Records from 1982 to 2003. Most recent: inspection, 4 November 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
4 November 2003
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1941767
7 May 2003
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1788617
17 January 2003
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1730642
28 May 2002
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1602677
17 May 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1064204
19 April 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1066530
31 January 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1366148
11 July 2000
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1052878
27 June 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 820693
29 June 1999
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1082257
5 May 1999
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1429139
4 November 1998
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1034497
25 August 1998
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1409953
20 April 1998
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465389
25 June 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1112571
20 May 1997
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1380886
3 March 1997
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1470131
19 June 1996
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 886335
13 June 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1083085
14 May 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1434389
20 June 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1385487
12 May 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1443583
21 June 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1171212
29 December 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 853816
14 July 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1153850
17 May 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 834053
23 July 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151133
4 September 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1255495
11 October 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1345607
14 March 1988
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1336427
6 March 1987
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1323255
9 April 1986
Credit Drydock · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1307265
22 March 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1286633
2 March 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1278943
14 March 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968117
8 March 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277148
Communications › Radio Communications
Issued 15 April 2002
Resolved
Replace hydrostatic release on EPIRB. LEGACY COMPONENT DESC: EPIRB
Due 15 May 2002
Resolved 28 May 2002
Communications › Radio Communications
Issued 15 April 2002
Resolved
Replace battery o0n EPIRB LEGACY COMPONENT DESC: EPIRB
Due 15 May 2002
Resolved 28 May 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 15 April 2002
Resolved
Have all fie extingushers and fixed fire systems serviced LEGACY COMPONENT DESC: Service
Due 15 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 April 2002
Resolved
Provide proof of Red Cross CPR training.
Due 15 May 2002
Resolved 28 May 2002
Lifesaving › Liferaft Equipment
Issued 15 April 2002
Resolved
Stencil vessel name on life float paddling.
Due 15 May 2002
Resolved 28 May 2002
Personnel › Manning/Qualifications
Issued 15 April 2002
Resolved
Provide proof of drug testing LEGACY COMPONENT DESC: Medical Fitness
Due 15 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 April 2002
Resolved
Replace all expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 15 May 2002
Resolved 28 May 2002
Operations/Management › Navigation Safety
Issued 15 April 2002
Resolved
Provide updated navigation publications LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 15 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety
Issued 19 April 2001
Resolved
PROVIDE MARKINGS ON EMERGENCY ESCAPE HATCH AS REQUIRED BY 46 CFR 185.606.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Documentation
