← All vessels
W.S. WOODFILL
Passenger (Inspected) · Passenger Ship class · Built 1950s · USCG Great Lakes District (CGD-GL) · Other hulls named W.S. WOODFILL
W.S. WOODFILL is a 1955 passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 1985, most recently in May 2026, along with 183 deficiencies and 7 casualty investigations between 2011 and 2015.
Records from 1985 to 2026. Most recent: inspection, 8 May 2026.
- Built
- 1955
- Last inspected
- 8 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 183 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 7 investigations · 2011–2015
Identity
269660
WDI5217
43050
Flag
UNITED STATES
367706320
Maury page id
psix-43050
Inspections, by type
…with no type recorded17
Years with a record
38 calendar years (1985–2026)
The 94 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)91.8 ft × 33.1 ft × 8.1 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1955
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMACKINAC ISLAND, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
98 - Displacement, Ton
66 - Regulatory (Subpart C or D), Net Ton
98 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI5217MMSI 367706320 · active · compulsorily equipped · granted 8 January 2026, expires 10 December 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 94
8 May 2026
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8357937
4 March 2026
Inclining Experiment
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8319061
27 June 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7966071
11 July 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7780472
3 January 2023
Examination of Repairs · Damage Survey · Deadweight Survey · Plan Review "T" Boat
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7648412
30 August 2022
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7582629
1 December 2021
Drydock Extension · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7369005
10 December 2020
Deadweight Survey · Administrative Inspection · Examination of Repairs · Plan Review "T" Boat · COI Inspection · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7173667
13 October 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7076302
30 September 2020
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7068384
3 February 2020
Examination of Repairs · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6902573
6 May 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6782075
25 April 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6399855
18 April 2018
Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6399881
2 November 2017
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6302803
24 May 2017
COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6146807
1 February 2017
Administrative Inspection · Inclining Experiment · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6146671
27 December 2016
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6062676
8 November 2016
Examination of Repairs · Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6049474
14 September 2016
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6000893
9 September 2016
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5996570
12 February 2016
Construction Oversight · Deadweight Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5996583
13 January 2016
Plan Review "T" Boat
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5802926
8 October 2015
Examination of Repairs · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5756933
6 October 2015
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5742513
6 October 2015
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5776947
2 September 2015
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5726548
23 October 2014
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5011564
7 October 2014
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5000637
28 August 2014
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4967943
4 August 2014
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4943534
27 May 2014
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4871889
31 July 2012
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4398243
19 June 2012
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4357243
15 June 2012
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4345471
15 June 2012
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4348179
27 May 2012
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4345477
22 May 2012
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4319040
16 May 2012
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4315058
10 January 2012
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4219577
15 August 2011
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4143200
12 August 2011
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4118519
22 July 2011
Examination of Repairs · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4090837
22 July 2011
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4094077
1 October 2008
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3349298
30 September 2008
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3341341
7 May 2007
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2948598
7 September 2006
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2772853
3 August 2006
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2769456
22 September 2005
Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2498856
23 September 2004
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2203179
26 September 2003
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1918905
25 June 2002
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1635960
7 May 2002
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1626426
12 June 2001
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1440507
11 May 2001
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1405194
27 September 2000
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1417130
23 June 2000
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1051268
17 May 2000
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1450491
16 June 1999
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1191448
17 May 1999
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1360929
25 November 1998
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 439479
6 November 1998
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 495997
21 July 1998
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 794808
1 June 1998
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1129202
14 May 1998
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1408113
29 July 1997
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1116876
16 July 1997
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1118233
17 May 1996
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1083142
7 December 1995
Administrative
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1185725
14 November 1995
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 752950
24 October 1995
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 21430
24 October 1995
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 190365
20 September 1995
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1186845
5 July 1995
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1192563
9 June 1995
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 877508
18 May 1995
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 914973
19 May 1994
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 861269
27 October 1993
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 831958
19 May 1993
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 826688
19 May 1992
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 946990
24 April 1991
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1226434
1 May 1990
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1211485
4 May 1989
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1195937
18 April 1989
Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 890833
22 August 1988
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1345559
15 August 1988
Administrative
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1198562
25 July 1988
Drydock Extension
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1036212
4 April 1988
Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1343223
8 April 1987
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1328539
31 October 1986
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1320053
23 October 1986
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1323455
6 May 1986
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1299207
25 March 1985
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1287966
Deficiency record · 183
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 July 2023
Resolved
Generator side of genset is dirty, creating a fire hazard, must be cleaned.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 August 2022
Resolved
#4 void bilge alarm inoperative.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 August 2022
Resolved
E/R wire runs need to be properly routed through WTB's &/or properly terminated/removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 August 2022
Resolved
Several PFE brackets are broken, must be replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 30 August 2022
Resolved
All bilges were extremely dirty, causing potential bilge plumbing clogs. All bilges need to be cleaned.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 August 2022
Resolved
Shaft compartment has pitting & wastage in the port side forward bay, outboard of girder.
