Records from 1995 to 2026. Most recent: inspection, 15 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 50
15 May 2026
Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8371177
19 February 2026
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8312373
18 November 2024
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8036511
6 November 2023
Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7837647
31 October 2023
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7818172
24 March 2023
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7656495
2 February 2023
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7631159
7 March 2022
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7407345
24 February 2022
Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7403653
21 October 2021
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7337263
14 October 2020
Internal Structural Exam · Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7076256
11 August 2019
COI Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6819629
13 August 2018
Examination of Repairs · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6510809
27 January 2017
Drydock Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6078514
12 January 2016
Annual Inspection · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5803727
1 December 2010
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3894092
17 November 2010
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3894071
20 October 2010
Hull Examination · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3873458
17 December 2008
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3381140
22 October 2008
Examination of Repairs · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3348927
18 December 2007
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3117430
23 October 2007
Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3085938
10 October 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3084412
15 February 2007
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2872974
11 October 2006
COI Inspection · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2802140
27 October 2005
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2526754
19 October 2005
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2567769
16 November 2004
Annual Inspection · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2254281
20 November 2003
Hull Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1953264
27 November 2002
Re-Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1717412
20 November 2002
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1709270
15 November 2001
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1417416
15 November 2001
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1457983
14 June 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1408785
8 February 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1046328
5 January 2000
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1399689
5 January 2000
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1432235
21 December 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 714465
21 December 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 811699
17 September 1999
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1404831
24 May 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 800764
19 February 1999
Damage Survey · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1404749
1 February 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1381473
5 January 1999
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368950
14 September 1998
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1402708
4 January 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1118910
6 October 1997
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1411550
11 February 1997
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1105187
1 October 1996
Re-Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363797
19 September 1995
Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1459195
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 May 2026
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit missing. 46 CFR 184.710.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 5 June 2026
Resolution: MI verified new First Aid kit was on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2026
Resolved
Child size life jackets equal to 10% of the number of persons permitted on board must be provided. Vessel needs provide required number of child size life jackets. 03 child lifejackets deteriorated; replace. 46 CFR 180.71.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 5 June 2026
Resolution: MI verified 03 new child size lifejackets with appropriate markings were in service on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2026
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. 02 extinguishers were corroded, replace or conduct hydrostatic testing. 46CFR181.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 5 June 2026
Resolution: MI verified new/serviced fire extinguishers on board that are appropriate size as required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy line is worn. Replace life ring buoy line. 46 CFR 176.808(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 5 June 2026
Resolution: MI verified new line was placed, and attached to Life ring bouy.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 February 2026
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel's Anniversary Date is November 25, with maximum Inspection date of February 25. Vessel scheduled for inspection on February 19, and had to cancel due to family emergency. Vessel is restricted from carrying passengers for hire until the vessel completes a satisfactory Annual Inspection. Contact our office at the number and email below to schedule inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2026
Resolution: Completed COI renewal Inspection.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 November 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted. Annual servicing is overdue on one of the portable fire extinguishers and must be conducted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 25 November 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 November 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Aft 360 degree white light is extinguished. Vessel is restricted to daytime operations until light is replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 25 November 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 November 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Aft chain, in front of outboards, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 25 November 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel cannot operate until a DD/ISE inspection is completed.
46CFR176.600 (c)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2024
Resolution: Dry dock completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 February 2023
Resolved
Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Fuel filter is constructed of materials other than steel and does not have heat deflector installed.
46CFR182.455(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2023
Resolved 24 March 2023
Resolution: New filters were installed with metal bottom. Photos attached in documents.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 November 2010
Resolved
Vessel shall provide arrangement for logging training and drills IAW 46CFR185.520(f) and 185.524 (d), to include date of drill/training and a general description.
Action required: 705 - Other - as specified
Due 1 December 2010
Resolved 1 December 2010
Resolution: Arrangements for logging training/drills established and verified by attending CG marine inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 22 October 2008
Resolved
Grind and repair delamination noted at the bottom hull starboard side amidships.
