W.S. WOODFILL

W.S. WOODFILL is a 1955 passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 1985, most recently in May 2026, along with 183 deficiencies and 7 casualty investigations between 2011 and 2015.

Records from 1985 to 2026. Most recent: inspection, 8 May 2026.

Built
1955
Last inspected
8 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI5217
Flag
UNITED STATES
367706320
Maury page id
psix-43050

Inspections, by type

…with no type recorded17
Years with a record 38 calendar years (1985–2026)
The 94 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)91.8 ft × 33.1 ft × 8.1 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1955
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMACKINAC ISLAND, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
98 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI5217MMSI 367706320 · active · compulsorily equipped · granted 8 January 2026, expires 10 December 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 94

8 May 2026 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8357937
4 March 2026 Inclining Experiment
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8319061
27 June 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7966071
11 July 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7780472
3 January 2023 Examination of Repairs · Damage Survey · Deadweight Survey · Plan Review "T" Boat
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7648412
30 August 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7582629
1 December 2021 Drydock Extension · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7369005
10 December 2020 Deadweight Survey · Administrative Inspection · Examination of Repairs · Plan Review "T" Boat · COI Inspection · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7173667
13 October 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7076302
30 September 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7068384
3 February 2020 Examination of Repairs · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6902573
6 May 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6782075
25 April 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6399855
18 April 2018 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6399881
2 November 2017 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6302803
24 May 2017 COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6146807
1 February 2017 Administrative Inspection · Inclining Experiment · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6146671
27 December 2016 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6062676
8 November 2016 Examination of Repairs · Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6049474
14 September 2016 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6000893
9 September 2016 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5996570
12 February 2016 Construction Oversight · Deadweight Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5996583
13 January 2016 Plan Review "T" Boat
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5802926
8 October 2015 Examination of Repairs · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5756933
6 October 2015 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5742513
6 October 2015 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5776947
2 September 2015 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5726548
23 October 2014 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5011564
7 October 2014 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5000637
28 August 2014 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4967943
4 August 2014 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4943534
27 May 2014 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4871889
31 July 2012 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4398243
19 June 2012 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4357243
15 June 2012 Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4345471
15 June 2012 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4348179
27 May 2012 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4345477
22 May 2012 Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4319040
16 May 2012 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4315058
10 January 2012 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4219577
15 August 2011 Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4143200
12 August 2011 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4118519
22 July 2011 Examination of Repairs · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4090837
22 July 2011 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4094077
1 October 2008 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3349298
30 September 2008 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3341341
7 May 2007 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2948598
7 September 2006 Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2772853
3 August 2006 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2769456
22 September 2005 Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2498856
23 September 2004 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2203179
26 September 2003 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1918905
25 June 2002 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1635960
7 May 2002 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1626426
12 June 2001 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1440507
11 May 2001 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1405194
27 September 2000 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1417130
23 June 2000 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1051268
17 May 2000 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1450491
16 June 1999 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1191448
17 May 1999 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1360929
25 November 1998 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 439479
6 November 1998 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 495997
21 July 1998 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 794808
1 June 1998 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1129202
14 May 1998 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1408113
29 July 1997 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1116876
16 July 1997 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1118233
17 May 1996 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1083142
7 December 1995 Administrative
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1185725
14 November 1995 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 752950
24 October 1995 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 21430
24 October 1995 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 190365
20 September 1995 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1186845
5 July 1995 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1192563
9 June 1995 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 877508
18 May 1995 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 914973
19 May 1994 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 861269
27 October 1993 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 831958
19 May 1993 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 826688
19 May 1992 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 946990
24 April 1991 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1226434
1 May 1990 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1211485
4 May 1989 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1195937
18 April 1989 Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 890833
22 August 1988 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1345559
15 August 1988 Administrative
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1198562
25 July 1988 Drydock Extension
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1036212
4 April 1988 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1343223
8 April 1987 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1328539
31 October 1986 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1320053
23 October 1986 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1323455
6 May 1986 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1299207
25 March 1985 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1287966

Deficiency record · 183

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 July 2023 Resolved
Generator side of genset is dirty, creating a fire hazard, must be cleaned.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 17 July 2023
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 August 2022 Resolved
#4 void bilge alarm inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2022
Resolved 30 August 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 August 2022 Resolved
E/R wire runs need to be properly routed through WTB's &/or properly terminated/removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2022
Resolved 30 August 2022
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 August 2022 Resolved
Several PFE brackets are broken, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2022
Resolved 1 September 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 30 August 2022 Resolved
All bilges were extremely dirty, causing potential bilge plumbing clogs. All bilges need to be cleaned.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2022
Resolved 4 October 2022
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 August 2022 Resolved
Shaft compartment has pitting & wastage in the port side forward bay, outboard of girder. ** closely examine at upcoming phase II steel work project.**
Action required: 705 - Other - as specified
Due 31 December 2022
Resolved 13 March 2025
Resolution: wasted are of hull plate & assoc. structures have been cropped & renewed. NDT witnessed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 August 2022 Resolved
Charts require updating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2022
Resolved 4 October 2022
Resolution: corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 30 August 2022 Resolved
Crew requires hazmat training every 3 years. All 3 crew members have expired training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2022
Resolved 1 September 2022
Resolution: completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 30 September 2020 Resolved
Drain for the steering gear space is leaking into the lazarette. Determine cause and make drain watertight again to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 7 October 2020
Resolution: Welded closed. Wated drains out of the stbd drain now. Will need to be fixed during drydock.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 30 September 2020 Resolved
Window in the passenger cabin is broken. Replace broken window.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 3 September 2021
Resolution: Received photo from vessels primary Master depicting window satisfactory replacement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 30 September 2020 Resolved
Bow is missing bottom vehicle retention chain. Replace chain.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 7 October 2020
Resolution: Chain replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 30 September 2020 Resolved
Escape hatch from the engine room must be labeled with "EMERGENCY EXIT, KEEP CLEAR" in 2 inch letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 13 October 2020
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 30 September 2020 Resolved
Plywood cargo door on port side has reached its service life and is no longer properly securing the access. Replace door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 7 October 2020
Resolution: replaced.