** closely examine at upcoming phase II steel work project.**
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 August 2022
Resolved
Charts require updating.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 30 August 2022
Resolved
Crew requires hazmat training every 3 years. All 3 crew members have expired training.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 30 September 2020
Resolved
Drain for the steering gear space is leaking into the lazarette. Determine cause and make drain watertight again to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 30 September 2020
Resolved
Window in the passenger cabin is broken. Replace broken window.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 30 September 2020
Resolved
Bow is missing bottom vehicle retention chain. Replace chain.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 30 September 2020
Resolved
Escape hatch from the engine room must be labeled with "EMERGENCY EXIT, KEEP CLEAR" in 2 inch letters.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 30 September 2020
Resolved
Plywood cargo door on port side has reached its service life and is no longer properly securing the access. Replace door.
12 - Dangerous Goods › N/A - No Subsystem › Special requirement
Issued 30 September 2020
Resolved
Failure to ensure that each employee has received required training prior to transporting a hazardous material by vessel.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 March 2020
Resolved
Vessels maindeck and associated structures have cracking and corrosion IWO doubler plate, suspected hull plating wastage in the #4 void and wasted associated structures, temporary repair of fwd fuel tank bulkhead. As agreed upon during Feb-March 2020 damage survey, emergency dry-docking and subsequent repairs, Owner must make vessel available for credit hull exam no later than 31 December 2020. Hull exam and subsequent repairs shall be in accordance with the submitted/approved Naval Architect plans and fuel tank bulkhead crop/renewal at a minimum, and additional repairs as called out by the attending CG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 February 2020
Resolved
Submit repair proposal and effect permanent repairs in accordance with approved proposal to damaged, fractured and wasted structures and main deck IWO forepeak and #2 void (port forward main deck and vent area).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 February 2020
Resolved
Make vessel available for inspection and further assessment of suspected wastage of hull plating and associated structures in #4 void, port forwardmost bay. Submit proposal and effect permanent repairs as applicable if CG Marine Inspector requires.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 April 2018
Resolved
Properly secure lifefloat beacon bracket.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 April 2018
Resolved
Fabricate and install removeable bow railing.
Fire Fighting › Fire Pumps › Pressure
Issued 25 April 2018
Resolved
Make emergency fire pump pressure gauge operational.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 April 2018
Resolved
Remove excess oil/water mixture from engineroom bilge.
Documentation › Markings/Placards › Warning Signs
Issued 25 April 2018
Resolved
Properly label genset with de-rating placard.
Construction/Loadline › Structures › Deck Plating
Issued 18 April 2018
Resolved
Maintain wooden wedge temporary repairs to deck fractures in way for starboard bow, upon which vessel may operate only until the end of day 18APR2018.
Construction/Loadline › Structures › Deck Plating
Issued 18 April 2018
Resolved
Prior to operating on or after 19APR2018, complete temporary repairs to deck and moorings fixtures at starboard bow, to satisfaction of the attending marine inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2017
Resolved
Replace expired items in first-aid kit
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2017
Resolved
Provide protection on hot piping for main engine cooling, as to prevent injury.
Engineering › Bilge Water Management System › Piping
Issued 24 May 2017
Resolved
Demonstrate proper operation of bilge piping from all compartments. Bilge piping components fractured from freezing during winter layup.
Navigation › Piloting/Steering › Magnetic Compass
Issued 24 May 2017
Resolved
Demonstrate proper operation of compass light.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 May 2017
Resolved
Provide reto-reflective marking on ring life buoy.
Fire Fighting › Fire Hydrants › Condition
Issued 24 May 2017
Resolved
Repair leaking fire hydrant valve below ladder on maindeck.