Condition: Design Flaw
Due 22 October 2008
Resolved 25 November 2008
Resolution: Area repaired SAT.// JAR
Construction/Loadline › Hull › Bottom Plating
Issued 22 October 2008
Resolved
Grind and repair delamination noted at the port side bottom hull from forward port to stern.
Condition: Design Flaw
Due 22 October 2008
Resolved 25 November 2008
Resolution: Area repaired SAT.//JAR
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 22 October 2008
Resolved
Replace center longitudinal member (apron) that is rotten at the 2nd compartment forward. Owner advised to provide a repair plan prior to initiate the repairs and plan approved by Coast Guard Marine Inspector.
Condition: Design Flaw
Due 22 October 2008
Resolved 25 November 2008
Resolution: Member replaced.//JAR
Construction/Loadline › Structures › Deck Plating
Issued 22 October 2008
Resolved
Replace starboard side rib that is dry rot at the forward compartment.
Condition: Design Flaw
Due 22 October 2008
Resolved 25 November 2008
Resolution: Rib replaced.//JAR
Construction/Loadline › Structures › Deck Plating
Issued 22 October 2008
Resolved
Replace support to deck center of forward compartment. Support is rotten due to moisture in compartment.
Condition: Design Flaw
Due 22 October 2008
Resolved 25 November 2008
Resolution: Deck support replaced.//JAR
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 22 October 2008
Resolved
Replace portable fire extinguishers to ensure that vessel is equipped with two B-II and one B-I as per Certificate of Inspection. At time of inspection, it was found that the vessel's all portable f/e were B-I sized.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2008
Resolved 25 November 2008
Resolution: Proper new f/e provided.// JAR
Engineering › Bilge Water Management System › Not Operational
Issued 22 October 2008
Resolved
Repair bilge pump float switch located in compartment under the pilot station.
Condition: Damaged By Earlier Event
Due 22 October 2008
Resolved 25 November 2008
Resolution: Float switch replaced and tested SAT. //JAR
Engineering › Bilge Water Management System › Not Operational
Issued 22 October 2008
Resolved
Repair the high level alarm at the pilot station to ensure it is visual and audible.
Condition: Improper Installation
Due 22 October 2008
Resolved 25 November 2008
Resolution: Alarm repaired and test SAT. //JAR
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 22 October 2008
Resolved
Make repairs to aft rails. The aft rails had excessive movement sideways.
Condition: Improper Installation
Due 22 October 2008
Resolved 25 November 2008
Resolution: Rails repaired.// JAR
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure Gauge
Issued 22 October 2008
Resolved
Service the B-I portable fire extinguisher that gauge is showing empty.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2008
Resolved 25 November 2008
Resolution: New f/e provided. //JAR
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 October 2008
Resolved
Secure electrical wires under the main deck of the pilot station.
Condition: Improper Installation
Due 22 October 2008
Resolved 25 November 2008
Resolution: Wires secured. //JAR
Lifesaving › Lifebuoys › Serviceable
Issued 23 October 2007
Resolved
Make repairs or replace ring lifebuoy. The lifebuoy has damage grablines and reflective tape. The lifeline is not of a dark color.
Condition: Improper/Lack of Maintenance
Due 23 November 2007
Resolved 18 December 2007
Resolution: As per owner, lines replaced.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 October 2007
Resolved
Provide alcohol testing kit for each crewmember as per 46 CFR Part 4.06.
Condition: Unknown
Due 18 December 2007
Resolved 11 January 2008
Resolution: Kits provided.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 23 October 2007
Resolved
Provide new certificate from the Maritime Consortium attesting crewmember is in full compliance. Owner has evidence the crewmember had the pre-employment test done back on Aug04 and Nov05, but the Maritime Consortium states that test-pending. Apparently the results has not been credited to the crewmember.
Due 29 February 2008
Resolved 11 February 2008
Resolution: The Maritime Consortium provided statement via e-mail that crewmember was in full compliance and will issued a compliance letter today.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 23 October 2007
Resolved
Adjust forward safety lines to reduce slack.
