Inspection history · 23
8 May 2026
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8357937
4 March 2026
Inclining Experiment
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8319061
27 June 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7966071
11 July 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7780472
3 January 2023
Examination of Repairs · Damage Survey · Deadweight Survey · Plan Review "T" Boat
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7648412
30 August 2022
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7582629
1 December 2021
Drydock Extension · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7369005
10 December 2020
Deadweight Survey · Administrative Inspection · Examination of Repairs · Plan Review "T" Boat · COI Inspection · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7173667
13 October 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7076302
30 September 2020
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7068384
3 February 2020
Examination of Repairs · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6902573
6 May 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6782075
25 April 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6399855
18 April 2018
Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6399881
2 November 2017
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6302803
24 May 2017
COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6146807
1 February 2017
Administrative Inspection · Inclining Experiment · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6146671
27 December 2016
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6062676
8 November 2016
Examination of Repairs · Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6049474
14 September 2016
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6000893
9 September 2016
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5996570
12 February 2016
Construction Oversight · Deadweight Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5996583
13 January 2016
Plan Review "T" Boat
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5802926
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 July 2023
Resolved
Generator side of genset is dirty, creating a fire hazard, must be cleaned.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 17 July 2023
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 August 2022
Resolved
#4 void bilge alarm inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2022
Resolved 30 August 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 August 2022
Resolved
E/R wire runs need to be properly routed through WTB's &/or properly terminated/removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2022
Resolved 30 August 2022
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 August 2022
Resolved
Several PFE brackets are broken, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2022
Resolved 1 September 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 30 August 2022
Resolved
All bilges were extremely dirty, causing potential bilge plumbing clogs. All bilges need to be cleaned.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2022
Resolved 4 October 2022
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 August 2022
Resolved
Shaft compartment has pitting & wastage in the port side forward bay, outboard of girder.
** closely examine at upcoming phase II steel work project.**
Action required: 705 - Other - as specified
Due 31 December 2022
Resolved 13 March 2025
Resolution: wasted are of hull plate & assoc. structures have been cropped & renewed. NDT witnessed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 August 2022
Resolved
Charts require updating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2022
Resolved 4 October 2022
Resolution: corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 30 August 2022
Resolved
Crew requires hazmat training every 3 years. All 3 crew members have expired training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2022
Resolved 1 September 2022
Resolution: completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 30 September 2020
Resolved
Drain for the steering gear space is leaking into the lazarette. Determine cause and make drain watertight again to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 7 October 2020
Resolution: Welded closed. Wated drains out of the stbd drain now. Will need to be fixed during drydock.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 30 September 2020
Resolved
Window in the passenger cabin is broken. Replace broken window.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 3 September 2021
Resolution: Received photo from vessels primary Master depicting window satisfactory replacement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 30 September 2020
Resolved
Bow is missing bottom vehicle retention chain. Replace chain.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 7 October 2020
Resolution: Chain replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 30 September 2020
Resolved
Escape hatch from the engine room must be labeled with "EMERGENCY EXIT, KEEP CLEAR" in 2 inch letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 13 October 2020
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 30 September 2020
Resolved
Plywood cargo door on port side has reached its service life and is no longer properly securing the access. Replace door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 7 October 2020
Resolution: replaced.
12 - Dangerous Goods › N/A - No Subsystem › Special requirement
Issued 30 September 2020
Resolved
Failure to ensure that each employee has received required training prior to transporting a hazardous material by vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 26 July 2021
Resolution: corrected, all employees have received the required training.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 March 2020
Resolved
Vessels maindeck and associated structures have cracking and corrosion IWO doubler plate, suspected hull plating wastage in the #4 void and wasted associated structures, temporary repair of fwd fuel tank bulkhead. As agreed upon during Feb-March 2020 damage survey, emergency dry-docking and subsequent repairs, Owner must make vessel available for credit hull exam no later than 31 December 2020. Hull exam and subsequent repairs shall be in accordance with the submitted/approved Naval Architect plans and fuel tank bulkhead crop/renewal at a minimum, and additional repairs as called out by the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 19 August 2021
Resolution: Resolved. Re-issued for main deck and above requirements.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 February 2020
Resolved
Submit repair proposal and effect permanent repairs in accordance with approved proposal to damaged, fractured and wasted structures and main deck IWO forepeak and #2 void (port forward main deck and vent area).
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2020
Resolved 13 March 2020
Resolution: repaired, see activity narrative.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 February 2020
Resolved
Make vessel available for inspection and further assessment of suspected wastage of hull plating and associated structures in #4 void, port forwardmost bay. Submit proposal and effect permanent repairs as applicable if CG Marine Inspector requires.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2020
Resolved 13 March 2020
Resolution: repaired, see activity narrartive.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 April 2018
Resolved
Properly secure lifefloat beacon bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 2 May 2018
Resolution: secured.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 April 2018
Resolved
Fabricate and install removeable bow railing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2018
Resolved 16 May 2018
Resolution: Received photo of fabricated railings (chain). Inspector to visually inpsect in person this Friday.
