RIVERBOAT LOUIS ARMSTRONG

RIVERBOAT LOUIS ARMSTRONG is a 1995 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2018, most recently in August 2026, along with 15 deficiencies — 3 with no resolution recorded —.

Records from 2018 to 2026. Most recent: inspection, 4 August 2026.

Built
1995
Last inspected
4 August 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 August 2026
…past their stated due date2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK9914
430290
Flag
UNITED STATES
Maury page id
psix-430290

Documentation record

Registered dimensions (L × B × D)287.3 ft × 60.0 ft × 14.5 ft
Registered tonnagegross 1,589 / net 995
ITC dimensions (L × B × D)287.3 ft × 60.0 ft × 14.5 ft
ITC tonnagegross 7,389 / net 2,385
BuilderJEFFBOAT · JEFFERSONVILLE, IN, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 June 2025 · expires 30 June 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7389 - Convention (Subpart B), Gross Ton
1589 - Regulatory (Subpart C or D), Gross Ton
2385 - Convention (Subpart B), Net Ton
995 - Regulatory (Subpart C or D), Net Ton
2744 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

4 August 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8455037
17 June 2025 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8160932
2 April 2025 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8104048
23 December 2024 Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8050333
6 November 2024 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8031538
30 July 2024 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7970551
20 February 2024 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7851717
10 October 2023 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7806202
25 July 2023 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7734491
14 June 2023 Deficiency Check · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7715918
9 March 2023 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7642110
22 November 2022 Periodic Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7598662
14 September 2022 Periodic Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7536417
13 June 2022 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7465443
21 April 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7428736
11 January 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7378438
22 September 2021 Administrative Inspection · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7318125
22 October 2018 Construction Oversight · MTSA Verification · Attraction Vessel Exam · COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6565939
28 February 2018 Internal Structural Exam · Examination of Repairs · Construction Oversight · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6363273