Condition: Improper Installation
Due 23 November 2007
Resolved 18 December 2007
Resolution: As per owner, lines adjusted.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 23 October 2007
Resolved
Provide safety rails aft by transom with rails courses of not more than 12" high. As per 46CFR 178.900 (d) & (g), vessel required t have safety rails at least 39.5" high, but design of vessel aft will accommodate only 36" high without major modifications.
Due 23 November 2007
Resolved 18 December 2007
Resolution: As per owner, rails provided.
Engineering › Bilge Water Management System › Interface Detector
Issued 23 October 2007
Resolved
Repair high level alarm indicator at the pilot station. Indicator visual side not working. Audible OK.
Condition: Design Flaw
Due 23 November 2007
Resolved 11 January 2008
Resolution: Indicator repaired.
Construction/Loadline › Hull › Keel
Issued 10 October 2007
Resolved
Make repairs to starboard side of keel aft where delaminated.
Condition: Damaged By Earlier Event
Due 23 October 2007
Resolved 23 November 2007
Resolution: Provide evidence of proper repairs.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 October 2006
Resolved
Provide equivalent first aid kit. Present kit had expired medication or missing medication.
Condition: Improper/Lack of Maintenance
Due 24 November 2006
Resolved 16 February 2007
Resolution: Exam kit and found sat.
Engineering › Bilge Water Management System › Not Operational
Issued 11 October 2006
Resolved
Provide an audible and visual alarm at the pilot station for the bilge high level alarm. Alarm visual indicator working, but not the audible indicator.
Condition: Design Flaw
Due 24 November 2006
Resolved 16 February 2007
Resolution: Owner replace float switch and tested sat.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 11 October 2006
Resolved
Return master mariner license to the Regional Examination Center to have license be resigned or have a new license issued. Close inspection of license showed that it was signed, but signature signature had faded.
Due 24 November 2006
Resolved 30 October 2006
Resolution: As per OCMI, mariner will be allowed to keep his current license until a replacement is provide to him. He is OK.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 27 October 2005
Resolved
Provide a valid Merchant Mariner Officer document (master license) as per 46CFR15.401 and 15.805(a)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2006
Resolution: New license provided.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 27 October 2005
Resolved
Provide evidence of crewmember enrollment in a drug testing consortium as per 46CFR 16.113 with pre-employment testing as per 46CFR 16.210(a).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2006
Resolution: Evidence provided with crewmember included.
Engineering › Bilge Water Management System › Interface Detector
Issued 27 October 2005
Resolved
Provide a visual and audible alarm at the operating station for the bilge high level alarm as per 46CFR 185.530(a).
Condition: Damaged By Earlier Event
Due 27 November 2005
Resolved 13 January 2006
Resolution: System repaired and tested sat. Problem was a loose wire behind buzzer.
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 October 2005
Resolved
Make available required crewmember as per COI to conduct underway drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2006
Resolution: Done.
Construction/Loadline › Hull › Bottom Plating
Issued 16 November 2004
Resolved
Grind and repair portside keel aft.
Condition: Design Flaw
Due 23 November 2004
Resolved 23 November 2004
Resolution: Properly repaired.
Construction/Loadline › Hull › Bottom Plating
Issued 16 November 2004
Resolved
Grind and repair starboard side of keel aft.
Condition: Design Flaw
Due 23 November 2004
Resolved 23 November 2004
Resolution: Properly repaired.
Construction/Loadline › Hull
Issued 20 November 2003
Resolved
Make repairs to top side of bow where marked.