Engineering › Steering Gear System › Rudder Stock
Issued 24 May 2017
Resolved
Make permanent repair to main steering quadrant in way of connection to rudder stock and demonstate proper operation of same.
Fire Fighting › Fire Hoses › Condition
Issued 24 May 2017
Resolved
Starboard main deck fire hose excessively worn, corrected during inspection.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 May 2017
Resolved
Personal electronics and misc gear stowed in windshiedl, distracting master and partially obstructing view from operating station, cleared away and corrected during inspection.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 24 May 2017
Resolved
Mounting bracket bent, inoperable for BI PFE at operating station, corrected during inspection
Fire Fighting › Fire Hoses › Condition
Issued 9 September 2016
Resolved
Replace broken fire hose reel at starboard main deck fire station.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 9 September 2016
Resolved
Repair excessively loose conduit for AC and DC electrical systems in engineroom.
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 9 September 2016
Resolved
Make man-overboard recovery ladder and system safe for use and demonstrate proper function of same.
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 September 2016
Resolved
Provide records of crew training and drills as per 46 CFR 185.420; .520; and .524.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 September 2016
Resolved
Make vessel and crew available to demonstrate satisfactory drills for fire, man-overboard recovery abandon ship scenarios.
Documentation › Certificates/Documents › Stability Letter
Issued 9 September 2016
Resolved
Stability letter and addendum faded and illegible, replaced during inspection.
Lifesaving › Lifefloat › Float Free
Issued 9 September 2016
Resolved
Life float secured with bungee cord, not float free, stowage not adequate to prevent damage, paddles not lashed to the float, all corrected during inspection.
Lifesaving › Lifebuoys › Stowage
Issued 9 September 2016
Resolved
Ring bouy stowed improperly port side of wheelhouse. Lifeline tangled in handrailing, floating light attachment clip corroded. Corrected during inspection.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Securing Means
Issued 9 September 2016
Resolved
Wheeled semi-portable BV Dry Chemical fire extinguisher improperly secured with ratchet strap around high pressure nitrogen cylinder, corrected during inspection.
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 September 2016
Resolved
Fuel shut off valve inoperable by remote means, corrected during inspection.
Stability › Watertight Integrity › General
Issued 9 September 2016
Resolved
Starboard deck hatch to void space forward of engineroom not watertight, broken gasket, corrected during inspection.
Stability › Intact Righting Energy › General
Issued 23 August 2016
Resolved
Demonstrate vessel stability meets 46 CFR 178.310, meanwhile carry not more than 75 long tons deck cargo and comply with existing stability letter.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 6 October 2015
Resolved
A head gasket on the main engine failed causing a high temperature reading on the engine causing the engine to be shut down.
Construction/Loadline › Hull › Longitudinal Frame
Issued 2 September 2015
Resolved
Wasted longitudinal and intior bulk head in way of third manhole on starboard side. Crop and renew. 46CFR177.100
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 September 2015
Resolved
Replace expired items in first aid kit.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 August 2014
Resolved
Properly install float light bracket for Life Float.
Lifesaving › Lifefloat › Serviceable
Issued 4 August 2014
Resolved
Replace deteriorated lines and retroreflective markings on life float.
Stability › Watertight Integrity › General
Issued 4 August 2014
Resolved
Install safety chains on all deck hatches to prevent loss while underway.
Stability › Watertight Integrity › General
Issued 4 August 2014
Resolved
Make hatches watertight in main deck accesses to voids number 1, 2, 3, and 4.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 August 2014
Resolved
Install permanent railing across stern of main deck, prior to allowing passengers afoot on main deck.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2014
Resolved
Provide metallic support and chafe protection for wiring in engineroom.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2014
Resolved
Makeshift portable cables to provide temporary 120VAC shoreside power to engineroom space heater, draped throughout engineroom and main deck at portside of deck house. Corrected during inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2014
Resolved
120VAC power supply wiring to cabin heater draped loosely in engineroom and main deck. Corrected during inspection.