Issued 19 April 2001
Resolved
PROVIDE PROPER FCC DOCUMENTATION ( SAFETY RADIO TELEPHONE CERTIFICATE ) AS REQUIRED BY 47 CFR 80
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 19 April 2001
Resolved
PROPERLY STOW BUOYANT APPARATUS LIFELINE AND PENDANTS, PROVIDE (2) OARS TIED TO BA, RESPLICE WATER LIGHT LINE AS REQUIRED BY 46 CFR 180.200._x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Electrical
Issued 19 April 2001
Resolved
PROVIDE PROPER WIRING/CABLE INSTALLATION ON AIR COMPRESSOR AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 19 April 2001
Resolved
PROVIDE EQUIPMENT FOR SKIFFS AS REQUIRED BY 33CFR SUBCHAPTERS S_x001C_ CORRECT PRIOR TO OPERATING SKIFFS.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Electrical
Issued 19 April 2001
Resolved
PROVIDE JARS AND GUARDS ON LIGHTS IN ACCOMODATION SPACE AS REQUIRED BY 46 CFR 183.410.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 5 May 1999
Resolved
PROVIDE CAPTIVE CHAINS FOR THE DECK HATCHES.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Navigation
Issued 5 May 1999
Resolved
MAKE THE STEERING POST READILY ACCESSABLE TO INSTALL EMERGENCY TILLER IN ANEMERGANCY.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Lifesaving
Issued 5 May 1999
Resolved
RENEW ORANGE SMOKE FLARES.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Lifesaving
Issued 5 May 1999
Resolved
RENEW EPIRB REGISTRATION AND HYDROSTATIC RELEASE.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Lifesaving
Issued 5 May 1999
Resolved
RELABLE PADDLES WITH VESSELS NAME AND PROVIDE AND PROPERLY INSTALL PENDANTSASD PER 160.027.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Fire Fighting
Issued 5 May 1999
Resolved
PROVIDE A WORKING SMOKE DETECTOR FOR THE PASSENGER BERTHING SPACE.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Engineering
Issued 5 May 1999
Resolved
READJUST SHAFT PACKING TO REDUCE AMOUNT OF LEAKAGE.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Deck/Cargo
Issued 5 May 1999
Resolved
PROVIDE AND INSTALL A GUARD OVER THE BELT DRIVE FOR THE AIR COMPRESSOR.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Engineering
Issued 5 May 1999
Resolved
PROPERLY LABLE REMOTE FUEL SHUT OFF VALVES.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Construction/Loadline
Issued 5 May 1999
Resolved
SEAL ALL BULKHEAD PENETRATIONS IN THE ENGINE ROOM.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Construction/Loadline
Issued 5 May 1999
Resolved
INSTALL AN ADDITIONAL BILGE ALARM SWITCH FOR EACH COMPARTMENT CONTAINING THROUGH HULL FITTINGS.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Electrical
Issued 5 May 1999
Resolved
PROPERLY WIRE THE AIR COMPRESSOR.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Electrical
Issued 5 May 1999
Resolved
PROPERLY LABEL ALL POWER PANELS.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Documentation
Issued 5 May 1999
Resolved
RENEW RADIO STATION LICENSE 47CFR80.15
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Electrical
Issued 5 May 1999
Resolved
PROVIDE GLOBES AND GUARDS FOR LIGHT FIXTURES.
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Navigation
Issued 5 May 1999
Resolved
REPAIR STEERING TO REMOVE EXCESS PLAY FROM LINKAGE
Condition: Unknown
Due 5 June 1999
Resolved 30 June 1999
Lifesaving
Issued 20 April 1998
Resolved
PROVIDSE ON BOARD A COAST GUARD APPROVED FIRST AID KIT OR ALL ITEMS REQUIRED BY 46 CFR 160.041.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Fire Fighting
Issued 20 April 1998
Resolved
PROVIDED DOCUMENTATION THAT THE PORTABLE EXTINGUISHERS HAVE BEEN SERVICED. 46 CFR 176.810
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Lifesaving
Issued 20 April 1998
Resolved
RENEW SEA PAINTER FOR LIFE FLOAT. 46 CFR 180.137.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Engineering
Issued 20 May 1997
Resolved
PROPERLY GROUND FUEL TANK FILL PORT IAW 46 CFR 182.445
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Lifesaving
Issued 20 May 1997
Resolved
PROVIDE COAST GUARD APPROVED TYPE I PFD'S IAW COI FOR ALL SKIFFS ON BOARD.
Condition: Unknown
Due 13 June 1997
Resolved 30 May 1997
Engineering
Issued 20 May 1997
Resolved
INSTALL MACHINERY GUARDS AROUND EXPOSED PULLEYS ON THE MAIN ENGINE IAW 46 CFR 176.830.