12 - Dangerous Goods › N/A - No Subsystem › Special requirement
Issued 30 September 2020 Resolved
Failure to ensure that each employee has received required training prior to transporting a hazardous material by vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 26 July 2021
Resolution: corrected, all employees have received the required training.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 March 2020 Resolved
Vessels maindeck and associated structures have cracking and corrosion IWO doubler plate, suspected hull plating wastage in the #4 void and wasted associated structures, temporary repair of fwd fuel tank bulkhead. As agreed upon during Feb-March 2020 damage survey, emergency dry-docking and subsequent repairs, Owner must make vessel available for credit hull exam no later than 31 December 2020. Hull exam and subsequent repairs shall be in accordance with the submitted/approved Naval Architect plans and fuel tank bulkhead crop/renewal at a minimum, and additional repairs as called out by the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 19 August 2021
Resolution: Resolved. Re-issued for main deck and above requirements.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 February 2020 Resolved
Submit repair proposal and effect permanent repairs in accordance with approved proposal to damaged, fractured and wasted structures and main deck IWO forepeak and #2 void (port forward main deck and vent area).
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2020
Resolved 13 March 2020
Resolution: repaired, see activity narrative.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 February 2020 Resolved
Make vessel available for inspection and further assessment of suspected wastage of hull plating and associated structures in #4 void, port forwardmost bay. Submit proposal and effect permanent repairs as applicable if CG Marine Inspector requires.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2020
Resolved 13 March 2020
Resolution: repaired, see activity narrartive.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 April 2018 Resolved
Properly secure lifefloat beacon bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 2 May 2018
Resolution: secured.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 April 2018 Resolved
Fabricate and install removeable bow railing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2018
Resolved 16 May 2018
Resolution: Received photo of fabricated railings (chain). Inspector to visually inpsect in person this Friday.
Fire Fighting › Fire Pumps › Pressure
Issued 25 April 2018 Resolved
Make emergency fire pump pressure gauge operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 2 May 2018
Resolution: replaced gauge, ops check good.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 April 2018 Resolved
Remove excess oil/water mixture from engineroom bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 2 May 2018
Resolution: corrected.
Documentation › Markings/Placards › Warning Signs
Issued 25 April 2018 Resolved
Properly label genset with de-rating placard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 2 May 2018
Resolution: completed.
Construction/Loadline › Structures › Deck Plating
Issued 18 April 2018 Resolved
Maintain wooden wedge temporary repairs to deck fractures in way for starboard bow, upon which vessel may operate only until the end of day 18APR2018.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2018
Resolved 19 April 2018
Construction/Loadline › Structures › Deck Plating
Issued 18 April 2018 Resolved
Prior to operating on or after 19APR2018, complete temporary repairs to deck and moorings fixtures at starboard bow, to satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2018
Resolved 19 April 2018
Resolution: Attended vessel 19APR, repairs to be further examined at upcoming annual inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2017 Resolved
Replace expired items in first-aid kit
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 26 May 2017
Resolution: replaced
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2017 Resolved
Provide protection on hot piping for main engine cooling, as to prevent injury.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 26 May 2017
Resolution: installed
Engineering › Bilge Water Management System › Piping
Issued 24 May 2017 Resolved
Demonstrate proper operation of bilge piping from all compartments. Bilge piping components fractured from freezing during winter layup.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 26 May 2017
Resolution: corrected and tested, all sat
Navigation › Piloting/Steering › Magnetic Compass
Issued 24 May 2017 Resolved
Demonstrate proper operation of compass light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 26 May 2017
Resolution: corrected
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 May 2017 Resolved
Provide reto-reflective marking on ring life buoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 26 May 2017
Resolution: corrected
Fire Fighting › Fire Hydrants › Condition
Issued 24 May 2017 Resolved
Repair leaking fire hydrant valve below ladder on maindeck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 26 May 2017
Resolution: repaired and tested, all sat
Engineering › Steering Gear System › Rudder Stock
Issued 24 May 2017 Resolved
Make permanent repair to main steering quadrant in way of connection to rudder stock and demonstate proper operation of same.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 26 May 2017
Resolution: repaired and tested, all sat
Fire Fighting › Fire Hoses › Condition
Issued 24 May 2017 Resolved
Starboard main deck fire hose excessively worn, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 24 May 2017
Resolved 24 May 2017
Resolution: corrected during inspection
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 May 2017 Resolved
Personal electronics and misc gear stowed in windshiedl, distracting master and partially obstructing view from operating station, cleared away and corrected during inspection.