Engineering › Bilge Water Management System › Valve
Issued 4 August 2014
Resolved
Remote operating mechanism for forepeak bilge suction was difficult to operate, lubricated and corrected during inspection.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 4 August 2014
Resolved
Portable B-II CO2 PFE for engineroom not in proper location at engineroom access, standing loose loose and unsupported on deck, moved to existing bracket in engineroom access area. Corrected during inspection.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 4 August 2014
Resolved
One Dry Chem B-II PFE not on board as required on COI for main deck location. Proper size and approved bracket were provided and installed in an acceptable location during inspection.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Securing Means
Issued 4 August 2014
Resolved
Wheeled Dry Chem B-V unit secured to port bulwark on main deck using loose lightweight chain draped around the high pressure cylinder head, posing sever safety hazard, corrected immediately by removing chain and installing ratcheting strap around wheel/chassis.
Personnel › Training › Familiarization Training
Issued 4 August 2014
Resolved
Deckhand was inadequately outfitted and poorly trained for safe recovery of a person from the water. Deckhand improperly aligned piping system for main fire pump, immediately received training from owner rep in attendance. Master and deckhand need to practice and demonstrate proficiency. Sighted minimal documenation of training. Corrected during inspection.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 August 2014
Resolved
PFD storage compartment on main deck not marked, had been painted over, corrected during inspection.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 August 2014
Resolved
Crew acted unsafely in ineffectively during first attempt at man-ovebaord recovery, passed second drill.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 August 2014
Resolved
Only a superceded and invalid version of COI was posted, owner found and posted proper COI during inspection.
Documentation › Certificates/Documents › FCC SSL
Issued 4 August 2014
Resolved
The posted FCC Ship Station LIcense was expired, owner replaced with a current and valid license during inspection.
Engineering › Steering Gear System › Linkage
Issued 4 August 2014
Resolved
Emergency steering tackle ineffective, owner provided a working replacement block/tackle arrangement, crew demonstrated proper emergency steering operation during drill.
Engineering › Lubricating Oil Service System › Tube
Issued 4 August 2014
Resolved
Pressurized tubing for reduction gear lube and main engine lube oil gages unsupported, posing risk of failure, entanglement and oil-spray fire hazards. Corrected during inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 August 2014
Resolved
First aid kit contents incomplete and expired, corrected during inspection.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 4 August 2014
Resolved
Main deck trashcan combustible, replaced during inspection with metal trashcan.
Engineering › Gas Turbine (propulsion/auxiliary-electric) › Seal
Issued 15 June 2012
Resolved
Prior to operating, demonstrate proper operation of generator.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 22 May 2012
Resolved
Prior to operating vessel, demonstrate proper operation of the propulsion system.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Service
Issued 19 January 2012
Resolved
Provide servicing report showing the dry chemical tank on semi-portable wheeled dry chemical extinguisher has been hydrostatically tested as per NFPA10, prior to carrying dangerous cargoes per 49 CFR 172 and 176.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 17 January 2012
Resolved
Provide report showing CO2 system in engineroom is properly configured and the pull cable functions properly.
See activity 4219577 narrative for problem description and temporary repair.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 17 January 2012
Resolved
Label CO2 pull station on main deck to be distinct and separate from fuel oil shut off instructions.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 17 January 2012
Resolved
Install flame screen in fuel oil tank vent.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 January 2012
Resolved
Ship Service Generator instrument panel improperly maintained, frequency meter inoperable, open holes in panel cover, power indicator lamp adrift, panel cover adrift missing hold-down screws. worklist item, corrected during inspection
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 January 2012
Resolved
Electrical distribution wiring improperly supported with plastic ties, mostly within engineroom, worklist item, corrected during inspection
Electrical › Lighting (service) › Lighting Fixture
Issued 10 January 2012
Resolved
120VAC lighting fixture above Main Diesel Engine adrift, missing cover and screws, worklist item corrected during inspection
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Air Cleaner
Issued 10 January 2012
Resolved
On SSG prime mover, improperly installed intake air cleaner falls off easily, corrected during inspection.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Bearing
Issued 10 January 2012
Resolved
On SSG prime mover, alternator and drive belt excessively loose, prime for failure, worklist item corrected during inspection.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Bearing
Issued 10 January 2012
Resolved
On SSG prime mover, coolant circulating pump ready to fail due to worn bearing, owner replaced during inspection.
Engineering › Fuel Oil Service System › Filter
Issued 10 January 2012
Resolved
On main engine fuel oil filter, sediment drain cock was not fitted with a threaded plug, worklist item, corrected during inspection.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 10 January 2012
Resolved
On fixed CO2 system in engineroom, discharge nozzles and piping were excessively loose in brackets so that the discharge nozzle was out of position and ineffective, worklist item, corrected during inspection.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 10 January 2012
Resolved
Conduct emergency training for firefighting, man overboard and abandon ship and provide documentation, worklist item, corrected during inspection.
