SPRINKLER HEAD IN THE HARD COUNT SPACE THAT WILL PROTECT IT FROM DAMAGE DURING BASKET HANDLING AND WILL NOT IMPEDE WATER FLOW/PATTERN.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Lifesaving
Issued 19 April 1999 Resolved
PROVIDE SNAP HOOKS ON LANYARDS FOR ATTACHMENT OF WATERLIGHTS ON RING BUOYS.
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Lifesaving
Issued 19 April 1999 Resolved
REMOVE PLASTIC TRASH CANS THROUGHOUT VESSEL AND REPLACE AS NEEDED WITH METAL TRASH CANS.
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Engineering
Issued 21 October 1998 Resolved
REPLACE RELIEF VALVE ON NO.1 STBD AFT AIR RECEIVER IN ENGINE ROOM.
Condition: Unknown
Due 28 December 1998
Resolved 28 December 1998
Lifesaving
Issued 21 October 1998 Resolved
STENCIL VESSEL NAME ON OARS OF RESCUE BOAT.
Condition: Unknown
Due 28 December 1998
Resolved 28 December 1998
Lifesaving
Issued 21 October 1998 Resolved
REPLACE FADED PLACARDS ON VESSEL EXTERIOR AS NEEDED.
Condition: Unknown
Due 28 December 1998
Resolved 28 December 1998
Electrical
Issued 21 October 1998 Resolved
POST A "DANGER HIGH VOLTAGE" PLACARD ON EMERGENCY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 28 December 1998
Resolved 28 December 1998
Lifesaving
Issued 21 October 1998 Resolved
PAINT A YELLOW RADIUS ON DECK AT STERN STOWAGE VICINITY OF OXY ACETYLENE BOTTLES AND DESIGNATE AS "NO SMOKING" AREA.
Condition: Unknown
Due 28 December 1998
Resolved 28 December 1998
Lifesaving
Issued 24 October 1997 Resolved
REPLACE 8 WATER-LOGGED PFD'S; TOTAL PERSONS ALLOWED REDUCED TO 2,992 PENDING REPLACEMENT.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Fire Fighting
Issued 24 October 1997 Resolved
PROVIDE TEST REPORT PRINT-OUT FOR ALL FIRE, HEAT AND SMOKE ALARMS/DETECTORS.
Condition: Unknown
Due 24 November 1997
Resolved 5 November 1997
Electrical
Issued 24 October 1997 Resolved
PROVIDE COVER PLATE FOR DETROIT PRESSURE SWITCH ON EMERGENCY DIESEL.
Condition: Unknown
Due 24 November 1997
Resolved 5 November 1997
Electrical
Issued 24 October 1997 Resolved
PERMANENTLY MOUNT CLIMATE CONTROL SENSOR HEAD ADJACENT TO ELECTRICAL PANEL IN THE ELEVATOR EQUIPMENT ROOM.
Condition: Unknown
Due 24 November 1997
Resolved 5 November 1997
Electrical
Issued 24 October 1997 Resolved
DO NOT OPERATE ENGINE ROOM SUPPLY FAN UNTIL PROPERLY WIRED TO SECURE UPON ACTIVATION OF THE FIXED CO2 SYSTEM.
Condition: Unknown
Due 24 November 1997
Resolved 5 November 1997
Electrical
Issued 24 October 1997 Resolved
LABLE DISTRIBUTION PANEL IN ELEVATOR EQUIPMENT ROOM.
Condition: Unknown
Due 24 November 1997
Resolved 5 November 1997
Deck/Cargo
Issued 12 September 1997 Resolved
Determine cause of bow-thruster failure; effect permanent repairs and proveproper operation to the satisfaction of an attending marine inspector.
Condition: Unknown
Due 12 September 1997
Resolved 12 September 1997
Electrical
Issued 24 July 1997 Resolved
PROPERLY ROUTE WIRING THROUGH PENETRATIONS (ONE WIRE PER PENETRATION) ON THE FORWARD BULKHEAD OF STARBOARD AUX MACHINERY SPACE.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Electrical
Issued 24 July 1997 Resolved
PROPERLY INSTALL AND SECURE/BAND ALL WIRING/CABLES IN WAY OF HURRICANE DECKMODIFICATIONS; TERMINATE ALL SPLICES IN JUNCTION BOXES & MINIMIZE THE USE OF PLASTIC CABLE TIES IN ACCORDANCE WITH IEEE 45.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Fire Fighting
Issued 24 April 1997 Resolved
FIRE CAULK VARIOUS SURVEILANCE WIRE STUFFING TUBES IN THE PORT ELECTRICAL PANEL ROOMS ON THE 2ND AND 3RD DECKS.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Fire Fighting
Issued 24 April 1997 Resolved
REMOVE COMBUSTIBLE INSULATION SURROUNDING THE ENGINE ROOM CONTROL SPACE.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 25 October 1996 Resolved
LABEL REMOTE EMERGENCY SHUTDOWN FOR FUEL OIL TRANSFER PUMP ON PORT SIDE MAIN DECK PER 46 CFR 111.103-9(b).