Condition: Improper Installation
Due 24 May 2017
Resolved 24 May 2017
Resolution: corrected during inspection.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 24 May 2017 Resolved
Mounting bracket bent, inoperable for BI PFE at operating station, corrected during inspection
Condition: Improper/Lack of Maintenance
Due 24 May 2017
Resolved 24 May 2017
Resolution: corrected during inspection
Fire Fighting › Fire Hoses › Condition
Issued 9 September 2016 Resolved
Replace broken fire hose reel at starboard main deck fire station.
Condition: Improper/Lack of Maintenance
Due 16 September 2016
Resolved 14 September 2016
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 9 September 2016 Resolved
Repair excessively loose conduit for AC and DC electrical systems in engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 14 September 2016
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 9 September 2016 Resolved
Make man-overboard recovery ladder and system safe for use and demonstrate proper function of same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 14 September 2016
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 September 2016 Resolved
Provide records of crew training and drills as per 46 CFR 185.420; .520; and .524.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 14 September 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 September 2016 Resolved
Make vessel and crew available to demonstrate satisfactory drills for fire, man-overboard recovery abandon ship scenarios.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 14 September 2016
Documentation › Certificates/Documents › Stability Letter
Issued 9 September 2016 Resolved
Stability letter and addendum faded and illegible, replaced during inspection.
Condition: Improper/Lack of Maintenance
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection.
Lifesaving › Lifefloat › Float Free
Issued 9 September 2016 Resolved
Life float secured with bungee cord, not float free, stowage not adequate to prevent damage, paddles not lashed to the float, all corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection
Lifesaving › Lifebuoys › Stowage
Issued 9 September 2016 Resolved
Ring bouy stowed improperly port side of wheelhouse. Lifeline tangled in handrailing, floating light attachment clip corroded. Corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Securing Means
Issued 9 September 2016 Resolved
Wheeled semi-portable BV Dry Chemical fire extinguisher improperly secured with ratchet strap around high pressure nitrogen cylinder, corrected during inspection.
Condition: Improper Installation
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 September 2016 Resolved
Fuel shut off valve inoperable by remote means, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection.
Stability › Watertight Integrity › General
Issued 9 September 2016 Resolved
Starboard deck hatch to void space forward of engineroom not watertight, broken gasket, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 9 September 2016
Resolved 9 September 2016
Resolution: corrected during inspection.
Stability › Intact Righting Energy › General
Issued 23 August 2016 Resolved
Demonstrate vessel stability meets 46 CFR 178.310, meanwhile carry not more than 75 long tons deck cargo and comply with existing stability letter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 13 March 2017
Resolution: Sighted new stability ltr issued by the MSC.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 6 October 2015 Resolved
A head gasket on the main engine failed causing a high temperature reading on the engine causing the engine to be shut down.
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 8 October 2015
Construction/Loadline › Hull › Longitudinal Frame
Issued 2 September 2015 Resolved
Wasted longitudinal and intior bulk head in way of third manhole on starboard side. Crop and renew. 46CFR177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 24 February 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 September 2015 Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 8 October 2015
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 August 2014 Resolved
Properly install float light bracket for Life Float.
Condition: Improper/Lack of Maintenance
Due 18 August 2014
Resolved 28 August 2014
Lifesaving › Lifefloat › Serviceable
Issued 4 August 2014 Resolved
Replace deteriorated lines and retroreflective markings on life float.
Condition: Improper/Lack of Maintenance
Due 11 September 2014
Resolved 28 August 2014
Resolution: Entire LF replaced in kind.
Stability › Watertight Integrity › General
Issued 4 August 2014 Resolved
Install safety chains on all deck hatches to prevent loss while underway.
Condition: Improper/Lack of Maintenance
Due 18 August 2014
Resolved 28 August 2014
Stability › Watertight Integrity › General
Issued 4 August 2014 Resolved
Make hatches watertight in main deck accesses to voids number 1, 2, 3, and 4.
Condition: Improper/Lack of Maintenance
Due 18 August 2014
Resolved 28 August 2014
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 August 2014 Resolved
Install permanent railing across stern of main deck, prior to allowing passengers afoot on main deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2014
Resolved 23 October 2014
Resolution: newly installed railing sighted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2014 Resolved
Provide metallic support and chafe protection for wiring in engineroom.
Condition: Improper/Lack of Maintenance
Due 11 August 2014
Resolved 28 August 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2014 Resolved
Makeshift portable cables to provide temporary 120VAC shoreside power to engineroom space heater, draped throughout engineroom and main deck at portside of deck house. Corrected during inspection.
Condition: Improper Installation
Due 11 August 2014
Resolved 11 August 2014
Resolution: Cables are coiled, safely stowed and tagged in engineroom, to be used only when vessel is out of service in winter layup.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2014 Resolved
120VAC power supply wiring to cabin heater draped loosely in engineroom and main deck. Corrected during inspection.
Condition: Improper Installation
Due 11 August 2014
Resolved 11 August 2014
Engineering › Bilge Water Management System › Valve
Issued 4 August 2014 Resolved
Remote operating mechanism for forepeak bilge suction was difficult to operate, lubricated and corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 11 August 2014
Resolved 11 August 2014
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 4 August 2014 Resolved
Portable B-II CO2 PFE for engineroom not in proper location at engineroom access, standing loose loose and unsupported on deck, moved to existing bracket in engineroom access area. Corrected during inspection.