Lifesaving › Buoyant Apparatus › Painter
Issued 10 January 2012
Resolved
Sea painter deteriorated, will not last another year, worklist item, corrected during inspection.
Lifesaving › Lifebuoys › Serviceable
Issued 10 January 2012
Resolved
Lanyard for float light on ring lifebuoy (by wheelhouse) deteriorated and improperl;y installed, worklist item, corrected during inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 January 2012
Resolved
First aid kit missing required items and has expired medicines, worklist item, corrected during inspection.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 January 2012
Resolved
Portable railing at bow and stern loading areas inadequately fastened and ineffective, worklist item corrected during inspection.
Personnel › Training › Fire Fighting Basic
Issued 10 January 2012
Resolved
Master and Deckhand were inadequately trained for manoverboard, fire and abandon ship procedures and and subsequently failed basic drills. Worklist item, corrected during inspection.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 10 January 2012
Resolved
On SSG, integral coolant fitting/hose not double-clamped, corrected during inspection.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 August 2011
Resolved
Repair holed and corroded shaft log in two aft void spaces. Temporary repairs authorized. No cargo or passengers until permanent repairs are made.
Construction/Loadline › Structures › Superstructure
Issued 30 September 2008
Resolved
Port windshield in pilot house is cracked in line of sight and my be weakened structurally. Replace with new windshield.
Lifesaving › Lifefloat › Lifeline
Issued 30 September 2008
Resolved
Lifeline on the 22 person LF is wasted and deteriorated through in multiple places. Replace prior to carrying more than 32 persons.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 30 September 2008
Resolved
Maintain lifesaving equipment inspections and crew drills in vessel log.
Engineering › Bilge Water Management System › Piping
Issued 30 September 2008
Resolved
Bilge lines in #3 hold are corroded through. Replace wasted piping with new back to good metal.
Construction/Loadline › Hull › Transverse Frame
Issued 30 September 2008
Resolved
Transverse frames 3 and 4 in forepeak are wasted through on the port and stbd side of the keel. transverse frame 2 is wasted on the stbd side only. Crop and renew frames 3 and 4 to port and stbd vertical frames and frame 2 from keel to stbd vertical frame.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 30 September 2008
Resolved
Provide proper navigation publications.
Engineering › Bilge Water Management System › Hose
Issued 7 May 2007
Resolved
Remove excess oil/water from engine room bilge.
Engineering › Bilge Water Management System › Valve
Issued 7 May 2007
Resolved
Replace/renew valve in #3 void bilge piping.
Construction/Loadline › Hull › Weld
Issued 7 May 2007
Resolved
Repair fractured welds in #1 and #2 voids.
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 7 May 2007
Resolved
Install chaffing gear on generator fuel line.
Engineering › Diesel Engine (propulsion-direct drive) › Air-flex Clutch
Issued 7 May 2007
Resolved
Replace/renew aft side MDE worn belt.
Lifesaving › Lifebuoys › Serviceable
Issued 7 May 2007
Resolved
Stencil O/B ring life buoy and replace aft ring life buoy on pilot house.
Lifesaving › Lifefloat › Float-free Link
Issued 7 May 2007
Resolved
Replace soon to expire hydro static release on life float.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 7 September 2006
Resolved
Cutlass bearing worn beyond limits, requires replacement.
Engineering › Steering Gear System › Rudder Bearing
Issued 7 September 2006
Resolved
Rudder appears to have dropped 1" and the rudder bearing needs replaced. This is causing the rudder quadrant to be uneven. Entire system needs removed and inspected and replaced as necessary.
Engineering › Steering Gear System › Linkage
Issued 7 September 2006
Resolved
Wire rope for steering system needs replaced at the quadrant. Almost 50% chaffed through.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 September 2006
Resolved
Possible leak in the bottom of the fuel tank bulkhead through to the # 4 void. UT shots required in the vicinity to locate leak. Resolve leak and crop out and renew if necessary.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 September 2006
Resolved
Several small cracked welds approximately 1" in length in the #1 and #2 voids. Repair and replace welds.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2006
Resolved
Test suspected area of hull for excessive wastage in #2 void.