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Engineering
Issued 25 October 1996 Resolved
EFFECT PERMANENT REPAIRS TO THE PORT MAIN ENGINE FUEL OIL PUMP.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Navigation
Issued 25 October 1996 Resolved
PROVIDE AN EMERGENCY POWER SOURCE TO THE REPEATER FOR THE CREW PORTABLE RADIO NETWORK PER 46 CFR 112.15-5(a).
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Navigation
Issued 25 October 1996 Resolved
EFFECT REPAIRS TO THE ENGINE ROOM CONSOLE AUDIBLE ALARM FOR THE PORT FLANKING RUDDER LOW HYDRAULIC OIL ALARM.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Engineering
Issued 25 October 1996 Resolved
INSTALL SHAFT SPEED AND DIRECTION INDICATORS AT THE ENGINE ROOM CONTROL CONSOLE PER 46 CFR 113.37-5.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Engineering
Issued 25 October 1996 Resolved
PROVIDE RELIEF VALVE FOR THE NO. 1 AIR RECEIVER WHICH WILL RELIEVE AT A PRESSURE NOT EXCEEDING THE MAWP OF THE TANK.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Construction/Loadline
Issued 25 October 1996 Resolved
MAKE THE HVAC DRAIN PENETRATION IN THE PORT AFT ENGINE ROOM BULKHEAD WATERTIGHT (COMPLETE CONTINUOUS WELD ON BOTH SIDES).
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Lifesaving
Issued 8 August 1996 Resolved
REMOVE ALL STORED COMBUSTIBLES (PAINTS, OILS, PENETRANTS, ETC.) FROM THE VESSEL.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Fire Fighting
Issued 8 August 1996 Resolved
REMOVE THE COMBUSTIBLE RUBBER STEP GUARDS FROM THE STARBOARD AFT STAIR WELL.
Condition: Unknown
Due 8 August 1996
Resolved 8 August 1996
Electrical
Issued 14 December 1995 Resolved
INSTALL ACCEPTABLE WIRE SPLICES PER 46CFR111.60-19 INSIDE THE FIRE DETECTION/ALARM SYSTEM PANEL.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Lifesaving
Issued 14 December 1995 Resolved
PROVE CURRENT HYDRO TEST AND INSTALL SATISFACTORY HARNESSES ON THE ACETYLENE AND OXYGEN BOTTLES AT THE TOP OF THE ENGINE ROOM STAIRWAY.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Fire Fighting
Issued 14 December 1995 Resolved
CORRECT CLEARANCES BETWEEN DOUBLE FIRE SCREEN DOORS NOT TO EXCEED 1/8 INCH.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Lifesaving
Issued 14 December 1995 Resolved
INITIATE PERIODIC TESTS OF THE AEVADS SYSTEM AND MAINTAIN A LOG IN ACCORDANCE WITH NFPA 72, CHAPTER 10-2.4, AND ENCLOSURE (2) TO NVIC 8-93 PARAGRAPH 22(F).