Condition: Improper Installation
Due 7 August 2014
Resolved 7 August 2014
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 4 August 2014 Resolved
One Dry Chem B-II PFE not on board as required on COI for main deck location. Proper size and approved bracket were provided and installed in an acceptable location during inspection.
Condition: Improper/Lack of Maintenance
Due 7 August 2014
Resolved 7 August 2014
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Securing Means
Issued 4 August 2014 Resolved
Wheeled Dry Chem B-V unit secured to port bulwark on main deck using loose lightweight chain draped around the high pressure cylinder head, posing sever safety hazard, corrected immediately by removing chain and installing ratcheting strap around wheel/chassis.
Condition: Improper Installation
Due 7 August 2014
Resolved 7 August 2014
Personnel › Training › Familiarization Training
Issued 4 August 2014 Resolved
Deckhand was inadequately outfitted and poorly trained for safe recovery of a person from the water. Deckhand improperly aligned piping system for main fire pump, immediately received training from owner rep in attendance. Master and deckhand need to practice and demonstrate proficiency. Sighted minimal documenation of training. Corrected during inspection.
Condition: Invalid
Due 7 August 2014
Resolved 11 August 2014
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 August 2014 Resolved
PFD storage compartment on main deck not marked, had been painted over, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 7 August 2014
Resolved 11 August 2014
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 August 2014 Resolved
Crew acted unsafely in ineffectively during first attempt at man-ovebaord recovery, passed second drill.
Condition: Invalid
Due 7 August 2014
Resolved 11 August 2014
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 August 2014 Resolved
Only a superceded and invalid version of COI was posted, owner found and posted proper COI during inspection.
Condition: Invalid
Due 7 August 2014
Resolved 7 August 2014
Documentation › Certificates/Documents › FCC SSL
Issued 4 August 2014 Resolved
The posted FCC Ship Station LIcense was expired, owner replaced with a current and valid license during inspection.
Condition: Invalid
Due 7 August 2014
Resolved 7 August 2014
Engineering › Steering Gear System › Linkage
Issued 4 August 2014 Resolved
Emergency steering tackle ineffective, owner provided a working replacement block/tackle arrangement, crew demonstrated proper emergency steering operation during drill.
Condition: Improper Installation
Due 7 August 2014
Resolved 7 August 2014
Engineering › Lubricating Oil Service System › Tube
Issued 4 August 2014 Resolved
Pressurized tubing for reduction gear lube and main engine lube oil gages unsupported, posing risk of failure, entanglement and oil-spray fire hazards. Corrected during inspection.
Condition: Invalid
Due 7 August 2014
Resolved 7 August 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 August 2014 Resolved
First aid kit contents incomplete and expired, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 7 August 2014
Resolved 11 August 2014
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 4 August 2014 Resolved
Main deck trashcan combustible, replaced during inspection with metal trashcan.
Condition: Improper Installation
Due 7 August 2014
Resolved 11 August 2014
Engineering › Gas Turbine (propulsion/auxiliary-electric) › Seal
Issued 15 June 2012 Resolved
Prior to operating, demonstrate proper operation of generator.
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 19 June 2012
Resolution: Vsl demonstrated proper operation of the generator.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 22 May 2012 Resolved
Prior to operating vessel, demonstrate proper operation of the propulsion system.
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 27 May 2012
Resolution: Demonstrated proper operation of the propulsion system.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Service
Issued 19 January 2012 Resolved
Provide servicing report showing the dry chemical tank on semi-portable wheeled dry chemical extinguisher has been hydrostatically tested as per NFPA10, prior to carrying dangerous cargoes per 49 CFR 172 and 176.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2012
Resolved 28 March 2012
Resolution: Sighted proper servicing certificates and visually inspected unit, satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 17 January 2012 Resolved
Provide report showing CO2 system in engineroom is properly configured and the pull cable functions properly. See activity 4219577 narrative for problem description and temporary repair.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2012
Resolved 23 April 2012
Resolution: CO2 System is not required, is removed from vessel
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 17 January 2012 Resolved
Label CO2 pull station on main deck to be distinct and separate from fuel oil shut off instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2012
Resolved 23 April 2012
Resolution: CO2 System not required, is removed from vessel
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 17 January 2012 Resolved
Install flame screen in fuel oil tank vent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2012
Resolved 28 March 2012
Resolution: Sighted properly installed flame screen.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 January 2012 Resolved
Ship Service Generator instrument panel improperly maintained, frequency meter inoperable, open holes in panel cover, power indicator lamp adrift, panel cover adrift missing hold-down screws. worklist item, corrected during inspection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: Corrected during inspection
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 January 2012 Resolved
Electrical distribution wiring improperly supported with plastic ties, mostly within engineroom, worklist item, corrected during inspection
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: corrected during inspection.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 January 2012 Resolved
120VAC lighting fixture above Main Diesel Engine adrift, missing cover and screws, worklist item corrected during inspection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: corrected during inspection
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Air Cleaner
Issued 10 January 2012 Resolved
On SSG prime mover, improperly installed intake air cleaner falls off easily, corrected during inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: corrected during inspection.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Bearing
Issued 10 January 2012 Resolved
On SSG prime mover, alternator and drive belt excessively loose, prime for failure, worklist item corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: corrected during inspection
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Bearing
Issued 10 January 2012 Resolved
On SSG prime mover, coolant circulating pump ready to fail due to worn bearing, owner replaced during inspection.