Construction/Loadline › Structures › Ventilators
Issued 3 August 2006
Resolved
Repair to original wasted section of plating at base of ventilation shaft for #2 void, port side I.A.W. 46 CFR 177.300.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 3 August 2006
Resolved
Provide external access control for operation of vessel's fixed CO2 system I.A.W. 46 CFR 181.410(b).
Lifesaving › Lifebuoys › Serviceable
Issued 22 September 2005
Resolved
REPLACE TWO RING BUOYS PORTSIDE PILOT HOUSE.
Stability › Watertight Integrity › General
Issued 22 September 2005
Resolved
REPAIR WELD FRACTURES #2 COMPARTMENT PORTSIDE.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 22 September 2005
Resolved
REPLACE COOLANT HOSE ON FWD SIDE, UPPER OFF OF COOLAND TANK.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 22 September 2005
Resolved
REPAIR EMERGENCY ENGINE STOP CABLE TO GOVERNOR HOUSING.
Engineering › Freshwater System (intermediary cooling) › Fitting
Issued 22 September 2005
Resolved
REPLACE GENERATOR THERMOSTAT HOUSING GASKET.
Fire Fighting › Fire Pumps › Pressure
Issued 22 September 2005
Resolved
REPAIR MAIN DIESEL ENGINE DRIVEN FIRE PUMP.
Stability › Watertight Integrity › General
Issued 22 September 2005
Resolved
RPAIR WELD FRACTURES #3 COMPARTMENT ON STBD SIDE LOWER UNDER RUB RAIL.
Engineering › Steering Gear System › Rudder
Issued 22 September 2005
Resolved
REPAIR/ INSTALL WELD ON RUDDER POST PORT SIDE OF AFTER STEERING.
Construction/Loadline › Hull › Weld
Issued 23 September 2004
Resolved
Repair weld fractures FWD void 7 total.
Construction/Loadline › Penetrations › Weld
Issued 23 September 2004
Resolved
Repair plug welds main deck.
Engineering › Bilge Water Management System › Not Operational
Issued 23 September 2004
Resolved
Remove oil and rags from engine room bilges.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 23 September 2004
Resolved
Re-route steering cable after steering compartment.
Lifesaving › Launching Appliances › Release Mechanism
Issued 23 September 2004
Resolved
Replace retaining strap on lifefloat pilothouse.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 23 September 2004
Resolved
At servicing time re-engineer fixed fire fighting system, cable and controls. per 46CFR181.410.
Electrical › Electrical Distribution System (service)
Issued 26 September 2003
Resolved
Remount electrical light, wires aft engine room.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 September 2003
Resolved
Repair CO2 release engine room.
Fire Fighting › Fire Pumps
Issued 26 September 2003
Resolved
Repair engine driven fire pump.
Construction/Loadline › Structures › Rake
Issued 26 September 2003
Resolved
Repair weld fractures fwd void port & stbd sides.
Lifesaving › Buoyant Apparatus
Issued 7 May 2002
Resolved
Replace 16 person buoyant apparatus with life float of equal capacity prior to the compliance date. Vessel is limited to carrying not more than 44 total persons unitl the life float is installed.
Construction/Loadline › Hull
Issued 7 May 2002
Resolved
Repair fractures in main deck in way of the rub rail, starboard side forward, prior to the compliance date.
Engineering › Bilge Water Management System
Issued 7 May 2002
Resolved
Replace rusted u-joint connection for the forepeak remote reach rod prior to the compliance date.
Lifesaving › Lifebuoys
Issued 7 May 2002
Resolved
Provide a clip for the bridge waterlight ring buoy prior to the compliance date.
Engineering
Issued 12 June 2001
Resolved
REPAIR AND DEMONSTRATE OPERATION OF MAIN ENGINE TACHOMETER, OIL PRESSURE AND TEMPERATURE GAUGES IN THE PILOTHOUSE BEFORE THE COMPLIANCE DATE.
Fire Fighting
Issued 12 June 2001
Resolved
PROVIDE SERVICING REPORT FOR FIXED FIRE EXTINGUISHING EQUIPMENT, PRIOR TO THE COMPLIANCE DATE.
Engineering
Issued 12 June 2001
Resolved
MAIN ENGINE FOUNDATION BOLTS EXCESSIVELY LOOSE, CORRECTED DURING INSPECTION_x001C_
Fire Fighting
Issued 12 June 2001
Resolved
CO2 CYLINDER EXCESSIVELTY LOOSE, CAN ROTATE AS TO SAUSE ACCIDENTAL RELEASE,CORRECTED DURING INSPECTION.