Condition: Unknown
Due 13 June 1997
Resolved 30 May 1997
Electrical
Issued 20 May 1997
Resolved
INSTALL EMERGENCY LIGHTING IN THE OVERNIGHT ACCOMMODATION COMPARTMENTS IAW 46 CFR 183.432
Condition: Unknown
Due 13 June 1997
Resolved 30 May 1997
Documentation
Issued 20 May 1997
Resolved
PROVIDE AND USE AN UP TO DATE TRAINING LOG IAW 46 CFR 185.420
Condition: Unknown
Due 13 June 1997
Resolved 29 May 1997
Documentation
Issued 20 May 1997
Resolved
PROVIDE DONNING PLACARDSFOR EACH STYLE LIFE JACKET CARRIED ON BOARD IAW_x001C_ 46 CFR 185.516
Condition: Unknown
Due 13 June 1997
Resolved 29 May 1997
Documentation
Issued 20 May 1997
Resolved
PROVIDE AND USE AN EPIRB TEST LOG IAW 46 CFR 185.728
Condition: Unknown
Due 13 June 1997
Resolved 29 May 1997
Navigation
Issued 20 May 1997
Resolved
PROVIDE UP TO DATE NAVIGATION CHARTS & PUBLICATIONS IAW 46 CFR 184.420
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Documentation
Issued 20 May 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Documentation
Issued 20 May 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 June 1997
Resolved 29 May 1997
Construction/Loadline
Issued 3 March 1997
Resolved
THE VESSEL'S BILGE SUCTION DID NOT HAVE STRAINERS INSTALLED. INSTALL STRAINERS OF THE PROPER SIZE IAW 46 CFR 182.510(b).
Condition: Unknown
Due 3 April 1997
Resolved 17 April 1997
Fire Fighting
Issued 3 March 1997
Resolved
THE VESSEL WAS MISSING ONE B-I AND ONE B-II PROTABLE FIRE EXTINGUISHERS. PROVIDE ONBOARD THE VESSEL THE PROPER FIRE EXTINGUISHERS IAW 46 CFR 181.500.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Construction/Loadline
Issued 3 March 1997
Resolved
THE COAMING ON THE FOREPEAK W/T HATCH WAS ROTTED. REMOVE AND RENEW COAMINGAS ORIGINAL IAW COAST GUARD NVIC 7-95.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Engineering
Issued 3 March 1997
Resolved
THE VESSEL'S FUEL SYSTEM HAS PETCOCK VALVES INSTALLED ON THE FUEL STRAINERS. REOVE ALL PETCOCKS FROM THE FUEL STRAINER IAW 46 CFR 182.455(b)(9).
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Navigation
Issued 3 March 1997
Resolved
THE COMPASS DID NOT HAVE A LIGHT. PROVIDE, INSTALL AND PROVE OPERATION OF THE COMPASS LIGHT IAW 46 CFR 184.402.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Lifesaving
Issued 3 March 1997
Resolved
THE LIFEFLOAT DID NOT HAVE A WATERLIGHT INSTALLED. PROVIDE AND PROPERLY INSTALL A WATERLIGHT ON THE LIFEFLOAT IAW 46 CFR 180.175(d).
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Construction/Loadline
Issued 3 March 1997
Resolved
THE THIRD PORTSIDE FRAME IN THE FORPEAK WAS ROTTED. FRAME WAS RENEWED.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
THE AFT MAIN DECK BEAM LOCATED IN THE STEERING SPACE WAS ROTTED. BEAM WAS RENEWED AS ORIGINAL.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Lifesaving
Issued 3 March 1997
Resolved
THE VESSEL'S LIFEFLOAT DID NOT HAVE ANY PADDLES IAW 46 CFR 180.175. PROVIDE2 PADDLES AND PROPERLY MARK WITH VESSEL NAME IAW 46 CFR 185.604.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Construction/Loadline
Issued 3 March 1997
Resolved
THE THIRD PLANK FROM THE MAIN DECK 12 FT AFT OF THE STEM ON TH PORTSIDE WASFOUND FRACTURED. PLANKE WAS RENEWED AS ORIGINAL.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
THE AFT PORTSIDE VERTICLE FRAME LOCATED IN THE STEERING SPACE WAS ROTTED AND INFESTED WITH WHARF BORE WORMS. VESSEL WAS FUMIGATED AND FRAME WAS REPAIRED.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
THE DISCHARGE LINE FOR THE RESENTLY INSTALL SUBMERSIBLE ELECTRIC BILGE PUMPS IS NOT SUITABLE FOR THE INTENDED USE AND NO POSITIVE SHUTOFF VALVES WERE INSTALLED. RENEW PUMP DISCHARGE FLEX HOSE AND INSTALL POSITIVE SHUTOFF VALVE IAW 46 CFR 182.(e)(7) AND (f).