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: Corrected during inspection
Engineering › Fuel Oil Service System › Filter
Issued 10 January 2012 Resolved
On main engine fuel oil filter, sediment drain cock was not fitted with a threaded plug, worklist item, corrected during inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: Corrected during inspection
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 10 January 2012 Resolved
On fixed CO2 system in engineroom, discharge nozzles and piping were excessively loose in brackets so that the discharge nozzle was out of position and ineffective, worklist item, corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: Corrected during inspection
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 10 January 2012 Resolved
Conduct emergency training for firefighting, man overboard and abandon ship and provide documentation, worklist item, corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: Corrected during inspection.
Lifesaving › Buoyant Apparatus › Painter
Issued 10 January 2012 Resolved
Sea painter deteriorated, will not last another year, worklist item, corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: Corrected during inspection
Lifesaving › Lifebuoys › Serviceable
Issued 10 January 2012 Resolved
Lanyard for float light on ring lifebuoy (by wheelhouse) deteriorated and improperl;y installed, worklist item, corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: Corrected during inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 January 2012 Resolved
First aid kit missing required items and has expired medicines, worklist item, corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: corrected during inspection.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 January 2012 Resolved
Portable railing at bow and stern loading areas inadequately fastened and ineffective, worklist item corrected during inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: corrected during inspection
Personnel › Training › Fire Fighting Basic
Issued 10 January 2012 Resolved
Master and Deckhand were inadequately trained for manoverboard, fire and abandon ship procedures and and subsequently failed basic drills. Worklist item, corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: corrected during inspection
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 10 January 2012 Resolved
On SSG, integral coolant fitting/hose not double-clamped, corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2012
Resolution: corrected during inspection.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 August 2011 Resolved
Repair holed and corroded shaft log in two aft void spaces. Temporary repairs authorized. No cargo or passengers until permanent repairs are made.
Action required: 705 - Other - as specified
Due 16 December 2011
Resolved 14 December 2011
Resolution: Corrected during Hull Exam, see inspection diary this case.
Construction/Loadline › Structures › Superstructure
Issued 30 September 2008 Resolved
Port windshield in pilot house is cracked in line of sight and my be weakened structurally. Replace with new windshield.
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 31 July 2009
Lifesaving › Lifefloat › Lifeline
Issued 30 September 2008 Resolved
Lifeline on the 22 person LF is wasted and deteriorated through in multiple places. Replace prior to carrying more than 32 persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 31 July 2009
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 30 September 2008 Resolved
Maintain lifesaving equipment inspections and crew drills in vessel log.
Due 1 September 2009
Resolved 31 July 2009
Engineering › Bilge Water Management System › Piping
Issued 30 September 2008 Resolved
Bilge lines in #3 hold are corroded through. Replace wasted piping with new back to good metal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2008
Resolution: Cropped and renewed bilge lines in hold #3 to good metal, installed unions to connect to existing piping.
Construction/Loadline › Hull › Transverse Frame
Issued 30 September 2008 Resolved
Transverse frames 3 and 4 in forepeak are wasted through on the port and stbd side of the keel. transverse frame 2 is wasted on the stbd side only. Crop and renew frames 3 and 4 to port and stbd vertical frames and frame 2 from keel to stbd vertical frame.
Due 1 April 2009
Resolved 1 May 2009
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 30 September 2008 Resolved
Provide proper navigation publications.
Due 1 April 2009
Resolved 31 July 2009
Engineering › Bilge Water Management System › Hose
Issued 7 May 2007 Resolved
Remove excess oil/water from engine room bilge.
Condition: Unknown
Due 30 June 2007
Resolved 29 June 2007
Engineering › Bilge Water Management System › Valve
Issued 7 May 2007 Resolved
Replace/renew valve in #3 void bilge piping.
Condition: Unknown
Due 30 June 2007
Resolved 29 June 2007
Construction/Loadline › Hull › Weld
Issued 7 May 2007 Resolved
Repair fractured welds in #1 and #2 voids.
Condition: Unknown
Due 30 June 2007
Resolved 29 June 2007
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 7 May 2007 Resolved
Install chaffing gear on generator fuel line.
Condition: Unknown
Due 30 June 2007
Resolved 29 June 2007
Engineering › Diesel Engine (propulsion-direct drive) › Air-flex Clutch
Issued 7 May 2007 Resolved
Replace/renew aft side MDE worn belt.
Condition: Unknown
Due 30 June 2007
Resolved 29 June 2007
Lifesaving › Lifebuoys › Serviceable
Issued 7 May 2007 Resolved
Stencil O/B ring life buoy and replace aft ring life buoy on pilot house.
Condition: Unknown
Due 30 June 2007
Resolved 29 June 2007
Lifesaving › Lifefloat › Float-free Link
Issued 7 May 2007 Resolved
Replace soon to expire hydro static release on life float.
Condition: Unknown
Due 30 June 2007
Resolved 29 June 2007
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 7 September 2006 Resolved
Cutlass bearing worn beyond limits, requires replacement.