Fire Fighting
Issued 12 June 2001
Resolved
ONE BII PORT CO2 FIRE EXTINGUISHER IS PAST DUE FOR HYDROSTATIC TESTING, REPLACED DURING INSPECTION.
Lifesaving
Issued 12 June 2001
Resolved
FLOAT LIGHT FOR RING BUOY INOPERABLE, CORRECTED DURING INSPECTION.
Navigation
Issued 12 June 2001
Resolved
RUDDER STOCK EXCESSIVELY LOOSE AND WORN IN STEERING QUADRANT, WELDMENT IS ALSO CRACKED, CORRECTED DURING INSPECTION.
Construction/Loadline
Issued 12 June 2001
Resolved
REPAIR AND DEMONSTRATE OPERATION OF BILGE ALARM IN RUDDER COMARTMENT BEFORETHE COMPLIANCE DATE.
Navigation
Issued 27 September 2000
Resolved
4 OF 6 COUPLING BOLTS MISSING, CORRECTED DURING INSPECTION
Construction/Loadline
Issued 27 September 2000
Resolved
SEA VALVE FOR ELECTRIC FIRE PUMP HAD A DAMAGED GATE DISK, ENTIRE VALVE RENEWED IN KIND.
Deck/Cargo
Issued 27 September 2000
Resolved
ANCHOR CHAIN FOULED ABOUT THE INTERNAL STRUCTURES IN FOREPEAK, CORRECTED DURING INSPECITON.
Fire Fighting
Issued 17 May 2000
Resolved
CONDUCT CREW TRAINING AND PROVE THEIR PROFICIENCY IN MAN-OVERBOARD AND_x001C_ FIRE DRILLS IN THE PRESENCE OF A MARINE INSPECTOR BEFORE THE COMPLIANCE DATE.
Electrical
Issued 17 May 1999
Resolved
CLEAN BATTERY BOXES AND REPAIR LEAD LINING, PROVIDE SPACE BETWEEN BATTERY TERMINALS AND BULKHEAD PRIOR TO THE COMPLIANCE DATE.
Construction/Loadline
Issued 17 May 1999
Resolved
REPAIR HATCH COVER LEADING INTO THE # 5 COMPARTMENT PRIOR TO THE COMPLIANCEDATE.
Fire Fighting
Issued 17 May 1999
Resolved
REPAIR FIREPUMP GAUGE PRIOR TO THE COMPLIANCE DATE.
Electrical
Issued 17 May 1999
Resolved
WIRE MDE ALTERNATOR AS REQUIRED BY 46 CFR 183.340 PRIOR TO THE COMPLIANCE DATE.
Navigation
Issued 17 May 1999
Resolved
REPAIR STEERING CABLE LOCATED AT ENGINE ROOM TRUCK PRIOR TO THE COMPLIANCE DATE.
Construction/Loadline
Issued 17 May 1999
Resolved
CLEAN ALL COMPARTMENTS OF DEBRIS AND ROCKS, MAKE READY FOR INSPECTION PRIORTO THE COMPLIANCE DATE.
Construction/Loadline
Issued 17 May 1999
Resolved
PROVE OPERATION OF BILGE PUMP SUCTION IN # 4 COMPARTMENT PRIOR TO CARRYING PASSENGERS AND PRIOR TO THE COMPLIANCE DATE.
Lifesaving
Issued 17 May 1999
Resolved
INSTALL PROPER WEAKLINK FOR BUOYANT APPARATUS PRIOR TO THE COMPLIANCE DATE.
Navigation
Issued 17 May 1999
Resolved
PROVE PROPER OPERATION OF STARBOARD NAVIGATION RUNNING LIGHT PRIOR TO CARRYING PASSENGERS AND PRIOR TO THE COMPLIANCE DATE.
Construction/Loadline
Issued 17 May 1999
Resolved
REPLACE BILGE SUCTION STRAINER IN # 1 COMPARTMENT PRIOR TO THE COMPLIANCE DATE.
Fire Fighting
Issued 17 May 1999
Resolved
MARK FIRE AX WITH VESSEL NAME PRIOR TO THE COMPLIANCE DATE.