Fire Fighting › Fire Pumps › Pressure
Issued 25 April 2018
Resolved
Make emergency fire pump pressure gauge operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 2 May 2018
Resolution: replaced gauge, ops check good.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 April 2018
Resolved
Remove excess oil/water mixture from engineroom bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 2 May 2018
Resolution: corrected.
Documentation › Markings/Placards › Warning Signs
Issued 25 April 2018
Resolved
Properly label genset with de-rating placard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 2 May 2018
Resolution: completed.
Construction/Loadline › Structures › Deck Plating
Issued 18 April 2018
Resolved
Maintain wooden wedge temporary repairs to deck fractures in way for starboard bow, upon which vessel may operate only until the end of day 18APR2018.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2018
Resolved 19 April 2018
Construction/Loadline › Structures › Deck Plating
Issued 18 April 2018
Resolved
Prior to operating on or after 19APR2018, complete temporary repairs to deck and moorings fixtures at starboard bow, to satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2018
Resolved 19 April 2018
Resolution: Attended vessel 19APR, repairs to be further examined at upcoming annual inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2017
Resolved
Replace expired items in first-aid kit
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 26 May 2017
Resolution: replaced
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2017
Resolved
Provide protection on hot piping for main engine cooling, as to prevent injury.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 26 May 2017
Resolution: installed
Engineering › Bilge Water Management System › Piping
Issued 24 May 2017
Resolved
Demonstrate proper operation of bilge piping from all compartments. Bilge piping components fractured from freezing during winter layup.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 26 May 2017
Resolution: corrected and tested, all sat
Navigation › Piloting/Steering › Magnetic Compass
Issued 24 May 2017
Resolved
Demonstrate proper operation of compass light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 26 May 2017
Resolution: corrected
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 May 2017
Resolved
Provide reto-reflective marking on ring life buoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 26 May 2017
Resolution: corrected
Fire Fighting › Fire Hydrants › Condition
Issued 24 May 2017
Resolved
Repair leaking fire hydrant valve below ladder on maindeck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 26 May 2017
Resolution: repaired and tested, all sat
Engineering › Steering Gear System › Rudder Stock
Issued 24 May 2017
Resolved
Make permanent repair to main steering quadrant in way of connection to rudder stock and demonstate proper operation of same.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 26 May 2017
Resolution: repaired and tested, all sat
Fire Fighting › Fire Hoses › Condition
Issued 24 May 2017
Resolved
Starboard main deck fire hose excessively worn, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 24 May 2017
Resolved 24 May 2017
Resolution: corrected during inspection
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 May 2017
Resolved
Personal electronics and misc gear stowed in windshiedl, distracting master and partially obstructing view from operating station, cleared away and corrected during inspection.
Condition: Improper Installation
Due 24 May 2017
Resolved 24 May 2017
Resolution: corrected during inspection.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 24 May 2017
Resolved
Mounting bracket bent, inoperable for BI PFE at operating station, corrected during inspection
Condition: Improper/Lack of Maintenance
Due 24 May 2017
Resolved 24 May 2017
Resolution: corrected during inspection
Fire Fighting › Fire Hoses › Condition
Issued 9 September 2016
Resolved
Replace broken fire hose reel at starboard main deck fire station.
Condition: Improper/Lack of Maintenance
Due 16 September 2016
Resolved 14 September 2016
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 9 September 2016
Resolved
Repair excessively loose conduit for AC and DC electrical systems in engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 14 September 2016
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 9 September 2016
Resolved
Make man-overboard recovery ladder and system safe for use and demonstrate proper function of same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 14 September 2016
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 September 2016
Resolved
Provide records of crew training and drills as per 46 CFR 185.420; .520; and .524.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 14 September 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 September 2016
Resolved
Make vessel and crew available to demonstrate satisfactory drills for fire, man-overboard recovery abandon ship scenarios.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 14 September 2016
Documentation › Certificates/Documents › Stability Letter
Issued 9 September 2016
Resolved
Stability letter and addendum faded and illegible, replaced during inspection.
Condition: Improper/Lack of Maintenance
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection.
Lifesaving › Lifefloat › Float Free
Issued 9 September 2016
Resolved
Life float secured with bungee cord, not float free, stowage not adequate to prevent damage, paddles not lashed to the float, all corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection
Lifesaving › Lifebuoys › Stowage
Issued 9 September 2016
Resolved
Ring bouy stowed improperly port side of wheelhouse. Lifeline tangled in handrailing, floating light attachment clip corroded. Corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Securing Means
Issued 9 September 2016
Resolved
Wheeled semi-portable BV Dry Chemical fire extinguisher improperly secured with ratchet strap around high pressure nitrogen cylinder, corrected during inspection.
Condition: Improper Installation
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 September 2016
Resolved
Fuel shut off valve inoperable by remote means, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection.
Stability › Watertight Integrity › General
Issued 9 September 2016
Resolved
Starboard deck hatch to void space forward of engineroom not watertight, broken gasket, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection.
Stability › Intact Righting Energy › General
Issued 23 August 2016
Resolved
Demonstrate vessel stability meets 46 CFR 178.310, meanwhile carry not more than 75 long tons deck cargo and comply with existing stability letter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 13 March 2017
Resolution: Sighted new stability ltr issued by the MSC.