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Electrical
Issued 14 December 1995 Resolved
COMPLETE WIRING INSTALLATION/RETENTION IN THE OVERHEAD OF THE FOLLOWING SPACES: COMPUTER ROOM, CCTV ROOM, SOFT COUNT ROOM, MAIN BANK ROOM, AND HURRICANE DECK IN WAY OF THE PORT SIDE/FORWARD STAIR TOWER DOORS.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Lifesaving
Issued 14 December 1995 Resolved
PERMANENTLY MOUNT CABINETS IN THE HARD AND SOFT COUNT ROOMS.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Fire Fighting
Issued 14 December 1995 Resolved
INITIATE PERIODIC TESTS ON THE SPRINKLER SYSTEM AND MAINTAIN A LOG IAW NFPA 25 AND ENCLOSURE (1) TO NVIC 10-93, CHAPTER 9.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Electrical
Issued 14 December 1995 Resolved
PERMANENTLY MOUNT WHITE SPEAKER BOXES IN THE OVERHEAD OF THE HOLD PASSAGE WAYS.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Fire Fighting
Issued 14 December 1995 Resolved
REMOVE, OR INCAPSULATE WITH APPROVED METAL SHEATHED INSULATION, ARMORFLEX ON THE BEVERAGE DESPINSING LINES IN THE SODA ROOM.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Accommodation/Occupational Safety
Issued 14 December 1995 Resolved
REPLACE THE SODA ROOM PRESSURE VESSEL WITH ONE PER 46CFR54.10(5)(C). LESS THAN 5 CUBIC FT. PROVIDE ACCEPTABLE RELIEF VALVE FOR SAME.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Electrical
Issued 14 December 1995 Resolved
INSTALL INCANDESCENT LIGHTS OR OTHER ACCEPTABLE ALTERNATIVE TO INCREASE LIGHTING IN THE STEERING GEAR ROOM, EMERGENCY GENERATOR ROOM, AND CO2 ROOM UNTIL ACCEPTABLE HEATING EQUIPMENT IS INSTALLED.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Lifesaving
Issued 14 December 1995 Resolved
INSULATE POTABLE WATER PIPING IN THE HOLD SPACES TO PREVENT CONDENSATION. THE INSULATION MUST BE APPROVED NONCOMBUSTIBLE.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Fire Fighting
Issued 14 December 1995 Resolved
EFFECT REPAIRS AND PROVE CORRECT OPERATION OF THE MAGNETIC LOCK ON THE DOORADJACENT TO THE SECURITY ROOM.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Electrical
Issued 14 December 1995 Resolved
INSTALL A METAL GUARD ON THE COOLER ROOM INCANDESCENT LIGHT FIXTURE.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Fire Fighting
Issued 14 December 1995 Resolved
MAKE SERVICE ELEVATOR ENCLOSURE MEET "A" CLASS STANDARDS IN THE HOLD SPACE.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Navigation
Issued 28 November 1995 Resolved
PROVE PROPER OPERATION OF THE MODIFIED STEERING SYSTEM PRIOR TO UNDERWAY OPERATIONS.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Navigation
Issued 28 November 1995 Resolved
PROVIDE APPROVED PLANS FOR THE STEERING CONTROLS MODIFICATIONS.
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995
Fire Fighting
Issued 28 November 1995 Resolved
MAKE CORRECTIONS TO INTERFERENCES WITH THE COOKSON SHUTTERS. THE SHUTTERS SHALL BE OPERATED IN THE FAIL SAFE MODE (SECURE POWER) BEFORE CORRECTIONS HAVE BEEN AND PROVEN TO THE SATISFACTION OF THE OCMI.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Electrical
Issued 28 November 1995 Resolved
RESUBMIT A REVISED A/C LOAD ANALYSIS WITH THE GENERATOR CAPACITY PROPOSAL.
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995
Engineering
Issued 28 November 1995 Resolved
MAKE PERMANENT REPAIRS TO THE BOW THRUSTER PRIOR TO UNDERWAY OPERATIONS.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Lifesaving
Issued 28 November 1995 Resolved
INSTALL TWO PFD STOWAGE BOXES AND STOW PFD'S ON THE TEXAS DECK IAW THE APPROVED FIRE CONTROL PLAN PRIOR TO UNDERWAY OPERATIONS.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Electrical
Issued 28 November 1995 Resolved
PROVIDE THE OCMI A WRITTEN STATEMENT ADDRESSING WHAT ACTIONS ARE BEING TAKEN TO PREVENT LOSS OF POWER BEFORE THE SHIP'S SERVICE GENERATOR POWER REQUIREMENTS ARE SATISFIED.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Electrical
Issued 28 November 1995 Resolved
PROVIDE PROPOSAL TO INCREASE THE GENERATOR CAPACITY TO COMPLY WITH 46 CFR 111.10-4: WITH ANY SHIP'S GEN SET STOPPED, THE REMAINING SETS MUST CARRY THE SHIP'S SERVICE LOAD. OR OTHER ACCEPTABLE MEANS SUCH AS LOAD SHEDDING TOPREVENT OVERLOAD IF ONE GENERATOR FAILS.