Action required: 705 - Other - as specified
Resolved 11 December 2003
Construction/Loadline › Hull
Issued 20 November 2003
Resolved
Make proper repairs to port side amidship rail support brackets. LEGACY COMPONENT DESC: Rail Support Bracket
Action required: 705 - Other - as specified
Resolved 11 December 2003
Construction/Loadline › Hull
Issued 20 November 2003
Resolved
Make proper repairs to the stbd amidship rail support bracket. LEGACY COMPONENT DESC: Rail Support Bracket
Action required: 705 - Other - as specified
Resolved 11 December 2003
Documentation › Logs/Records
Issued 27 November 2002
Resolved
Provide log to document crew training (fire, man overboard) and periodic checks of the lifesaving equipment. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Due 11 December 2002
Resolved 12 December 2002
Resolution: Log provided.
Lifesaving › Visual Distress Signals (General)
Issued 27 November 2002
Resolved
Provide 3 orange day smokes. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 11 December 2002
Resolved 12 December 2002
Resolution: New smokes provided.
Engineering › Gasoline Engine (propulsion)
Issued 27 November 2002
Resolved
Repair fuel hose to starboard portable fuel tank where cracked.
Condition: Improper Installation
Due 11 December 2002
Resolved 12 December 2002
Resolution: Hose repaired.
Engineering
Issued 27 November 2002
Resolved
Provide vilge high lever alarm to be visible and audible. Alarm to be located at the operating station as required by 46CFR182.530(a)(3), (b) & (c)
Condition: Improper Installation
Due 11 December 2002
Resolved 12 December 2002
Resolution: New alarm provided and tested.
Engineering
Issued 27 November 2002
Resolved
Make bilge pumps to operate automatic with float (sapito).
Condition: Improper Installation
Due 13 January 2003
Resolved 12 December 2002
Resolution: Float switch installed.
Lifesaving
Issued 27 November 2002
Resolved
Replace expired medication from first aid kit.
Condition: Improper/Lack of Maintenance
Due 11 December 2002
Resolved 12 December 2002
Resolution: New medication provided.
Lifesaving › Lifebuoys
Issued 27 November 2002
Resolved
Provide a 3-foot lanyard with a corrosion resistant clip to lifebuoy to be able to separate light from bouy. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper Installation
Due 11 December 2002
Resolved 12 December 2002
Resolution: Provided.
Personnel › Training
Issued 27 November 2002
Resolved
Conduct fire and man overboard drill while underway. LEGACY COMPONENT DESC: Passenger Safety
Condition: Unknown
Due 11 December 2002
Resolved 12 December 2002
Resolution: Drills conducted with sat results.
Documentation
Issued 15 November 2001
Resolved
Vessel to provide drills and training book.
Condition: Unknown
Due 1 December 2001
Resolved 27 November 2001
Fire Fighting
Issued 15 November 2001
Resolved
Vessel to Provide two(2) fire extinguishers, size B:II
Condition: Unknown
Due 1 December 2001
Resolved 27 November 2001
Lifesaving
Issued 15 November 2001
Resolved
Vessel to provide three(3) day smoke flares.
Condition: Unknown
Due 1 December 2001
Resolved 27 November 2001
Lifesaving
Issued 17 September 1999
Resolved
DEMONSTRATE FIRE/MANOVERBOARD DRILL IN PRESENCE OF CG INSPECTOR.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Documentation
Issued 17 September 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Accommodation/Occupational Safety
Issued 5 January 1999
Resolved
RAISE THE VENTS FOR THE FORWARD COMPARTMENT TO JUST BELOW THE SEATS AND PROVIDE AN ELBOW ON THE TOP.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Construction/Loadline
