Professional
The full record for this vessel
Behind this panel: 15 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 15
15 May 2026
Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8371177
19 February 2026
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8312373
18 November 2024
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8036511
6 November 2023
Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7837647
31 October 2023
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7818172
24 March 2023
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7656495
2 February 2023
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7631159
7 March 2022
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7407345
24 February 2022
Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7403653
21 October 2021
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7337263
14 October 2020
Internal Structural Exam · Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7076256
11 August 2019
COI Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6819629
13 August 2018
Examination of Repairs · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6510809
27 January 2017
Drydock Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6078514
12 January 2016
Annual Inspection · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5803727
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 May 2026
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit missing. 46 CFR 184.710.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 5 June 2026
Resolution: MI verified new First Aid kit was on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2026
Resolved
Child size life jackets equal to 10% of the number of persons permitted on board must be provided. Vessel needs provide required number of child size life jackets. 03 child lifejackets deteriorated; replace. 46 CFR 180.71.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 5 June 2026
Resolution: MI verified 03 new child size lifejackets with appropriate markings were in service on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2026
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. 02 extinguishers were corroded, replace or conduct hydrostatic testing. 46CFR181.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 5 June 2026
Resolution: MI verified new/serviced fire extinguishers on board that are appropriate size as required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy line is worn. Replace life ring buoy line. 46 CFR 176.808(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 5 June 2026
Resolution: MI verified new line was placed, and attached to Life ring bouy.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 February 2026
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel's Anniversary Date is November 25, with maximum Inspection date of February 25. Vessel scheduled for inspection on February 19, and had to cancel due to family emergency. Vessel is restricted from carrying passengers for hire until the vessel completes a satisfactory Annual Inspection. Contact our office at the number and email below to schedule inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2026
Resolution: Completed COI renewal Inspection.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 November 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted. Annual servicing is overdue on one of the portable fire extinguishers and must be conducted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 25 November 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 November 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Aft 360 degree white light is extinguished. Vessel is restricted to daytime operations until light is replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 25 November 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 November 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Aft chain, in front of outboards, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 25 November 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel cannot operate until a DD/ISE inspection is completed.
46CFR176.600 (c)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2024
Resolution: Dry dock completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 February 2023
Resolved
Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Fuel filter is constructed of materials other than steel and does not have heat deflector installed.
46CFR182.455(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2023
Resolved 24 March 2023
Resolution: New filters were installed with metal bottom. Photos attached in documents.