Navigation
Issued 17 May 1999
Resolved
PROVIDE COPY OF INLAND NAVIGATION RULES PRIOR TO CARRYING PASSENGERS AND PRIOR TO THE COMPLIANCE DATE.
Fire Fighting
Issued 14 May 1998
Resolved
Provide copy of Northern Fire Safety service report to Marine Inspector. Two portable fire extinguisher cylinders will require hydrostatic testing by 30MAY98.
Navigation
Issued 14 May 1998
Resolved
Lubricate cables and sheves on steering system.
Lifesaving
Issued 14 May 1998
Resolved
Renew vessel name on Ring Lifebuoy.
Engineering
Issued 16 July 1997
Resolved
Modify emergency fuel shut-off valve so that valve remains shut after closing from remote station.
Lifesaving
Issued 16 July 1997
Resolved
Attach Coast Guard approved weak link between buoyant apparatus painter andship's structure.
Lifesaving
Issued 18 May 1995
Resolved
Re-stencil PFD storage locker outside bridge, and capacity on buoyant apparatus.
Construction/Loadline
Issued 18 May 1995
Resolved
Crop and renew upset bottom shell plate in forepeak, in way of 1st frame space, no later than next scheduled drydock exam. Submit repair proposal to attending marine inspector prior to starting work.
Lifesaving
Issued 18 May 1995
Resolved
Replace lifelines on buoyant apparatus and bridge ring buoys.
Fire Fighting
Issued 18 May 1995
Resolved
Re-charge engine room fixed CO2 system. Carry 2 extra portable B-II fire extinguishers and no passengers until corrected.
Construction/Loadline
Issued 18 May 1995
Resolved
Repair hull internals as indicated on worklist numbers 1a through 1c.
Deck/Cargo
Issued 24 April 1991
Resolved
Adequately secure end of anchor chain to vessel structure._x001C_ (Chain is presently secured to stanchion with an overhand knot.)
Fire Fighting
Issued 24 April 1991
Resolved
Replace temporary fire pump with a pump capable of supplying the required_x001C_ 1 1/2 inch fire lines. (Present temporary pump has a 1 inch non-UL hose_x001C_ and no nozzle.)
Electrical
Issued 24 April 1991
Resolved
Provide battery cover for battery: aft engineroom bulkhead.
Fire Fighting
Issued 24 April 1991
Resolved
Provide suitable hand fire and bilge pump.
Engineering
Issued 24 April 1991
Resolved
Replace deteriorated rubber connection hoses on main engine.
Navigation
Issued 24 April 1991
Resolved
Provide adequate search light.
Fire Fighting
Issued 24 April 1991
Resolved
Install new drive motor and demonstrate operation of fire pump.
Fire Fighting
Issued 24 April 1991
Resolved
Provide approved 1 1/2 inch all purpose combination fire nozzle for_x001C_ compliance with dangerous cargo regulations.
Fire Fighting
Issued 24 April 1991
Resolved
Provide evidence or annual servicing of fixed C0-2 extinguishing system_x001C_ and BV fire extinguisher.
Lifesaving
Issued 24 April 1991
Resolved
Provide and install float light for life ring.
Lifesaving
Issued 24 April 1991
Resolved
Stencil PFD stowage box on port bridge wing with number and size of_x001C_ PFD's inside.
Construction/Loadline
Issued 24 April 1991
Resolved
Weld fractures in hatch coamings, number 2 and number 3 compartments.
Construction/Loadline
Issued 24 April 1991
Resolved
Repair fractures in connection of transverse deck beams and deck in_x001C_ number 2 compartment.
Electrical
Issued 24 April 1991
Resolved
Repair or remove broken deck light, in overhead under bridge wing._x001C_ (Globe and bulb broken off, exposed remnants of bulb filament protruding.)
Casualty record · 7
22 July 2011Routine · role: Involved in a Marine Casualty · activity 4094077
12 August 2011Routine · role: Involved in a Marine Casualty · activity 4118519
16 May 2012Routine · role: Involved in a Marine Casualty · activity 4315058
15 June 2012Routine · role: Involved in a Marine Casualty · activity 4348179
15 August 2012Routine · role: Involved in a Marine Casualty · activity 4416626
27 May 2014Routine · role: Involved in a Marine Casualty · activity 4871889
6 October 2015Routine · role: Involved in a Marine Casualty · activity 5742513
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
CORSAIR (2011–2015). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.