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Engineering
Issued 3 March 1997
Resolved
THE FUEL TANK VENT DID NOT HAVE A FLAME SCREEN INSTALLED. PROPERLY INSTALLA 30X30 MESH FLAME SCREEN ON FUEL TANK VENT IAW 46 CFR 182.450(e).
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Construction/Loadline
Issued 3 March 1997
Resolved
RENEW OR REPAIR AS ORIGINAL THE WASTED GALLEY OVERHEAD PANELS.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Electrical
Issued 3 March 1997
Resolved
THE SERVICE GENERATOR PULLEY SYSTEM WAS MISSING ITS MANUFACTURE SUPPLIES GUARD. PROVIDE AND INSTALLA SUITABLE GUARD OVER THE SERVICE GENERATOR PULLEYSYSTEM IAW 46 CFR 177.690.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Construction/Loadline
Issued 3 March 1997
Resolved
THE VESSEL DID NOT HAVE A HAND BILGE PUMP. PROVIDE AND PROVE PROPER OPERATION OF A HAND BILGE PUMP CAPABLE OF REACHING ALL COMPARTMENTS IAW 46 CFR 182.520.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Construction/Loadline
Issued 3 March 1997
Resolved
THE VESSEL WAS INFESTED WITH WHARF BORERS. VESSEL WAS FUMIGATED WITH VIKANE GAS BY BAY PEST CONTROL.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
SEVERAL AREAS WITHIN THE VESSEL HAVE LARGE AMOUNTS OF ANGLE HAIR FUNGUS ON THE OVERHEAD, FRAMES AND INTERIOR HULL PLANKS. REMOVE ALL FUNGUS AND TREATWOOD TO PREVENT REINFESTATION IAW COAST GUARD NVIC 7-95 5.7.I.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Construction/Loadline
Issued 3 March 1997
Resolved
SEVERAL LOCATIONS ON BOTH THE PORT AND STBD GUNWHALE CAPS ARE ROTTED. REMOVE WOOD ROT AND PROPERLY REPAIR GUNWHALES IAW COAST GUARD NVIC 7-95 CHAPTER 5.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Engineering
Issued 3 March 1997
Resolved
THE AFT PROP SHAFT PILLAR BEARING WAS NOT SECURELY FASTENED TO THE KEEL ANDWAS MOVING UP AND DOWN. PROPERLY REFASTEN PILLAR BEARING IAW 46 CFR 176.610.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Engineering
Issued 3 March 1997
Resolved
BOTH THE PORT AND STBD FUEL TANKS WERE FOUND WASTED. THE STBD TANK PIPING AND INSPECTION PLAES WERE REMOVED AND BALLAST INSTALLED. A NEW TOP, BOTTOMAND BAFFLE PLATES WERE INSTALLED ON THE PORT FUEL TANK.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
THE MAIN DECK WATERTIGHT HATCHES WERE MISIING GASKETS AND HOLD DOWN SCREWS.OWNER INSTALL NEW WATERTIGHT HATCHES.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
SEVERAL AREAS OF THE MAINDECK WERE FOUND TO BE ROTTED. OWNER RENEWED EFFECTED AREAS OF THE DECK.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Lifesaving
Issued 3 March 1997
Resolved
THE LIFE RING BUOY HAS SEVERAL TEARS IN THE COVER. PROPERLY REPAIR OR RENEW LIFE RING BUOY AND PROPERLY ATTACH WATERLIGHT IAW 46 CFR 180.70.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Construction/Loadline
Issued 3 March 1997
Resolved
FOUND APPROXIMATELY 30 CLAMP FASTENERS WASTED THROUGHOUT THE VESSEL. ALL WASTED FASTENERS WERE RENEWED AS ORIGINAL.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
SEVERAL MAIN DECK STANTION WERE ROTTED. ALL WASTED STANTIONS WERE REPAIRED.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
THE SECOND MAIN DECK BEAM LOCATED IN THE FORPEAK WAS ROTTED. FRAME WAS RENEWED.