Due 8 October 2006
Resolved 18 September 2006
Engineering › Steering Gear System › Rudder Bearing
Issued 7 September 2006 Resolved
Rudder appears to have dropped 1" and the rudder bearing needs replaced. This is causing the rudder quadrant to be uneven. Entire system needs removed and inspected and replaced as necessary.
Due 8 October 2006
Resolved 18 September 2006
Engineering › Steering Gear System › Linkage
Issued 7 September 2006 Resolved
Wire rope for steering system needs replaced at the quadrant. Almost 50% chaffed through.
Due 8 October 2006
Resolved 18 September 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 September 2006 Resolved
Possible leak in the bottom of the fuel tank bulkhead through to the # 4 void. UT shots required in the vicinity to locate leak. Resolve leak and crop out and renew if necessary.
Due 8 October 2006
Resolved 2 October 2006
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 September 2006 Resolved
Several small cracked welds approximately 1" in length in the #1 and #2 voids. Repair and replace welds.
Due 8 October 2006
Resolved 18 September 2006
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2006 Resolved
Test suspected area of hull for excessive wastage in #2 void.
Condition: Unknown
Due 8 October 2006
Resolved 18 September 2006
Construction/Loadline › Structures › Ventilators
Issued 3 August 2006 Resolved
Repair to original wasted section of plating at base of ventilation shaft for #2 void, port side I.A.W. 46 CFR 177.300.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2006
Resolution: Cover plate welded over wasted section.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 3 August 2006 Resolved
Provide external access control for operation of vessel's fixed CO2 system I.A.W. 46 CFR 181.410(b).
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 9 August 2006
Resolution: External access control added.
Lifesaving › Lifebuoys › Serviceable
Issued 22 September 2005 Resolved
REPLACE TWO RING BUOYS PORTSIDE PILOT HOUSE.
Due 22 October 2005
Resolved 17 October 2005
Stability › Watertight Integrity › General
Issued 22 September 2005 Resolved
REPAIR WELD FRACTURES #2 COMPARTMENT PORTSIDE.
Due 22 October 2005
Resolved 17 October 2005
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 22 September 2005 Resolved
REPLACE COOLANT HOSE ON FWD SIDE, UPPER OFF OF COOLAND TANK.
Due 22 October 2005
Resolved 17 October 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 22 September 2005 Resolved
REPAIR EMERGENCY ENGINE STOP CABLE TO GOVERNOR HOUSING.
Due 22 October 2005
Resolved 17 October 2005
Engineering › Freshwater System (intermediary cooling) › Fitting
Issued 22 September 2005 Resolved
REPLACE GENERATOR THERMOSTAT HOUSING GASKET.
Due 22 October 2005
Resolved 17 October 2005
Fire Fighting › Fire Pumps › Pressure
Issued 22 September 2005 Resolved
REPAIR MAIN DIESEL ENGINE DRIVEN FIRE PUMP.
Due 22 October 2005
Resolved 17 October 2005
Stability › Watertight Integrity › General
Issued 22 September 2005 Resolved
RPAIR WELD FRACTURES #3 COMPARTMENT ON STBD SIDE LOWER UNDER RUB RAIL.
Due 22 October 2005
Resolved 17 October 2005
Engineering › Steering Gear System › Rudder
Issued 22 September 2005 Resolved
REPAIR/ INSTALL WELD ON RUDDER POST PORT SIDE OF AFTER STEERING.
Due 22 October 2005
Resolved 17 October 2005
Construction/Loadline › Hull › Weld
Issued 23 September 2004 Resolved
Repair weld fractures FWD void 7 total.
Condition: Unknown
Due 20 May 2005
Resolved 20 May 2005
Construction/Loadline › Penetrations › Weld
Issued 23 September 2004 Resolved
Repair plug welds main deck.
Condition: Unknown
Due 20 May 2005
Resolved 20 May 2005
Engineering › Bilge Water Management System › Not Operational
Issued 23 September 2004 Resolved
Remove oil and rags from engine room bilges.
Condition: Unknown
Due 20 May 2005
Resolved 20 May 2005
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 23 September 2004 Resolved
Re-route steering cable after steering compartment.
Condition: Unknown
Due 20 May 2005
Resolved 20 May 2005
Lifesaving › Launching Appliances › Release Mechanism
Issued 23 September 2004 Resolved
Replace retaining strap on lifefloat pilothouse.
Condition: Unknown
Due 20 May 2005
Resolved 20 May 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 23 September 2004 Resolved
At servicing time re-engineer fixed fire fighting system, cable and controls. per 46CFR181.410.
Condition: Design Flaw
Due 20 May 2005
Resolved 20 May 2005
Electrical › Electrical Distribution System (service)
Issued 26 September 2003 Resolved
Remount electrical light, wires aft engine room.
Due 28 October 2003
Resolved 14 October 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 September 2003 Resolved
Repair CO2 release engine room.
Due 28 October 2003
Resolved 14 October 2003
Fire Fighting › Fire Pumps
Issued 26 September 2003 Resolved
Repair engine driven fire pump.
Due 28 October 2003
Resolved 14 October 2003
Construction/Loadline › Structures › Rake
Issued 26 September 2003 Resolved
Repair weld fractures fwd void port & stbd sides.
Due 28 November 2003
Resolved 23 September 2004
Lifesaving › Buoyant Apparatus
Issued 7 May 2002 Resolved
Replace 16 person buoyant apparatus with life float of equal capacity prior to the compliance date. Vessel is limited to carrying not more than 44 total persons unitl the life float is installed.