Issued 5 January 1999
Resolved
CONDUCT PERMANENT REPAIRS TO STBD SIDE OF TRANSOM.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Fire Fighting
Issued 5 January 1999
Resolved
PROVIDE PROPER BRACKETS FOR THE B-I FIRE EXTINGUISHER ADJACENT TO HELM.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Construction/Loadline
Issued 5 January 1999
Resolved
CHANGE THE TWO CORRODED BOLTS IN THE TRANSVERSE FRAME IN THE AFT COMPARTMENT.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Documentation
Issued 5 January 1999
Resolved
PROVIDE PROPER DOCUMENTATION OF FULLY COMPLIANT CHEMICAL TESTING PROGRAM INACCORDANCE WITH 46CFR PART 16 IN ENGLISH. RECEIVED PROPER DOCUMENTATION INSPANISH.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Fire Fighting
Issued 5 January 1999
Resolved
PROVIDE PROPER BRACKETS FOR THE B-II FIRE EXTINGUISHER ADJACENT TO THE ENGINES.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Fire Fighting
Issued 14 September 1998
Resolved
Provide proper securing devices for fire extinguishers. 46 CFR 181.520_x001C_
Condition: Unknown
Due 1 October 1998
Resolved 12 January 1999
Documentation
Issued 6 October 1997
Resolved
PROVIDE EVIDENCE OF ENROLLMENT IN RANDOM AND PRE-EMPLOYMENT DRUG TESTING PROGRAM
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Lifesaving
Issued 6 October 1997
Resolved
PROVIDE COAST GUARD APPROVED FIRST AID KIT
Condition: Unknown
Due 6 November 1997
Resolved 9 October 1997
Lifesaving
Issued 6 October 1997
Resolved
PROVIDE OPERABLE WATERLIGHT FOR LIFE RING
Condition: Unknown
Due 6 November 1997
Resolved 9 October 1997
Lifesaving
Issued 6 October 1997
Resolved
PROVIDE LIFE JACLET DONNING PROCEDUERS PLACARD
Condition: Unknown
Due 6 November 1997
Resolved 9 October 1997
Lifesaving
Issued 6 October 1997
Resolved
PROVIDE 60 FT OF BOUYANT LINE, DARK IN COLOR FOR LIFE RING
Condition: Unknown
Due 6 November 1997
Resolved 9 October 1997
Fire Fighting
Issued 6 October 1997
Resolved
PROVIDE 3 FIRE BUCKETS
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Lifesaving
Issued 6 October 1997
Resolved
RENEW RETRO-REFLECTIVE ON LIFE RING
Condition: Unknown
Due 6 November 1997
Resolved 9 October 1997
Accommodation/Occupational Safety
Issued 1 October 1996
Resolved
PRIOR TO BOARDING PASSENGERS, REPAIR BROKEN TOP METAL HANDRAIL AT PORT SIDEEMBARKATION AREA.
Condition: Unknown
Due 1 October 1996
Resolved 2 October 1996
Accommodation/Occupational Safety
Issued 1 October 1996
Resolved
REPAIR CRACKED FIBERGLASS GUNNEL IWO BASE SUPPORT FOR PORTSIDE HAND RAIL STANCHION FORWARD OF EMBARKATION AREA.
Condition: Unknown
Due 1 October 1996
Resolved 2 October 1996
Documentation
Issued 1 October 1996
Resolved
POST CERTIFICATE OF INSPECTION UPON RECEIPT.
Condition: Unknown
Due 11 February 1997
Resolved 11 February 1997
Accommodation/Occupational Safety
Issued 1 October 1996
Resolved
PRIOR TO BOARDING PASSENGERS, RENEW REMOVABLE HAND RAILS (SMALL DIAMETER COTTON LINE) WITH SUITABLE INSTALLED RAILS.
Condition: Unknown
Due 1 October 1996
Resolved 2 October 1996
Navigation
Issued 1 October 1996
Resolved
PRIOR TO BOARDING PASSENGERS, REPAIR INOPERABLE HORN.
Condition: Unknown
Due 1 October 1996
Resolved 2 October 1996
Navigation
Issued 1 October 1996
Resolved
PRIOR TO BOARDING PASSENGERS, REPAIR INOPERABLE PORT SIDE NAVIGATIONAL RUNNING LIGHT.
Condition: Unknown
Due 1 October 1996
Resolved 1 October 1996
Fire Fighting
Issued 1 October 1996
Resolved
PRIOR TO BOARDING PASSENGERS, MOUNT BRACKETS FOR BOTH B-II PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 1 October 1996
Resolved 2 October 1996