Condition: Unknown
Due 3 March 1997
Resolved 17 April 1997
Lifesaving
Issued 14 May 1996
Resolved
PROVIDE PYRO FOR ALL SMALL BOATS.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Unknown
Issued 14 May 1996
Resolved
PROVIDE AND INSTALL GUARD FOR FRESH WATER PUMP.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Engineering
Issued 14 May 1996
Resolved
PROVIDE AND INSTALL 30"X30" SCREENS IN MSD AND FUEL OIL VENTS.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Engineering
Issued 14 May 1996
Resolved
REPAIR FUEL OIL HOSES ON MAIN ENGINES AND GENERATORS WITH PROPER HOSES AND FITTINGS.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Engineering
Issued 14 May 1996
Resolved
REMOVE PETCOCK FROM GENERATOR FUEL FILTER AND REPLACE WITH PLUG.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Construction/Loadline
Issued 14 May 1996
Resolved
PROVIDE AND INSTALL DOUBLE HOSE CLAMPS AS NEEDED WITHIN 18 INCHES OF VSL WATER LINE.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Navigation
Issued 14 May 1996
Resolved
PROVIDE AND INSTALL GUARD FOR STEERING GEER IN FORWARD CREW QUARTERS.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Engineering
Issued 14 May 1996
Resolved
PROVIDE AND INSTALL GUARD FOR GENERATOR.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Lifesaving
Issued 14 May 1996
Resolved
PROVIDE HEAVY METAL OR HEAVY PLASTIC CONTAINER FOR VSL PYRO.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Construction/Loadline
Issued 12 May 1995
Resolved
RELOCATE SANITARY SYSTEM INTAKE AND DISCHARGE 3 INCH PIPING SHUT OFF VALVESAS CLOSE AS PRACTICABLE TO THEIR THRU HULL FITTINGS.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Engineering
Issued 12 May 1995
Resolved
PROVIDE PERSONNEL PROTECTIVE GUARDS AT AIR COMPRESSOR GENERATOR AND MDE DRIVE BELTS AND PULLEYS.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Electrical
Issued 12 May 1995
Resolved
PROVIDE PROPER SPLICES AND JUNCTION BOXES FOR SUBMERSIBLE BILGE PUMP WIRINGAND TANK COMPARTMENT.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Construction/Loadline
Issued 12 May 1995
Resolved
PROVIDE REACH RODS FOR SANITARY INTAKE AND DISCHARGE 3 INCH PIPING SHUT OFFVALVES AT THRU HULL LOCATIONS.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Fire Fighting
Issued 21 June 1994
Resolved
PRIOR TO CARRYING PASSENGERS COMPLETE REQUIRED DRILLS WITH THE FULL CREW ONBOARD. THIS TO BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR NO LATER THAN 25MAY95.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Construction/Loadline
Issued 17 May 1993
Resolved
REPLACE ALL FLEXIBLE HOSE IN BILGE PIPING WITH RIDIG PIPING. THIS TO BE COMPLETED NOT LATER THAN 17JUL93 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Construction/Loadline
Issued 9 April 1986
Resolved
REMOVE THE TWO FIXED GASOLINE FUEL TANKS LOCATED UNDER THE FAINTAIL FROM THE VESSEL.
Condition: Unknown
Due 9 April 1986
Resolved 9 April 1986