Condition: Unknown
Due 14 June 2002
Resolved 12 June 2002
Construction/Loadline › Hull
Issued 7 May 2002 Resolved
Repair fractures in main deck in way of the rub rail, starboard side forward, prior to the compliance date.
Condition: Unknown
Due 15 May 2002
Resolved 8 May 2002
Engineering › Bilge Water Management System
Issued 7 May 2002 Resolved
Replace rusted u-joint connection for the forepeak remote reach rod prior to the compliance date.
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 8 May 2002
Lifesaving › Lifebuoys
Issued 7 May 2002 Resolved
Provide a clip for the bridge waterlight ring buoy prior to the compliance date.
Condition: Placed in Improper Service
Due 8 May 2002
Resolved 8 May 2002
Engineering
Issued 12 June 2001 Resolved
REPAIR AND DEMONSTRATE OPERATION OF MAIN ENGINE TACHOMETER, OIL PRESSURE AND TEMPERATURE GAUGES IN THE PILOTHOUSE BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 19 June 2001
Resolved 25 July 2001
Fire Fighting
Issued 12 June 2001 Resolved
PROVIDE SERVICING REPORT FOR FIXED FIRE EXTINGUISHING EQUIPMENT, PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 19 June 2001
Resolved 25 July 2001
Engineering
Issued 12 June 2001 Resolved
MAIN ENGINE FOUNDATION BOLTS EXCESSIVELY LOOSE, CORRECTED DURING INSPECTION_x001C_
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Fire Fighting
Issued 12 June 2001 Resolved
CO2 CYLINDER EXCESSIVELTY LOOSE, CAN ROTATE AS TO SAUSE ACCIDENTAL RELEASE,CORRECTED DURING INSPECTION.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Fire Fighting
Issued 12 June 2001 Resolved
ONE BII PORT CO2 FIRE EXTINGUISHER IS PAST DUE FOR HYDROSTATIC TESTING, REPLACED DURING INSPECTION.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Lifesaving
Issued 12 June 2001 Resolved
FLOAT LIGHT FOR RING BUOY INOPERABLE, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Navigation
Issued 12 June 2001 Resolved
RUDDER STOCK EXCESSIVELY LOOSE AND WORN IN STEERING QUADRANT, WELDMENT IS ALSO CRACKED, CORRECTED DURING INSPECTION.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Construction/Loadline
Issued 12 June 2001 Resolved
REPAIR AND DEMONSTRATE OPERATION OF BILGE ALARM IN RUDDER COMARTMENT BEFORETHE COMPLIANCE DATE.
Condition: Unknown
Due 19 June 2001
Resolved 25 July 2001
Navigation
Issued 27 September 2000 Resolved
4 OF 6 COUPLING BOLTS MISSING, CORRECTED DURING INSPECTION
Condition: Unknown
Due 28 September 2000
Resolved 28 September 2000
Construction/Loadline
Issued 27 September 2000 Resolved
SEA VALVE FOR ELECTRIC FIRE PUMP HAD A DAMAGED GATE DISK, ENTIRE VALVE RENEWED IN KIND.
Condition: Unknown
Due 28 September 2000
Resolved 28 September 2000
Deck/Cargo
Issued 27 September 2000 Resolved
ANCHOR CHAIN FOULED ABOUT THE INTERNAL STRUCTURES IN FOREPEAK, CORRECTED DURING INSPECITON.
Condition: Unknown
Due 28 September 2000
Resolved 28 September 2000
Fire Fighting
Issued 17 May 2000 Resolved
CONDUCT CREW TRAINING AND PROVE THEIR PROFICIENCY IN MAN-OVERBOARD AND_x001C_ FIRE DRILLS IN THE PRESENCE OF A MARINE INSPECTOR BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 29 May 2000
Resolved 27 June 2000
Electrical
Issued 17 May 1999 Resolved
CLEAN BATTERY BOXES AND REPAIR LEAD LINING, PROVIDE SPACE BETWEEN BATTERY TERMINALS AND BULKHEAD PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Construction/Loadline
Issued 17 May 1999 Resolved
REPAIR HATCH COVER LEADING INTO THE # 5 COMPARTMENT PRIOR TO THE COMPLIANCEDATE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Fire Fighting
Issued 17 May 1999 Resolved
REPAIR FIREPUMP GAUGE PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Electrical
Issued 17 May 1999 Resolved
WIRE MDE ALTERNATOR AS REQUIRED BY 46 CFR 183.340 PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Navigation
Issued 17 May 1999 Resolved
REPAIR STEERING CABLE LOCATED AT ENGINE ROOM TRUCK PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Construction/Loadline
Issued 17 May 1999 Resolved
CLEAN ALL COMPARTMENTS OF DEBRIS AND ROCKS, MAKE READY FOR INSPECTION PRIORTO THE COMPLIANCE DATE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Construction/Loadline
Issued 17 May 1999 Resolved
PROVE OPERATION OF BILGE PUMP SUCTION IN # 4 COMPARTMENT PRIOR TO CARRYING PASSENGERS AND PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 17 May 1999
Resolved 8 June 1999
Lifesaving
Issued 17 May 1999 Resolved
INSTALL PROPER WEAKLINK FOR BUOYANT APPARATUS PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Navigation
Issued 17 May 1999 Resolved
PROVE PROPER OPERATION OF STARBOARD NAVIGATION RUNNING LIGHT PRIOR TO CARRYING PASSENGERS AND PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 17 May 1999
Resolved 8 June 1999
Construction/Loadline
Issued 17 May 1999 Resolved
REPLACE BILGE SUCTION STRAINER IN # 1 COMPARTMENT PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Fire Fighting
Issued 17 May 1999 Resolved
MARK FIRE AX WITH VESSEL NAME PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Navigation
Issued 17 May 1999 Resolved
PROVIDE COPY OF INLAND NAVIGATION RULES PRIOR TO CARRYING PASSENGERS AND PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 17 May 1999
Resolved 8 June 1999
Fire Fighting
Issued 14 May 1998 Resolved
Provide copy of Northern Fire Safety service report to Marine Inspector. Two portable fire extinguisher cylinders will require hydrostatic testing by 30MAY98.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Navigation
Issued 14 May 1998 Resolved
Lubricate cables and sheves on steering system.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Lifesaving
Issued 14 May 1998 Resolved
Renew vessel name on Ring Lifebuoy.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Engineering
Issued 16 July 1997 Resolved
Modify emergency fuel shut-off valve so that valve remains shut after closing from remote station.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Lifesaving
Issued 16 July 1997 Resolved
Attach Coast Guard approved weak link between buoyant apparatus painter andship's structure.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Lifesaving
Issued 18 May 1995 Resolved
Re-stencil PFD storage locker outside bridge, and capacity on buoyant apparatus.