Deficiency record · 15

11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 30 January 2026 No resolution recorded
46CFR § 199.45 Tests and inspections of lifesaving equipment and arrangements.(a) Initial inspection. The initial inspection of lifesaving appliances and arrangements for certification includes a demonstration of—(6) The proper condition and operation of embarkation appliances, including embarkation ladders and marine evacuation systems; Make proper repairs to the STBD side embarkation gate damaged by earlier event and make proper repairs to the PORT side embarkation gate which is frozen by rust. Both gates are for the rescue boats.
Due 28 February 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 July 2025 Resolved
The vessel is not ready for a COI inspection, issues with Fire Doors, Deck coverings, water leaking in overheads and on electrical lighting, door closures broken, windows broken all the above items discussed with the crew and they were instructed to conduct a vessel survey and make the vessel ready for the Inspection. Call when the vessel is ready. To be completed within 30 days and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2025
Resolved 22 August 2025
Resolution: Subsequent Inspection for the COI a new 835 issued, this one cleared so not to duplicate the current 835 issued 22Aug25.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 July 2025 Resolved
§ 199.45 Tests and inspections of lifesaving equipment and arrangements. (b) Reinspections. Tests and inspections of the lifesaving equipment shall be carried out during each inspection for renewal of certification and periodic inspection, and shall include, as applicable, a demonstration of— (4) The proper servicing of each inflatable liferaft and inflatable lifejacket has been serviced as required under this chapter; The life rafts on board the vessel are over due for servicing and will be required to be serviced prior the the vessel getting underway and prior to carrying any passengers on board even dockside. This must be completed within 30 days of this 835 issue date by 10Aug25.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2025
Resolved 22 August 2025
Resolution: Life Rafts Serviced.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 17 June 2025 No resolution recorded
§ 72.01-15 Structural standards.(a) In general, compliance with the standards established by the American Bureau of Shipping, see subpart 70.35 of this subchapter, will be considered satisfactory evidence of the structural efficiency of the vessel. However, in special cases, a detailed analysis of the entire structure or some integral part may be made by the Coast Guard to determine the structural requirements. Make the temp. repairs to the main deck BLKHDS Around Vessel IAW 17Nov25 repair proposal.
Due 28 February 2026 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › General alarm
Issued 14 January 2025 Resolved
§ 113.25-9 Location of general emergency alarm signal. General emergency alarm signal must:(a) Be located in passenger and crew quarters areas where they can alert persons in spaces where those persons may be maintaining, repairing, or operating equipment, stowing or drawing stores or equipment, or transiting, such as public spaces, work spaces, machinery spaces, workshops, galleys, emergency firepump room, bow thruster rooms, storage areas for paint, rope, and other stores, underdeck passageways in cargo areas, steering gear rooms, windlass rooms, holds of roll-on/roll-off vessels, and, except those that are accessible only through bolted manhole covers, duct keels with valve operators; and (b) Be audible in the spaces identified in paragraph (a) of this section with all normally closed doors and accesses closed; and (c) Be installed in cabins without loudspeaker installation. Other audible devices, such as electronic alarm transducers, are permitted. Currently 15 alarm bells are not working or not working properly. Make repairs and re-schedule the quarterly inspection within 2 weeks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2025
Resolved 16 January 2025
Resolution: Inspected and tested entire general alarm system. Operator replaced two 12v batteries new and replacement the battery charging system for the general alarm batteries. All found in satisfactory condition.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 July 2023 No resolution recorded
§ 78.37-5 Actions required to be logged. The actions and observations noted in this section shall be entered in the official log book. This section contains no requirements which are not made in other portions of this subchapter, the items being merely grouped together for convenience. (a) Onboard training, musters, and drills: held in accordance with subchapter W (Lifesaving Appliances and Arrangements) of this chapter. VESSEL IS RESTRICTED IN OPERATIONS THAT REQUIRE THE VESSEL TO GET UNDERWAY UNTIL ALL REQUIRED FIRE/SAFETY/ABANDON SHIP/SECURITY DRILL HAVE BEEN WITNESSED BY THE USCG. CONTACT SECTOR NEW ORLEANS DISPATCHER OFFICE WHEN THE DEFICIENCY IS TO BE CLEARED.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 March 2023 Resolved
46 CFR 111.10-3 Power Supply. In addition to the emergency power sources required under part 112 of this chapter, each self-propelled vessel and each mobile offshore drilling unit must have at least two electric generating sources. Currently the SSDG's on board are not operating properly and cannot be paralleled either automatically or manually. Make repairs to the operation of these three SSDG's so the parallel operation is working properly. Prior to the vessel getting underway with passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2023
Resolved 11 April 2023
Resolution: Shore tie bus breaker failed and was replaced in kind.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 March 2023 Resolved
46CFR 113.40-5 General requirements. The position of the rudder, if power-operated, must be shown at the principal steering station. If there is non-follow-up steering control at the alternative steering station, there must be a separate rudder angle indicator system for that station that is electrically independent from each other rudder angle indicator system. Currently the rudder angle indicators are not operating properly, make repairs to the indicators prior to getting the vessel underway with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2023
Resolved 11 April 2023
Resolution: EMI attended the vessel to re-calibrate. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 March 2023 Resolved
46 CFR111-30-25(e) (3) (f) For each shore power connection each switchboard must have: (1) A circuit breaker or fused switch; (2) A pilot light connected to the shore side of the circuit breaker or fused switch; and (3) One of the voltmeters under paragraph (b)(5) of this section connected to show the voltage of each phase of the shore power connection. Currently two of the shore tie breakers and connections are not working properly, make corrections/repairs within the next 30Days.
Action required: 705 - Other - as specified
Due 9 April 2023
Resolved 11 April 2023
Resolution: Shore tie was damaged when caught between the ship and the pier. Cut/spliced connection. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 March 2023 Resolved
46CFR199.630(a) in addition to the alternatives for certain requirements in § 199.620, passenger vessels operating in oceans; coastwise; Great Lakes; lakes, bays, and sounds; and rivers service may comply with alternative requirements to subparts A through C of this part as described in this section for the services specified in table 199.630(a) of this section. Currently there are no liferafts on board the vessel. Prior to getting underway install the required life rafts.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2023
Resolved 11 April 2023
Resolution: Liferafts received annual servicing and were properly installed onboard.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 March 2023 Resolved
46 CFR 72.05.50 Where automatic fire dampers are required, they shall be designed to operate at approximately 165 degrees F. for normal locations, and approximately 212 degrees F. for locations such as galleys. The dampers shall be so designed as to close against the anticipated draft in the duct. The damper shall be made accessible for periodic inspection by means of a hinged or bolted plate in the duct. The damper and the portion of duct containing the damper shall be constructed of at least 1/8 inch steel plate suitably stiffened. No insulation need be applied to the damper blade. Currently the damper on the 3rd deck is not operating properly and not allowing the complete zone to show Green on the control panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2023
Resolved 11 April 2023
Resolution: Replaced failed MC panel board.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 14 September 2022 Resolved
All lifesaving appliances and arrangements on passenger vessels must be in accordance with subchapter W (Lifesaving Appliances and Arrangements) of this chapter. Vessel did not have documentation that the weekly and monthly inspections required by 46 CFR 199.190(d) and (e) were completed. 46 CFR 70.28-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 6 October 2022
Resolution: Received evidence of new log and record keeping program onboard (with initial entries) to track lifesaving equipment inspection and maintenance.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 June 2022 Resolved
Currently the side shell fire door midship on the 2nd deck PORT side has been damaged and is not able to be closed or operated properly. Prior to operating the vessel with passengers, make proper repairs to the damaged fire door so it is closed and maintains the fire boundary. Since this door is only used while moored at the Hilton Docking facility and not used under way as an egress route the door may be made tight in a non operational way until a new door can be installed. Contact Tom Alho at [phone withheld] for proposed correction to this problem and it must be corrected prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2022
Resolved 16 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2021 Resolved
Currently the STBD main engine thruster control transducer is bad and will not allow pilot house control for this engine. The current module is obsolete and will have to be manufactured or a modification to the system installed. To be determined by cost of each. Prior to getting the vessel underway.
Due 13 November 2021
Resolved 15 November 2021
Resolution: Parts replaced and tested satisfactory to all satisfaction.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 13 October 2021 Resolved
. Currently the EDG switchboard breaker for the emergency fire pump trips immediately after the pump is energized when on the emergency source of power. Correct this issue and provide demonstration to the USCG. Prior to getting vessel underway.
Due 13 November 2021
Resolved 15 October 2021
Resolution: Main Breaker Amperage trip was adjusted to the needs of the system.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.