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995
Electrical
Issued 1 November 1995 Resolved
INSTALL A LATCH ON THE PANEL BOX IN THE CO2 ROOM.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
MOUNT THE UPS REGULATOR IN THE CO2 ROOM.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Lifesaving
Issued 1 November 1995 Resolved
PROVE PROPER OPERATION OF THE ENGINE MONITORING SYSTEM.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Lifesaving
Issued 1 November 1995 Resolved
INSTALL 2 GENERAL ALARM BELLS ON THE TEXAS DECK IN THE AREA OF THE AFT STACKS AND 2 BELLS MIDSHIP ON THE MAIN DECK EXTERIOR WALK WAYS.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
LABEL ALL ELECTRICAL CONTROL BOXES FOR THE VENT SYSTEM.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Fire Fighting
Issued 1 November 1995 Resolved
FIRE CAULK AND INSULATE THE STUFFING TUBES AT THE BULKHEAD OVER THE PORT FORWARD STAIRWAY ON THE HURRICANE DECK.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Fire Fighting
Issued 1 November 1995 Resolved
SATISFACTORILY TEST THE COOKSON SHUTTER SYSTEM.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
MOUNT PANEL COVERS ON THE POWER PANELS INSIDE THE CCTV ROOM.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
PLACE BREAKER PLUGS IN THE POWER PANELS LOCATED IN THE TELEPHONE ROOM AFT OF THE PILOT HOUSE.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Fire Fighting
Issued 1 November 1995 Resolved
SATISFY COMMENT 2 OF THE MARINE SAFETY CENTER LETTER SERIAL # E2-9503937 DATED OCTOBER 31, 1995 CONCERNING THE FIRE DETECTION SYSTEM.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Fire Fighting
Issued 1 November 1995 Resolved
CONDUCT SATISFACTORY DRILLS WITH THE CREW BEFORE OPERATING IN EVANSVILLE. 46 CFR 78.17-50
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
LABEL ALL ELECTRICAL BREAKERS, SWITCHES, AND PANELS.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
LABEL THE FIRE DETECTION SYSTEM, SPRINKLER SYSTEM, SMOKE DETECTION SYSTEM, AND GENERAL ALARM PANEL CIRCUIT DESIGNATION.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Fire Fighting
Issued 1 November 1995 Resolved
INSTALL A COVER PLATE ON THE PORT MAIN DECK FIRE SCREEN DOOR MAGNET.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Lifesaving
Issued 1 November 1995 Resolved
INSTALL AND TEST THE AEVADS SYSTEM IAW APPROVED PLANS.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
THE REHEATER SYSTEM SHALL BE TAGGED OUT AND NOT USED UNTIL THE SYSTEM CAN BE OPERATED WITHOUT LOAD FLUCTUATIONS INHIBITING THE PROPER OPERATION OF THE S/S GENERATING SYSTEM.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
REPLACE OR CALIBRATE THE #2 S/S GENERATOR KW METER.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
MOUNT THE TELEPHONE EQUIPMENT IN THE SPACE AFT OF THE BRIDGE.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
INSTALL A LATCH ON THE PANEL IN THE STARBOARD HURRICANE DECK PANEL ROOM.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
INSTALL PERMANENT WIRING TO THE RAMP WENCHES ON THE BOILER DECK.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
PLACE DIELECTRIC MATTING IN FRONT OF THE S/S AND EMERGENCY GENERATOR SWITCHBOARDS.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
MOUNT THE PANEL COVER ON THE POWER PANEL IN THE PORT MAIN DECK ELEVATOR ROOM.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Fire Fighting
Issued 1 November 1995 Resolved
INSTALL APPROVED FIRE STOP SYSTEMS (ROX BOX) BY THE PORT ELEVATOR PANEL ROOMS, 3RD DECK, 2ND DECK, AND PILOT HOUSE.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Engineering
Issued 1 November 1995 Resolved
SATISFY COMMENTS CONCERNING THE QUALITATIVE FAILURE ANALYSIS IN THE MARINE SAFETY CENTER LETTER, SERIAL # E2-9503957 DATED OCTOBER 31, 1995.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Lifesaving
Issued 1 November 1995 Resolved
EXCERCISE VESSEL CONTENGENCY PLAN TO THE SATISFACTION OF THE CAPTAIN OF THEPORT LOUISVILLE, KY.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Documentation
Issued 1 November 1995 Resolved
PROVIDE PERMANENT STABILITY LETTER BEFORE CARRIAGE OF PERSONS IN EXCESS OF TEMPORARY STABILITY LETTER (500) PERSONS.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Documentation
Issued 1 November 1995 Resolved
PROVIDE DRUG TEST RESULTS FOR THE REMAINDER OF THE CREW.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995