Condition: Unknown
Due 18 May 1995
Resolved 18 May 1995
Construction/Loadline
Issued 18 May 1995 Resolved
Crop and renew upset bottom shell plate in forepeak, in way of 1st frame space, no later than next scheduled drydock exam. Submit repair proposal to attending marine inspector prior to starting work.
Condition: Unknown
Due 18 May 1995
Resolved 18 May 1995
Lifesaving
Issued 18 May 1995 Resolved
Replace lifelines on buoyant apparatus and bridge ring buoys.
Condition: Unknown
Due 18 May 1995
Resolved 18 May 1995
Fire Fighting
Issued 18 May 1995 Resolved
Re-charge engine room fixed CO2 system. Carry 2 extra portable B-II fire extinguishers and no passengers until corrected.
Condition: Unknown
Due 18 May 1995
Resolved 18 May 1995
Construction/Loadline
Issued 18 May 1995 Resolved
Repair hull internals as indicated on worklist numbers 1a through 1c.
Condition: Unknown
Due 18 May 1995
Resolved 18 May 1995
Deck/Cargo
Issued 24 April 1991 Resolved
Adequately secure end of anchor chain to vessel structure._x001C_ (Chain is presently secured to stanchion with an overhand knot.)
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Fire Fighting
Issued 24 April 1991 Resolved
Replace temporary fire pump with a pump capable of supplying the required_x001C_ 1 1/2 inch fire lines. (Present temporary pump has a 1 inch non-UL hose_x001C_ and no nozzle.)
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Electrical
Issued 24 April 1991 Resolved
Provide battery cover for battery: aft engineroom bulkhead.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Fire Fighting
Issued 24 April 1991 Resolved
Provide suitable hand fire and bilge pump.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Engineering
Issued 24 April 1991 Resolved
Replace deteriorated rubber connection hoses on main engine.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Navigation
Issued 24 April 1991 Resolved
Provide adequate search light.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Fire Fighting
Issued 24 April 1991 Resolved
Install new drive motor and demonstrate operation of fire pump.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Fire Fighting
Issued 24 April 1991 Resolved
Provide approved 1 1/2 inch all purpose combination fire nozzle for_x001C_ compliance with dangerous cargo regulations.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Fire Fighting
Issued 24 April 1991 Resolved
Provide evidence or annual servicing of fixed C0-2 extinguishing system_x001C_ and BV fire extinguisher.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Lifesaving
Issued 24 April 1991 Resolved
Provide and install float light for life ring.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Lifesaving
Issued 24 April 1991 Resolved
Stencil PFD stowage box on port bridge wing with number and size of_x001C_ PFD's inside.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Construction/Loadline
Issued 24 April 1991 Resolved
Weld fractures in hatch coamings, number 2 and number 3 compartments.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Construction/Loadline
Issued 24 April 1991 Resolved
Repair fractures in connection of transverse deck beams and deck in_x001C_ number 2 compartment.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Electrical
Issued 24 April 1991 Resolved
Repair or remove broken deck light, in overhead under bridge wing._x001C_ (Globe and bulb broken off, exposed remnants of bulb filament protruding.)
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991

Casualty record · 7

22 July 2011Routine · role: Involved in a Marine Casualty · activity 4094077
12 August 2011Routine · role: Involved in a Marine Casualty · activity 4118519
16 May 2012Routine · role: Involved in a Marine Casualty · activity 4315058
15 June 2012Routine · role: Involved in a Marine Casualty · activity 4348179
15 August 2012Routine · role: Involved in a Marine Casualty · activity 4416626
27 May 2014Routine · role: Involved in a Marine Casualty · activity 4871889
6 October 2015Routine · role: Involved in a Marine Casualty · activity 5742513
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CORSAIR (2011–2015). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.